• Title/Summary/Keyword: Pulse test

Search Result 1,181, Processing Time 0.028 seconds

Development of 30-Tonf LOx/Kerosene Rocket Engine Combustion Devices(I) - Combustion Chamber (추력 30톤급 액체산소/케로신 로켓엔진 연소장치 개발(I)-연소기)

  • Choi, Hwan-Seok;Han, Young-Min;Kim, Young-Mog;Cho, Gwang-Rae
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.10
    • /
    • pp.1027-1037
    • /
    • 2009
  • The development of a combustion chamber for a 30-$ton_f$ regeneratively-cooled space liquid rocket engine is described. Starting from the development of bi-propellant swirl coaxial injectors, essential technologies were verified through subscale combustion chambers and afterwards applied to the full-scale combustion chambers. A total of 5 full-scale combustion chambers have been utilized to verify ignition, combustion efficiency and stability, cooling, and duration requirements. A total of 46 combustion tests were performed among which 23 tests were parallely performed with stability rating tests using a pulse gun device. The test results have revealed that the 30-$ton_f$ regeneratively-cooled combustion chamber fully complies to the performance and combustion stability requirements and thus concluded that the development is successfully completed.

Open Channel Block of Kv3.1 Currents by Genistein, a Tyrosine Kinase Inhibitor

  • Choi, Bok-Hee;Park, Ji-Hyun;Hahn, Sang-June
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.10 no.2
    • /
    • pp.71-77
    • /
    • 2006
  • The goal of this study was to analyze the effects of genistein, a widely used tyrosine kinase inhibitor, on cloned Shaw-type $K^+$ currents, Kv3.1 which were stably expressed in Chinese hamster ovary (CHO) cells, using the whole-cell configuration of patch-clamp techniques. In whole-cell recordings, genistein at external concentrations from 10 to $100{\mu}M$ accelerated the rate of inactivation of Kv3.1 currents, thereby concentration-dependently reducing the current at the end of depolarizing pulse with an $IC_{50}$ value of $15.71{\pm}0.67{\mu}M$ and a Hill coefficient of $3.28{\pm}0.35$ (n=5). The time constant of activation at a 300 ms depolarizing test pulses from -80 mV to +40 mV was $1.01{\pm}0.04$ ms and $0.90{\pm}0.05$ ms (n=9) under control conditions and in the presence of $20{\mu}M$ genistein, respectively, indicating that the activation kinetics was not significantly modified by genistein. Genistein $(20{\mu}M)$ slowed the deactivation of the tail current elicited upon repolarization to -40 mV, thus inducing a crossover phenomenon. These results suggest that drug unbinding is required before Kv3.1 channels can close. Genistein-induced block was voltage-dependent, increasing in the voltage range $(-20\'mV{\sim}0\'mV)$ for channel opening, suggesting an open channel interaction. Genistein $(20{\mu}M)$ produced use-dependent block of Kv3.1 at a stimulation frequency of 1 Hz. The voltage dependence of steady-state inactivation of Kv3.1 was not changed by $20{\mu}M$ genistein. Our results indicate that genistein blocks directly Kv3.1 currents in concentration-, voltage-, time-dependent manners and the action of genistein on Kv3.1 is independent of tyrosine kinase inhibition.

Analysis on the Discharge Characteristics of New Cell Structure for Luminous Efficacy Improvement in an AC Plasma Display Panel (교류형 플라즈마 표시키의 발광 효율 개설을 위한 실 구조의 방전 특성 분석)

  • Bae, Hyun-Sook;Whang, Ki-Woong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.6
    • /
    • pp.7-13
    • /
    • 2008
  • Through two-dimensional numerical simulations, we analyzed the effects of new cell structure for the luminous efficacy improvement in an ac plasma display panel. In the new structure with 5 electrodes, two auxiliary electrodes are arranged between X and Y electrodes with long gap. Through the application of adequate auxiliary pulse on the address electrode, the luminous efficacy in the new cell structure showed the improvement of 52[%] in comparison with that of conventional cell structure with short gap between X and Y electrodes. Consequently, as the short gap discharge between auxiliary electrodes decreases and the long gap discharge between X and Y electrodes increases, the result of VUV generation efficacy shows higher improvement. The reliability of simulation result could he confirmed by the experimental result in the test panel.

A Study on Development and Analysis of Control Operation Software of High-Speed Recorder (고속기록기의 제어운용 소프트웨어 분석 및 개발에 관한 연구)

  • Hwang, Chul-Jun;Oh, Se-Jin
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.10 no.4
    • /
    • pp.280-288
    • /
    • 2009
  • In this paper, we developed new time information recording module of VSI (VLBI Standard Interface) format by analyzing the Mark5B recorder control and operation software with 1Gbps speed, which is able to record the weak signal of space radio source, through the Korean VLBI Network (KVN). The control and operation software of high-speed recorder consists of 2 kinds of software, which is that it can operate RAID control board by controlling large capacity HDD drive and the network control and operation. Especially, core software in high-speed recorder is able to output the results after performing and analyzing the input command. Through the analysis of control and operation software, new time information recording module, which is needed to process the observed data for correlation, is developed. New developed time information recording module can record the time information together after checking the interrupt of 1PPS(Pulse Per Second) input signal when the observed data will be recorded. To verify the normal operation of the developed time information recording module, we performed the real observation test and confirmed the effectiveness of developed software through analyzing the recorded observation data.

  • PDF

Thermal and telemetry module design for satellite camera

  • Kong, Jong-Pil;Yong, Sang-Soon;Heo, Haeng-Pal;Kim, Young-Sun;Youn, Heong-Sik
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.229-234
    • /
    • 2002
  • Under the hostile influence of the extreme space environmental conditions due to the deep space and direct solar flux, the thermal control in space applications is especially of major importance. There are tight temperature range restrictions for electro-optical elements while on the other hand there are low power consumption requirements due to the limited energy sources on the spacecraft. So, we usually have strong requirement of thermal and power control module in space applications. In this paper, the design concept of a thermal and power control module in the MSC(Multi-Spectral Camera) system which will be a payload on KOMPSATII is described in terms of H/W & S/W. This thermal and power control module, called THTM(Thermal and Telemetry Module) in MSC, resides inside the PMU(Payload Management Unit) which is responsible for the proper management of the MSC payload for controlling and monitoring the temperature insides the EOS(Electro-Optic System) and gathering all the analog telemetry from all the MSC sub-units, etc. Particularly, the designed heater controller has the special mode of "duty cycle" in addition to normal closed loop control mode as usual. THTM controls heaters in open loop according to on/off set time designed through analysis in duty cycle mode in case of all thermistor failure whereas it controls heaters by comparing the thermistor value to temperature based on closed loop in normal mode. And a designed THTM provides a checking and protection method against the failure in thermal control command using the test pulse in command itself.

  • PDF

Effects of olfactory self- and cross-adaptation on perceiving odor in a moth

  • Qian, Kai;Chen, Haibin;Wan, Xinlong
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.32 no.2
    • /
    • pp.60-68
    • /
    • 2016
  • Pheromone orientation in moths is an exemplar of olfactory sensitivity. To avoid cross mating, the responses of males to pheromone blends must be high specificity and temporal resolution. We tested the effects of olfactory self- and cross-adaptation of pheromone compounds and mixtures in Spodoptera litura moths by electroantennogram (EAG) recordings. The challenge of S. litura antennae to a pulse train of its own pheromone blends of Z9,E11-14:OAc and Z9,E12-14:OAc with 200 ms on/off and 1 s on/off indicated that the repetitive stimulation by 200 ms on/off with high dosages resulted in greater adaptation than that by 1 s on/off with low dosages and the adaptation index of Z9,E11-14:OAc in all treatments is significantly larger than that of Z9,E12-14:OAc, suggesting that high dosages with more frequent stimulation prefer to induce sensory adaptations and a different odor coding exist between the two components in the antennal periphery in this moth. The cross-adaptation EAG test among the two pheromone compounds and Z7-12:OAc and Z9-14:OH from congeneric species of S. litura showed that each of these compounds adapted the antenna more to that specific compound. The significantly higher adaptation to Z7-12:OAc and Z9-14:OH than to the pheromone components of S. litura induced by themselves suggested that both of them are coded by specific odor receptor neurons which are different from those tuned to the pheromone components of S. litura . Thus, we proposed that Z7-12:OAc and Z9-14:OH may play an important role in avoidance of heterospecific mating between S. litura and its sympatric moth species.

A Study on Correlation among Physical Fitness, Diet Intakes and Serum Lipid in Middle Aged Women. (중년여성의 체력, 식이섭취와 혈청지질과의 상관관계에 대한 연구)

  • 안창순
    • The Korean Journal of Food And Nutrition
    • /
    • v.6 no.4
    • /
    • pp.255-267
    • /
    • 1993
  • This study was performed to investigate the correlations among physical anthropometric measurement, diet intakes, physical fitness test, and serum lipids in eight sedentary women(control group), and twenty seven exercising women(aerobic groups), aged 35~45 years. The results of the study are as follows : 1) systolic blood pressure(SBP) and diastolic blood pressure(DBP) of aerobic groups were lower than serf entary. Pulse rate was decreased according to the length of aerobic periods. Muscular endurance and jump power of all subjects were stronger than standard range, and those of aerobic exercising groups were stronger than control group. Muscular power of the upper half of the body In all subjects were lower than standard range. 2) Daily calorie intakes of all subjects were in the ring: of recommended dietary allowances (RDA) for Koreans. But daily protein Intakes were higher than RDA. daily cholestrol intakes of all subjects were slightly less than 200~300 mg: which is normal consumption of Koreans. 3) There was a significant positive correlation between serum 7G and daily protein intakes. It was considered that excessive protein intake converted to serum 7G. There was not a significant correlation between serum TC and dietary TC. Therefore, dietary TC seemed to have not much effect on serum TC. Physical fitness was negatively related to serum TG, TC, LDL-C, but positively related to HDL-C, HDL-C /TC. It was found that the serum lipids could be changed better according to improving the physical fitness. There were significant positive correlations between SBP and serum TC, LDL-C. (According to this results), the higher SBP, the higher serum TC, LDL-C tended to be. There was a significant positive correlations between sit up and weightloss nth exercise r=0.7(p<0.001), push ups and weightless with exercise r=0.5(p<0.001). It was considered that muscle strength could be improved according to the weightloss. 4) The purpose of exercise in aerobic groups was rather promoting health than reducing body fatness. Most of al1 subjects (83.2%) drank caffeine-contained beverage therefore, we should concern about that absorption of Fe could be Interrupted and blood pressure could be elevated by caffeine.

  • PDF

Detection of Indication of Electric Accident in Simulated Electric Equipments Using Standard Deviation and Probability Distribution (표준편차와 확률분포를 이용한 모의전기설비에서 사고징후 검출)

  • Jee, Seung-Wook;Ok, Kyung-Gea;Kim, Shi-Kuk;Lee, Chun-Ha
    • Fire Science and Engineering
    • /
    • v.23 no.3
    • /
    • pp.11-16
    • /
    • 2009
  • This paper describes a detecting method for indication of an electric accident in electric equipments. For that, loads of electric equipment is consisted of incandescent lamps. And the electric accident is simulated a tracking test apparatus according to KS C IEC (Korea Standard C International Electrostatic Commission) 60112 at some part of the simulation of the electric equipment. Simulated electric accident is occurred from static states through discharge in progress, carbon formation to tracking breakdown. The total current of electric equipments is measured and analyzed for detecting of indication of the electric accident using a current monitor. For the result, as an electric accident processed, as a current pulse is bigger and a ratio of appearance also increases at certain part of current waveforms. And standard deviation and probability distribution for certain part of current waveforms show remarkably different pattern in each step of electric accident which is irrespective of amount of load.

An Implement of Fixed Obstacle Detecting RADAR Algorithm for Smart Highway (스마트하이웨이에 적합한 장애물 탐지용 레이더 알고리즘 구현)

  • Lee, Jae-Kyun;Park, Jae-Hyoung
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.13 no.2
    • /
    • pp.106-112
    • /
    • 2012
  • Smart Highway is the intelligent highway that improves a traffic safety, reduces incidence of traffic accidents, and supports intelligent and convenient driving environment so that drivers can drive at high speeds in safety[1]. In order to implement the highway, it is required to gather a dangerous data such as obstacle, wild animal, disabled car, etc. To provide the situation information of the highway, it has been gathered traffic information using various sensors. However, this technique has problems such as the problems of various information gathering, lack of accuracy depending on weather conditions and limitation of maintenance. Therefore, in order to provide safe driving information to driver by gathering dangerous condition, radar system is needed. In this paper, we used a developing 34.5GHz RWR(Road Watch Radar) radar for gathering dangerous information and we verified performance of obstacle detecting and resolution through field test.

Correctum : Effects of olfactory self- and cross-adaptation on perceiving odor in a moth

  • Qian, Kai;Chen, Haibin;Wan, Xinlong
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.33 no.2
    • /
    • pp.149-149
    • /
    • 2016
  • Pheromone orientation in moths is an exemplar of olfactory sensitivity. To avoid cross mating, the responses of males to pheromone blends must be high specificity and temporal resolution. We tested the effects of olfactory self-and cross-adaptation of pheromone compounds and mixtures in Spodoptera litura moths by electroantennogram (EAG) recordings. The challenge of S. litura antennae to a pulse train of its own pheromone blends of Z9,E11-14:OAc and Z9,E12-14:OAc with 200 ms on/off and 1 s on/off indicated that the repetitive stimulation by 200 ms on/off with high dosages resulted in greater adaptation than that by 1 s on/off with low dosages and the adaptation index of Z9,E11-14:OAc in all treatments is significantly larger than that of Z9,E12-14:OAc, suggesting that high dosages with more frequent stimulation prefer to induce sensory adaptations and a different odor coding exist between the two components in the antennal periphery in this moth. The cross-adaptation EAG test among the two pheromone compounds and Z7-12:OAc and Z9-14:OH from congeneric species of S. litura showed that each of these compounds adapted the antenna more to that specific compound. The significantly higher adaptation to Z7-12:OAc and Z9-14:OH than to the pheromone components of S. litura induced by themselves suggested that both of them are coded by specific odor receptor neurons which are different from those tuned to the pheromone components of S. litura. Thus, we proposed that Z7-12:OAc and Z9-14:OH may play an important role in avoidance of heterospecific mating between S. litura and its sympatric moth species.