• Title/Summary/Keyword: Pulse design

Search Result 1,439, Processing Time 0.027 seconds

Experimental Study on the Performance Characteristics for the Three Types of the Pulse Tube Refrigerators (맥동관 냉동기의 유형별 성능특성에 관한 실험적 연구)

  • Park, Seong-Je;Go, Deuk-Yong
    • 연구논문집
    • /
    • s.24
    • /
    • pp.27-39
    • /
    • 1994
  • lower vibration than in any other small refrigerators. The experimental results of three types of pulse tube refrigerators are presented in this paper. The objectives of this study are to develop the design technology of the double inlet pulse tube refrigerator and acquire its application method. As a preliminary experiment, the refrigeration performances of the basic, orifice and double inlet pulse tube refrigerator were investigated. The lowest temperature obtained in this experiment was 34.4K. The refrigeration capacity at the optimum operating condition of the double inlet pulse tube refrigerator was 23W at 80K.

  • PDF

A Study on the Arterial Pulse Wave Measuring System of an Oral Cavity (구강 내부 맥파 계측을 위한 센서 시스템 연구)

  • Kim, Kyung-Ho
    • Journal of the Semiconductor & Display Technology
    • /
    • v.6 no.4
    • /
    • pp.43-47
    • /
    • 2007
  • In this paper, we propose a novel sensor system for measuring the arterial pulse in an oral cavity. In order to measure pulse wave in oral cavity, the proposed system is designed with reflection type arterial wave sensor, not by using transmission type arterial pulse wave sensor. Driving circuit through pulse current is designed for solving self-heating problem of LED. The effectiveness of the proposed sensor system is compared with pulse wave between pulse wave of oral cavity and other body parts as well as with characteristic measurements. The experiment shows that the proposed sensor system is adaptive to capturing consecutive and meaningful biometric signals through the variation of pulse wave changes in oral cavity when exercising. The study result expects to design and develop mobile sensors which could be adapted to healthcare devices.

  • PDF

Application to the design of reduced-order robust MPC and MIMO identification

  • Lee, Kwang-Soon;Kim, Sang-Hoon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.313-316
    • /
    • 1997
  • Two different issues, design of reduced-order robust model predictive control and input signal design for identification of a MIMO system, are addressed and design techniques based on singular value decomposition(SVD) of the pulse response circulant matrix(PRCM) are proposed. For this, we investigate the properties of the PRCM, which is a periodic approximation of a linear discrete-time system, and show its SVD represents the directional as well as the frequency decomposition of the system. Usefulness of the PRCM and effectiveness of the proposed design techniques are demonstrated through numerical examples.

  • PDF

A Design Study on Superconducting Monolith For Superconducting Pulse Magnet (초전도펄스 마그네트 선재설계에 관한 연구)

  • 노완수;한송엽;황석영;이승원
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.8
    • /
    • pp.805-812
    • /
    • 1990
  • In this paper, a design on the superconducting monolith for superconducting pulse magnet is described. Both stability and AC loss parameters are used in the design process, which restricted various design parameters. Determined design parameters satisfy both stability and AC loss restrictions. Finally superconducting monolith is flattened, fitting for magnet and acquiring transposition effect.

  • PDF

Effectiveness of design procedures for linear TMD installed on inelastic structures under pulse-like ground motion

  • Quaranta, Giuseppe;Mollaioli, Fabrizio;Monti, Giorgio
    • Earthquakes and Structures
    • /
    • v.10 no.1
    • /
    • pp.239-260
    • /
    • 2016
  • Tuned mass dampers (TMDs) have been frequently proposed to mitigate the detrimental effects of dynamic loadings in structural systems. The effectiveness of this protection strategy has been demonstrated for wind-induced vibrations and, to some extent, for seismic loadings. Within this framework, recent numerical studies have shown that beneficial effects can be achieved by placing a linear TMD on the roof of linear elastic structural systems subjected to pulse-like ground motions. Motivated by these positive outcomes, closed-form design formulations have been also proposed to optimize the device's parameters. For structural systems that undergo a near-fault pulse-like ground motion, however, it is unlikely that their dynamic response be linear elastic. Hence, it is very important to understand whether such strategy is effective for inelastic structural systems. In order to provide new useful insights about this issue, the paper presents statistical results obtained from a numerical study conducted for three shear-type hysteretic (softening-type) systems having 4, 8 and 16 stories equipped with a linear elastic TMD. The effectiveness of two design procedures is discussed by examining the performances of the protected systems subjected to 124 natural pulse-like earthquakes.

Coil Design of Pulse Induction Metal Detector (펄스 유도 방식의 금속탐지기 코일 설계)

  • Jung, Byung-Min;Chang, Yu-Shin;Han, Seung-Hoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.4
    • /
    • pp.389-396
    • /
    • 2015
  • A coil design of pulse induction metal detectors has been described. The search coil was demonstrated by using the wire with the diameter of 0.3 mm, 0.5 mm and 1.0 mm and the dielectric plate with the $30cm{\times}30cm$ and $35cm{\times}35cm$, the time constant and the currents of the coil as the variation of the coil size and the number of coil turns was characterized. The coil parameters like the resistance, the inductance and the time constants as the variation of the diameter of the wire, the coil size and the number of coil turns were compared and analysed through the calculation and the measurement. In addition, investigating the coil currents as the variation of the input pulse width, the coil design of pulse induction metal detectors has been discussed.

Mutual interference suppression of the sinusoidal frequency modulated pulse using SHAPE algorithm (SHAPE 알고리즘을 이용한 사인파 주파수 변조 펄스의 상호간섭 억제)

  • Kim, Guenhwan;Lee, Donghwa
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.27 no.5
    • /
    • pp.49-59
    • /
    • 2022
  • The SHAPE algorithm has the advantage of being able to shape the pulse spectrum as desired and design it not to distort other characteristics, so it was used in the active sonar pulse design. In this paper, we propose a pulse design using the SHAPE algorithm for a multi-static sonar system to reduce the cross-correlation between frequency-adjacent pulses and prevent the performance degradation of the pulses themselves. The boundary function of the SHAPE algorithm is set to be limited to the pulse bandwidth. As a result of applying the proposed design method to the sinusoidal frequency modulated pulse, the peak cross-correlation level (PCCL), which means the degree of cross-correlation, was reduced by 44.23 dB. Although the PCCL decreased by several tens of dB, no significant change in the ambiguity function was observed, and the integrated sidelobe level (ISL), which means the average value of the side lobe, increased by 11.64 dB.

Mini loop coil magnetic curer for peripheral nervous system treatment (말초신경계 치료를 위한 미니 Loop - 코일 삽입형 자기치료기)

  • Kim, Whi-Young
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.49-51
    • /
    • 2007
  • It is as result that study to apply mini magnet nerve curer in peripheral nervous system disease treatment. Design and embodied action power and Control Unit in cylinder form of magnet roof object firstly. Yielded service area about special quality of probe of roof object cylinder style and treatment area dimension and distance of treatment pulse secondly. Embody pulse forming course energy value by Probe's form by third, could embody treatment pulse by disease. Specially, through a special quality experiment, saved Damping pulse torn and treatment pulse form etc. variously. Lately, embodied this to aid a little in disease treatment that follow that there is no invasion that there is no stimulation by medicine development. Go amplitude treatment pulse (traditional magneto-therapy of greatly great that strong) does curative effect greatest at short time and becomes thought that demand is magnified greatly at the future in this research.

  • PDF

Localized Oxidation of (100) Silicon Surface by Pulsed Electrochemical Processes Based on AFM (AFM 기반 Pulse 를 이용한 전기화학적 가공)

  • Lee, Jeong-Min;Kim, Sun-Ho;Park, Jeong-Woo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.11
    • /
    • pp.1631-1636
    • /
    • 2010
  • In this study, we demonstrate a nano-scale lithograph obtained on localized (100) silicon (p-type) surface using by modified AFM (Atomic force microscope) apparatuses and by adopting controlling methods. AFM-based experimental apparatuses are connected to a customized pulse generator that supplies electricity between the conductive tip and the silicon surface, while maintaining a constant humidity throughout the lithography process. The pulse durations are controlled according to various experimental conditions. The electrochemical reaction induced by the pulses occurs in the gap between the conductive tip and silicon surface and result in the formation of nanoscale oxide particles. Oxide particles with various heights and widths can be created by AFM surface modification; the size of the oxide particle depends on the pulse durations and the applied electrical conditions under a humid environment.

A Study on the Welding Behavior of A3003 Aluminium Alloy Thin Sheet by Nd : YAG Laser Beam (박판 A3003 Al합금의 Nd : YAG 레이저빔 용접에 관한 연구)

  • 허인석;김병철;김도훈;김진수;이한용
    • Laser Solutions
    • /
    • v.4 no.1
    • /
    • pp.29-38
    • /
    • 2001
  • This work was carried out to investigate the welding behavior of thin A3003 Al alloy sheets by Nd : YAG laser beam. Considering bead shape and mechanical properties, the laser pulse shapes selected were two kinds of 2-division and 3-division by varying power level and pulse duration. In order to obtain optimum conditions, the factorial design method and central composite design method were applied. Tensile test, optical microscopy, micro hardness test and TEM analysis were performed. Due to the annealing caused by thermal effect during laser welding, precipitates were coarsended. The HAZ was softened and failed during tensile test. The hardness of HAZ was lower than that of base metal, since the heat input relieved the work hardening effect and caused grain growth.

  • PDF