• 제목/요약/키워드: Pulse types

검색결과 337건 처리시간 0.023초

Simulations for Square Pulse Generators

  • Jeong I. W.;Lee H. J.;Rim G. H.;Pavlov E. P.;Kim J. S.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.132-135
    • /
    • 2001
  • The design of square pulse generators using pulse forming lines (PFLs) made up of identical L and C, was reviewed in this study. 14 different types of PFLs were analyzed utilizing PSpice simulation results. These PFLs were characterized with respect to their distinct features: the number of forming lines (single or double), the circuit relationship between PFL and load (parallel or series), the types of energy storage (voltage source, current source or a combination of both). The characteristic impedances, output parameters such as pulse width, voltage and current magnitudes, and powers were derived for each scheme. The merits and demerits of the output parameters were also included.

  • PDF

실내 무선 채널에서 초광대역 무선통신 시스템의 성능 분석 (Performance Analysis of Ultra Wide Band Systems in Indoor Wireless Channel)

  • 김은철;우상규;양재수;김진영
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2008년도 정보통신설비 학술대회
    • /
    • pp.39-42
    • /
    • 2008
  • In this paper, we analyze the performance of ultra wide band (UWB) systems in indoor wireless channel in accordance with the number of pulses per bit at transmit signals and the decision types of receiver. The indoor channel is modeled as the modified Saleh and Valenzuela (SV) model which has been proposed as a UWB channel model by the IEEE group, IEEE 802.15.SG3a. Two types of UWB signals are considered One is the pulse position modulation-time hopping (PPM-TH) signal. And the other is the pulse amplitude modulation-direct sequence (PAM-DS) signal. It is assumed that the receiver is an ideal receiver which can receive all signals of the multipath.

  • PDF

삭맥(數脈)의 허실(虛實)과 미발현(未發現) (A Study on the Deficiency-excess Pattern of the Rapid Pulse)

  • 홍승민;박휘은
    • 한국한의학연구원논문집
    • /
    • 제16권3호
    • /
    • pp.33-44
    • /
    • 2010
  • Pulse diagnosis is considered one of the most important diagnostic methods in traditional Korean medicine. Nonetheless, there have been troubles of using pulse diagnosis practically, for the lack of its differential standards and standardized terminology. Rapid pulse belongs to the several traditional pulse types. Rapid pulse was first mentioned in the chinese medical book Haungdineijin that matched it to the fever as well as yang in the human body. Meanwhile, chinese doctors in Ming Ching dynasty of China suggested that rapid pulse meant more of the yin, cold-related reaction than yang and fever. In this study, we organized the past arguments of the rapid pulse and went back tracking what biological activities could be possibly linked to the rapid pulse. Thus, we figured out that the inflammatory mechanism has a close connection with the rapid pulse. The definition of the rapid pulse in Haungdineijin was indicating the acute inflammatory response, while in Ming Ching dynasty, it indicated the chronic inflammation. This is the deficiency-excess pattern of the rapid pulse. Furthermore, we discussed the nonexpression pattern of the rapid pulse which could be happened in case of the heat stroke, etc.

현맥의 특징에 대한 현대 의학적 고찰 (Modern Medical Scientific Study on the String Pulse)

  • 유현희;이전;전영주;이유정;이시우;김종열
    • 동의생리병리학회지
    • /
    • 제22권3호
    • /
    • pp.535-539
    • /
    • 2008
  • Pulse diagnosis is one of the typical examination methods in traditional oriental medicine. Pulse type classification is a major element of this diagnosis. There are more than 20 pulse types which have each clinical significance. However, pulse type's indications are implicative and obscure. In this study, we reviewed string pulse which is often diagnosed in Traditional Korean Medicine by analysis of Traditional Oriental Medical Literatures and modern medical papers. String pulse is taut and stiff pulse with high tension and low softness. It appears in 'blood vessel endothelial dysfunction', 'autonomic imbalance', 'arteriosclerosis'. Persistent string pulse can bring about cardiovascular or central nervous disease.

Suggestion for Objective Evaluation of Comparative Pulse Diagnosis

  • Jun-Sang Yu
    • 대한약침학회지
    • /
    • 제27권1호
    • /
    • pp.21-26
    • /
    • 2024
  • Objectives: Pulse is a method of Korean medicine diagnosis and is an important clue to detect the organs, nature, and progress of the disease. Pulse examination is included in the basic examination of Korean medicine doctors, but there is no standardized method for diagnosing pulse although the types and methods of the pulse taking are briefly described in the literature, making it difficult to spread the examination method. In this regard, I would like to propose an objective evaluation method. Methods: Although the importance of pulse examination and the method of pulse examination are known in the literature, it is difficult for undergraduate students or inexperienced Korean medicine doctors to access it, so in this paper a method of marking the size of the pulse power in the blank space for objective evaluation was devised and presented. Results: The size of the pulse power should be indicated using the 1-cell, 3-cell, or 5-cell method according to the left and right wrists and the cun, guan and chi on both sides. Conclusion: The method of pulse diagnosis is an important diagnostic method as a verification process for making a Korean medical diagnosis. The remaining Korean medicine diagnostic methods, including pulse diagnosis, also need to undergo objectification. It is believed that the objectification of these diagnostic methods will lead to an improvement in the treatment rate of Korean medicine.

Assessment of transient vibrations of graphene oxide reinforced plates under pulse loads using finite strip method

  • Mirjavadi, Seyed Sajad;Forsat, Masoud;Barati, Mohammad Reza;Hamouda, A.M.S.
    • Computers and Concrete
    • /
    • 제25권6호
    • /
    • pp.575-585
    • /
    • 2020
  • Based on a refined shear deformation finite strip, transient vibrations of graphene oxide powder (GOP) reinforced plates due to external pulse loads have been investigated. The plate has uniformly and linearly distributed GOPs inside material structure. Applied pulse loads have been selected as sinusoidal, linear and blast types. Such pulse loads result in transient vibrations of the GOP-reinforced plates which are not explored before. Finite strip method (FSM) has been performed for solving the equations of motion and then inverse Laplace transform technique has been employed to derive transient responses due to pulse loading. It is reported in this study that the transient responses of GOP-reinforced plates are dependent on GOP dispersions, GOP volume fraction, type of pulse loading, loading time and load locations.

Nd:YAG 레이저의 펄스 제어에 의한 마그네슘 합금 용접부의 결함 방지에 관한 연구 (Study of Defect Prevention on Weld Zone of Magnesium Alloy by Pulse Control of Nd:YAG Laser)

  • 김종도;이정한;김장수
    • 한국정밀공학회지
    • /
    • 제27권1호
    • /
    • pp.99-104
    • /
    • 2010
  • Magnesium and magnesium alloys, the lightest structural materials, have been received plenty of global attention recently. These alloys could be applied in various fields, especially the electronics industry, because of their excellent electromagnetic interference shielding. However, the welding technique of magnesium alloys has not been established. This study is related to the welding of AZ31B magnesium alloy by a short-pulsed a Nd:YAG laser. Two types of pulse waves, square pulse and variable pulse, were used to control weld defects. Results show that the crack and porosity, generated in the weld, had not been controlled by general square pulse. But through the application of variable pulse, the defects could be prevented and the good weld zone was obtained.

고령자 여성의 체질건강수준에 따른 맥파 특성 연구 (Characteristic Radial Pulse Properties of Elderly Females according to Sasang Constitution-based Health Level)

  • 김재욱;배장한;구본초;전영주;김근호;김종열;김영민
    • 동의생리병리학회지
    • /
    • 제26권6호
    • /
    • pp.970-975
    • /
    • 2012
  • In Sasang constitutional medicine, doctors diagnose and treat patients according to their Sasang consitutition (SC) type. In this work, by a clinical test with a radial pulse tonometer, we investigated radial pulse properties which were significant in distinguishing unhealthy subjects from healthy subjects for each SC type. We measured radial pulse properties on left and right Gwan locations with a pulse tonometer for 299 elderly female subjects of age of 50 years old or above. We used a newly developed SCAT system to determine subjects' SC types. Subjects' health levels of either healthy or unhealthy were determined independently by two Korean medical doctors. To investigate the statistical differences, we used either of Student's t-test or Mann-Whitney U test depending on the normality of distribution of test statistic. For TE type, unhealthy subjects were characterized with significant increases in heart rate, systolic to diastolic period, pulse depth, while they showed significant decreases in width of pulse in normal direction, pulse area in diastolic period, and high harmonic components (6th, 7th) of power spectral density. For SE type, unhealthy subjects were characterized with significant increases in pulse pressure and pulse depth, while no significant differences were found for SY type. We investigated the characteristic differences in radial pulse properties due to change in health levels on each SC type for elderly females. Pulse variables which were significantly different between healthy subjects and unhealthy subjects were found to vary between SC types. For TE type subjects, many variables were found significant at the left Gwan location, which is in support of the theory of hyperactive liver functioning for TE type. Irrespective of the constitution, the related changes in the pulse properties due to worsened health level were in support of elevated blood flow amount in compensation with weakened blood circulatory function.

5단계 가압에 대한 맥파 변화 분석에 의한 맥 패턴 분류와 부침맥(浮沈脈) 연구 (A study on floating and sinking pulse by classification of pulse pattern through analysis of P-H volume-curve at 5 applied pressure levels)

  • 권선민;강희정;임윤경;이용흠
    • Korean Journal of Acupuncture
    • /
    • 제27권1호
    • /
    • pp.13-22
    • /
    • 2010
  • Objectives: The information on the depth where pulse wave appears is as important as pulse waveform. The aim of this study was to classify pulse pattern using pressure-height(P-H) volume-curve by 5 applied pressure levels to find out the information on the depth of pulse and interpret the floating & sinking pulse in oriental medical pulse diagnosis. Methods: We used 3 dimensional pulse imaging analyser (DMP-3000, DAEYOMEDI Co., Korea), which measures radial pulse waveforms noninvasively by way of tonometric method at 5 applied pressure levels, and shows P-H volume-curves by applied pressure. 448 subjects were enrolled, pulse waveforms were measured and the P-H volume-curves were gained on the three locations of Chon, Kwan, and Cheok. Results: Gained P-H volume curves were classified into 3 types ; increase type, decrease type, and increase-decrease type. Increase-decrease type appeared more often on Chon and Kwan, while increase type appeared more often on Cheok. In a few cases, decrease-type appeared on Chon and Kawn, however it never appeared on Cheok. Conclusions: Through the classification of pulse by P-H volume-curve, we gained the information on the depth of pulse. We speculate the decrease type as floating pulse, the increase-decrease type as middle pulse, and the increase type as sinking pulse in oriental medical pulse diagnosis. After more researches on P-H volume-curve by applied pressure, the P-H volume-curve may be used as an important factor for pulse diagnosis.

펄스형성선로로 구성된 선형유도가속기용 양방향 펄스 전원 (Bidirectional pulse generator made from pulse forming lines for linear induction accelerator)

  • 박정호;김종해;고광철;강형부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1681-1683
    • /
    • 1997
  • Linear induction accelerator devised for high current beam accelerating is divided into two types. In the first type, a unidirectional pulse is injected to an accelerating gap and in the second type, a bidirectional pulse is injected. The purpose of this paper is design and manufacture of bidirectional pulse generator for linear induction accelerator, where the pulse width for acceleration is more than 50[nsee] and the designed maximum charging voltage is more than 200[kV].

  • PDF