• 제목/요약/키워드: Pushover Analysis

검색결과 324건 처리시간 0.021초

비좌굴가새의 보강 전과 후의 철골 특수모멘트저항골조 건물의 R계수 평가 (Evaluation of Response Modification Factor of Steel Special Resisting Frame Building Before and After Retrofitted with Buckling Restrained Brace)

  • 신지욱;이기학;조영욱
    • 한국지진공학회논문집
    • /
    • 제17권1호
    • /
    • pp.11-19
    • /
    • 2013
  • This research presents that seismic performance of steel moment resisting frame building designed by past provision(UBC, Uniform Building Code) before and after retrofitted with BRB (Buckling-Restrained Brace) was evaluated using response modification factor (R-factor). In addition, the seismic performance of the retrofitted past building was compared with that specified in current provision. The past building considered two different connections: bilinear connection, which was used by structural engineer for building design, and brittle connection observed in past earthquakes. The nonlinear pushover analysis and time history analysis were performed for the analytical models considered in this study. The R-factor was calculated based on the analytical results. When comparing the R-factor of the current provision with the calculated R-factor, the results were different due to the hysteresis characteristics of the connection types. After retrofitted with BRBs, the past buildings with the bilinear connection were satisfied with the seismic performance of the current provision. However, the past buildings with the brittle connection was significantly different with the R-factor of the current provision.

Vulnerability and seismic improvement of architectural heritage: the case of Palazzo Murena

  • Liberotti, Riccardo;Cluni, Federico;Gusella, Vittorio
    • Earthquakes and Structures
    • /
    • 제18권3호
    • /
    • pp.321-335
    • /
    • 2020
  • The aim of the present contribution is to consider and underline the essential interactions among the historical knowledge, the seismic vulnerability assessment, the investigation experimental tools, the preservation of the architectural quality and the strengthening design in regard to architectural heritage conservation. These topics are argued in relation to Palazzo Murena in Perugia, designed in the eighteenth century by the famous Architect Luigi Vanvitelli, and currently headquarters of the city's University. Based on the surveys and the visual inspections, a preliminary a priori global analysis has been performed by means of the FME method. The obtained results permitted to plan an experimental tests campaign inclusive of structural health monitoring. The new achieved "knowledge" of the building allowed to refine the seismic safety assessment. In particular it was highlighted that the "mezzanine floor" can be a vulnerable element of the building with the collapse of its masonry walls. Preserving the architectural characteristics, a local reinforcement intervention is proposed for the above-mentioned level; this consists of the application of plaster with FRCM, assuring an adequate strength, without burden the masonry structure with additional weight, and therefore a decreasing of the seismic vulnerability. The necessity to consider, in this ongoing research, other local mechanisms is highlighted in the unfolding of the last part of work.

Performance Based Seismic Design State of Practice, 2012 Manila, Philippines

  • Sy, Jose A.;Anwar, Naveed;HtutAung, Thaung;Rayamajhi, Deepak
    • 국제초고층학회논문집
    • /
    • 제1권3호
    • /
    • pp.203-209
    • /
    • 2012
  • The purpose of this paper is to present the state of practice being used in the Philippines for the performance-based seismic design of reinforced concrete tall buildings. Initially, the overall methodology follows "An Alternative Procedure for Seismic Analysis and Design of Tall Buildings Located in the Los Angeles Region, 2008", which was developed by Los Angeles Tall Buildings Structural Design Council. After 2010, the design procedure follows "Tall Buildings Initiative, Guidelines for Performance-Based Seismic Design of Tall Buildings, 2010" developed by Pacific Earthquake Engineering Research Center (PEER). After the completion of preliminary design in accordance with code-based design procedures, the performance of the building is checked for serviceable behaviour for frequent earthquakes (50% probability of exceedance in 30 years, i.e,, with 43-year return period) and very low probability of collapse under extremely rare earthquakes (2% of probability of exceedance in 50 years, i.e., 2475-year return period). In the analysis, finite element models with various complexity and refinements are used in different types of analyses using, linear-static, multi-mode pushover, and nonlinear-dynamic analyses, as appropriate. Site-specific seismic input ground motions are used to check the level of performance under the potential hazard, which is likely to be experienced. Sample project conducted using performance-based seismic design procedures is also briefly presented.

The investigation of seismic performance of existing RC buildings with and without infill walls

  • Dilmac, Hakan;Ulutas, Hakan;Tekeli, Hamide;Demir, Fuat
    • Computers and Concrete
    • /
    • 제22권5호
    • /
    • pp.439-447
    • /
    • 2018
  • One of the important factors is the infill walls in the change of the structural rigidity, ductility, dynamic and static characteristics of the structures. The infill walls are not generally included in numerical analysis of reinforced concrete (RC) structural system due to lack of suitable theory and the difficulty of calculating the recommended models. In seismic regions worldwide, the residential structures are generally RC buildings with infill wall. Therefore, understanding the contribution of the infill walls to seismic performance of buildings may have a vital importance. This paper investigates the effects of infill walls on seismic performance of the existing RC residential buildings by considering requirements of the Turkish Earthquake Code (TEC). Seismic performance levels of residential RC buildings with and without walls in high-hazard zones were determined according to the nonlinear procedure given in the code. Pushover curves were obtained by considering the effect of masonry infill walls on seismic performance of RC buildings. The analysis results showed that the infill walls beneficially effected to the rigidity, roof displacements and seismic performance of the building.

Sustainable retrofit design of RC frames evaluated for different seismic demand

  • Zerbin, Matteo;Aprile, Alessandra
    • Earthquakes and Structures
    • /
    • 제9권6호
    • /
    • pp.1337-1353
    • /
    • 2015
  • Seismic upgrading of existing structures is a technical and social issue aimed at risk reduction. Sustainable design is one of the most important challenges in any structural project. Nowadays, many retrofit strategies are feasible and several traditional and innovative options are available to engineers. Basically, the design strategy can lead to increase structural ductility, strength, or both of them, but also stiffness regulation and supplemental damping are possible strategies to reduce seismic vulnerability. Each design solution has different technical and economical performances. In this paper, four different design solutions are presented for the retrofit of an existing RC frame with poor concrete quality and inadequate reinforcement detailing. The considered solutions are based on FRP wrapping of the existing structural elements or alternatively on new RC shear walls introduction. This paper shows the comparison among the considered design strategies in order to select the suitable solution, which reaches the compromise between the obtained safety level and costs during the life-cycle of the building. Each solution is worked out by considering three different levels of seismic demand. The structural capacity of the considered retrofit solutions is assessed with nonlinear static analysis and the seismic performance is evaluated with the capacity spectrum method.

역V형 특수가새골조의 반응수정계수 (Response Modification Factors of Inverted V-type Special Concentrically Braced Frames)

  • 김진구;남광희
    • 한국지진공학회논문집
    • /
    • 제8권1호
    • /
    • pp.29-37
    • /
    • 2004
  • 초과강도계수와 연성계수는 현행 내진기준에서 사용되는 반응수정계수를 결정하기 위한 두 가지 중요한 계수이다. 본 논문에서는 다양한 층수 및 경간을 갖는 역V형 특수 중심가새골조의 비선형 정적 해석을 수행하여 초과강도계수와 연성계수를 구하고 이를 이용하여 반응 수정계수를 산정하였다. 해석결과에 따르면 저층 구조물의 경우 IBC-2000에서 제시한 값보다 큰 반응수정계수 값을 가지며, 중층 이상의 경우 기준에서 제시한 값보다 작은 값으로 나타났다. 또한 초과강도계수와 연성계수는 구조물의 높이가 감소할수록, 스팬의 길이가 증가할수록 증가하는 것으로 나타났다.

2016년 경주지진에 의한 중층 RC 건물의 내진 성능 평가 (Seismic Performance Assessment of a Mid-Rise RC Building subjected to 2016 Gyeongju Earthquake)

  • 이도형;전종수
    • 한국지진공학회논문집
    • /
    • 제20권7_spc호
    • /
    • pp.473-483
    • /
    • 2016
  • In this paper, seismic performance assessment has been examined for a mid-rise RC building subjected to 2016 Gyeongju earthquake occurred in Korea. For the purpose of the paper, 2D external and internal frames in each direction of the building have been employed in the present comparative analyses. Nonlinear static pushover analyses have been conducted to estimate frame capacities. Nonlinear dynamic time-history analyses have also been carried out to examine demands for the frames subjected to ground motions recorded at stations in near of Gyeongju and a previous earthquake ground motion. Analytical predictions demonstrate that maximum demands are significantly affected by characteristics of both spectral acceleration response and spectrum intensity over a wide range of periods. Further damage potential of the frames has been evaluated in terms of fragility analyses using the same ground motions. Fragility results reveal that the ground motion characteristics of the Gyeongju earthquake have little influence on the seismic demand and fragility of frames.

역V형 보통가새골조의 반응수정계수 (Response Modification Factors of Inverted V-type Ordinary Concentrically Braced Frames)

  • 김진구;남광희
    • 한국지진공학회논문집
    • /
    • 제8권3호
    • /
    • pp.53-62
    • /
    • 2004
  • 본 논문에서는 현행 내진설계방법에 따라 설계된 역V형 보통 가새골조 (OCBF)의 비선형 정적 해석을 수행하고, 그 결과를 바탕으로 초과강도계수, 연성계수, 반응수정계수 및 변위 증폭계수 등을 산정하였다. 해석결과에 따르면 대부분의 해석모델에서 현행 내진설계 기준에서 제시한 값보다 작은 초과강도계수 및 반응수정계수 값을 가지는 것으로 나타났다. 그러나 수직 보강 기둥 (zipper column)으로 가새를 보강한 경우 초과강도계수 및 반등수정계수는 보통 가새 구조물에 비하여 상당히 증가하는 것으로 나타났다.

Static analysis of functionally graded non-prismatic sandwich beams

  • Rezaiee-Pajand, M.;Masoodi, Amir R.;Mokhtari, M.
    • Advances in Computational Design
    • /
    • 제3권2호
    • /
    • pp.165-190
    • /
    • 2018
  • In this article, the static behavior of non-prismatic sandwich beams composed of functionally graded (FG) materials is investigated for the first time. Two types of beams in which the variation of elastic modulus follows a power-law form are studied. The principle of minimum total potential energy is applied along with the Ritz method to derive and solve the governing equations. Considering conventional boundary conditions, Chebyshev polynomials of the first kind are used as auxiliary shape functions. The formulation is developed within the framework of well-known Timoshenko and Reddy beam theories (TBT, RBT). Since the beams are simultaneously tapered and functionally graded, bending and shear stress pushover curves are presented to get a profound insight into the variation of stresses along the beam. The proposed formulations and solution scheme are verified through benchmark problems. In this context, excellent agreement is observed. Numerical results are included considering beams with various cross sectional types to inspect the effects of taper ratio and gradient index on deflections and stresses. It is observed that the boundary conditions, taper ratio, gradient index value and core to the thickness ratio significantly influence the stress and deflection responses.

Performance-based seismic design of eccentrically braced steel frames using target drift and failure mode

  • Li, Shen;Tian, Jian-bo;Liu, Yun-he
    • Earthquakes and Structures
    • /
    • 제13권5호
    • /
    • pp.443-454
    • /
    • 2017
  • When eccentrically braced steel frames (EBFs) are in the desired failure mode, links yield at each layer and column bases appear plastically hinged. Traditional design methods cannot accurately predict the inelastic behavior of structures owing to the use of capacity-based design theory. This paper proposes the use of performance-based seismic design (PBSD) method for planning eccentrically braced frames. PBSD can predict and control inelastic deformation of structures by target drift and failure mode. In buildings designed via this process, all links dissipate energy in the rare event of an earthquake, while other members remain in elastic state, and as the story drift is uniform along the structure height, weak layers will be avoided. In this condition, eccentrically braced frames may be more easily rehabilitated after the effects of an earthquake. The effectiveness of the proposed method is illustrated through a sample case study of ten-story K-type EBFs and Y- type EBFs buildings, and is validated by pushover analysis and dynamic analysis. The ultimate state of frames designed by the proposed method will fail in the desired failure mode. That is, inelastic deformation of structure mainly occurs in links; each layer of links involved dissipates energy, and weak layers do not exist in the structure. The PBSD method can provide a reference for structural design of eccentrically braced steel frames.