• 제목/요약/키워드: Pulse Waves

검색결과 306건 처리시간 0.024초

안테나를 이용한 부분방전의 진단기병에 관한 연구 (The Diagnosis technique of Partial Discharges using Antenna)

  • 김영노;김재철;전영재;서인철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.217-219
    • /
    • 2001
  • This paper presents new diagnosis technique for detecting a partial discharge(PD) using antenna. The wavelet transform is applied for the analysis of PD pulse signal because it is difficult to identify PD signal using electromagnetic waves detected by antenna. The capabilities of the proposed diagnosis methodology for detecting PD signal is verified on experiment in laboratory.

  • PDF

A Comparative Study of Methods of Measurement of Peripheral Pulse Waveform

  • Kang, Hee-Jung;Lee, Yong-Heum;Kim, Kyung-Chul;Han, Chang-Ho
    • 대한한의학회지
    • /
    • 제30권3호
    • /
    • pp.98-105
    • /
    • 2009
  • Objective: Increased aortic and carotid arterial augmentation index (AI) is associated with the risk of cardiovascular disease. The most widely used approach for determining central arterial AI is by calculating the aortic pressure waveform from radial arterial waveforms using a transfer function. But how the change of waveform by applied pressure and the pattern of the change rely on subject's characteristics has not been recognized. In this study, we use a new method for measuring radial waveform and observe the change of waveform and the deviation of radial AI in the same position by applied pressure. Method: Forty-six non-patient volunteers (31 men and 15 women, age range 21-58 years) were enrolled for this study. Informed consent in a form approved by the institutional review board was obtained in all subjects. Blood pressure was measured on the left upper arm using an oscillometric method, radial pressure waves were recorded with the use of an improved automated tonometry device. DMP-3000(DAEYOMEDI Co., Ltd. Ansan, Korea) has robotics mechanism to scan and trace automatically. For each subject, we performed the procedure 5 times for each applied pressure level. We could thus obtain 5 different radial pulse waveforms for the same person's same position at different applied pressures. All these processes were repeated twice for test reproducibility. Result: Aortic AI, peripheral AI and radial AI were higher in women than in men (P<0.01), radial AI strongly correlated with aortic AI, and radial AI was consistently approximately 39% higher than aortic AI. Relationship between representative radial AI of DMP-3000 and peripheral AI of SphygmoCor had strongly correlation. And there were three patterns in change of pulse waveform. Conclusion: In this study, it is revealed the new device was sufficient to measure how radial AI and radial waveform from the same person at the same time change under applied pressure and it had inverse-proportion to applied pressure.

  • PDF

표면화학 반응을 통한 Laser-Ablated 알루미늄의 Detonation 현상 연구 (Detonation Initiation via Surface Chemical Reaction of Laser-Ablated Aluminum Sample)

  • 김창환;여재익
    • 대한기계학회논문집B
    • /
    • 제36권2호
    • /
    • pp.197-204
    • /
    • 2012
  • 본 논문에서는 공기 중에서 높은 레이저 복사 조도에 따른 효과에 의해 발생되는 금속 플라즈마의 발달 과정에 대하여 레이저 펄스가 끝나는 이후로 쉐도우그래프(Shadowgraph) 가시화 방법을 이용하여 현상을 연구하였다. 따라서 레이저에 의한 데토네이션의 발생과 이를 일으키는 연소 과정 대한 연구가 진행되었다. 본 논문의 가장 중요한 점들은 높은 레이저 에너지에 의해 삭마 된 기체 상태의 알루미늄과 공기로부터의 산소와의 화학 반응의 진행을 관측했을 뿐만 아니라, 화학 반응 최종 산화물을 X선 회절 분석법(X-Ray Diffraction)을 통해 관측한 것이다. 그리고 레이저를 통해 유도된 화학적 반응 파와 공기 중에서의 알루미늄 분진 폭발의 데토네이션과의 양적인 평가를 유도하였다. 이러한 연구는 덩어리 상태의 금속 샘플에서 공기 중의 산소를 이용하여 데토네이션을 발생시키는 새로운 방법을 제시할 것으로 여겨진다.

탄소 재료를 사용한 전자파 차폐 무기계 도료 개발에 관한 실험적 연구 (Experimental Study on the Development of Electromagnetic Pulse Shielding Inorganic Paint Using Carbon Materials)

  • 장경필;송태협
    • 한국건설순환자원학회논문집
    • /
    • 제11권3호
    • /
    • pp.234-243
    • /
    • 2023
  • 전자파(EMP)는 고출력 전자파의 총칭으로 핵무기에서 발생하는 EMP, 비핵 EMP, 자연현상에 의해 발생하는 EMP로 분류된다. 전자파는 통신기기, 휴대폰, 컴퓨터, TV, 교통수단 등 전자기적 요소를 지닌 모든 전자장치에 치명적인 손상을 줄 수 있는 수단이다. 본 연구에서는 탄소 재료를 이용한 EMP 차폐 무기 도료 개발을 위해 탄소 재료의 종류와 함량에 따른 도료의 EMP 차폐성능 평가를 수행하였다. 도료 제조에 사용된 원재료들의 상용성 및 분산성 향상을 분석하기 위해 약 27종의 배합으로 총 2회에 걸쳐 실험을 진행하였고, 전기저항 측정법을 이용하여 EMP 차폐 효과를 평가하였다. 본 연구를 통해 개발된 EMP 차폐 도료를 차폐 콘크리트에 적용한 결과 약 25 dB에서 최대 40 dB까지 차폐성능이 향상되는 것을 확인하였다.

1-Benzyl-4-Iodomethyl-2-Azetidinone의 합성과 Iodo기에 대한 전기화학적 환원반응 (Synthesis of 1-Benzyl-4-Iodomethyl-2-Azetidinone and Electrochemical Reduction on the Iodo Group)

  • 김일광;이영행;이채호;채규윤;김윤근
    • 대한화학회지
    • /
    • 제35권1호
    • /
    • pp.70-77
    • /
    • 1991
  • 1-Benzyl-4-iodomethyl-2-azetidinone(BIMA)을 합성하여 iodomethyl기에 대한 전기화학적 환원을 direct current, differential pulse polarography, cyclic voltammetry 그리고 controlled potential coulometry 방법으로 연구하였다. BIMA의 환원과정은 1단계(-1.35 volts vs. Ag-AgCl)에서 완전비가역과 2전자이동후에 양성자가 첨가되는 EEC 반응기구로 진행되었으며 1-benzyl-4-methyl-2-azetidinone이 생성되었다. 양이온 계면활성제(cetyltrimethylammonium bromide)의 농도가 진하여질수록 양전위 이동이 있었으나 음이온 계면활성제(sodium lauryl sulfate)의 경우에는 2단계로 세분화되는 현상이 나타났다. pH변화에 따른 전극환원과정과 생성물 분석의 결과를 바탕으로 전기화학적 반응기구를 제안하였다.

  • PDF

Ultrasonic characterization of exhumed cast iron water pipes

  • Groves, Paul;Cascante, Giovanni;Knight, Mark
    • Smart Structures and Systems
    • /
    • 제7권4호
    • /
    • pp.241-262
    • /
    • 2011
  • Cast iron pipe has been used as a water distribution technology in North America since the early nineteenth century. The first cast iron pipes were made of grey cast iron which was succeeded by ductile iron as a pipe material in the 1940s. These different iron alloys have significantly different microstructures which give rise to distinct mechanical properties. Insight into the non-destructive structural condition assessment of aging pipes can be advantageous in developing mitigation strategies for pipe failures. This paper examines the relationship between the small-strain and large-strain properties of exhumed cast iron water pipes. Nondestructive and destructive testing programs were performed on eight pipes varying in age from 40 to 130 years. The experimental program included microstructure evaluation and ultrasonic, tensile, and flexural testing. New applications of frequency domain analysis techniques including Fourier and wavelet transforms of ultrasonic pulse velocity measurements are presented. A low correlation between wave propagation and large-strain measurements was observed. However, the wave velocities were consistently different between ductile and grey cast iron pipes (14% to 18% difference); the ductile iron pipes showed the smaller variation in wave velocities. Thus, the variation of elastic properties for ductile iron was not enough to define a linear correlation because all the measurements were practically concentrated in single cluster of points. The cross-sectional areas of the specimens tested varied as a result of minor manufacturing defects and levels of corrosion. These variations affect the large strain testing results; but, surface defects have limited effect on wave velocities and may also contribute to the low correlations observed. Lamb waves are typically not considered in the evaluation of ultrasonic pulse velocity. However, Lamb waves were found to contribute significantly to the frequency content of the ultrasonic signals possibly resulting in the poor correlations observed. Therefore, correlations between wave velocities and large strain properties obtained using specimens manufactured in the laboratory must be used with caution in the condition assessment of aged water pipes especially for grey cast iron pipes.

송.수신 분리형 초음파 거리 측정기 개발 (A Development of Ultrasonic Based Distance Meter Through Detachment of Receiving and Transmitting Capacitive Ultrasonic Transducer)

  • 김정훈;정정화
    • 전자공학회논문지SC
    • /
    • 제43권3호
    • /
    • pp.41-50
    • /
    • 2006
  • 본 논문에서는 30cm 이하의 단거리의 물체를 인식하기 어려운 초음파 센서의 특성을 개선하기 위하여 2개의 커패시터 초음파 트랜스듀서를 사용하여 송신과 수신을 분리함으로써 단거리 측정과 무선에 의한 원거리 정밀 측정이 가능한 시스템을 제안한다. 이 시스템은 무선으로 송수신 하도록 설계되었으며 무선으로 연결된 송신, 수신의 동기를 일치시켜야 한다. 트리거 펄스는 10Hz이며, 이 주파수는 무선 모듈에서 데이터를 전송하기에 매우 낮은 주파수이므로 캐리어 신호와 트리거 신호를 합성 및 분리하는 방법을 제안한다. 개발한 시스템은 범용 마이크로프로세서인 8051을 이용하여 구현하였으며, 그 유용성을 입증하기 위한 실험 결과 송신 센서와 수신 센서를 마주보게 배치하여 송신 초음파가 수신 초음파 센서로 직접 보낼 때 센서간의 거리가 0mm부터 측정이 가능하며 송신 센서에서 초음파가 송신되고 물체에 반사한 후 수신 센서로 수신되었을 때 7cm부터 물체를 감지하였다.

맥율용 3채널 생체신호 계측시스템 개발 (Development of 3 Channel Biomedical Signal Measurement System for Mac-yule)

  • 변미경;김현준;장준근;한상휘;허웅
    • 전기전자학회논문지
    • /
    • 제11권1호통권20호
    • /
    • pp.24-29
    • /
    • 2007
  • 본 연구에서 심리적으로 안정된 상태에서 맥율을 측정할 수 있는 장치를 개발하였다. 개발된 시스템은 뇌파, 호흡파, 맥동파를 검출하는 하드웨어장치와 이들 신호를 획득하고 처리하는 소프트웨어로 구성하였다. 뇌파는 전두부에서 쌍극형으로 유도하였고, 호흡은 서미스터 브리지를 이용하여 구성된 변환기를 사용하여 비강 전부에서 유도하였으며 맥동파는 귀볼에서 유도한 용적맥파를 사용하였다. 피검자의 심리적 안정된 상태의 판정은 뇌파의 스펙트럼을 이용하였다. 맥율의 결정은 원전에 따라 1호흡 당 맥동수를 사용하였다. 개발된 장치를 사용하여 맥율검출 실험을 한 결과, 뇌파의 주파수 대역별 구분, 안정된 호흡신호의 검출과 이득 조절이 되는 용적맥파의 검출이 실시간으로 가능하였다. 그리고 검출된 신호로부터 맥율을 검출할 수 있었다.

  • PDF

촌관척(寸關尺)부의 검측한 부정맥과 electrocardiographic 결과와의 한의학적 검토 (The oriental medical study about the arrythmia detected on the radial pulses and the result of ECG)

  • 류희영;허은정;김지현;윤정미;전성하
    • 대한한의정보학회지
    • /
    • 제14권1호
    • /
    • pp.81-106
    • /
    • 2008
  • The ECG which used for this paper, is analysis result from alogrisms of arrythmia, and we have studied that how we could certain Cold(寒 )type or Heat(熱) type and that Deficiency(虛) type or Excess(實)type of organs from various special diseases, and we obtained like these results. 1. we depend on our examination about Pulse(脈) because we can't discriminate arrythmia using EKG analysis instruments. 2. We obtained that Cold(寒) type diseases had wave that prolonged above normal baseline and ST wave which had downward aptitude. 3. We obtained that Heat(熱) type diseases had the fibrillation which had shortend wave that compare to normal and had downward aptitude or negative aptitude. 4. We obtained that Respiratory system (肺) diseases had wave that is within normal or is short of normal range and had much fluctuation in potential difference or trans on P wave. 5. The character of EKG which presented about diseases of gastric systems is prolonged above narmal range of wave, and the EKG had represented mixed wave with Heat(熱) type when accompany inflammatory in gastric system. 6. The wave of Blood Stasis(瘀血) type had upward aptitude of QRS wave, and the wave of anemia or blood loss type(少血 ) had downward aptitude of QRS wave, the wave which had both Cold(寒) and Heat (熱) represented mixed waves. 7. The Knotted Pulse(結脈) and Intermittent Pulse(代脈) is corresponded with sinus brady cardia, and the Swift Pulsle(疾脈) is corresponded with fibrillation. 8. We pay attention to the relations of formations about pressures pulse from formations of EMD( electromechanical dissociation ). From these results, we will have to study about EKG which using in tests of change of Parkinsons disease.

  • PDF