• Title/Summary/Keyword: Pulse test

Search Result 1,181, Processing Time 0.033 seconds

Effect of Academic Examination Stress on Taste Perception and Nutrient Intake in University Students (대학생의 시험 스트레스가 미각과 영양소 섭취에 미치는 영향)

  • 전예숙;최미경
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.33 no.2
    • /
    • pp.349-355
    • /
    • 2004
  • The purpose of this study was to estimate effect of academic examination stress on taste perception and nutrient intakes in university students. Physical status, blood pressure, stress score using stress test of 2 types, recognition threshold and preference for taste, nutrient intakes using diet record method were measured before and after examination in 20 subjects. Mean age, height, weight, and BMI of the subjects were 23.39$\pm$1.20 years, 164.56$\pm$7.99 cm, 60.66$\pm$13.23 kg, 22.28$\pm$4.56 kg/$m^2$, respectively. Stress scores before examination of the subjects were significantly higher than those after examination. There were no significant differences in blood pressure, pulse rate, recognition threshold and just right concentration for sweetness and saltness, and food and nutrient intakes between pre- and post-examination. There were significantly positive correlation between stress score and diastolic blood pressure. And threshold concentration for saltness was positively correlated with threshold concentration for sweetness and animal protein intake. These results show no effect of examination stress on taste perception and nutrient intakes in university students. This may be due to low level of stress. Therefore, it is needed to study about effect of more higher level of stress on taste perception and nutrient intakes.

A Study on Usefulness of Specific Agents with Liver Disease at MRI Imaging: Comparison with Ferucarbotran and Gd-EOB-DTPA Contrast Agents (간 병변 특이성 조영제 자기공명영상에 대한 연구: Ferucarbotran과 Gd-EOB-DTPA 조영제의 비교)

  • Lee, Jae-Seung;Goo, Eun-Hoe;Park, Cheol-Soo;Lee, Sun-Yeob;Choi, Yong-Seok
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.235-243
    • /
    • 2009
  • The purpose of this experiment is to know the relation of the detection and characterization of liver's diseases as comparison of finding at MR imaging using a Ferucarbotran (SPIO) and Gd-EOB-DTPA (Primovist) agents in diffuse liver disease. A total of 50 patients (25 men and 25 women, mean age: 50 years) with liver diseases were investigated at 3.0T machine (GE, General Electric Medical System, Excite HD) "with 8 Ch body coil for comparison of diseases and contrast's uptake relation, which used the LAVA, MGRE." All images were performed on the same location with before and after Ferucarbotran and Gd-EOB-DTPA administrations (p<0.05). Contrast to noise ratio of Ferucarbotran and Gd-EOB-DTPA in the HCC were $3.08{\pm}0.12$ and $7.00{\pm}0.27$ with MGRE and LAVA pulse sequence, $3.62{\pm}0.13$ and $2.60{\pm}0.23$ in the hyper-plastic nodule, $1.70{\pm}0.09$ and $2.60{\pm}0.23$ in the meta, $2.12{\pm}0.28$ and $5.86{\pm}0.28$ in the FNH, $4.45{\pm}0.28$ and $1.73{\pm}0.02$ in the abscess and ANOVA test was used to evaluate the diagnostic performance of each disease (p<0.05). In conclusions, two techniques were well demonstrated with the relation of the detection and characterization of liver's diseases.

  • PDF

Predicting Migration of a Heavy Metal in a Sandy Soil Using Time Domain Reflectometry (TDR을 이용한 사질토양에서의 중금속 이동 추정)

  • Dong-Ju Kim;Doo-Sung Baek;Min-Soo Park
    • Journal of Korea Soil Environment Society
    • /
    • v.4 no.1
    • /
    • pp.109-118
    • /
    • 1999
  • Recently, transport parameters of conservative solutes such as KCl in a porous medium have been successfully determined using time domain reflectometry (TDR) . This study was initiated to Investigate the applicability of TDR technique to monitoring the fate of a heavy metal ion in a sandy soil and the distribution of its concentration along travel distance with time. A column test was conducted in a laboratory that consists of monitoring both resident and flux concentrations of $ZnCl_2$in a sandy soil under a breakthrough condition. A tracer of $ZnCl_2$(10 g/L) was injected onto the top surface of the sample as pulse type as soon as a steady-state condition was achieved. Time-series measurements of resistance and electrical conductivity were performed at 10 cm and 20 cm of distances from the inlet boundary by horizontal-positioning of parallel TDR metallic rods and using an EC-meter for the effluent exiting the bottom boundary respectively. In addition. Zn ions of the effluent were analyzed by ICP-AES. Since the mode and position of concentration detected by TDR and effluent were different, comparison between ICP analysis and TDR-detected concentration was made by predicting flux concentration using CDE model accommodating a decay constant with the transport parameters obtained from the resident concentrations. The experimental results showed that the resident concentration resulted in earlier and higher peak than the flux concentration obtained by EC-meter, implying the homogeneity of the packed sandy soil. A close agreement was found between the predicted from the transport parameters obtained by TDR and the measured $ZnCl_2$concentration. This indicates that TDR technique can also be applied to monitoring heavy metal concentrations in the soil once that a decay constant is obtained for a given soil.

  • PDF

Measuring the Third-Person Effects of Public Opinion Polls: Focusing On Online Polls (여론조사보도에 대한 제3자효과 검증: 온라인 여론조사를 주목하며)

  • Kim, Sung-Tae;Willnat, Las;Weaver, David
    • Korean journal of communication and information
    • /
    • v.32
    • /
    • pp.49-73
    • /
    • 2006
  • During the past decades, public opinion polls have become an ubiquitous tool for probing the complexity of people's beliefs and attitudes on a wide variety of issues. Especially since the late 1970s, the use of polls by news organizations has increased dramatically. Along with the proliferation of traditional polls, in the past few years pollsters and news organizations have come to recognize the advantages of online polls. Increasingly there has been more effort to take the pulse of the public through the Internet. With the Internet's rapid growth during the past years, advocates of online polling often emphasize the relative advantages over traditional polls. Researchers from Harris Black International Ltd., for example, argue that "Internet polling is less expensive and faster and offers higher response rates than telephone surveys." Moreover, since many of the newer online polls draw respondents from large databases of registered Internet users, results of online polls have become more balanced. A series of Harris Black online polls conducted during the 1998 gubernatorial and senatorial elections, for example, has accurately projected the winners in 21 of the 22 races it tracked. Many researchers, however, severely criticize online polls for not being representative of the larger population. Despite the often enormous number of participants, Internet users who participate in online polls tend to be younger, better educated and more affluent than the general population. As Traugott pointed out, the people polled in Internet surveys are a "self selected" group, and thus "have volunteered to be part of the test sample, which could mean they are more comfortable with technology, more informed about news and events ... than Americans who aren't online." The fact that users of online polls are self selected and demographically very different from Americans who have no access to the Internet is likely to influence the estimates of what the majority of people think about social or political issues. One of the goals of this study is therefore to analyze whether people perceive traditional and online public opinion polls differently. While most people might not differentiate sufficiently between traditional random sample polls and non representative online polls, some audiences might perceive online polls as more useful and representative. Since most online polls allow some form of direct participation, mostly in the form of an instant vote by mouse click, and often present their findings based on huge numbers of respondents, consumers of these polls might perceive them as more accurate, representative or reliable than traditional random sample polls. If that is true, perceptions of public opinion in society could be significantly distorted for those who rely on or participate in online polls. In addition to investigating how people perceive random sample and online polls, this study focuses on the perceived impact of public opinion polls. Similar to these past studies, which focused on how public opinion polls can influence the perception of mass opinion, this study will analyze how people perceive the effects of polls on themselves and other people. This interest springs from prior studies of the "third person effect," which have found that people often tend to perceive that persuasive communications exert a stronger influence on others than on themselves. While most studies concerned with the political effects of public opinion polls show that exit polls and early reporting of election returns have only weak or no effects on the outcome of election campaigns, some empirical findings suggest that exposure to polls can move people's opinions both toward and away from perceived majority opinion. Thus, if people indeed believe that polls influence others more than themselves, perceptions of majority opinion could be significantly altered because people might anticipate that others will react more strongly to poll results.

  • PDF

Pain reducing effect of vapocoolant spray during injection and heelstick procedure in neonates (신생아에서 근육 주사 및 발뒤꿈치 천자 시 냉각 분사의 통증감소효과: 냉각 분사와 30% 경구 포도당액의 비교)

  • Choi, Eun Kyong;Jung, Ji Mi;Sin, Jong Beom
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.5
    • /
    • pp.481-486
    • /
    • 2008
  • Purpose : The aims of this study were to test the efficacy of vapocoolant spray to decrease the symptoms associated with pain in newborns undergoing heel stick and intramuscular injection and compare the pain relief effect of oral glucose. Methods : Randomized, controlled study including sixty newborns undergoing heel stick and intramuscular injection. Group 1 was heelsticked, Group 2 was intramuscular injected, Group A did not recieve any treatment, Group B recieved 30% glucose solution orally, Group C was applied vapocoolant spray symptoms and signs associated with pain at heel stick and intramuscular injection were measured with the premature Infant Pain Profile (PIPP) scale. Results : There was no significant difference in the PIPP score between intramuscular injected group control and heel stick group control (P=0.07). The mean PIPP score of Group 1A (control) $10.6{\pm}2.4$, Group 1B $5.5{\pm}2.0$, Group 1C $5.2{\pm}1.8$. The mean PIPP score 1B and 1C were significantly lower than control (1B P<0.001, 1C P<0.001). The mean PIPP score of Group 2A (control) $12.5{\pm}1.4$, Group 2B $7.0{\pm}1.7$, Group 2C $6.4{\pm}1.6$. The mean PIPP score 2B and 2C were significantly lower than control (2B P<0.001, 2C P<0.001). Conclusion : The antinociceptive effect of vapocoolant sparay is as effective as 30% oral glucose solution for pain control. So this study support the use of vapocoolant spray for reducing pain during painful procedure in the neonatal intensive care units.

Application of the Pulsatile Cardiopulmonary Bypass in Animal Model (이중 박동성 인공심폐기의 동물 실험)

  • Shin, Hwa-Kyun;Won, Yong-Soon;Lee, Jea-Yook;Her, Keun;Yeum, Yook;Kim, Seung-Chul;Min, Byoung-Goo
    • Journal of Chest Surgery
    • /
    • v.37 no.1
    • /
    • pp.1-10
    • /
    • 2004
  • Background: Currently, the cardiopulmonary machine with non-pulsatile pumps, which are low in internal circuit pressure and cause little damage to blood cells, is widely used. However, a great number of experimental studies shows that pulsatile perfusions are more useful than non-pulsatile counterparts in many areas, such as homodynamic, metabolism, organ functions, and micro-circulation. Yet, many concerns relating to pulsatile cardiopulmonary machines, such as high internal circuit pressure and blood cell damage, have long hindered the development of pulsatile cardiopulmonary machines. Against this backdrop, this study focuses on the safety and effectiveness of the pulsatile cardiopulmonary machines developed by a domestic research lab. Material and Method: The dual-pulsatile cardiopulmonary bypass experiment with total extracorporeal circulation was conducted on six calves, Extracorporeal circulation was provided between superior/inferior vena cava and aorta. The membrane oxygenator, which was placed between the left and right pumps, was used for blood oxygenation. Circulation took four hours. Arterial blood gas analysis and blood tests were also conducted. Plasma hemoglobin levels were calculated, while pulse pressure and internal circuit pressure were carefully observed. Measurement was taken five times; once before the operation of the cardiopulmonary bypass, and after its operation it was taken every hour for four hours. Result: Through the arterial blood gas analysis, PCO2 and pH remained within normal levels. PO2 in arterial blood showed enough oxygenation of over 100 mmHg. The level of plasma hemoglobin, which had total cardiopulmonary circulation, steadily increased to 15.87 $\pm$ 5.63 after four hours passed, but remained below 20 mg/㎗. There was no obvious abnormal findings in blood test. Systolic blood pressure which was at 97.5$\pm$5.7 mmHg during the pre-circulation contraction period, was maintained over 100 mmHg as time passed. Moreover, diastolic blood pressure was 72.2 $\pm$ 7.7 mmHg during the expansion period and well kept at the appropriate level with time passing by. Average blood pressure which was 83$\pm$9.2 mmHg before circulation, increased as time passed, while pump flow was maintained over 3.3 L/min. Blood pressure fluctuation during total extracorporeal circulation showed a similar level of arterial blood pressure of pre-circulation heart. Conclusion: In the experiment mentioned above, pulsatile cardiopulmonary machines using the doual-pulsatile structure provided effective pulsatile blood flow with little damage in blood cells, showing excellence in the aspects of hematology and hemodynamic. Therefore, it is expected that the pulsatile cardiopulmonary machine, if it becomes a standard cardiopulmonary machine in all heart operations, will provide stable blood flow to end-organs.

Evaluation of Metabolic Abnormality in Brain Tumors by In Viuo $^1$H MR Spectroscopy at 3 Tesla (3T 양성자 자기공명분광에 의한 뇌종양의 대사물질 이상소견)

  • Choe, Bo-Young;Jeun, Sin-Soo;Kim, Bum-Soo;Lee, Jae-Mun;Chung, Sung-Taek;Ahn, Chang-Beom;Oh, Chang-Hyun;Kim, Sun I.;Lee, Hyoung-Koo
    • Progress in Medical Physics
    • /
    • v.13 no.3
    • /
    • pp.120-128
    • /
    • 2002
  • To investigate differences between the metabolic ratios of normal controls and brain tumors such as astrocytomas and glioblastoma multiforme (GM) by proton MR spectroscopy (MRS) at 37 high field system. Using 3T MRI/MRS system, localized water-suppressed single-voxel technique in patients with brain tumors was employed to evaluate spectra with peaks of N-acetyl aspartate (NAA), choline-containing compounds (Cho), creatine/phosphocreatine (Cr) and lactate. On the basis of Cr, these peak areas were quantificated as a relative ratio. The variation of metabolites measurements of the designated region in 10 normal volunteers was less than 10%. Normal ranges of NAA/Cr and Cho/Cr ratios were 1.67$\pm$018 and 1.16$\pm$0.15, respectively. NAA/Cr ratio of all tumor tissues was significantly lower than that of the normal tissues (P=0.005). Cho/Cr ratio of glioblastoma multiforme was significantly higher than that of astrocytomas (P=0.001). Lactate was observed in all tumor cases. The present study demonstrated that the neuronal degradation or loss was observed in all tumor tissues. Higher grade of brain tumors was correlated with higher Cho/Cr ratio, indicating a significant dependence of Cho levels on malignancy of gliomas. This results suggest that clinical proton MR spectroscopy could be useful to predict tumor malignancy.

  • PDF

Mechanical Properties of Granulated Ground Blast Furnace Slag on Blended Activator of Sulfate and Alkali (황산염 및 알칼리계의 혼합 활성화제에 대한 고로슬래그미분말의 역학적 특성)

  • Kim, Tae-Wan;Jun, Yu-Bin;Eom, Jang-Sub
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.5
    • /
    • pp.104-111
    • /
    • 2015
  • This study shows the mechanical properties of alkali-activated slag cement (AASC) synthesized using sulfate with NaOH solution. The used sulfates were calcium sulfate ($CaSO_4$, denoted CS) and sodium sulfate ($Na_2SO_4$, denoted SS). The replacement ratio of sulfates was 2.5, 5.0, 7.5 and 10.0% by weight of slag. NaOH solution of 2M and 4M concentration was used. A sample was activated with sulfate and activated with blended activator (blending NaOH solution with sulfate) respectively. 24 mix ratios were used and the water-binder weight ratio for the test was set 0.5. This research carried out the compressive strength, flexural strength, ultrasonic pulse velocity (UPV), absorption and X-ray diffraction (XRD). In the case of samples with CS, sample with 7.5% CS, sample with 2M NaOH+5.0% CS and sample with 4M NaOH+5.0% CS showed the good performance in the strength development. In the case of samples with SS, sample with 10.0% SS, sample with 2M NaOH+7.5% SS and sample with 4M NaOH+2.5% SS obtained good performance in strength. The results of UPV and water absorption showed a similar tendency to the strength properties. The XRD analysis of samples indicated that the hydration products formed in samples were ettringite, CSH and silicate phases. In this study, it is indicated that when compared to the use of sulfate only, the use of both sulfate and NaOH solution makes mechanical properties of AASC better.

A Study on Real-Time Defect Detection Using Ultrasound Excited Thermography (초음파 서모그라피를 이용한 실시간 결함 검출에 대한 연구)

  • Cho, Jai-Wan;Seo, Yong-Chil;Jung, Seung-Ho;Jung, Hyun-Kyu;Kim, Seung-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.4
    • /
    • pp.211-219
    • /
    • 2006
  • The UET(ultrasound excited thermography) for the ,eat-time diagnostics of the object employs an infrared camera to image defects of the surface and subsurface which are locally heated using high-frequency putted ultrasonic excitation. The dissipation of high-power ultrasonic energy around the feces of the defects causes an increase In temperature. The defect's image appears as a hot spot (bright IR source) within a dark background field. The UET for nondestructive diagnostic and evaluation is based on the image analysis of the hot spot as a local response to ultrasonic excited heat deposition. In this paper the applicability of VET for fast imaging of defect is described. The ultrasonic energy is injected into the sample through a transducer in the vertical and horizontal directions respectively. The voltage applied to the transducer is measured by digital oscilloscope, and the waveform are compared. Measurements were performed on four kinds of materials: SUS fatigue crack specimen(thickness 14mm), PCB plate(1.8 mm), CFRP plate(3 mm) and Inconel 600 plate (1 mm). A high power ultrasonic energy with pulse durations of 250ms Is injected into the samples in the horizontal and vertical directions respectively The obtained experimental result reveals that the dissipation loss of the ultrasonic energy In the vertical injection is less than that in the horizontal direction. In the cafe or PCB, CFRP, the size of hot spot in the vortical injection if larger than that in horizontal direction. Duration time of the hot spot in the vertical direction is three times as long as that in the horizontal direction. In the case of Inconel 600 plate and SUS sample, the hot spot in the horizontal injection was detected faster than that in the vertical direction

Fertigation Techniques Using Fertilizers with Peristaltic Hose Pump for Hydroponics (연동펌프를 이용한 비료염 공급 관비재배기술 연구)

  • Kim, D.E.;Lee, G.I.;Kim, H.H.;Woo, Y.H.;Lee, W.Y.;Kang, I.C.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.17 no.1
    • /
    • pp.57-71
    • /
    • 2015
  • This study was conducted to develop the fertigation system with a peristaltic hose pump and brushless DC motor. The fertigation system was consisted of sensor, main controller, motor control unit, peristaltic pump, water supply pump, control panel, and filter. The peristaltic pump discharges liquid by squeezing the tube with rollers. Rollers attached to the external circumference of the rotor compresses the flexible tube. The fluid is contained within a flexible tube fitted inside a circular pump casing. The developed fertigation system has no mixing tank but instead injects directly a concentrated nutrient solution into a water supply pipe. The revolution speed of the peristaltic pump is controlled by PWM (Pulse width modulation) method. When the revolution speed of the peristaltic pump was 300rpm, the flow rate of the 3.2, 4.8, 6.3mm diameter tube was 202, 530, 857mL/min, respectively. As increasing revolution speed, the flow rate of the peristaltic pump linearly increased. As the inner diameter of a tube larger, a slope of graph is more steep. Flow rate of three roller was more than that of four roller. Flow rate of a norprene tube with good restoring force was more than that of a pharmed tube. As EC sensor probe was installed in direct piping in comparison with bypass piping showed good performance. After starting the system, it took 16~17 seconds to stabilize EC. The maximum value of EC was 1.44~1.7dS/m at a setting value of 1.4dS/m. The developed fertigation system showed ±0.06dS/m deviation from the setting value of EC. In field test, Cucumber plants generally showed good growth. From these findings, this fertigation system can be appropriately suitable for fertigation culture for crops.