• Title/Summary/Keyword: Pumping phase

Search Result 85, Processing Time 0.027 seconds

A Design of High-Frequency Oscillatory Ventilator Using Phase Lock Loop system (위상동기루프 방식을 이용한 고빈도 진동환기 장치의 설계)

  • Lee, Sang-Hag;Jeong, Dong-Gyo;Lee, Joon-Ha;Lee, Kwan-Ho;Kim, Young-Jo;Chung, Jae-Chun;Lee, Hyun-Woo;Lee, Suck-Kang;Lee, Tae-Sug
    • Journal of Yeungnam Medical Science
    • /
    • v.6 no.2
    • /
    • pp.217-222
    • /
    • 1989
  • In this study, high frequency oscillatory ventilator was designed and constructed. Using designed by phase-lock loop system, in order to accurately and easily treat both the outlet volume and rpm. A system has been designed and is being evaluated using CD4046A PLL IC. We use this PLL IC for the purpose of motor controls. The device consists of PLL system, pumping mechanism, piston, cylinder, and special crank shaft are required. This system characteristics were as follows : 1) Frequency : 20-1800rpm. 2) Outlet air volume : 1-50cc.

  • PDF

Expert System for Emergency Decision Making for Metro Water Supply Systems (광역상수도 시설의 비상시 의사결정을 위한 전문가시스템)

  • Kim, Eung Seok;Kim, Joong Hoon;Baek, Chun Woo;Lee, Jung Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.1
    • /
    • pp.103-110
    • /
    • 2007
  • An efficient operational strategy using expert system for metro water supply systems in case of emergency situations is developed in this study. The emergency situations of the water supply systems are classified into three categories : pipeline system accident, machinery and electric facility accident and water quality accident. A PC-based expert system is developed using CLIPS for Seoul metro water supply system, Phase 1 & 2 system and Phase 3 & 4 system. Broad professional knowledges and experiences from the experts in the water supply systems have been collected systematically to construct the knowledge base. Decision-making in case of an emergency is based upon the professional knowledge so that a rational and efficient operational management can be available even in the absence of experienced expert. Especially the expert model developed in this study also provides a guide for pumping operation in case of pipeline accident to confirm that the proper pressure to all nodes in the system is supplied. The pipe network simulator KYPIPE has been consecutively executed by trial and error fashion for each pipeline in the system. The results from KYPIPE were included in the knowledge base to supplement the knowledge of the field engineers.

A Study on the Drag Reduction by an Additives in Cylindrical Vertical Tube (수직원형관에서 첨가제에 따른 마찰저항 감소에 관한 연구)

  • Cha, K.O.;Kim, J.G.
    • Solar Energy
    • /
    • v.20 no.2
    • /
    • pp.85-96
    • /
    • 2000
  • When the liquid with the additive of ppm unit of a polymer flows, the pressure drop can be manifestly decreased compared to that of pure liquid: that's the drag reduction. This method is that a small amount of a polymer which doesn't make the transformation of the properties of the working fluid is dissolved into the working fluid, the links of chains of the polymer do a buffer action to the molecules of the working fluid which come out between near the wall of the pipe and the interface, so that the pressure drop is dramatically decreased. When we transport the fluid, therefore, we can save a lot of pumping power, or we can increase the transportation capacity with using the same transportation equipment. But when a polymer solution is also flowing in the fluid transportation system, the degradation which have a very close relation with the phenomena of the drag reduction occurs necessarily. When adding polymer to reduce the drag in two phase flow system, It is impossible to find some studies. This study is focussing on a searching examination for the experimental study considering the mechanical degradation in the closed tow phase system to find out the conditions which could improve the pump capacity.

  • PDF

The Experimental Research on Periodic Airflow in Human Nasal Cavity (비강내 주기유동장의 실험적 해석에 관한 연구)

  • Shin, Sok-Jea;Kim, Sung-Kyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.1 s.232
    • /
    • pp.103-109
    • /
    • 2005
  • Airflow in the nasal cavity of a normal Korean adult is investigated experimentally by tomographic PIV measurement. Knowledge of airflow characteristics in nasal cavities is essential to understand the physiology and pathology aspects of nasal breathing. Several studies have utilized physical models of the healthy nasal cavity to investigate the relationship between nasal anatomy and airflow. All of these researches on nasal airflow are under the condition of constant flow-rate. In this study, nasal cavity flow with the physiological period is investigated by tomographic PIV, for the first time. A pumping system that can produce the periodic flow is created. Thanks to a new method for the model casting by a combination of the rapid prototyping and curing of clear silicone, a transparent rectangular box containing the complex nasal cavity can be made for PIV, The CBC PIV algorithm is used for analysis. Phase-averaged mean and RMS velocity distributions are obtained for inspirational and expiration nasal airflows. The comparison with the constant flow case is appreciated. There exist many flow patterns depending on each phase.

High-Efficiency Charge Pump for CMOS Image Sensor (CMOS 이미지 센서를 위한 고효율 Charge Pump)

  • Kim, Ju-Ha;Jun, Young-Hyun;Kong, Bai-Sun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.5
    • /
    • pp.50-57
    • /
    • 2008
  • In this paper, a high-efficiency charge pump for use in CMOS image sensor(CIS) is proposed. The proposed charge pump pursues high pumping efficiency by minimizing the switching and reversion losses by taking advantage of operation characteristics of CIS. That is, the proposed charge pump minimizes the switching loss by dynamically controlling the size of clock driver, pumping capacitor, and charge transfer switch based on the operation phase of CIS pixel sensor. The charge pump also minimizes the reversion loss by guaranteeing a sufficient non-overlapping period of local clocks using a tri-state local clock driver adapting the schmitt trigger. Comparison results using a 0.13-um CMOS process technology indicate that the proposed charge pump achieves up to 49.1% reduction on power consumption under no loading current condition as compared to conventional charge pump. They also indicate that the charge pump provides 19.0% reduction on power consumption under the maximum loading current condition.

ANALYSES OF ANNULAR LINEAR INDUCTION PUMP CHARACTERISTICS USING A TIME-HARMONIC FINITE DIFFERENCE ANALYSIS

  • Seong, Seung-Hwan;Kim, Seong-O
    • Nuclear Engineering and Technology
    • /
    • v.40 no.3
    • /
    • pp.213-224
    • /
    • 2008
  • The pumping of coolant in a liquid metal fast reactor may be performed with an annular linear induction electro-magnetic (EM) pump. Linear induction pumps use a traveling magnetic field wave created by poly-phase currents, and the induced currents and their associated magnetic field generate a Lorentz force, whose effect can be the pumping of the liquid metal. The flow behaviors in the pump are very complex, including a time-varying Lorentz force and pressure pulsation, because an induction EM pump has time-varying magnetic fields and the induced convective currents that originate from the flow of the liquid metal. These phenomena lead to an instability problem in the pump arising from the changes of the generated Lorentz forces along the pump's geometry. Therefore, a magneto-hydro-dynamics (MHD) analysis is required for the design and operation of a linear induction EM pump. We have developed a time-harmonic 2-dimensional axisymmetry MHD analysis method based on the Maxwell equations. This paper describes the analysis and numerical method for obtaining solutions for some MHD parameters in an induction EM pump. Experimental test results obtained from an induction EM pump of CLIP-150 at the STC "Sintez," D.V. Efremov Institute of Electro-physical Apparatus in St. Petersburg were used to validate the method. In addition, we investigated some characteristics of a linear induction EM pump, such as the effect of the convective current and the double supply frequency (DSF) pressure pulsation. This simple model overestimated the convective eddy current generated from the sodium flow in the pump channel; however, it had a similar tendency for the measured data of the pump performance through a comparison with the experimental data. Considering its simplicity, it could be a base model for designing an EM pump and for evaluating the MHD flow in an EM pump.

A study on the Sensorless driving method of the SRM for Pumping system (펌프용 SRM의 Sensorless구동방식에 관한 연구)

  • Son, Dong-Hyeok;Moon, Ji-Woo;Cho, Yun-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2008.04c
    • /
    • pp.134-136
    • /
    • 2008
  • In recent years, the switched reluctance motor have been used many industrial application because of its cost advantage. SRM drivers are accomplished by switching the phase currents on and off synchronously with the rotor position which is fed back to the controller by position may deteriorate in harsh environments and increase the size and cost of the SRM drive system. This paper proposes a position sensorless method that is based on impressed pulse voltage using impressed at unenergised phases to estimate the rotor position. The current value by impressed pulse voltage compare with the threshold value. The rotor position can be estimated by observing the current value. Finally, simulation results compare with the sensor type SRM and confirm the proposed method to be useful.

  • PDF

Status of vacuum technique in KSTAR (KSTAR 토카막 장치 진공 기술 현황)

  • Kim, Kwang-Pyo;Kim, Hyun-Seok
    • Vacuum Magazine
    • /
    • v.4 no.1
    • /
    • pp.16-23
    • /
    • 2017
  • Recently, KSTAR, Korea's superconducting fusion energy research and development device, has succeeded in driving the high performance plasma for 70 seconds for the first time in the world. Continuous plasma operation technology is an essential factor for commercialization of fusion energy power generation. Therefore, this achievement is expected to play a major role in the research of fusion technology required for future fusion power plants. In order to operate the KSTAR, the discharge process in which the neutral gas is turned into the plasma should be preceded in the start-up (breakdown) phase of tokamak operation. This process essentially involves the vacuum environment in the tokamak device. KSTAR has successfully operated a vacuum pumping system to achieve the target level of the vacuum environment through a high temperature baking operation, a discharge cleaning process and boronization.

A Second-Order Analysis of VM Heat Pumps (VM열펌프의 2차해석)

  • Choi, Y.S.;Jeong, E.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.2
    • /
    • pp.208-218
    • /
    • 1996
  • Performance of a VM heat pump is considerably affected by various losses, such as enthalpy dump, reheat loss, pumping loss, conduction loss and shuttle loss. A second-order analysis model of VM heat pumps, which allows consideration of the major losses, was presented. Actual heat transfer rates for heat exchangers were calculated from the heat transfer rates obtained by the adiabatic analysis and various losses. New effective temperatures of heat exchangers were calculated from the actual heat transfer rates and the mean heat transfer coefficients until there was no appreciable change in the effective temperatures. Effects of design parameters, such as phase angle, swept volume ratio, regenerator length and speed on heating capacity, cooling capacity and COP were shown.

  • PDF

Compact green light sources for laser projection display

  • Ko, Do-Kyeong;Jung, Chang-Soo;Yu, Nan-Ei;Yu, Bong-Ahn;Lee, Yeung-Lak;Lee, Jong-Min
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1335-1336
    • /
    • 2008
  • A compact diode-pumped microchip(DPM) green light source which consist of pump LD, $Nd:YVO_4$, KTP and a built-in thermoelectric element has been fabricated for laser projection display. The volume of the source is as small as $0.7\;cm^3$ and we obtained the output power of 25mW with the average electric power consumption in pump LD of 304mW which correspond to the electrical-to-optical efficiency of 7.8%. Another approach using quasi phase matching(QPM) technique has been attempted. We obtained the output power of 90mW of green beam with 350mW pumping of a $Nd:YVO_4$ laser with 20-kHz rep. rate and 10-ns pulse duration. Detailed characteristics and issues of the DPM and QPM green light sources will be addressed.

  • PDF