The Effect of Incoherent Pumping in Electromagnetically Induced Absorption (전자기 유도 흡수에서의 비결맞음 펌핑 효과)

  • Moon, Han-Sub;Kim, Sook-Yung;Kim, Kyung-Dae;Lee, Chung-Hee;Lee, Rim;Kim, Haeng-Hwa;Kim, Joong-Bok
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.5
    • /
    • pp.449-454
    • /
    • 2002
  • We have studied the effects of incoherent pumping on EIA at the transition between the $F_g=2$ ground state and the $F_e=3$ excited state in $^{85}Rb\;D_1$-line. Generally, the studies about EIA have been done in the cycling transition, where the population has no loss to other states. In the case of EIA by using the $^{85}Rb\;D_1$ transition line, the population is transferred to the other hyperfine state due to optical pumping. We incoherently pumped the atoms from $F_g=3\;to\;F_g=2$ with the pumping beam, which is resonant at the transition from $F_g=3\;to\;F_g=2$. We were able to observe the effects of incoherent pumping depending on the power and the polarization of the pumping beam.

Second Harmonic Generation of Low Power Laser Diode Using a Ring Enhancement Cavity (고리형 Enhancement Cavity 를 이용한 저출력 반도체 레이저의 제2조화파 발생)

  • 오차환
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.2
    • /
    • pp.206-211
    • /
    • 1993
  • We carried out the second harmonic generation of low power CW laser diode with maximum power of 30 mW in $LilO_3$ crystals. We used a ring enhancement cavity to increase the second harmonic conversion efficiency. The ring enhancement cavity was Composed of two flat mirrors and two concave mirrors. The focal length of concave mirrors was 25 mm, and 5 mm long and 10 mm long $LilO_3$ crystals were used. We measured the second harmonic power according to the pumping power and compared with theoretical value. We obtained 397 nm second harmonic power of about $6.6{\mu}W$ in 10 mm long $LilO_3$ crystal with the fundumental 794 nm pumping power of 28 mW.

  • PDF

MPPT Control of PV Water Pumping Using BLDC Motor-Inverter (BLDC 모터용 인버터를 이용한 PV 양수펌프의 MPPT 제어)

  • 김성남;백승길;조정민;이승환;오봉환;이훈구;한경희
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.6
    • /
    • pp.498-505
    • /
    • 2001
  • This paper shows how to design a global control of water pumping system using PV array, and tracked maximum power point of PV array only the inverter using the vector control of BLDC motor, and finding the relationships among the DC magnitudes and AC ones in order to omit the DC/DC converter. Conventional MPPT controller was unstable of reason of the ripple-current of DC link in three-phase invertor. Thus, in this paper the control algorithm of BLDC motor using $i_qs$ current is composed to improve the insecurity of conventional MPPT controller To prove the excellence of the proposed method, the contents of this paper is analyzed by means of simulation and testing for the results applying the method that J. A Domfnguez had applied to asynchronous motor to BLDC motor and that of the proposed method in this paper.

  • PDF

A Study on the Flow Characteristic for Changing of Flow Region of the Motor Inserted Oil Pump (내부 유로 변경에 따른 전동기 일체형 유압펌프 내부의 유동특성에 관한 연구)

  • Choi, Y.H.;Lee, T.K.;Lee, Y.W.
    • Journal of Power System Engineering
    • /
    • v.16 no.5
    • /
    • pp.26-31
    • /
    • 2012
  • A numerical study has been carried out to investigate the heat and mass transfer of an oil pumping system with a variable shape of the housing using the CFD method. Especially, the electric motor and the pump combined together, accomplishes a research about the oil supplying system. In this study, the temperature and velocity distribution of the oil pumping system by varying the flow rate of supplying oil have been investigated. The temperature changes with each five conditions(flow rate of supply oil : 2, 4, 8, 12, and 16 liter/min) have also been studied. The numerical results show that the exhaust temperature decreases as the flow rate of the supplying oil increases. It also reveals that the temperatures change differently with the housing shape.

A study on the Detection of Premature Quench Generated in the Process of Current Pumping in a Superconducting Power Supply (초전도 Power Supply의 전류펌핑 과정에서 발생하는 조기 퀜치발생 진단)

  • Kim, Ho-Min;Bae, Joon-Han;Noh, Jeong-Sub;Sim, Ki-Deok;Jang, Won-Kap;Ko, Tae-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.244-246
    • /
    • 1997
  • This paper is to analyze the Premature Quench characteristics of a rotating magnet type superconducting fluxpump and consider the method of detecting and protecting this premature quench. Practically, there is contact resistance between the fluxpump and the load, namely the S.C. magnet. The thermal increase due to the contact resistance cause the premature quench before the charging current amounts to the critical current of S.C magnet. Therefore, this paper is devoted to solving the heat equation on contact region using cylindrical coordinates and to calculating the rate of thermal increase during the current is pumped up. Doing so, the predictive value of the maximum pumping current is obtained. It has been verified that the results of simulation are coincident with those of experiment. It must be considered essentially to minimize the contact resistance in designing the S.C fluxpump system in order to protect the premature quench and improve the maximum pumping current.

  • PDF

Hydraulic Pumps Driven by Multilayered Piezoelectric Elements -Mathematical Model and Application to Brake Device -

  • Konishi, Katunobu;Ukida, Hiroyuki;Sawada, Koutarou
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1998.10a
    • /
    • pp.474-479
    • /
    • 1998
  • In this paper, we present a mathematical model of the piezoelectric pump and its application to the automobile brake system. The piezoelectric pump consists of a multi-layered piezoelectric element a diaphragm, pumping values, resonant pipes and accumulators, and the maximum pumping power of 62W nab obtained in the previous experiments by using the piezoelectric element of 22mm diameter and 55.5mm length. A detailed mathematical model of the pump is derived here by considering the compressibility of the working oil, nonlinear characteristics of piezoelectric element, the time delay of pumping values' action and be on. The validity of the model is illustrated by comparing the experimental data and the simulation results. Using the mathematical model of the piezoelectric pump, a brake system for automobile disk brake is also simulated in this paper. The brake system consists of a piezoelectric pump as a power source, calipers and its piston to generate brake force, and a three position solenoid value to change the brake situation. It is shown that 15mm/sec of piston speed and 20kN of piston force are obtained by using the piezoelectric element of 33mm diameter and 55.5mm length.

  • PDF

Technology Trends in Vacuum Pumping

  • Ormrod, Stephen
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.59-59
    • /
    • 2012
  • Vacuum pumping remains central to the performance and economy of many manufacturing processes, scientific instruments and scientific research. More vacuum is being used in many of the latest or leading edge manufacturing processes: Current examples include 3D semiconductor devices, EUV lithography, 450 mm silicon wafers, AMOLED displays, LEDs, Lithium-ion batteries and steel degassing. In other applications, vacuum pumping technology developments have led to much lower product costs which for example have enabled mass spectrometers to become a ubiquitous tool is life science research. Vacuum pumps have continuously evolved during the past 100 years of vacuum-based industrial processing but remain a key component which is often on the critical path of process and product improvements. This is especially so in the growing number of applications where the pumps are highly stressed. This presentation outlines significant developments in vacuum that have brought about this progress. The likely course of continued improvements is discussed in terms of increased performance and reliability, robust by-product handling, better cost efficiency and reduced environmental impact especially power consumption.

  • PDF

Flow Rate Characteristics of Two Parallel Pumping System (두 대의 펌프가 병렬로 설치되는 계통에서의 유량 특성)

  • Park, Y.C.;Chi, D.Y.;Seo, K.W.;Yoon, H.G.;Park, J.G.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.579-586
    • /
    • 2011
  • During a reactor normal operation, a primary coolant was designed to remove the fission reaction heat of the reactor. When one pump is failure and the other pump shall supply the cooling water to cool the reduced power, it is necessary to estimate how much flow will be supplied to cool the reactor. We carried a flow net work analysis for two parallel pumping system as based on the piping net work of the primary cooling system in HANARO. As result, it is estimated that the flow of one pump increased than the rated flow of the pump below the cavitation critical flow.

  • PDF

Ultrasonic Engancement of Flow in Clayey Sands (점토질 모래에서의 Ultrasonic을 이용한 투수성의 증진)

  • 이광열
    • Water for future
    • /
    • v.26 no.1
    • /
    • pp.63-69
    • /
    • 1993
  • Remediation technology becomes an issue in environmental engineering. The vibro-recovery technique is one of popular means to remove pollutants from contaminated soils and groundwater. Using Ultrasonic excitation in soil-fluid medium, it was found that removal efficiency in a mechanical effects was significant. In this paper, therefore, laboratory experiments were conducted on clayey sand soil columns using a probe-type ultrasonic processor. Ultrasonic treatment with simultaneous pumping enhances dislodgement of clay particles, and ultrasonic excitation reduced the proportions of finer particles and thus result in increased hydraulic conductivity significantly. Also, the results provided the changes in grain size distribution curve of the soil due to ultrasonic excitation. The results indicated that the maximum size of particles mobilized by Ultrasonic is about 0.004mm and particles in the size range from 0.04mm to 1.0mm were subjected to fracturing. The economic feasibility of Ultrasonic implementation is considered in power requirement of the generator and maintenance of the horn. At a specified amplitude of vibrations, the power requirement of the generator depends on overburden pressure of the horn, temperature and viscosity of fluid in the soil medium. For comparisons, the requirement of a one inch and two inch diameter horn sonicators are compared with the power required for pumping water from different depths.

  • PDF

Operating Characteristics of Low Vacuum Pumps (저진공 펌프의 운전 특성)

  • 임종연;심우건;정광화
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.2
    • /
    • pp.93-104
    • /
    • 2003
  • For evaluation of durability of low vacuum pumps, it is required to examine the performance and degradation of low vacuum pumps. Pump degradation may result from abnormalities associated with the performance in many areas of pump operation. The diagnostics method can be used to monitor the pump performance in the semi-conductor process line. Based on the mechanical defect of the pump, the dynamic response and reliability of the system for performance test, and the dynamic characteristics of the pump were experimentally assessed. The theoretical work rate for the compression process in the pump was calculated, and then the efficiency of the pump associated with the power consumption was evaluated. This analysis will be useful in detecting pump degradation with increasing the power consumption. To determine the predominant factors of pump degradation, it is important to evaluate the entire pumping system. We studied vibration, dynamic pressure, pumping speed, and power consumption of low vacuum pumps. Our results can be utilized for the future research on the evaluating technology of durability of low vacuum pumps.