• Title/Summary/Keyword: Pulse system

Search Result 3,050, Processing Time 0.032 seconds

Improvement of pulse characteristics of glass laser oscillator (글라스 레이저 발진기의 출력펄스특성의 개선에 관한 연구)

  • 강형부
    • 전기의세계
    • /
    • v.29 no.5
    • /
    • pp.321-328
    • /
    • 1980
  • The Q-switching oscillator of TE $M_{00}$ mode was constructed in order to improve the properties of energy focusing and amplification, and prevent laser materials from breakdown. The Q-switching was done by means of electro-optical effect using Glan prism and KDP Pockels cell. Sharp laser pulse of risetime-1 ns and variable pulse width 2-10 ns was obtained from Q-switching laser pulse by PTM method using a laser triggered spark gap (LTSG), Glan prism and Pockels cell. A single ultra-short pulse (picosec order in pulse width) was obtained from mode-locked pulse train in combination of a mode-locked oscillator using saturable dye cell with pulse shaping system using PTM method.d.

  • PDF

The effect of H2O, NH3 and applied voltage to the particle conversion in the desulfurization system using a nano-pulse plasma (나노펄스 플라즈마를 이용한 탈황 시스템의 H2O 및 NH3, 펄스 인가전압에 따른 입자변환 분석)

  • Kim, Younghun;Shin, Dongho;Lee, Gunhee;Hong, Keejung;Kim, Hak-Joon;Kim, Yong-Jin;Han, Bangwoo;Hwang, Jungho
    • Particle and aerosol research
    • /
    • v.16 no.1
    • /
    • pp.1-8
    • /
    • 2020
  • Nano-pulse plasma technology has great potential as the process simplicity, high efficiency and low energy consumption for SO2 removal. The research on the gas-to-particle conversion is required to achieve higher efficiency of SO2 gas removal. Thus, we studied the effect of the relative humidity, NH3 concentration and applied voltage of the nano-pulse plasma system in the gas to particle conversion of SO2. The particles from the conversions were increased from 10 to 100 nm in diameter as relative humidity, NH3 concentration, applied voltage increases. With these results, nano-pulse plasma system can be used to more efficient removal of SO2 gas by controlling above parameters.

Performance of M-ary PPM UWB Radio in Fading Channels

  • Mohammed, Abdel-Hafez;Alagoz, Fatih;Hamalainen, Matti
    • Journal of Communications and Networks
    • /
    • v.5 no.4
    • /
    • pp.365-373
    • /
    • 2003
  • This paper investigates the performance of M-ary pulse position modulation (PPM) multiuser ultra-wideband (UWB) communication systems in terms of symbol error rate (SER) over fading and additive white Gaussian noise (AWGN) channel. Based on Gaussian approximation for the multiple access interference, an expression for the signal-to-noise ratio (SNR) is derived for the UWB system. This expression is used to derive exact SER expressions for coherent UWB receivers. The effect of pulse selection on the SER of multiuser UWB system is studied. In addition to rectangular pulse, the 2nd derivative Gaussian waveform and Rayleigh pulses were considered. We show that the system capacity and/or SER performance can be significantly increased by using the monocycle pulse in fading channels.

Playback Signal Processing in a Digital High Density Magnetic Recording System (디지털 고밀도 자기기록 장치의 재생신호 처리에 관한 연구)

  • 이상록;박시우;박선기;박진우
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.30B no.12
    • /
    • pp.31-39
    • /
    • 1993
  • In the playback signal processing of a digital magnetic recording system, the major signal processing processes consist of pulse equalization. pulse detection, clock recovery, and data recovery. Equalizer which compensates interference occurrde between pulses recorded in high density on a magnetic media is realized by pulse slimming method, and pulse detection by a integrating detector. Clock recovery from the detector output was accomplished by using PLL. and data recovery to reduce noise effects was carried out by utilizing the three sampling clocks recovered in clock recovery process. In this paper these processes are implemented in hardware and its performance is evaluated by experimenting with a commercial DAT. It was found that the playback signal processor proposed is suitable to the practical high density magnetic recording system.

  • PDF

Development of Software Interpolator for Two-Axis Contouring Control (2축 윤곽제어를 위한 소프트웨어 보간자 개발에 관한 연구)

  • 김교형;이기설
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.2
    • /
    • pp.389-396
    • /
    • 1988
  • Microprocessor-based software DDA interpolator is developed and applied to two axis contouring control of X-Y table. Developed assembly program is composed of feedrate, linear and circular DDA interpolation routines. Reference-pulse type of open-loop stepping motor control system in which the micro-computer produces a sequence of reference pulses for each axis of motion is adopted. To test performance of the developed program, X-Y table drive system based on stepping motor and shaft encoder is designed. Conturing error of the system in linear and circular path is within .+-. 0.2mm under start stop pulse rate of stepping motor.

Development of 3-channel Pulse Wave Measurement System (3채널 맥파 측정 시스템 개발)

  • Kim, Eun-Geun;Heo, Hyun;Nam, Ki-Chang;Kang, Hee-Jung;Huh, Young
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1049-1050
    • /
    • 2008
  • It is difficult to measure the pulse wave in a short time because radial artery position and located depth are different depending on the person. In this paper, the pulse wave measurement system was developed using 3 channel piezoresistive sensor array to detect the most significant pulse wave. Augmentation Index(AI) and Heart Rate(HR) analysis are also available for predicting cardiovascular risks. The developed system is small and easy to use. And it is promising to be used as home healthcare device.

  • PDF

Marx Generator Implementation Using IGBT Stack (IGBT 스택을 이용한 Marx Generator 구현)

  • Kim, J.H.;Min, B.D.;Kim, J.S.;Rim, G.H.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.507-510
    • /
    • 2005
  • High voltage pulse power supply using Marx generator and solid-state switches is proposed in this study. The Marx generator is composed of 12 stages and each stage is made of IGBT stack, two diode stacks, and capacitor. To charge the capacitors of each stage in parallel, inductive charging method is used and this method results in high efficiency and high repetition rates. It can generate the pulse voltage with the following parameters: Voltage: up to 120kv Rising time: sub ${\mu}S$ Pulse width: up to $10{\mu}S$, Pulse repetition rate: 1000pps The proposed pulsed power generator uses IGBT stack with a simple driver and has modular design. So this system structure gives compactness and easiness to implement total system. Some experimental results are included to verify the system performances in this paper.

  • PDF

6펄스 콘버어터로 제어되는 초전도 에너지 저장장치에 의한 전력계통 안정화

  • 차귀수;한송엽;원종수
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.35 no.8
    • /
    • pp.353-362
    • /
    • 1986
  • This paper shows that 6 pulse converter instead of 12 pulse converter can be used for the control of Superconducting Magnet Energy Storage(SMES) to improve the stability and to suppress the voltage fluctuation of power system. In order to prevent the commutation failure, when 6 pulse converter used for simultaneous control of real power and reactive power is asymmetrically controlled, stable control region has been presented by analyzing the commutation phenomena at critical points which distinguish the stable control region from the unstrol control region. Harmonic components of line current and output voltage have been calculated. Finally, computer simulation of power system stabilization has been presented to show the effectiveness of the proposed method. According to the computation results, SMES controlled by the 6 pulse converter is an effective measure in reducing the oscillation and the transient instability of the power system.

  • PDF

A Study on the Web-based Remote Pulse Diagnosis System (Web 기반 원격 맥진 시스템 구축에 관한 연구)

  • Lee, J.Y.;Lee, S.J.;Kim, J.H.;Lee, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2821-2822
    • /
    • 2001
  • This study has conducted researches in the web-based diagnosis data management system of pulse waveform as well as the method of transmitting the data of pulse waveform. In order to set the standard for the documents of the pulse waveform of patients, the web-based clinical database management system has been developed.

  • PDF

A Study on the PD Pulse Analysis and Noise Discrimination Method according to various sensors (센서에 따른 부분방전 펄스 분석 및 노이즈 제거 기법에 대한 연구)

  • Kim, Jeong-Tae;Rhee, Wook
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1469-1471
    • /
    • 2006
  • It is very important to discriminate noises such as air corona in measuring on-site partial discharges (PD). Therefore, in order to investigate the possibility of separating PD(partial discharge) and noises through the pulse analysis, pulse shapes measured by a resistive sensor and a HFCT were analyzed and PA(pulse analysis) were performed. For the purpose, the HFPD detection and PA system has been developed. Also void discharges and air corona were adopted as the artificial defect and noises, respectively.

  • PDF