• 제목/요약/키워드: Pulse time

검색결과 2,683건 처리시간 0.041초

USB Driver 전송시스템 기반의 맥파 측정 시스템에 관한 연구 (A Study on Pulse Wave Measurement System Based on USB Driver Transmission System)

  • 김은근;박미경;한승신;허영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1914-1915
    • /
    • 2007
  • The period and strength of the pulse on the radial artery are important physiological factors, and they have been used to diagnosis in both Western and Eastern countries for a long time and has been developed as a unique method of diagnosis at each countries. Recently, there are a lot of systems which can give diagnosis information by recording the pulse wave and analyzing the characteristics of the pulse shape. This study describes the Pulse-Wave Measurement System which is able to measure the pulse wave signal using piezoresistive sensor and the pulse wave signal measured by the developed system is transmitted to a computer on the basis of the USB Driver. It has finally shown the the pulse wave signal measured by the sender is appeared to the host PC in real time. The Pulse-Wave Measurement System used the piezoresistive sensor to measure the pulse wave signal and the differential amplifier(AD620) to amplify the pulse wave signal which is small signal. And it used the ADC to convert analog to digital for the measured analog signal and the interface with a computer. It transmitted the measured pulse signal through USB transmission module to the host computer and Labview tool shows it. This Pulse-Wave measurement system will afford comvenience of detecting pulse wave to user related to oriental medicine.

  • PDF

중첩펄스 전기집진기의 전력 및 집진특성 (Power and Collection Characteristics of Superimposed Pulse Electrostatic Precipitator)

  • 서경원;이창신;이정석;채재우
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권3호
    • /
    • pp.177-185
    • /
    • 2000
  • In this study, the characteristics of various electricity and high resistivity ash collection were measured at superimposed nanosecond pulse energization. The pulse was generated through the hydrogen thyratron. Superimposed pulse was nanosecond duration pulse that had fast pulse rising time 100[ns], short pulse width 500∼850[ns] and pulse fall time 400∼750[ns]. The results of this study are summarized as followings; Frist, compared with the DC ESP(electrostatic precipitator), superimposed pulse ESP could induce higher peak voltage, and had the about 30[%] reduction of ESP collection area and 50∼80[%] reduction of power consumption. showing the same efficiency. Second, enhancement factor H had 1.9∼3.6 with the increase of migration velocity.

  • PDF

일정 전기자극하의 근력 상승 - 전기 자극 파형의 펄스 진폭과 펄스폭에 대한 의존성 (Muscle Force Potentiation During Constant Electrical Stimulation - Dependence on Pulse-Amplitude and Pulse-Duration of Electrical Stimulation)

  • 김지원;강민영;엄광문
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제55권10호
    • /
    • pp.458-463
    • /
    • 2006
  • The purpose of this work is to investigate the fundamental properties of the gradual muscle force potentiation. We investigated the dependence of force potentiation on both the pulse-amplitude and the pulse-duration with different ramp-up time. The experimental results showed that the force increment ratio (FIR) during constant electrical stimulation decreased with pulse-amplitude and also with pulse-duration. The FIR was greater with short ramp-up time in both the pulse-amplitude and pulse-width modulation. The feasible mechanism might be that the myosin light chain phosphorylation induces the force potentiation and it occurs only in the fast type muscle fibers which are recruited first. These observations indicate that muscle potentiation must be understood well for the accurate control of muscle force.

능동적 다중 펄스 중첩법(AMPS)을 적용한 펄스형 $CO_2$ 레이저의 펄스 성형에 대한 연구 (A study on the pulse forming of pulsed $CO_2$ laser using active multi-pulse superposition)

  • 정현주;박성준;정용호;송건주;김희제;김휘영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1631-1633
    • /
    • 2001
  • In manufacturing processes, various and suitable pulse shapes are required for the purpose of material processing and the pulseshape is regarded as a dominant factor due to the specific property of processing materials. Therefore, in this study, a variable pulse width, high duty cycle Pulse Forming Network(PFN) is constructed by time sequently. The power supply for this experiment consists of three switching circuits. The PFN elements operate at low voltage and drive the primary of HV leakage transformer. The secondary of the transformer has a full-wave rectifier, which passes the pulse energy to the load in a continuous sequence of properly phased and nested increments. We investigated laser pulse width as various delay time among three switching circuit. As a result, we tan obtain various laser pulse width from about 4ms to 10ms. The maximum laser pulse width obtained at this experiment was about 10ms at delay time of 4ms among each switching circuit.

  • PDF

산삼 약침이 정상 중년여성의 맥파요인에 미치는 영향 (Effect of pulse-wave factors in Middle Aged Women by Mountain Cultivated Ginseng Pharmacopuncture Original Articles)

  • 박상욱;김이순;황원덕;김경철
    • 대한약침학회지
    • /
    • 제14권1호
    • /
    • pp.35-49
    • /
    • 2011
  • Objectives: The aim of this experiment is to know about Effect of pulse-wave factors in Middle Aged Women by Mountain Cultivated Ginseng Pharmacopuncture. Methods: First 20 Middle Aged women are diagnosed by pulse diagnosis, and then Mountain Cultivated Ginseng Pharmacopuncture(1 injection 20cc) were injected. 30 minutes later, pulse diagnosis again performed. As a result, method of one-group pretest-posttes design were used for evaluation. Results: T(Total pulse cycle) time statistically significant increased on both left and right chon, kwan, cheok. T4 time statistically significant increased on both left and right chon, kwan, cheok. T4-T1/T indexs except left cheokmaek, Right cheokmaek observation area decreased significantly in four sites. Wm(indicating high pressure retention time) indexs increased significantly in the five sites were observed except right chon maek. Conclusions: Effect of pulse-wave factors in Middle Aged Women by Mountain Cultivated Ginseng Pharmacopuncture increased T, T4, Wm and decreased T4-T1/T indexs. The results of this experiment, Mountain Cultivated Ginseng Pharmacopuncture induced to increase the Pulse-wave's stability and strength.

지능형 맥진기 구현 (Implementation of Intelligence Pulse Wave Detection System)

  • 홍유식;유준상;장세진;선승호;이우범;남동현;유문성;최명복;이상석
    • 한국인터넷방송통신학회논문지
    • /
    • 제13권2호
    • /
    • pp.245-254
    • /
    • 2013
  • 동양 의학에서는 맥파를 분석해서 많은 질병을 분류하고 치료하고 있다. 그러나 현재까지 맥파를 분석하는 방법은 매우 주관적인 방법을 사용하기 때문에 신뢰도가 떨어지는 문제점이 발생한다. 뿐만 아니라, 기존 맥진기의 문제점으로는 요골동맥에 정확하게 맥진 센서가 위치하지 못하기 때문에 측정 위치에 따라 측정결과가 상이하고 측정절차에 매우 민감하여 높은 재현성을 실현 못하고 있는 실정이다. 본 논문에서는 이러한 문제점을 해결하기 위해서 홀센서를 이용한 휴대용 맥진기를 이용해서 실맥 및 허맥을 분석 하는 연구 결과를 제안하였다. SPSS 통계 기법으로 분석한 실맥 및 허맥 최종 분석결과, 95% 신뢰도 구간에서 N.time(절흔점 시간) 및 S.amp (상승파형 크기) 평균치가 유의성이 있음을 입증하였다.

Long Pulse Generation Technology of an Alexandrite Laser System for Hair Removal

  • Kim, Hee-Je;Park, Jin-Young;Kwak, Su-Young;Kim, Su-Weon;Min, Byoung-Dae;Jung, Jong-Han;Hong, Jung-Hwan
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제3C권4호
    • /
    • pp.155-160
    • /
    • 2003
  • In this study, an Alexandrite laser system for hair removal adopting a multi-discharge method in which three flash lamps are turned on consecutively was designed and fabricated to examine the pulse width and the pulse shape of the laser beams depending upon the changes in the lamp turn-on time. Specifically, this study demonstrates a technology that makes it possible to formulate various pulse shapes by turning on three flashlamps consecutively on a real-time basis with the aid of a PIC (program integrated circuit) one-chip microprocessor. With this technique, the lamp turn-on delay time can be varied more diversely from 0 to 10 ms and real-time control is possible with an external keyboard, enabling an assortment of pulse shapes. In addition, longer pulses can be more widely used for industrial processing as well as for numerous medical purposes.

개선된 블록 펄스 계수 추정 기법을 이용한 선형 시불변계의 상태 추정에 관한 연구 (A Study on The State Estimation of The Time-Invariant Linear Systems via The Improved Parameter Estimation Method for The Block Pulse Coefficients)

  • 김태훈;김진태;정제욱;심재선
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제51권4호
    • /
    • pp.137-143
    • /
    • 2002
  • Because Block Pulse functions are used in a variety of fields such as the analysis and controller design of systems, it is necessary to find the more exact value of the Block Pulse series coefficients. This paper presents a method for the state estimation of the time-invariant linear systems via the improved estimation method for the Block Pulse coefficients by using the Simpson's rule. The proposed method using the Simpson's rule improve the accuracy of the Block Pulse coefficients.

W·Co의 함유량이 방전가공에 미치는 영향에 관한 연구 (A Study of Effect W·Co Content of Electrode in EDM)

  • 김용명;김희남
    • Design & Manufacturing
    • /
    • 제2권5호
    • /
    • pp.39-42
    • /
    • 2008
  • The Paper discussed the effects of working electric current and pulse when using super hardend alloy drill as corona electrode. The discharge effect can be obtained very precisely in the ranges of 1A - 2A in working current. $12{\mu}s-14{\mu}s$ in dis charge pulse on time width and $8{\mu}s-10{\mu}s$ in discharge pulse off time.

  • PDF

테이퍼형 마이크로스트립 전송선로에서 펄스 신호의 시간 영역 전송특성 해석 (Analysis of the Wave Propagation Characteristic for Pulse Signal on Tapered Microstrip Line in Time Domain)

  • 김기래;최영규
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권1호
    • /
    • pp.40-44
    • /
    • 2006
  • In this paper, the distortion characteristics of an electrical pulse which has a rise/fall time due to the dispersion and the reflection, on nonuniform tapered microstrip lines has investigated in time domain. The transmission characteristics on uniform microstrip lines in time domain had represented already, but the results for the nonuniform tapered microstrip lines not represented yet. We investigated the transmission characteristics for pulse signal on the nonuniform tapered microstrip lines, and the result applied to design of wide band impedance matching circuit in design of MMIC. The voltage and current transfer functions are shown for the tapered line. The dispersion and distortion obtained by using these transfer functions are represented for the nonideal square pulse.