• Title/Summary/Keyword: Pulse Waves

Search Result 307, Processing Time 0.024 seconds

AN ULTRASONIC METHOD FOR VIBRATION MEASUREMENT OF THE SUSPENSION IN HARD DISK DRIVES (하드디스크 서스펜션의 초음파 진동측정 기술)

  • Ha, Wan;Kim, Noh-Yu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.720-725
    • /
    • 2000
  • A new ultrasonic pulse-echo technique was developed and described for vibration measurement of the suspension assembly in hard disk drives. The method is based upon the difference in magnitude of two consecutive reflection waves from a moving object(suspension), while the traditional ultrasonic vibrometer uses the phase shift of the reference wave and the reflection wave. A cone-shape delay line is designed to access the small structure. A simple mathematical model is presented and analyzed with experimental results to show the feasibility of the method. The advantages of this ultrasonic vibration measurement method are relatively high resolution, low cost, and ease of implementation comparing with the Laser Doppler vibrometer.

  • PDF

An Efficient Focusing Method for High Resolution Ultrasound Imaging

  • Kim Kang-Sik
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.1
    • /
    • pp.22-29
    • /
    • 2006
  • This paper proposes an efficient array beamforming method using spatial matched filtering for ultrasound imaging. In the proposed method, ultrasound waves are transmitted from an array subaperture with fixed transmit focus as in conventional array imaging. At receive, radio frequency (RF) echo signals from each receive channel are passed through a spatial matched filter that is constructed based on the system transmit-receive spatial impulse response. The filtered echo signals are then summed. The filter remaps and spatially registers the acoustic energy from each element so that the pulse-echo impulse response of the summed output is focused with acceptably low side lobes. Analytical beam pattern analysis and simulation results using a linear array show that the proposed spatial filtering method can provide more improved spatial resolution and contrast-to-noise ratio (CNR) compared with conventional dynamic receive focusing (DRF) method by implementing two-way dynamically focused beam pattern throughout the field.

The Integrity Evaluation of weld zone in railway rails Using Neural Network (신경회로망을 이용한 철도레일 용접부의 건전성평가)

  • 윤인식;임미섭
    • Journal of the Korean Society for Railway
    • /
    • v.6 no.2
    • /
    • pp.81-86
    • /
    • 2003
  • This study proposes the neural network simulator for the integrity evaluation of weld zone in railway rails. For these purposes, the ultrasonic signals for defects(crack) of weld zone in frames are acquired in the type of time series data and echo strength. The detection of the natural defects in railway truck is performed using the characteristics of echodynamic pattern in ultrasonic signal. And then their applications evaluated feature extraction based on the time-frequency-attractor domain(peak to peak, rise time, rise slope, fall time, fall slope, pulse duration, power spectrum, and bandwidth) and attractor characteristics (fractal dimension and attractor quadrant) etc. The constructed neural network simulator agrees fairly well with the measured results of test block(defect location, beam propagation distance, echo strength, etc). The Proposed neural network simulator in this study can be used for the integrity evaluation of weld zone in railway rails.

A Study of the Therapeutic Effects of Ginseng on Chi-deficiency Syndrome with Sphygmography (맥파계법을 이용한 인삼의 기부족 증상 치료효과에 관한 연구)

  • Chang Hen-Hong;Shen Yung-Yu;Chan Yat-Kwong;Wang Shu-Yu;Ma Chien-Chung
    • Proceedings of the Ginseng society Conference
    • /
    • 1988.08a
    • /
    • pp.70-76
    • /
    • 1988
  • Since ancient times, records pertaining to chi-reinforecenent of ginseng have been documented in books of Chinese nedicine. We, therefore, assessed the therapeutic effects of ginseng on patients with chi-deficiency syndrome. Eigheen cases of chi-deficiency, screened at the outpatient service in the internal department of Chinse medicine at the China Medical College Hospital. were prescribed two grams of Korean red ginseng powder three times daily for a two week period. For evaluation, a questionnaire and diagnosis by sphygmography were conducted prior to and after administration of the prescription. For control purposes, fourteen volunteers fasted for more than five days (seven had access only to ginseng. and the other seven were given only mineral water) and were subsequently evaluated by the same criteria. Three results were obtained for the ginseng treated group: (1) improvements in symptoms of chi-deficiency such as fatigue and dizziness; (2) changes in pulse waves with time domains showing alternate P-waves, strengthened dicrotic waves, and some minute waves in the end-diastolic period; (3) frequency domains with enhanced amplitudes around 12Hz. These three findings, which are consistent with each other, suggest the reinforcement of the effect of ginseng on 'heart-spleen chi' in Chinese medicine.

  • PDF

Development of an EMAT System for Detecting flaws in Pipeline (배관결함 검출을 위한 EMAT 시스템 개발)

  • Ahn, Bong-Young;Kim, Young-Joo;Kim, Young-Gil;Lee, Seung-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.1
    • /
    • pp.15-21
    • /
    • 2004
  • It is possible to detect flaws in pipelines without interruption using all EMAT transducer because it is a non-contact transducer which can transmit ultrasonic waves into specimens without couplant. And it ran easily generate guided waves desired in each specific problem by altering the design of coil and magnet. In the present work, EMAT systems have been fabricated to generate surface waves, and selectively the plate wave of $A_1\;or\;S_1$ mode. The surface wave of 1.5MHz showed a good signal-to-noise ratio without distortion in its propagation along a pipeline, while the $S_1$ mode of 800kHz and the $A_1$ mode of 940kHz were distorted according to their dispersive properties. The wider the excitation pulse becomes, the better the mode selectivity of the plate waves becomes. A pipe of 256mm inner diameter and 5.5m thickness with 5 flaws was used for comparing the flaw detectability among the modes under consideration.

A Study for Antistress Effects of Two Aromatic Synergic Blending Oils (아로마 에센셜 오일의 항스트레스효과에대한 연구 - 뇌파 검사를 중심으로-)

  • Choi, Jin-Yong;Oh, Hong-Keun;Chun, Kyum-Ku;Lee, Jun-Suk;Park, Dong-Ki;Choi, Sung-Don;Chun, Tae-Il;Kim, Mi-Kyung;Kim, Suk-Bum
    • Annals of Clinical Neurophysiology
    • /
    • v.2 no.2
    • /
    • pp.70-80
    • /
    • 2000
  • Purpose : This study was performed to evaluate the antistress effects of two aromatic blends being composed of synergic essential oils and also to differentiate its effectiveness between two. Methods : The subject were 20(10 for men, 10 for women) for vital factors and another 20(10 for mem, 10 for women) for serum catecholamine. Vital factors(blood pressure, pulse), electroencephalograpy, psychological tests(SACL, STAI) and serum catecholamine were applied to the subjects. Results : 1. All two aromatic synergic blends revealed no significant differnce of vital factors after inhalation but stable conditions generally by lowering pulse and blood pressure after inhalation. 2. Both blends were significantly valuable in antianxiety and antistress effects statistically. There were no statistically difference between two blends. 3. There were no significant difference in all brain waves after inhalation of two blends but generally stable brain waves were seen in all areas. 4. There were antistress effects of both blends in accordance of decreased serum catecholamines after inhalation of both blends. There were no significantly difference between two blends statistically. Conclusion : Both two aromatic synergic blends reached effective antistress and antianxiety states after inhalation of each blends. There were no significant difference between two blends. Further studies about the effectiveness between the amount of aromatic essential oils and the duration of inhalation should be considered. Also clinical applications of these two aromatic synergic blending oils to develop the aromatic products would be affordable in the future.

  • PDF

A Pulse-Echo Testing Model for Partially Damaged Ultrasonic Transducers (부분 손상을 입은 초음파 탐촉자의 펄스-에코 시험 모델)

  • Song, Sung-Jin
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.16 no.2
    • /
    • pp.95-108
    • /
    • 1996
  • In ultrasonic testing, flaw signal from which quantitative information on flaws is determined is influenced by 3 factors : (1) the incident wavefield.produced by the transducer, (2) the scattered waves produced by flaws, and (3) the reception of the scattered waves back at the transducer. So even small changes in transducer performance due to aging or unexpected damages can produce the changes in the characteristics of flaw signal and finally the changes in the quantitative information on flaws. Thus a reliable calibration method of transducer performance is desired. Recently, theoretical models for ultrasonic testing have been employed as reference standards for the calibration of transducers which are considered as circular planar piston sources in the most of cases. But this simplification cannot be applied to partially damaged transducer which has lost their symmetry in performance, even not in appearance. Unfortunately there has been no reliable practical model which can be used for the calibration of partially damaged transducers. Here a pulse-echo testing model for partially damaged ultrasonic transducers was developed with experimental verification. The experimental responses agree very well with the theoretical prediction. So we expect that this model can be served as a theoretical reference standards for transducer calibration.

  • PDF

Waveform characteristics of ultrasonic wave generated from CNT/PDMS composite (CNT/PDMS 복합체로부터 방사된 초음파의 파형 특성)

  • Kim, Gisuk;Kim, Moojoon;Ha, Kanglyeol;Lee, Jooho;Paeng, Dong-Guk;Choi, Min Joo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.4
    • /
    • pp.459-466
    • /
    • 2019
  • When a laser pulse is irradiated on a CNT (Carbon Nanotube) and PDMS (Poly dimethylsiloxane) composite coated on a transparent PMMA (Poly methyl methacrylate) substrate, a strong ultrasonic wave is generated due to the thermoelastic effect. In this paper, the thermoacoustic theory related to the wave generation by the CNT/PDMS composite was established. The waveforms of ultrasonic waves when a laser pulse having a Gaussian waveform is irradiated on the composite with a thickness of $20{\mu}m$ were numerically simulated. From the results, it was confirmed that ultrasonic shock waves can be generated from the CNT/PDMS composite and the waveforms are changed little even if the physical properties of the composite are changed by ${\pm}20%$. It was found that the peak positive and negative pressures increase as the thermal expansion coefficient increases, or as density, heat capacity and sound speed decreased. However, those changes were not so sensitive with thermal conductivity. In addition, the physical properties of the CNT/PDMS composite fabricated in this study were estimated from the comparison of the measurement and simulation results.

Development of a Pulse Wave Velocity Measurement System and Assessment of the System Reproducibility for the Diagnosis of Arteriosclerosis (동맥경화 진단을 위한 맥파전달속도 측정시스템 개발 및 재현성 평가)

  • Lee, Nak-B.;Im, Jae-J.;Park, Young-B.;Jeon, Young-J.
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.9 no.1
    • /
    • pp.112-124
    • /
    • 2005
  • Background: PWV is determined by dividing the distance by the time taken for the pulses traveling between two measuring sites, used as a marker of arterial stiffness and an important indicator for cardiovascular disease. Methods: A PWV measurement system, which offers a non-invasive, simple method of measurement, and simultaneous recording of six signlas(ECG, PCG and four pulse waves from carotid, femoral, radial and dorsalis pedis arteries) was developed. Seventeen healthy subjects with a mean age of 33 years(22 to 52) without any cardiovascular disease were participated for the experiment. Two observers(A and B) performed two consecutive measurements from the same subject in a random order. For the evaluation of stability and accuracy of the PWV measurement system, reproducibility of PWV from between-observer were also evaluated. Results: PWV $values(Mean{\pm}SD)$ measured by A were $7.07{\pm}1.48m/s$, $8.43{\pm}1.14m/s$ , $8.09{\pm}0.98m/s$ for aorta, arm, and leg, respectively. The values obtained from B were $6.76{\pm}1.00m/s$, $7.97{\pm}0.80m/s$, and $7.97{\pm}0.72m/s$ for aorta, arm, and leg, respectively. Between-observer $differences(mean{\pm}SEM)$ from the aorta, arm and leg were $0.14{\pm}0.15m/s$, $0.18{\pm}0.10m/s$ and $0.07{\pm}0.10m/s$. Reproducibility coefficients(2SD) from the aorta, arm, and leg were 0.62m/s, 0.84m/s and 0.86m/s. Correlation coefficients were significantly higher in aortic PWV, 0.93, compared to the coefficients for arm and leg. Coefficient of variance which reflects the reproducibility of the system ranged from $4.4{\sim}5.8%$ in all regional PWV. , Conclusion: Reproducibility of PWV in the study shows that the developed system has reliable and reproducible characteristics. The PWV measurement system used for the study offers comfortable and simple operation and provides accurate analysis and results with high reproducibility. Results of the PWV measurement system could contribute to various clinical applications in the future.

  • PDF

Electromagnetic Characteristics of Dielectric Barrier Discharge Plasma Based on Fluid Dynamical Modeling (유체역학에 바탕한 플라즈마 모델링을 통한 유전체 장벽 방전 플라즈마의 전파 특성 해석)

  • Kim, Yu-Na;Oh, Il-Young;Hong, Yong-Jun;Yook, Jong-Gwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.3
    • /
    • pp.331-336
    • /
    • 2013
  • In this paper, plasma modeling is achieved using fluid dynamics, thereby electron density is derived. The way proposes the key to overcoming the limitations of conventional researches which adopt simplified plasma model. The result is coupled with Maxwell-Boltzmann system in order to calculate scattering waves in various incident angle. The first part is dedicated to perform plasma modeling in dielectric barrier discharge(DBD) structure. Suzen-Huang model is adopted among various models due to the fact that it uses time independent variables to calculated potential and electron distribution in static system. The second part deals with finite difference time domain(FDTD) scheme which computes the scattered waves when the modulated Gaussian pulse is incident. Founded on it, radar cross section(RCS) is observed. Consequently, RCS is decreased by 1~2 dB with DBD plasma. The result is analogous to the RCS measurement in other researches.