• 제목/요약/키워드: Pulse analyzing system

Search Result 52, Processing Time 0.026 seconds

Implementation of Efficient Pile-up Pulse Processing Algorithm Based on Trapezoidal Filter (사다리꼴 필터를 이용한 효율적인 중첩펄스 처리 알고리즘 구현)

  • Piao, Zheyan;Chung, Jin-Gyun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.8
    • /
    • pp.162-167
    • /
    • 2013
  • X-ray or ${\gamma}$-ray spectroscopy systems are widely used for analyzing material characteristics. Pile-up pulses are very often encountered for several reasons in XRF systems. Thus, it is necessary to reject or recover pile-up pulses to accurately analyze the material under test. In this paper, a pile up pulse rejection and recovery method is presented for XRF systems using trapezoidal pulse shaping of the input signals. Since the proposed method is based on the trapezoidal pulse shaping method widely-used in XRF systems, only two counters and a few registers are needed to implement the additional function of pile-up pulse rejection and recovery. Consequently, the proposed system is much simpler than conventional pulse reconstruction systems. It is shown that the proposed method can detect and reject pile-up pulses exactly. It is also shown that the pile-up pulses can be recovered if some conditions are satisfied.

Poling Quality Enhancement of PPLN Devices Using Negative Multiple Pulse Poling Method

  • Choi, Ju-Won;Ro, Jung-Hoon;Ko, Do-Kyeong;Yu, Nan-Ei
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.182-186
    • /
    • 2011
  • A poling method using multiple negative voltage was introduced to fabricate periodically poled lithium niobate (PPLN) devices with quasi-phase matching (QPM) period of $12.9\;{\mu}m$ by utilizing an real-time visualization system. We also performed variation of the electric field during the poling. Two different conventionally used poling method, negative and positive single pulses, were used and the poling quality compared through microscopic images and far-field diffraction pattern analysis. Etched images on the +z and -z surfaces of PPLN showed that negative multiple pulse poling presented the highest periodicity in domain structures among the three methods. Duty ratio and its standard deviation were measured by analyzing far-field diffraction patterns. The newly introduced method of negative multiple pulse poling had duty ratio of 0.42 which was close to the ideal value of 0.50 and standard deviation of 0.020 that was about 3 times smaller than that of the other conventional methods.

A Study on the Direction of Developing a Simulator for Performance Evaluation of Pulse Wave Detectors Through a Review of the Development Status of Cardiovascular Simulators (심혈관계 시뮬레이터 개발 동향 분석을 통한 맥파검사용기기 성능평가 시뮬레이터 연구개발 방향 모색)

  • Lee, Ju-Yeon;Kim, Jaeyoung;Go, Dong-Hyun;Lee, Ji-Won;Lee, Tae-Hee;Park, Chang-Won;Lee, Su-Kyoung
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.3
    • /
    • pp.136-146
    • /
    • 2022
  • In this study, it is intended to provide basic data that can help develop a cardiovascular simulator for performance evaluation of pulse wave detectors by identifying the development status of domestic and overseas cardiovascular simulators. A total of 119 papers were selected by excluding duplicate literature, gray literature, and literature not related to a cardiovascular simulator. Based on the selected literature, the research trend of cardiovascular simulators was analyzed. As a result of analyzing the purpose of the study, most of the simulators were developed to evaluate the hemodynamic properties of artificial hearts and valves. In addition, it was used for simulation evaluation or hemodynamic studies such as pulse wave studies. As a result of analyzing configurations of the simulators, a heart most often consisted of only one left ventricle. For blood vessels, the Windkessel model was most often constructed using chambers and valves. In most studies, blood was reproduced by mixing glycerin and water to reproduce both density and viscosity. In addition, as a result of analysis from the perspective of medical device performance evaluation, simulators for evaluating artificial heart and artificial valves have been studied a lot, whereas simulators for blood pressure, pulse wave, and blood flow devices have been relatively insignificant. Based on the review results, we suggested considerations when developing a simulator for performance evaluations of a pulse wave detector.

Design and Fabrication of a LabView Based Partial Discharge Analyzer (LabView 기반 부분방전 분석장치의 설계 및 제작)

  • Cha, Hyeon-Kyu;Lee, Jung-Yoon;Park, Dae-Won;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.3
    • /
    • pp.229-235
    • /
    • 2012
  • This paper dealt with the fabrication of a partial discharge (PD) analyzer for insulation diagnosis of power facilities like transformers, cables and gas-insulated switchgears. An analytic algorithm for the phase (${\phi}$), the magnitude (q), and the pulse count (n) of PD pulse was designed and a time-frequency (TF) map algorithm was applied in the system to eliminate noises by analyzing the time and the frequency component of signals. All the algorithms were operated by a LabView graphical program. The detection circuit consists of a coupling capacitor, a detection impedance, and a low noise amplifier. A plane-plane and a point-plane electrode system were fabricated to simulate different types of insulation defects. In the experiment, we could easily understand the characteristics of PD pulses using the prototype PD analyzer.

Performance Analysis of SSSC with Switching-level Simulation Model and Scaled Hardware Model

  • Han, Byung-Moon;Kim, Hee-Joong;Baek, Seung-Taek
    • Journal of Power Electronics
    • /
    • v.1 no.1
    • /
    • pp.48-55
    • /
    • 2001
  • This paper describes a switching-level simulation model and scaled hardware model for SSSC, which is useful for analyzing the dynamic interaction between the SSC and the power transmission system. A detailed simulation model with EMTP was developed to verity the SSSC operation with control system, and its increasing capability of power transmission through the line for a typical one-machine infinite-bus system. The simulation results of the developed model are compared with the experimental results froma scaled model fo 2KVA rating for evaluation the whole system operation.

  • PDF

Gap Control Using Discharge Pulse Counting in Micro-EDM (미세 방전 가공에서의 방전 펄스 카운팅을 이용한 간극 제어)

  • Jung J.W.;Ko S.H.;Jeong Y.H.;Min B.K.;Lee S.J.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.499-500
    • /
    • 2006
  • The electrode wear in micro-EDM significantly deteriorates the machining accuracy. In this regard, electrode wear needs to be compensated in-process to improve the product quality. Therefore, there are substantial amount of research about electrode wear. In this study a control method for micro-EDM using discharge pulse counting is proposed. The method is based on the assumption that the removed workpiece volume is proportional to the number of discharge pulses, which is verified from experimental results analyzing geometrically machined volume according to various number of discharges. Especially, the method has an advantage that electrode wear does not need to be concerned. The proposed method is implemented to an actual micro-EDM system using high speed data acquisition board, simple counting algorithm with 3 axis motion system. As a result, it is demonstrated that the volume of hole machined by EDM drilling can be accurately estimated using the number of discharge pulses. In EDM milling process a micro groove without depth variation caused by electrode wear could be machined using the developed control method. Consequently, it is shown that machining accuracy in drilling and milling processes can be improved by using process control based on the number of discharge pulses.

  • PDF

Determination of measuring time for decision of heavy metal ion concentration in Square Wave Voltammetry with FPGA (FPGA를 이용한 네모파 전압전류법의 계측시간 분석)

  • Lee, Jaechoon
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.12 no.4
    • /
    • pp.25-31
    • /
    • 2016
  • In this research, to analyze the concentration of heavy metal ions in water, we tried to find the measuring time at which the faradaic electric currents flowing by the pure oxidation-reduction reaction from the pushing up mercury electrode of the stripping scan square wave voltammetry(SV+SWV) methods system becomes larger than the capacitance electric current. In order to do this, a method for analyzing signals using FPGA has been designed and we conducted 120 experiments using it. As a result, when the frequency of the square wave is 40Hz, The valid potential-current signal was measured from 96.6667% to 96.7155% of the end of the pulse of the forward and reverse, and the optimal signal was measured at 96.6667%. In addition, the experiment was carried out 40 times by changing the pulse height of the square wave from 10Mv to 40Mv. As a result, at a size smaller than 40Mv, there is little change in the magnitude of the potential-current, and an invalid signal was generated when it is out of this size.

Test Results of Pulsed Power Supply for Nonthermal Plasma Process (저온 플라즈마 공정용 펄스발생 전원장치의 성능시험)

  • Jang, S.D.;Byun, Y.C.;Cho, M.H.;Shin, D.N.
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1574-1575
    • /
    • 2011
  • The application of a pulsed power system is being extended to an environmental and industrial field. The non-destructive gaseous pollutants from industrial plants such as power generation plants and incinerators can be processed by applying high voltage pulses with a fast rising time (a few nanoseconds) and short duration (nano to microseconds) in a pulsed corona discharge reactor. The pulsed plasma generator with a triggered switch has been developed. Its corona current in load can be adjusted by applied voltage and repetition rate. We investigated the performance of the pulsed plasma generator by analyzing the concentration of ozone in small reactor. This paper describes the electrical characteristics of the pulse generator with a voltage of 30 kV at repetition rate of 50 PPS. In addition, we briefly discuss a configuration of the system and initial test results.

  • PDF

A Study on the Ontology-Based Context Aware System for MBAN (MBAN(Medical Body Area Network)에서의 온톨로지 기반 상황인지 시스템 개발에 관한 연구)

  • Wang, Jong Soo;Lee, Dong Ho
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.7 no.1
    • /
    • pp.19-29
    • /
    • 2011
  • The u-Healthcare system, a new paradigm, provides healthcare and medical service anytime, anywhere in daily life using wired and wireless networks. It only doesn't reach u-Hospital at home, to manage efficient personal health in fitness space, it is essential to feedback process through measuring and analyzing a personal vital signs. MBAN(Medical Body Area Network) is a core of this technology. MBAN, a new paradigm of the u-Healthcare system, can provide healthcare and medical service anytime, anywhere on real time in daily life using u-sensor networks. In this paper, an ontology-based context-awareness in MBAN proposed system development methodology. Accordingly, ontology-based context awareness system on MBAN to Elderly/severe patients/aged/, with measured respiratory rate/temperature/pulse and vital signs having small variables through u-sensor network in real-time, discovered abnormal signs and emergency situations which may happen to people at sleep or activity, alarmed and connected with members of a family or medical emergency alarm(Emergency Call) and 119 system to avoid sudden accidents for early detection. Therefore, We have proposed that accuracy of biological signal sensing and the confidence of ontology should be inspected.

The Stabilized Speed Control Modeling of Single-side Linear Induction Motor Considering End-effect (단부효과가 고려된 편측형 선형유도전동기의 안정속도제어 모델링)

  • Lim, Hong-Woo;Chae, Bong;Choi, Moon-Han;Lee, Kang-Yeon;Cho, Geum-Bae;Baek, Hyung-Lae
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.3
    • /
    • pp.266-273
    • /
    • 2006
  • In difference with the rotary type electrical machinery, the single-sided linear induction motor(SLIM) that generates the direct thrust, is widely used for the operation system of electrified railroad, lope-less elevation system, conveyer system, and so on. The operational principle of single-sided linear induction motor is constructively similar to the general rotary Induction motor It Is difficult to realize the complicate linear induction motor which is applied space vector pulse width modulation(SVPWM) system, but widely used in vector motor control system or servo control system because of its high performance in current control. In this paper, we has modeled the dynamic characteristic analyzing methode, and calculated efficiently the end effect by using equivalent circuit methode in the operating linear Induction motor control system.