• 제목/요약/키워드: Pulse shape

검색결과 436건 처리시간 0.024초

고혈압 환자에서 혈압 조절 여부에 따른 신상(脤象) 및 삶의 질 비교 (A Comparison of Controlled and Uncontrolled Hypertension Groups Regarding Pulse Shape and Quality of Life)

  • 최인영;한창호;최동준;정승현;신길조;이원철
    • 대한한방내과학회지
    • /
    • 제30권4호
    • /
    • pp.880-892
    • /
    • 2009
  • Objectives : This study is about a comparison of controlled and uncontrolled hypertension groups regarding pulse shape and quality of life. We aimed to find out if pulse shape would be able to help with hypertension treatment and care. Methods : We surveyed "controlled and uncontrolled hypertension patients" using SF-36, HTN QoL (measurement scale for the quality of life in hypertensive patients) and 3-D MAC pulse analyzer for pulse shape. Results : The uncontrolled hypertension group tended to have a sink pulse in the left cun. right guan & chi parts compared to the controlled hypertension group. Within the controlled hypertension group, patients who had a float pulse shape in both guan parts had a higher quality of life than patients who had a normal pulse shape. And the patients who had a normal pulse shape in both chi parts had a higher quality of life than patients with a slow or fast pulse shape. Within the uncontrolled hypertension grouP. the patients who had a normal pulse shape in right guan part had a higher quality of life than those with a choppy pulse shape. Nevertheless, these results were limited to only a few quality of life issues and were inconsistent in relation to specific pulse shapes. Conclusion : If we have more samples and better methods for collecting data, we will have better results, allowing us to improve our ability to predict and treat hypertension.

  • PDF

Study on the Selection of Representative Pulse Wave

  • Kim, Jong-Yeol;Shin, Sang-Hoon
    • 대한한의학회지
    • /
    • 제29권5호
    • /
    • pp.104-110
    • /
    • 2008
  • Objectives : The purpose of this study is to develop the method of selecting representative pulse wave. Methods : The pulse waves were acquired at the right and the left Guan point(關部) with 1420 people who were apparently healthy. The shape agreement of right and left pulse wave and the floating-sinking ratio were compared with three cases, which were the pulse height based method, the pulse area based method, and the pulse time based method. Results : In the point of the shape accordance, the pulse time based method was the best, and the pulse area based method was the worst. In the point of the floating-sinking ratio, the pulse height based method was the worst, and the pulse time based method was the best. Conclusions : So, the pulse time based method was recommended for selecting the representative pulse wave. This study compared the selection methods of representative pulse using the physiological characteristics of pulse wave. Further studies are required, because the representative pulse wave is the main factor of determining the shape and the floating-sinking characteristic of the pulse wave.

  • PDF

3 Stage 2 Switch Application for Transcranial Magnetic Stimulation

  • Ha, Dong-Ho;Kim, Whi-Young;Choi, Sun-Seob
    • Journal of Magnetics
    • /
    • 제16권3호
    • /
    • pp.234-239
    • /
    • 2011
  • Transcranial magnetic stimulation utilizes the method of controlling applied time and changing pulse by output pulse through power density control for diagnosis purposes. Transcranial magnetic stimulation can also be used in cases where diagnosis and treatment are difficult since output pulse shape can be changed. As intensity, pulse range, and pulse shape of the stimulation pulse must be changed according to lesion, the existing sine wave-shaped stimulation treatment pulse poses limitations in achieving various treatments and diagnosis. This study actualized a new method of transcranial magnetic stimulation that applies a 3 Stage 2 Switch( power semiconductor 2EA) for controlling pulse repetition rate by achieving numerous switching control of stimulation coil. Intensity, pulse range, and pulse shape of output can be freely changed to transform various treatment pulses in order to overcome limitations in stimulation treatment presented by the previous sine wave pulse shape. The method of freely changing pulse range by using 3 Stage 2 Switch discharge method is proposed. Pulse shape, composed of various pulse ranges, was created by grafting PFN (Pulsed Forming Network) through AVR AT80S8535 one-chip microprocessor technology, and application in transcranial magnetic stimulation was achieved to study the output characteristics of stimulation treatment pulse according to delaying time of the trigger signal applied in section switch.

Frequency-Modulated Pulse-Amplification Method for Reducing Pulse Shape Distortion

  • Jeong, Jihoon;Cho, Seryeyohan;Hwang, Seungjin;Yu, Tae Jun
    • Journal of the Korean Physical Society
    • /
    • 제73권11호
    • /
    • pp.1637-1643
    • /
    • 2018
  • To reduce the laser pulse shape distortion accompanying the amplification process and achieve an intended output pulse shape in the Nd:YAG amplifier chain, we propose a frequency-modulated pulse-amplification method. Assuming carrier-frequency-modulated seed pulses, we numerically simulate the pulse amplification in an Nd:YAG amplifier chain where severe distortion occurs. For the calculation, we develop a modified Frantz-Nodvik equation, which enables two inputs with different carrier frequencies. The simulation results indicate that the temporal contrast of the seed pulse needed to obtain a flat output pulse shape is reduced by 16 - 25 dB when frequency modulation is applied.

Voltage dependent pulse shape analysis of Geiger-Müller counter

  • Almutairi, B.;Akyurek, T.;Usman, S.
    • Nuclear Engineering and Technology
    • /
    • 제51권4호
    • /
    • pp.1081-1090
    • /
    • 2019
  • Detailed pulse shape analysis of a Geiger-$M{\ddot{u}}ller$ counter is performed to understand the pulse shape dependence on operating voltage. New data is presented to demonstrate that not all pulses generated in a GM counter are identical. In fact, there is a strong correlation between the operating voltage and the pulse shape. Similar to detector deadtime, pulse shapes fall in three distinct regions. For low voltage region, where deadtime was reported to reduce with increasing voltage, pulse generated in this region was observed to have a fixed pulse width with a variable tail. The pulse width and fall time of the tail was observed to be a function of applied voltage; exponentially reducing with increasing voltage with an exponent of negative 6E-04 and 2E-03 respectively. The second region showed a pulse without any significant tail. During this time the detector deadtime was earlier reported to be at its minimum. The highest voltage region demonstrated a different deadtime mechanism where the second pulse was reduced in width. During this time the deadtime seemed to be increasing with increasing voltage. This data allows us to gain some unique insight into the phenomenon of GM detector deadtime not reported thus far.

"상한론(傷寒論)-변맥법(辨脈法)"에 관한 연구(1) (Study on ShangHanLun BianMaiFa (1))

  • 조은경;최종문;김윤주;홍진우;신상우
    • 동의생리병리학회지
    • /
    • 제25권6호
    • /
    • pp.945-960
    • /
    • 2011
  • The BianMaiFa chapter, which is the first chapter of SongBon ShangHanLun, is the scholarly description(專論) of the pulse and pathological mechanism but has not been studied and published yet. This study is about article 1-10 which is the first part of The BianMaiFa chapter. We compared the original texts within the editions, comparing and analyzing the annotations of successive dynastic medical group. The articles of The SongBon ShangHanLun BianMaiFa chapter 1-10 is consisted as is shown: article 1 discriminates pulse by yin-yang and states about the prognosis of disease according to pulse, article 2 states about binding in yin and binding in yang which is from abnormal exuberance of yin and yang, article 3 states about the pulse and pathological mechanism of chills with fever, article 4 states about pathological mechanism and symptom of nutrient and defense through pulse, article 5 distinguishes within binding in yang(陽結), binding in yin(陰結), yang faintness(陽微), yang debilitation(陽衰), blood collapse(亡血) by the pulse which was in article 2 3 4, article 6 7 8 9 10 states states about the shape or pathological mechanism of bound pulse(結脈) skipping pulse(促脈) stirred pulse(動脈) moderate pulse(緩脈) string-like pulse(弦脈) tight pulse(緊脈) drumskin pulse(革脈). Article 4 could be understood that inch pulse is floating and deficient shape and cubit pulse is sunken and weak shape(寸脈浮虛, 尺脈沈弱) related to article 3, article 5 could be understood as binding in yin and yang is aggregation shape related to article 2, yang-qi faintness is floating and debilitation shape, yang-qi debilitation is sunken and faint shape, blood collapse is deficient and stasis shape related to article 3 4.

피부의 색소치료를 위한 펄스 광 시스템의 개발 (Development of a Pulse Light System for Treating Skin Pigmentation)

  • 전종백;탁한호
    • 한국정보통신학회논문지
    • /
    • 제25권1호
    • /
    • pp.81-87
    • /
    • 2021
  • 본 연구에서는 다양하게 피부치료가 가능한 V-IPL 방식을 도입하여 피부치료 시스템을 설계하여 실험하였고, 또한 병변에 따라 플래쉬 램프를 순차적으로 점등시키는 새로운 방식인 방전 방식을 이용하였으며, 기존의 LC 가변방식과 스위칭소자의 스위칭모드 제어방식을 활용하여 펄스 형상제어를 시스템에 구성하였다. 그 결과 마이크로프로세서를 이용하여 펄스폭이 1[㎛]까지 가변이 가능하였고, 깊이와 넓이에 따른 병변에 플래쉬 램프를 순차 점등시키므로써 펄스형상 및 펄스모양을 보다 다양하게 할 수 있었다. 그리고 펄스폭을 약 1~100[ms]까지 다양하게 긴 펄스를 만들 수 있었으며, 기존의 제품은 One pulse(pulse width : 1~40ms)이지만 제안한 제품은 Three pulse(pulse width : 1~100ms)로 특별한 차이가 있었다.

SHAPE 알고리즘을 이용한 사인파 주파수 변조 펄스의 상호간섭 억제 (Mutual interference suppression of the sinusoidal frequency modulated pulse using SHAPE algorithm)

  • 김근환;이동화
    • 한국산업정보학회논문지
    • /
    • 제27권5호
    • /
    • pp.49-59
    • /
    • 2022
  • SHAPE 알고리즘은 펄스의 스펙트럼 형태를 원하는 대로 성형하면서, 이 외의 특성에는 왜곡을 발생시키지 않도록 설계할 수 있다는 장점이 있어 기존의 능동소나 펄스 설계에 활용되었다. 본 논문에서는 다중상태 소나 시스템을 위한 펄스를 설계할 때, 주파수 대역에서 인접한 펄스 간의 상호상관도를 감소시키면서도 펄스 자체의 성능 저하를 방지하기 위해 SHAPE 알고리즘을 적용한 펄스 신호 설계 기법을 제안한다. 이를 위해서 SHAPE 알고리즘의 경계함수를 펄스 대역폭으로 제한하도록 설정하였다. 제안하는 설계 기법을 사인화 주파수 변조 펄스 신호에 적용한 결과 상호상관도를 의미하는 peak cross-correlation level (PCCL)이 44.23 dB 감소하였다. PCCL이 수십 dB 감소하였음에도 모호성 함수의 변화가 크게 관찰되지 않았으며, 부엽의 평균값을 의미하는 integrated sidelobe level (ISL)이 11.64 dB 증가하였다.

Computer-Aided Crafting of Pulse Shapes for Broadband Heteronuclear Decoupling in the presence of Homonuclear Coupling

  • Lee, Chang-Jae
    • 한국자기공명학회논문지
    • /
    • 제3권1호
    • /
    • pp.36-43
    • /
    • 1999
  • We present a pulse shape tailored for broadband decoupling for a system of spin-1/2's with scalar couplings as well. In crafting the pulse shape Coherent Averaging Theory and Fourier expansion method are used. The Fourier expansion coefficients are optimized numerically by applying the Simulated Annealing Method. The decoupling performance of the shaped pulse thus designed is then compared with the well-known composite pulse sequence, DIPSI-2. It is shown that the shaped pulse performs well even at the conditions where the DIPSI sequence begins to fail.

  • PDF

맥파의 특징점 인식과 파형의 분류에 관한 연구 (The Study on the Feature Point Recognition and Classification of Radial Pulse)

  • 길세기;김낙환;이상민;박승환;홍승홍
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 하계종합학술대회 논문집
    • /
    • pp.555-558
    • /
    • 1999
  • In this paper, Ire present the result of feature points recognition and classification of radial pulse by the shape of pulse wave. The recognition algorithm use the method which runs in parallel with both the data of ECG and differential pulse simultaneously to recognize the feature points. Also we specified 3-time elements of pulse wave as main parameters for diagnosis and measured them by execution of algorithm. then we classify the shape of radial pulse by existence and position of feature points.

  • PDF