• Title/Summary/Keyword: Pure Fluid

Search Result 214, Processing Time 0.025 seconds

The Correlation Analysis of Fluid Intake, Skin Hydration and Skin pH of College Students (대학생의 수분섭취, 피부 수분보유도 및 피부 pH와의 관계)

  • Kim, Nam-Jo;Hong, Hae Sook
    • Journal of Korean Biological Nursing Science
    • /
    • v.17 no.2
    • /
    • pp.132-139
    • /
    • 2015
  • Purpose: The purpose of this study was to verify the correlation analysis between fluid intake on skin hydration and pH of college students. Methods: The subjects were 129 female nursing students in D city. Data were collected by a self-administered questionnaire, using a skin moisture checker and skin pH meter on faces, hands, and feet. The collected data were analyzed by descriptive statistics, t-test, ANOVA, and Pearson correlation analysis, using SPSS WIN, 20. Results: The daily fluid intake was composed of 57% pure water, 21% caffeinated beverages, 22% non-caffeinated beverages. There were significant differences in average skin hydration on the three body parts according to pure water, caffeinated beverages, and non-caffeinated beverages; however, there was no significant difference measured by fluid intake. There was a significant positive correlation between fluid intake and skin hydration: between pure water and skin hydration. There was significant negative correlation between caffeinated beverages and skin hydration: between non-caffeinated beverages and skin hydration. Conclusion: The results suggest that fluid intake, pure water, caffeinated beverages, and non-caffeinated beverages have an effect on skin hydration and pH. Therefore, it is good to increase the amount of fluid intake but, it is recommended to increase the amount of intake of pure water rather than beverages to improve skin status.

A Study on Fluid Intake and Output Measurements (수분 섭취 및 배설량의 측정방법에 관한 연구)

  • Choi, Smi;Yang, Young-Hee;Jung, Yun
    • Journal of Korean Academy of Nursing
    • /
    • v.25 no.1
    • /
    • pp.88-98
    • /
    • 1995
  • The Fluid and electrolytes balance in the body is of critical importance in maintaining good health. When the fluid and electrolyte imbalance is present, patients are in great danger. They must be assessed immediately by a nurse so that appropriate treatment can be started as soon as possible. Patients' fluid intake and output records contain highly important information for the diagnosis and treatment of fluid imbalance, but, these records are often inaccurate and the method of recording the fluid intake is not universal for every hospital. Be-cause they are few quantitative measurements of a patient's hydration, the need to improve the accuracy of fluid intake records is very important. However, very few studies have been done to investigate the accuracy of measurements of patients' fluid intake and output. The purpose of this study was to investigate the methods used for calculation of fluid intake which is most similar to fluid output in normal adults and hospitalized patients. This study focused on three different calculation methods for fluid intake and compared these to fluid output and developed suggestions as to the ideal way to record fluid in-take. Data for 43 hospitalized patients and 37 normal adults were analyzed. The findings of this study are as follows ; 1) In normal adults, the daily intake of water which enteres by the oral route was 2415m1 (the first method of calculation). The daily intake of water in the form of pure water or some other beverage was 1365m1 (the third method of calculation) The daily intake of water including fresh fruits and vegetables, rice, porridges, and Me m which have water content more than 80% were 2186m1 (the second method of calculation). 2) The urine output of the normal adults was 1350m1. This apprroximates the amount of fluid an adult takes in the form of pure water. 3) In patient group, the total intake of water was 2550m1 (the first method of calculation). The in-take of water in the form of pure water or as some other beverage and IV fluid was 1661m1 (the third method of calculation). The daily in-take of water including foods which have high water content was 2356m1 (the second method of calculation). 4) The urine output of the patient's group was 1728m1. This approximates the amount of fluid an adult takes in the form of pure water. 5) Investigation of the method of calculation of the patient fluid intake showed that among the 31 hospitals studied, only eight use the third method of calculation which reflects the most close value to urine output. From the results obtained in this study, it was indicated that the amount of fluid taken in the form of pure water reflects the most close value to urine output. Therefore, it can be suggested that the third method of calculation which includes water in-take only in the form of pure water or beverage should be used as patients' fluid intake record.

  • PDF

RICCI ρ-SOLITON IN A PERFECT FLUID SPACETIME WITH A GRADIENT VECTOR FIELD

  • Dibakar Dey;Pradip Majhi
    • Communications of the Korean Mathematical Society
    • /
    • v.38 no.1
    • /
    • pp.235-242
    • /
    • 2023
  • In this paper, we studied several geometrical aspects of a perfect fluid spacetime admitting a Ricci ρ-soliton and an η-Ricci ρ-soliton. Beside this, we consider the velocity vector of the perfect fluid space time as a gradient vector and obtain some Poisson equations satisfied by the potential function of the gradient solitons.

Audiogram in Response to Stimulation Delivered to Fluid Applied to the External Meatus

  • Geal-Dor, Miriam;Chordekar, Shai;Adelman, Cahtia;Kaufmann-Yehezkely, Michal;Sohmer, Haim
    • Journal of Audiology & Otology
    • /
    • v.24 no.2
    • /
    • pp.79-84
    • /
    • 2020
  • Background and Objectives: Hearing can be elicited in response to vibratory stimuli delivered to fluid in the external auditory meatus. To obtain a complete audiogram in subjects with normal hearing in response to pure tone vibratory stimuli delivered to fluid applied to the external meatus. Subjects and Methods: Pure tone vibratory stimuli in the audiometric range from 0.25 to 6.0 kHz were delivered to fluid applied to the external meatus of eight participants with normal hearing (15 dB or better) using a rod attached to a standard clinical bone vibrator. The fluid thresholds obtained were compared to the air conduction (AC), bone conduction (BC; mastoid), and soft tissue conduction (STC; neck) thresholds in the same subjects. Results: Fluid stimulation thresholds were obtained at every frequency in each subject. The fluid and STC (neck) audiograms sloped down at higher frequencies, while the AC and BC audiograms were flat. It is likely that the fluid stimulation audiograms did not involve AC mechanisms or even, possibly, osseous BC mechanisms. Conclusions: The thresholds elicited in response to the fluid in the meatus likely reflect a form of STC and may result from excitation of the inner ear by the vibrations induced in the fluid. The sloping fluid audiograms may reflect transmission pathways that are less effective at higher frequencies.

Audiogram in Response to Stimulation Delivered to Fluid Applied to the External Meatus

  • Geal-Dor, Miriam;Chordekar, Shai;Adelman, Cahtia;Kaufmann-Yehezkely, Michal;Sohmer, Haim
    • Korean Journal of Audiology
    • /
    • v.24 no.2
    • /
    • pp.79-84
    • /
    • 2020
  • Background and Objectives: Hearing can be elicited in response to vibratory stimuli delivered to fluid in the external auditory meatus. To obtain a complete audiogram in subjects with normal hearing in response to pure tone vibratory stimuli delivered to fluid applied to the external meatus. Subjects and Methods: Pure tone vibratory stimuli in the audiometric range from 0.25 to 6.0 kHz were delivered to fluid applied to the external meatus of eight participants with normal hearing (15 dB or better) using a rod attached to a standard clinical bone vibrator. The fluid thresholds obtained were compared to the air conduction (AC), bone conduction (BC; mastoid), and soft tissue conduction (STC; neck) thresholds in the same subjects. Results: Fluid stimulation thresholds were obtained at every frequency in each subject. The fluid and STC (neck) audiograms sloped down at higher frequencies, while the AC and BC audiograms were flat. It is likely that the fluid stimulation audiograms did not involve AC mechanisms or even, possibly, osseous BC mechanisms. Conclusions: The thresholds elicited in response to the fluid in the meatus likely reflect a form of STC and may result from excitation of the inner ear by the vibrations induced in the fluid. The sloping fluid audiograms may reflect transmission pathways that are less effective at higher frequencies.

PSEUDO PROJECTIVE RICCI SYMMETRIC SPACETIMES

  • De, Uday Chand;Majhi, Pradip;Mallick, Sahanous
    • Communications of the Korean Mathematical Society
    • /
    • v.33 no.2
    • /
    • pp.571-580
    • /
    • 2018
  • The object of the present paper is to prove the non-existence of pseudo projective Ricci symmetric spacetimes $(PW\;RS)_4$ with different types of energy momentum tensor. We also discuss whether a fluid $(PW\;RS)_4$ spacetime with the basic vector field as the velocity vector field of the fluid can admit heat flux. Next we consider perfect fluid and dust fluid $(PW\;RS)_4$ spacetimes respectively. Finally we construct an example of a $(PW\;RS)_4$ spacetime.

Numerical Study On Combined Natural Convection-Radiation In Partially Open Square Compartments with A Heater (발열체가 있는 열린 공간내에서의 자연대류-복사열전달 현상에 관한 수치적 연구)

  • 손봉세;한규익;서석호;이재효;김태국
    • Fire Science and Engineering
    • /
    • v.9 no.1
    • /
    • pp.10-19
    • /
    • 1995
  • Study on combined natural convection-radiation In partially open square enclosures filled with absorbing-anisotropic scattering media is performed. A heater block located in the enclosure causes the natural circulation of the fluid in the enclosure which results In significant in-flow of the cold fluid through the partially open wall. Four different locations of the heater are considered to observe the effect of the heater locations on the resulting heat transfer. Results obtained from the combined convection-radiation analyses show much stronger circulation of t he fluid inside the enclosure as compared to those obtained from the pure convection analyses. As the ratio of the open area is Increased, the inflow of the cold fluid and the circulation of the fluid inside the enclosure is increased causing lower fluid temperature Inside the enclosure. It is shown that the location of the heater influences the circulation and heat transfer significantly by showing stronger circulations and more uniform temperature distributions for the cases where the heater is located on the bottom wall as compared to those for the cases where the heater is located on the upper part wall of the enclosure. For pure absorbing medium, the expected circulation in the fluid is relatively week as compared to those with absorbing-scattering medium due to the smaller wall heating as the radiant heat is used to heat the fluid instead. The forward anisotropic scattering phase function is shown to increase the fluid circulation further as compared to the isotropic scattering medium.

  • PDF

Development of a High Accuracy Pure Upwind Difference Scheme (고차 정확도의 순수 상류 차분법의 개발)

  • Cho Ji Ryong
    • Journal of computational fluids engineering
    • /
    • v.4 no.1
    • /
    • pp.8-18
    • /
    • 1999
  • In devising a numerical approximation for the convective spatial transport of a fluid mechanical quantity, it is noted that the convective motion of a scalar quantity occurs in one-way, or from upstream to downstream. This consideration leads to a new scheme termed a pure upwind difference scheme (PUDS) in which an estimated value for a fluid mechanical quantity at a control surface is not influenced from downstream values. The formal accuracy of the proposed scheme is third order accurate. Two typical benchmark problems of a wall-driven fluid flow in a square cavity and a buoyancy-driven natural convection in a tall cavity are computed to evaluate performance of the proposed method. for comparison, the widely used simple upwind scheme, power-law scheme, and QUICK methods are also considered. Computation results are encouraging: the proposed PUDS sensitized to the convection direction produces the least numerical diffusion among tested convection schemes, and, notable improvements in representing recirculation of fluid stream and spatial change of a scalar. Although the formal accuracy of PUDS and QUICK are the same, the accuracy difference of approximately a single order is observed from the revealed results.

  • PDF

The Effects of Human Follicular Fluid on Embryonal Development of Mouse in In Vitro Culture (체외배양에서 인간 난포액이 생쥐의 배 발달에 미치는 영향)

  • Min, Bu-Kie;Choi, Ki-Wook;Kim, Kie-Suk;Lee, Hee-Sub;Hong, Ki-Yeon;Lee, Bong-Ju;Lee, Sun-Young;Park, Seung-Teak
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.26 no.2
    • /
    • pp.171-178
    • /
    • 1999
  • The follicular fluid (FF) of ovary contains various biological active products which affected on the growth of follicles and the fertilization of oocyte in physiological reproductive process of mammals. This study was designed to determine the effects of human FF on fertilization of oocyte and embryonal development in vitro culture. The FF was prepared as clear without blood contamination by needle aspiration from mature follicles of human at the time of oocytes retrieval for in vitro fertilization (IVF). As the medium for culture in vitro of embryonal cells, human tubal fluid (HTF) supplemented with follicular fluids at concentrations of 10%, 40% and pure FF were used. These effects were compared to control group of cultured embryos in HTF supplemented with 0.4% BSA (bovine serum albumin). For IVF, 64 eggs in control group, 67 eggs in 10% FF, 57 eggs in 40% FF and 64 eggs in pure FF were respectively allocated. And the rates of fertilization were almost similar in all groups as resulting 82.81% in control, 85.07% in 10% FF, 87.71% in 40% FF and 81.25% in pure FF. On the examination for embryonal cleavage from fertilized eggs, the rates of developing to 4 cell stage was similar in all groups, as results 98.11% in control, 98.27% in 10% FF and 98% in 40% FF but 78.84% in pure FF. And the rates of developing to 8-16 cell stage were significantly reduced as 44% in 40% FF and 44.23% in pure FF (p<0.05) compare to 71.69% in control media. As likewise, the rates of developing to morular stage were also significantly reduced to 36% (p<0.05) and 21.15% (p<0.01) respectively in 40% FF and pure FF. And the rates to blastocystic stage of embryo was lowest as 7.69% in pure FF (Table 1). The quality of embryonal cells on cleavage to the 8-16 cell stage was poorer, higher concentrations of FF. The rates of grade 1 in pure FF, as 23.07%, was lowest compare to those of other groups, in which the rates of grade 1 in control, 10% FF and 40% FF were 58.49%, 47.36% and 34% respectively. And on the contrary, the rate of grade 4 in pure FF was highest as 23.07%, while those were 5.66% in control, 8.77% in 10% FF and 20% in 40% FF (Table 2). On the viability of embryos, the rate of embryonal cell death was more rise, at the higher concentrations as well as longer exposure in the follicular fluid. At 48 hours after in vitro culture of embryos, the rate of survival embryos in pure FF was markedly lowered as 44.23%, compare to that of control (p<0.05). But there was not significant difference between the rates of survival embryos in each group beside the pure FF, which the rates were 77.35% in control, 70.17% in 10% FF and 60% in 40% FF respectively. And at 72 hours after in vitro culture, the rates of survival embryos were also significantly dropped to 21.15% in pure and 36% in 40% at concentration of FF compare to 62.26% in control (p<0.05, p<0.01). Finally, the rate of embryonal death at 96 hours after in vitro culture was highest as 82.69% in pure FF among all groups which those were 35.84 in control, 56.14% in 10% FF and 64% in 40% FF respectively (Fig. 1, 2, 3). In conclusion, this study suggests that the FF has no effects, in particular, to the in vitro fertilization of oocytes but exerted a bad effect to the cleavage, quality and viability of the embryonal cells during in vitro culture. However, the FF is harmful on embryonal development at conditions in higher concentration and especially on the embryos after $8{\sim}16$ cell stage.

  • PDF

ON PSEUDO SEMI-PROJECTIVE SYMMETRIC MANIFOLDS

  • De, Uday Chand;Majhi, Pradip
    • Journal of the Korean Mathematical Society
    • /
    • v.55 no.2
    • /
    • pp.391-413
    • /
    • 2018
  • In this paper we introduce a new tensor named semi-projective curvature tensor which generalizes the projective curvature tensor. First we deduce some basic geometric properties of semi-projective curvature tensor. Then we study pseudo semi-projective symmetric manifolds $(PSPS)_n$ which recover some known results of Chaki [5]. We provide several interesting results. Among others we prove that in a $(PSPS)_n$ if the associated vector field ${\rho}$ is a unit parallel vector field, then either the manifold reduces to a pseudosymmetric manifold or pseudo projective symmetric manifold. Moreover we deal with semi-projectively flat perfect fluid and dust fluid spacetimes respectively. As a consequence we obtain some important theorems. Next we consider the decomposability of $(PSPS)_n$. Finally, we construct a non-trivial Lorentzian metric of $(PSPS)_4$.