• Title/Summary/Keyword: Pulse plasma

Search Result 499, Processing Time 0.026 seconds

Electron Microscopic Observations of Protoplast and Fusion Cell of Viola Species (Viola속 식물의 원형질체 및 융합세포의 전자현미경 관찰)

  • Chung, Yong-Mo;Im, Hyun-Hee;Son, Beung-Gu;Suh, Jung-Hae;Chung, Chung-Han;Kwon, Oh-Chang
    • Journal of Life Science
    • /
    • v.7 no.4
    • /
    • pp.282-288
    • /
    • 1997
  • To obtain a basic information on the development of Genus Viola, ultrastructure and electrofusion process between the two protoplasts from wild Viola callus cells and pansy mesophyll cells were observed with a scanning electron microscopy(SEM) and transmission electron microscopy(TEM). In the ultrastructural observation of wild viola callus protoplasts and pansy mesophyll protoplasts using SEM, their cell walls were removed completely. A knob-like formation was observed on the enlarge surface of viola callus protoplasts. On the surface of pansy mesophyll protoplasts net-like chloroplasts were observed. In SEM observation of pansy mesophyll protoplasts, chloroplasts devoid of membrane were observed on the surface the protoplasts. Pearl chain was formed by applying AC field of 200 V/cm at 1.0 MHz for 43 sec. The lysis of plasma membranes and fusion process occurred by applying a 1,600 V/cm DC pulse twice for 1 sec. After 1-2 hours of a DC pulse application, it was observed that the two protoplasts were fused completely into one cell. In TEM observation of the fused cell, many small vacuoles were located in the fusion area of the two protoplasts. Indeed, two distinct regions were observed during fusing process; in one region, a nucleus was found, while in the other region, both nucleus and nucleous were found.

  • PDF

A New Driving Method Generating Self-Erasing Discharge to Improve Luminous Efficiency in AC PDP (AC PDP에서 휘도효율을 향상시키기 위하여 자기소거 방전을 발생시키는 새로운 구동방법)

  • Cho, Byung-Gwon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.2
    • /
    • pp.168-172
    • /
    • 2014
  • A new sustain driving method is proposed to improve luminous efficiency by the generation of the self-erasing discharge during a sustain period in AC plasma display panel. As one subfield time in the conventional AC PDP is divided into the reset, address, and sustain period. Among them, as the square sustain waveform is alternately applied to the X and Y electrodes on the front plate during the sustain period, the plasma discharge for displaying the image is continuously produced. Meanwhile, in the conventional driving method, the address waveform applied to the A electrode on the rear plate is only driving during an address period and grounded during a sustain period. In this experiment, the negative pulse is applied to the A electrode at the latter part of the sustain pulse for improving the luminous efficiency producing the self-erasing discharge during the sustain period. The negative pulse on the A electrode can change from the space to the wall charge and induce the additional discharge by the accumulated wall charge when the voltages of three electrodes are grounded. As a result, the luminous efficiency will be measured with changes in the voltage level of the A electrode and the new driving method can be improved to the luminous efficiency about 32 % compared with the conventional driving method.

A Study on the Characteristics of Space Charge for the Plasma Display (플라즈마 디스플레이의 공간전하 특성에 관한 연구)

  • 염정덕
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.6
    • /
    • pp.1-7
    • /
    • 2001
  • To analyze the driving principle of PDP, the influence on the discharge characteristics of space charge was researched. Space charge generated by the priming discharge shortens delay time of the discharge which happens as follows and shorts response time. Such influences are valid up to about 30㎲ after generating priming discharge. This space charge decreases dicharge ignition voltage of the cell near priming cell and the influences are most greatly alerted on the discharge of cell which is adjacent most. And the dependency to spare charge strengthens because discharge ignition voltage drop grows by narrowing of discharge pulse width. But the influence on space charge was observed very slightly in pulse width 1㎲ or more. Therefore, to cause a steady discharge, pulse width should become 1㎲ or more at least without being influenced for space charge of the adjoining discharge.

  • PDF

The Correlation of Serum Osteoprotegerin with Non-Traditional Cardiovascular Risk Factors and Arterial Stiffness in Patients with Pre-Dialysis Chronic Kidney Disease: Results from the KNOW-CKD Study

  • Chae, Seung Yun;Chung, WooKyung;Kim, Yeong Hoon;Oh, Yun Kyu;Lee, Joongyub;Choi, Kyu Hun;Ahn, Curie;Kim, Yong-Soo
    • Journal of Korean Medical Science
    • /
    • v.33 no.53
    • /
    • pp.322.1-322.14
    • /
    • 2018
  • Background: Osteoprotegerin (OPG) plays protective roles against the development of vascular calcification (VC) which greatly contributes to the increased cardiovascular events in patients with chronic kidney disease (CKD). The present study aimed to find the non-traditional, kidney-related cardiovascular risk factors correlated to serum OPG and the effect of serum OPG on the arterial stiffness measured by brachial ankle pulse wave velocity (baPWV) in patients with the pre-dialysis CKD. Methods: We cross-sectionally analyzed the data from the patients in whom baPWV and the serum OPG were measured at the time of enrollment in a prospective pre-dialysis CKD cohort study in Korea. Results: Along with traditional cardiovascular risk factors such as age, diabetes mellitus, pulse pressure, and baPWV, non-traditional, kidney-related factors such as albuminuria, plasma level of hemoglobin, total $CO_2$ content, alkaline phosphatase, and corrected calcium were independent variables for serum OPG in multivariate linear regression. Reciprocally, the serum OPG was positively associated with baPWV in multivariate linear regression. The baPWV in the 3rd and 4th quartile groups of serum OPG were higher than that in the 1st quartile group after adjustments by age, sex and other significant factors for baPWV in linear mixed model. Conclusion: Non-traditional, kidney-related cardiovascular risk factors in addition to traditional cardiovascular risk factors were related to serum level of OPG in CKD. Serum OPG level was significantly related to baPWV. Our study suggests that kidney-related factors involved in CKD-specific pathways for VC play a role in the increased secretion of OPG into circulation in patients with CKD.

Effects of one-to-one Labor Support on Labor Pain, Labor Stress Response, Childbirth Experience and Neonatal Status for Primipara (일대일 분만지지간호가 초산모의 분만동통, 분만스트레스 반응, 분만경험 및 신생아 상태에 미치는 효과)

  • Hur, Myung-Haeng
    • Women's Health Nursing
    • /
    • v.7 no.2
    • /
    • pp.188-202
    • /
    • 2001
  • This study was designed to investigate the effect of one-to-one labor support on labor pain, labor stress response, childbirth experience and neonatal status for primipara by a quasi experiment (nonequivalent control group pretest-posttest design), from April 30, 1999 to February 20, 2000. The subjects of this experiment consisted of eighty two primipara with single gestation, full term, uncomplicated pregnancies. Forty one were in the experimental group and forty one in the control group. Their mean age was 25.95 years, their mean gestation period was 39.9 weeks. A caring package of one-to-one labor support had three components. Physical support consisted of massage, back pressure, touch. Emotional support was provided by a continuous nurse's presence, acceptance and encouragement. Informational support involved teaching breathing skills, relaxation skills and knowledge about the labor process. Data assessed labor pain, pulse rate and blood pressure to measure labor stress response. Also, in measuring the value of labor stress response, plasma epinephrine, plasma norepinephrine and serum cortisol were measured. In the 24 hours after birth, the data for the postpartum mother's childbirth experiences was collected. Umbilical cord arterial blood pH, one minute and five minute Apgar score were measured after birth. Data was analyzed by t-test, $x^2$-test, repeated measures ANOVA, ANCOVA with SAS Program. The results were as follows; 1. Labor pain was significantly low in the experimental group(P=.016). 2. No significant group effects were found, but significant time effects were found for plasma epinephrine, norepinephrine, serum cortisol, pulse rate and blood pressure. 3. The childbirth experience of the experimental group was significantly more positive than the control group (P = .005). 4. The umbilical cord arterial blood pH of the experimental group was significantly higher than the control group(P=.014). There was no significant difference between the two groups in neonatal one minute and five minute Apgar scores. In conclusion, these findings indicate that one-to-one labor support could be effective in decreasing labor pain, and increasing positive childbirth experiences, also increasing the neonatal umbilical cord arterial blood pH for primipara. So, one-to-one labor support could be applied as an effective nursing treatment for primipara.

  • PDF

Low Cost and High Sensitivity Flexible Pressure Sensor Based on Graphite Paste through Lamination after O2 Plasma Surface Treatment Process (O2 플라즈마 표면 처리 공정 후 라미네이션 공정으로 제작된 흑연 페이스트 기반의 저비용 및 고감도 유연 압력 센서)

  • Nam, Hyun Jin;Kang, Cheol;Lee, Seung-Woo;Kim, Sun Woo;Park, Se-Hoon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.29 no.4
    • /
    • pp.21-27
    • /
    • 2022
  • Flexible pressure sensor was developed using low-cost conductive graphite as printed electronics. Flexible pressure sensors are attracting attention as materials to be used in future industries such as medical, games, and AI. As a result of evaluating various electromechanical properties of the printed electrode for flexible pressure sensors, it showed a constant resistance change rate in a maximum tensile rate of 20%, 30° tension/bending, and a simple pulse test. A more appropriate matrix pattern was designed by simulating the electrodes for which this verification was completed. Utilizing the Serpentine pattern, we utilized a process that allows simultaneous fabrication and encapsulation of the matrix pattern. One side of the printed graphite electrode was O2 plasma surface treated to increase adhesive strength, rotated 90 times, and two electrodes were made into one through a lamination process. As a result of pasting the matrix pattern prepared in this way to the wrist pulse position of the human body and proceeding with the actual measurement, a constant rate of resistance change was shown regardless of gender.

Energy-controlled Micro Electrical Discharge Machining for an Al2O3-carbon Nanotube Composite

  • Ha, Chang-seung;Son, Eui-Jeong;Cha, Ju-Hong;Kang, Myung Chang;Lee, Ho-Jun
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.6
    • /
    • pp.2256-2261
    • /
    • 2017
  • Carbon nanotube (CNT) and alumina ($Al_2O_3$) are synthesized into hybrid composites, and an advanced electrical discharge machining (EDM) system is developed for the machining of hard and conductive materials. CNT nanoparticles are mixed with $Al_2O_3$ powder and the $Al_2O_3$/CNT slurry is sintered by spark plasma. The hardness and the electrical conductivity of the $Al_2O_3$/CNT hybrid composite were investigated. The electrical discharge is controlled by a capacitive ballast circuit. The capacitive ballast circuit is applied to the tungsten carbide and the $Al_2O_3$/CNT hybrid composite. The voltage-current waveforms and scanning electron microscope (SEM) images were measured to analyze the characteristics of the boring process. The developed EDM process can manufacture the ceramic based hybrid composites, thereby expecting the variety of applications.

Reactive power compensator and harmonic filter systems design for KSTAR electric power systems stabilization (KSTAR 전력계통 안정화를 위한 무효전력보상 및 고조파 필터 시스템 설계)

  • Hong, Seong-Lok;Kong, Jong-Dae;Hwang, In-Sung;Eom, Dae-Young;Kim, Yaung-Soo;Park, Byung-Ju;Yoo, Hang-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.101_102
    • /
    • 2009
  • KSTAR(Korea Superconducting Tokamak Advanced Reseach)장치는 차세대핵융합연구장치로써 30개의 초전도자석으로 구성된다. 이 초전도자석에 전원을 공급하게 되는 PF (Poloidal Field) MPS(Magnet Power Supply)는 12상 Pulse 운전을 하게 되는데 이때 $h=kp{\pm}1$의 특성고조파와 90%에 가까운 무효전력이 발생되어 KSTAR 전력계통과 인근 부하장치에 치명적인 영향을 줄 수 있어 고조파와 무효전력을 동시에 보상할 수 있는 최적의 무효전력보상장치의 도입은 필연적이다. 본 논문에서는 KSTAR 1st Plasma 실험시의 무효전력과 고조파를 저감하기 위해 설치했던 즉, 1단계 기계식 스위칭에 의한 RPC(Reactive power compensator)의 보상특성의 평가결과를 기반으로 KSTAR 2009년 Plasma 실험에 대비하여 이의 운전특성과 설치 공간에 따르는 제약 등을 고려하여 최적의 RPC 설계를 도출하기 위해 실시한 TSC(Thyristor Switch Capacitor)기반의 RPC[1] 모의해석 결과와 기술적 사항을 소개하고자 한다.

  • PDF

NO Oxidation using Non-Thermal Plasma and NOx removal by NaOH-Water Solution Shower (비열플라즈마에 의한 NO의 산화와 NaOH 샤워해 의한 NOx의 제거특성)

  • Park, Jae-Yoon;Koh, Yong-Sul;Kim, Ick-Kewn;Park, Sang-Hyun;Koh, Hee-Seok;Lee, Duck-Chool
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.947-949
    • /
    • 1998
  • In this paper, the NO was oxidized $NO_2$ by using the non-thermal plasma and NOx removal characteristics were measured by showering NaOH water-solution to $NO_2$. The NO oxidation increased in the order of DC, AC, and Pulse. NOx oxidation for two stage with applied voltage was better than that for one stage with applied voltage. NO oxidation didn't depend on applied voltage. While NO oxidation was going on, NOx removal efficiency was 20-25%, however, significantly depended on the injection method of air and $H_2O$ + air. When NaOH water-solution density of 20% was showered to flue gases, NOx removal efficiency increased to 64%.

  • PDF

Synthesis of graphene nano-sheet without catalysts and substrates using fullerene and spark plasma sintering process

  • Jun, Tae-Sung;Park, No-Hyung;So, Dea-Sup;Lee, Joon-Woo;Lim, Hak-Sang;Ham, Heon;Shim, Kwang Bo
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.23 no.1
    • /
    • pp.27-30
    • /
    • 2013
  • Catalyst-free graphene nano-sheets without substrates have been synthesized using fullerene and a high direct current (dc) pulse in the spark plasma sintering (SPS) process. Graphene nano-sheets were synthesized directly in the gas phase of carbon atoms which are generated from fullerene at a temperature of $600^{\circ}C$. Characterization has been carried out by scanning electron microscopy (SEM), high-resolution transmission electron microscopy (HR-TEM), Raman spectroscopy (Raman), X-ray photoelectron spectroscopy (XPS) and X-ray diffraction (XRD).