• Title/Summary/Keyword: Pulse duration

Search Result 511, Processing Time 0.023 seconds

Model Predictive Power Control of a PWM Rectifier for Electromagnetic Transmitters

  • Zhang, Jialin;Zhang, Yiming;Guo, Bing;Gao, Junxia
    • Journal of Power Electronics
    • /
    • v.18 no.3
    • /
    • pp.789-801
    • /
    • 2018
  • Model predictive direct power control (MPDPC) is a widely recognized high-performance control strategy for a three-phase grid-connected pulse width modulation (PWM) rectifier. Unlike those of conventional grid-connected PWM rectifiers, the active and reactive powers of permanent magnet synchronous generator (PMSG)-connected PWM rectifiers, which are used in electromagnetic transmitters, cannot be calculated as the product of voltage and current because the back electromotive force (EMF) of the generator cannot be measured directly. In this study, the predictive power model of the rectifier is obtained by analyzing the relationship among flux, back EMF, active/reactive power, converter voltage, and stator current of the generator. The concept of duty cycle control in the proposed MPDPC is introduced by allocating a fraction of the control period for a nonzero vector and rest time for a zero vector. When nonzero vectors and their duration in the predefined cost function are simultaneously evaluated, the global power ripple minimization is obtained. Simulation and experimental results prove that the proposed MPDPC strategy with duty cycle control for the PMSG-connected PWM rectifier can achieve better control performance than the conventional MPDPC-SVM with grid-connected PWM rectifier.

Partial Discharge Detection for the Power Cables using AC and Oscillating wave Voltage (전력케이블에서 교류전압과 진동파 전압을 이용한 부분방전 측정)

  • Kim, Jeong-Tae;Kim, Nam-Jun;Lee, Jeon-Seon;Gu, Ja-Yun
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.4
    • /
    • pp.247-252
    • /
    • 1999
  • In this paper, in order to investigate availability of the OW-PD measurement method which has been proposed as an alternative of AC-PD measurement method to an after laying test and/or diagnosis for the power cable system, partial discharges owing to the needle-type defect integrated into the cable have been measured using AC and OW(Oscillating Wave) voltages. In the AC-PD measurement, the magnitude, phase and pulse number of partial discharges have been changed with the duration of voltage application, which can be analyzed through the relation with the process of the electrical tree initiation and propagation. In addition, the characteristics of partial discharges using OW voltage are appeared to be similar to those in case of AC-PD measurement and to be different with the shapes of electrical tree. From these results, it is concluded that the OW-PD measurement method is available to the tests for the cable system.

  • PDF

Study of Multichannel Pseudo-spark Switch for High-voltage and High-current (고전압 대전류 Multichannel Pseudo-spark 스위치 연구)

  • Park, S.S.;Han, Y.J.;Kim, S.H.;Kwon, Y.K.;Kim, S.H.;Park, Y.J.;Nam, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1859-1861
    • /
    • 2002
  • This paper attempts to discuss the pseudo-spark which is developed for high voltage and high current. The pseudo-spark switch is on the basic of the Paschen's law. The pseudo-spark switch fabricates the glass chamber. The pseudo-spark switch consists of hollow cathode, hollow anode, and trigger. The pseudo-spark switch is operated at the voltage of 20 kV and the pressure range of $20{\sim}80$ mtorr with He-gas. The switching current of the pseudo-spark switch was measured as 65 kA, and the duration of the pulse was about 100 ${\mu}s$. This paper describes the results of tests and the characteristics of the switch.

  • PDF

Development of surface electrode type electrical stimulator or supporting walk function in foot drop patients (족하수 환자에서의 보행기능 보조를 위한 표피 자극형 전기자극기 개발)

  • Lim, S.K.;Jeong, H.C.;Kim, K.G.;Jin, D.B.;Park, B.R.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.9-13
    • /
    • 1997
  • The present study was designed to develop the functional electrical stimulation system in order to restore motor function of paralytic patients. We attempt to establish adequate stimulus parameters for the recovery of work unction in lower limb paralysis patients and to develop the electrical stimulation system, which is effective to protect foot drop in these patients. In our animal and human experiment, adequate stimulus condition for surface electrode on the lower limb were 0.2-0.3ms at the duration and 50 Hz, which contain 600Hz train pulse. This parameter has efficiently prevented the foot drop from lower limb paralysis, decreased muscle fatigue and induced powerful contraction of lower limb muscle.

  • PDF

Electrochemical Machining Using Tungsten Microelectrode (텅스텐 미세 전극을 이용한 전해 가공)

  • Ryu, Shi-Hyoung;Yu, Jong-Sun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.4
    • /
    • pp.134-140
    • /
    • 2009
  • The feasibility of electrochemical drilling and milling on stainless steel are investigated using tungsten microelectrode with $10{\mu}m$ in diameter. For the development of environmentally friendly and safe electrochemical process, citric acid solution is used as electrolyte. A few hundred nanoseconds duration pulses are applied between the microelectrode and work material for dissolution localization. Tool fracture by Joule heating, micro welding, capillary phenomenon, tool wandering by the generated bubbles are observed and their effects on micro ECM are discussed. Occasionally, complex textures including micro pitting corrosion marks appeared on the hole inner surface. Metal growth is also observed under the weak electric conditions and it hinders further dissolutions for workpiece penetration. By adjusting appropriate pulse and chemical conditions, micro holes of $37{\mu}m$ in diameter with $100{\mu}m$ in depth and 26Jim in diameter with $50{\mu}m$ in depth are drilled on stainless steel 304. Also, micro grooves with $18{\mu}m$ width and complex micro hand pattern are machined by electrochemical milling.

Subarachnoid Morphine for Perianal Postoperative Pain Control (미양(微量) Morphine 지주막하(蜘蛛膜下) 주입(注入)에 의(依)한 항문각위술후(肛門脚圍術後) 제통효과(除痛效果)에 대(對)한 임상연구(臨床硏究))

  • Rhim, Hwa-Taeg;Lee, Yeong-Sik;Oh, Hung-Kun
    • The Korean Journal of Pain
    • /
    • v.1 no.1
    • /
    • pp.98-102
    • /
    • 1988
  • In order to control the pain after hemorrhoidectomy and anal fistulectomy, 6 mg of 0.5% hyperbaric tetracaine without(control, group I) or wilt 0.3 mg(group II) or 0.5 mg (group III) of 0.1% morphine was injected with a 22 gauge spinal needle into the subarachnoid space through L 3-4 interspace of patients in lateral position. About 30 minutes in Fowler' sposition after injection, operation was performed in lithotomy position. All the patients who ha4 morphine showed remarkable relief of postoperative pain for an average of 27 hours. However, the dosage(0.3 or 0.5 mg) of morphine administered did not affect the duration of pain relief. Blood pressure, pulse rate and pupil size were unchanged in all patients. Dysuria after block developed for on average of 5,6, 13.2 and 14.6 hours in group I, II and III respectively. Most of these cases required urethral catheterization. Minor complications such as nausea, vomiting, itching, fever, burning sensation and paresthesia were observed 16.7, 20 and 20% of cases in group I, II and III respectively; however, no treatment was required.

  • PDF

Transport Properties of Conversion Materials for Digital Radiography

  • Kim, Jae-Hyung;Park, Chang-Hee;Nam, Sang-Hee
    • Transactions on Electrical and Electronic Materials
    • /
    • v.8 no.6
    • /
    • pp.250-254
    • /
    • 2007
  • Applying the moving photo-carrier grating(MPG) technique and time-of-flight(TOF) measurements, we studied the transport properties of stabilized amorphous selenium typical of the material used in direct conversion X-ray imaging devices. For MPG measurement, we obtained electron and hole mobility and the recombination lifetime of $\alpha-Se$ films with arsenic(As) additions. We found an apparent increase in hole drift mobility and recombination lifetime, especially when 0.3 % As was added into $\alpha-Se$ film, whereas electron mobility decreased with the addition of As due to the defect density. For TOF measurement, a laser beam with pulse duration of 5 ns and wavelength of 350 nm was illuminated on the surface of $\alpha-Se$ with a thickness of 400 ${\mu}m$. The measured hole and electron transit times were about 8.73 ${\mu}s$ and 229.17 ${\mu}s$, respectively.

Simmyung Laser System and Study on the X-ray Generation (신명 레이저와 X-선 발생 연구)

  • Kong, Hong-Jin;Han, Ki-Gwan;Kim, Nam-Seong;Kim, Hyun-Soo;Um, Ki-Young;Park, Jong-Rak;Lee, Jae-Youg;Shin, Yun-Sup;Han, Ki-Ho
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1995.06a
    • /
    • pp.185-189
    • /
    • 1995
  • A high-power Nb:glass laser system(Simmyung I) has been contructed and tested. In this system, we used a Nb:YLF laser as a master oscillator, a 4-pass amplifier for pre-amplification, 5 stages of rod amplifiers, and spatial filtering and image reaying usits. The system has demonstrated in excess of 80J(2TW) with 40 psec(FWHM) pulse duration. Output energy, gain and spatial were measured at each amplification stage. With this laser system a preliminary X-ray generation experiment was performed. Pinhole images, X-ray diode signals and X-ray speriment were obtained for the irradiated target of copper. Detailed descriptions of the system performance and the X-tay generation experiment are presented.

  • PDF

Optical Limiting Properties of Multi-Walled Carbon Nanotube Suspensions (다중벽 탄소 나노튜브 현탁액의 광 리미팅 특성)

  • Yu Hyojung;Kim Sok Won
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.5
    • /
    • pp.449-454
    • /
    • 2004
  • The optical limiter is an optical component which reduces laser beam intensity for the protection of eyes and light sensors. Carbon nanotube is now known as a highly efficient optical limiting material. Optical limiting effect of the multi-walled carbon nanotube suspensions, in several kinds of solvents such as distilled water, chloroform, ethanol and ethylene glycol, were measured in the range from room temperature to near to the boiling points of the solvents. The pulsed Nd:YAG laser whose wavelength is 1064 nm and pulse duration is 6 ns was used as a light source. The experimental result shows that the limiting efficiency was reduced as the temperature increased, and the suspension which has lower boiling point, viscosity and surface tension has highest efficiency.

Measurement of the discharge characteristics of liquid nitrogen at atmospheric pressure by personal computer system (컴퓨터 시스템에 의한 대기압하(大氣壓下)에서 액체질소($LN_2$)의 방전특성측정(放電特性測定))

  • Ju, Jae-Hyun;Lee, Young-Gun;Kim, Sang-Ku;Jeon, Young-Ju;Lee, Kwang-Sik;Lee, Dong-In
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1530-1532
    • /
    • 1994
  • This paper describes the discharge characteristics of liquid nitrogen for plane-plane, needle-plane electrode at variation of gap spacing at atmospheric pressure. The important results obtained from this study are as follows. (1) Breakdown voltage of $LN_2$ for needle-plane electrode is higher than that of for plane-plane electrode and discharge duration tine is longer with increase of gap spacing at atmospheric pressure. (2) The formation of bubbles by evaporation is observed in spite of non-applying source at atmospheric pressure and the creation of corona confirmed for plane-plane electrode results from the bubbles. (3) The applied voltage-discharge magnitude( V-Q) characteristics of $LN_2$ showed hysteresis and the discharge magnitude decreasing and corona voltage increasing proportional to the pulse per second at atmospheric pressure.

  • PDF