• Title/Summary/Keyword: Pupil Size

Search Result 106, Processing Time 0.032 seconds

Diameter of the retinal blur circle in a artificial hypermetropia (인워적 원시에 따른 망막에서 착란원 크기)

  • Choi, Woon Sang;Kim, Yoon-Kyung;Oh, Heung Geun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.2
    • /
    • pp.145-149
    • /
    • 2005
  • In a artificial hypermetropia with the accommodative response, we investigated a diameter of blur circle as a function of test lens refractive power. In a schematic eye model of the hypermetropia, the second focal length along to accommodated power of the crystal lens are calculated as a function of test lens power and, also distance between the retina and exit pupil are calculated as a function of accommodated power. As these results are compared, the size of blur circle on the retina are obtained.

  • PDF

General Pharmacology of $^{13}C$-Urea Powder Preparation in ${Helikat}^{TM}$

  • Lee, Eun-Bang;Cho, Sung-Ig;Jung, Chun-Sik
    • Biomolecules & Therapeutics
    • /
    • v.6 no.4
    • /
    • pp.406-411
    • /
    • 1998
  • The pre-mixed $_{13}C$-urea powder preparation in ${Helikit}_{TM}$ for test of Helicobacter pylori was evaluated for pharmacological properties. The oral doses of the preparation used in mice were 30-fold as compared to human doses. The results obtained in the present study demonstrate that spontaneous movement, hexobarbital-induced hypnosis, rotarod performance, body temperature, acetic acid-induced writhing syndrome, chemical and electroshock convulsion, pupil size and intestinal propulsion had not been affected at the oral doses of 230, 700 and 2100 mg/kg in mice. The blood pressure was slightly elevated as given intravenously in rats at a dose of 5 mg/kg of the preparation, but respiration was not influenced at the dose. In isolated guinea pig ileum and rat fundus preparation, the preparation at a concentration of $1{\times}10^{4}$ g/ml neither caused any direct effect nor inhibited the contraction produced by acetylcholine, histamine or 5-hydroxytryptamine. These results reported here provide evidence that pre-mixed $^{13}C$ 13/C-urea powder preparation is free of general pharmacological properties performed in oral administration.

  • PDF

Robust-to-rotation Iris Recognition Using Local Gradient Orientation Histogram (국부적 그래디언트 방향 히스토그램을 이용한 회전에 강인한 홍채 인식)

  • Choi, Chang-Soo;Jun, Byoung-Min
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.3C
    • /
    • pp.268-273
    • /
    • 2009
  • Iris recognition is a biometric technology which can identify a person using the iris pattern. It is important for the iris recognition system to extract the feature which is invariant to changes in iris patterns. Those changes can be occurred by the influence of lights, changes in the size of the pupil, and head tilting. In this paper, we propose a novel method based on local gradient orientation histogram which is robust to variations in illumination and rotations of iris patterns. The proposed method enables high-speed feature extraction and feature comparison because it requires no additional processing to obtain the rotation invariance, and shows comparable performance to the well-known previous methods.

Subarachnoid Morphine for Perianal Postoperative Pain Control (미양(微量) Morphine 지주막하(蜘蛛膜下) 주입(注入)에 의(依)한 항문각위술후(肛門脚圍術後) 제통효과(除痛效果)에 대(對)한 임상연구(臨床硏究))

  • Rhim, Hwa-Taeg;Lee, Yeong-Sik;Oh, Hung-Kun
    • The Korean Journal of Pain
    • /
    • v.1 no.1
    • /
    • pp.98-102
    • /
    • 1988
  • In order to control the pain after hemorrhoidectomy and anal fistulectomy, 6 mg of 0.5% hyperbaric tetracaine without(control, group I) or wilt 0.3 mg(group II) or 0.5 mg (group III) of 0.1% morphine was injected with a 22 gauge spinal needle into the subarachnoid space through L 3-4 interspace of patients in lateral position. About 30 minutes in Fowler' sposition after injection, operation was performed in lithotomy position. All the patients who ha4 morphine showed remarkable relief of postoperative pain for an average of 27 hours. However, the dosage(0.3 or 0.5 mg) of morphine administered did not affect the duration of pain relief. Blood pressure, pulse rate and pupil size were unchanged in all patients. Dysuria after block developed for on average of 5,6, 13.2 and 14.6 hours in group I, II and III respectively. Most of these cases required urethral catheterization. Minor complications such as nausea, vomiting, itching, fever, burning sensation and paresthesia were observed 16.7, 20 and 20% of cases in group I, II and III respectively; however, no treatment was required.

  • PDF

Binocular Holographic Three-Dimensional Imaging System Using Optical Scanning Holography (광 스캐닝 홀로그래피를 이용한 양안식 3차원 홀로그래픽 영상 시스템)

  • Kim, You Seok;Kim, Taegeun
    • Korean Journal of Optics and Photonics
    • /
    • v.26 no.5
    • /
    • pp.249-254
    • /
    • 2015
  • In this paper we propose a binocular holographic three-dimensional (3D) imaging system using optical scanning holography. To realize a binocular 3D holographic imaging system, we could acquire the complex holograms of a real object after designing a holographic display system based on interpupillary distance and pupil size, and these holograms could be optically reconstructed following numerical signal processing with an amplitude spatial light modulator. The proposed binocular 3D holographic imaging system using optical scanning holography was verified experimentally.

A Presumption of Water Supply Amount for Calculation of Equipment Capacity in High School Building (고등학교 건축물의 장비용량 산출용 급수량 추정)

  • Park Yool;Lee Hak-Soo;Lee Sung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.10
    • /
    • pp.768-775
    • /
    • 2006
  • The water supply system has been designing by decision process such as calculation of water supply amount, capacity of water tanks and pumps, pipe size. Especially, when we estimate excessively water supply amount, the initial cost and running cost will increase according to enlargement of the water tank and pump capacity, and water quality of ground water tank can become worse. Therefore, calculation of water supply amount is basically most important factor. In order to calculate exactly water supply amount applying domestic real situation, we should set up basic data as well as study calculation methods. This research would consider calculation methods of water supply amount for school building through examine domestic and foreign basic data of water supply amount and characteristics of domestic school, and estimate daily water supply in high school.

Visual Perception Experiment Study on the Brand Effect - Comparison of Domestic and Imported Car Brand -

  • Im, Hajin;Kim, Chiyoung;Kim, Soojung;Yu, Sooyeon;Kwon, Mahnwoo
    • Journal of Korea Multimedia Society
    • /
    • v.24 no.1
    • /
    • pp.146-154
    • /
    • 2021
  • Conspicuous consumption is often investigated in Korea and consumers purchase a product to publicly display economic power or social status. The existing studies argue that brand loyalty and luxury brand preferences escalate conspicuous consumption, and it is important to identify different visual perception to understand irrational consumers' behavior. Car emblem as brands' visual identity represents the brand's image, mission and message. Irrational consumers thus are expected have different visual perception to the emblem or logo. To understand the impact of irrational consumer behavior on visual perception, this study explored how brand loyalty and luxury brand preferences impact on the visual perception of car emblems between Korean domestic brand and imported brand. This study used eye tracking technology to measure the respondents' attention on an emblem of the cars. Eye tracking tools analyze fixations and measure the attention on a specific area of interests (AOI). This study explored the maintaining time and frequency on AOI, as well as explored the size of pupil to identify the respondents' attention on the AOI. In this experiment, the logos of domestic cars (i.e., Hyundai and Kia) and foreign cars (i.e., Mercedes-Benz and BMW) were swapped to see how irrational consumer behavior impact on visual perception of car emblem.

Optomechanical Design and Structural Analysis of Linear Astigmatism Free - Three Mirror System Telescope for CubeSat and Unmanned Aerial Vehicle

  • Han, Jimin;Lee, Sunwoo;Park, Woojin;Moon, Bongkon;Kim, Geon Hee;Lee, Dae-Hee;Kim, Dae Wook;Pak, Soojong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.1
    • /
    • pp.38.3-38.3
    • /
    • 2021
  • We are developing an optomechanical design of infrared telescope for the CubeSat and Unmanned Aerial Vehicle (UAV) which adapts the Linear Astigmatism Free- Three Mirror System in the confocal off-axis condition. The small entrance pupil (diameter of 40 mm) and the fast telescope (f-number of 1.9) can survey large areas. The telescope structure consists of three mirror modules and a sensor module, which are assembled on the base frame. The mirror structure has duplex layers to minimize a surface deformation and physical size of a mirror mount. All the optomechanical parts and three freeform mirrors are made from the same material, i.e., aluminum 6061-T6. The Coefficient of Thermal Expansion matching single material structure makes the imaging performance to be independent of the thermal expansion. We investigated structural characteristics against external loads through Finite Element Analysis. We confirmed the mirror surface distortion by the gravity and screw tightening, and the overall contraction/expansion following the external temperature environment change (from -30℃ to +30℃).

  • PDF

A Case of Delayed Administration of Naloxone for Morphine Intoxicated Patient (Morphine 과량복용 후 중독증상을 보인 환자의 지연된 Naloxone 치료 1례)

  • Kim, Gun-Bea;Park, Won-Nyung;Gu, Hong-Du
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.10 no.1
    • /
    • pp.33-36
    • /
    • 2012
  • Opioids are the one of the most commonly used drugs to control cancer pain all over the world. But, we should not overlook the potential risk of opioid intoxication because they have well-known detrimental side effects. The opioid intoxication can be diagnosed thorough various clinical manifestations. The altered mental status, respiratory depression, and miosis is very representative clinical features although these symptoms don't always appear together. Unfortunately the opioid-toxidrome can be varied. A 42 years old man came to our emergency room after taking about 900 mg morphine sulfate per oral. He was nearly alert and his respiration was normal. Even though his symptoms didn't deteriorated clinically, serial arterial blood gas analysis showed increase in PaCO2. So we decided to use intravenous naloxone. Soon, he was fully awaked and his pupils size was increased. After a continuous infusion of intravenous naloxone for 2 hours, PaCO2 decreased to normal range and his pupil size also returned to normal after 12 hours. Though the levels of serum amylase and lipase increased slightly, his pancreas was normal according to the abdominal computed tomography. He had nausea, vomit, and whole body itching after naloxone continuous infusion, but conservatively treated. We stopped the continuos infusion after 1 day because his laboratory results and physical examinations showed normal. As this case shows, it is very important to prescribe naloxone initially. If you suspect opioid intoxication, we recommend the initial use of naloxone even though a patient has atypical clinical features. In addition, we suggest intranasal administration of naloxone as safe and effective alternative and it's necessary to consider nalmefene that has a longer duration for opioid intoxication.

  • PDF

A Study on Iris Recognition by Iris Feature Extraction from Polar Coordinate Circular Iris Region (극 좌표계 원형 홍채영상에서의 특징 검출에 의한 홍채인식 연구)

  • Jeong, Dae-Sik;Park, Kang-Ryoung
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.44 no.3
    • /
    • pp.48-60
    • /
    • 2007
  • In previous researches for iris feature extraction, they transform a original iris image into rectangular one by stretching and interpolation, which causes the distortion of iris patterns. Consequently, it reduce iris recognition accuracy. So we are propose the method that extracts iris feature by using polar coordinates without distortion of iris patterns. Our proposed method has three strengths compared with previous researches. First, we extract iris feature directly from polar coordinate circular iris image. Though it requires a little more processing time, there is no degradation of accuracy for iris recognition and we compares the recognition performance of polar coordinate to rectangular type using by Hamming Distance, Cosine Distance and Euclidean Distance. Second, in general, the center position of pupil is different from that of iris due to camera angle, head position and gaze direction of user. So, we propose the method of iris feature detection based on polar coordinate circular iris region, which uses pupil and iris position and radius at the same time. Third, we overcome override point from iris patterns by using polar coordinates circular method. each overlapped point would be extracted from the same position of iris region. To overcome such problem, we modify Gabor filter's size and frequency on first track in order to consider low frequency iris patterns caused by overlapped points. Experimental results showed that EER is 0.29%, d' is 5,9 and EER is 0.16%, d' is 6,4 in case of using conventional rectangular image and proposed method, respectively.