한방용(韓方用) 맥파 검출시스템 (Radial Pulse Wave Detection system for the Korean Medicine)

  • 이호재;김진우;김흥오;박영배;허웅
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1991년도 추계학술대회
    • /
    • pp.66-69
    • /
    • 1991
  • This paper describes a design of transducer for non-invasively detecting pressure radial pulse wave in aterial system and a recording system that for the studing the aterial pulse diagnosis of korean traditional medicine. The mechanism of transducer is composed of sensing mechanism, pressure sensor, conditioning amplifier. The variation of radial pulse pressure in the sensing mechanism is converted to the electric signal by piezo-resistive pressure sensor and it converted to the digital signal after preprocessing via A/D converter. The converted signals inputed to the computer as data files and then it display to the monitor for waveform watching and this datas can be used as the aterial pulse diagnosis data. This system effectively detect non-differential radial pulse wave and we conside that if analizing the recorded radial pulse wave, compared each other, it can be helpful in quantify radial pulse wave diagonosis of the Korean traditional medicine.

  • PDF

영구자석과 홀소자가 구비된 맥진기를 이용한 경동맥과 요골동맥의 맥진파형과 맥파전달속도 분석 (Analysis of Pulse Waveform and Pulse Wave Velocity of Carotid Artery and Radial Artery by Using Clip-type Pulsimeter Equipped with Permanent and Hall Device)

  • 김동영;이상석;현석산;이진규
    • 한국자기학회지
    • /
    • 제24권5호
    • /
    • pp.146-151
    • /
    • 2014
  • 영구자석과 홀소자로 구비된 집게형 맥진기를 이용하여 목 부위의 경추동맥의 맥진파형과 손목 부위의 요골동맥 맥진파형을 각각 측정하였다. 두 개의 맥진파형을 비교하여 얻은 맥파전달시간과 맥파전달속도를 분석하였다. 맥파전달속도는 기존의 방식으로 측정한 값과 유사한 약 8.5 m/s으로 나타났다. 재현성과 신뢰성이 있는 한방의료기기인 집게형 맥진기로 얻은 맥파전달속도를 기준하여 동맥경화도를 예측할 수 있음을 제시하였다.

맥진기를 이용한 좌우 맥파 및 혈관 특성 연구 (A Research of characteristics of left/right pulse wave and blood vessel using Korean medicine pulse diagnosis)

  • 강진호;이한별;김기왕;권정남;이병렬
    • 대한한의학회지
    • /
    • 제35권3호
    • /
    • pp.155-165
    • /
    • 2014
  • Objectives: The pulse diagnosis to identify the symptoms has been considered important in Korean medicine. The position and character of disease would be confirmed by pulse diagnosis of left and right radial artery. This paper is to analyze the characteristics and differences of left and right blood vessels. Methods: In this study, left and right radial artery and dorsalis pedis artery was measured and analyzed by using condenser typed pulse analyzer. Commercially available pulse analyzer was used to measure the radial artery. The pulse wave was measured in 20 laboratory healthy men and women. The blood vessel aging degree and index of augmentation of blood vessel was obtained from the measured pulse wave graph and the characteristics and differences of the left and right blood vessel was analyzed. Results: The significant difference of pulse transit time between the right handed and non-right handed was not found. The correlation of radial artery and dorsalis pedis artery had no significant difference. By obtaining the blood vessel aging index (AGI) and augmentation index (AI) of blood vessel at the left and right radial artery, the significant difference between right handed and non-right handed was not found. Conclusions: The result of this study would help to explain the characteristic of blood vessel with respect to the left and right handed. We suggest that research of pulse wave of the left and right blood vessel using pulse analyzer should be needed in further study.

인영.촌구 대비법을 이용한 맥 진단 시스템 구현 (Implementation of Radial Pulse Diagnosis System using Inyoung-Cheongu Comparison Method)

  • 이호재;박영배;허웅
    • 대한의용생체공학회:의공학회지
    • /
    • 제14권1호
    • /
    • pp.73-80
    • /
    • 1993
  • This paper describes the implementation of a computerized radial pulse diagnosis by Elds of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diag nosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed It. Then, we have got the characteristic parameters of radial pulse wave and also quantified thats according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial Pulse diagnosis system and then we confirmed the PossibiliLy for realization of automatic radial Pulse diagnosis in korean traditional medicine.

  • PDF

촌관척(寸關尺)부의 검측한 부정맥과 Electrocardiographic 결과의 한의학적 검토 (The Oriental Medical Study about the Arrythmia Detected on the Radial Pulses and the Result of ECG.)

  • 류희영;허은정;김지현;윤정미;전성하
    • 동의신경정신과학회지
    • /
    • 제19권2호
    • /
    • pp.165-193
    • /
    • 2008
  • Objective: The ECG which used for this paper, is analysis result from alogrisms of arrythmia, and we have studied that how we could certain Cold(寒)type or Heat(熱) type and that Deficiency(虛) type or Excess(實)type of organs from various special diseases, and we obtained like these results. Method & Conclusion: 1. we depend on our examination about Pulse(脈) because we can't discriminate arrythmia using ECG analysis instruments. 2. We obtained that Cold(寒) type diseases had wave that prolonged above normal baseline and ST wave which had downward aptitude. 3. We obtained that Heat(熱) type diseases had the fibrillation which had shortend wave that compare to normal and had downward aptitude or negative aptitude. 4. We obtained that Respiratory system (肺) diseases had wave that is within normal or is short of normal range and had much fluctuation in potential difference or trans on P wave. 5. The character of EKG which presented about diseases of gastric systems is prolonged above narmal range of wave, and the ECG had represented mixed wave with Heat(熱) type when accompany inflammatory in gastric system. 6. The wave of Blood Stasis(瘀血) type had upward aptitude of QRS wave, and the wave of anemia or blood loss type(少血) had downward aptitude of QRS wave, the wave which had both Cold(寒)) and Heat (熱) represented mixed waves. 7. The Knotted Pulse(結脈) and Intermittent Pulse(代脈)is corresponded with sinus brady cardia, and the Swift Pulsle(疾脈) is corresponded with fibrillation. 8. We pay attention to the relations of formations about pressures pulse from formations of EMD( electromechanical dissociation ). Result : From these results, we will have to study about ECG which using in tests of change of Parkinsons disease.

  • PDF

요골동맥 직경 변화에 따른 맥파 측정 시스템 개발 (Development of an Measuring System for Pulse Wave Corresponding to Different Radial Artery Diameters Caused by Indentation)

  • 이전;우영재;전영주;이유정;김종열
    • 전기학회논문지
    • /
    • 제57권12호
    • /
    • pp.2351-2357
    • /
    • 2008
  • Noninvasive radial artery pulse wave has been widely used not only for the pulse wave analysis(PWA) itself but also for assessment of arterial stiffness with estimated aortic pulse wave from peripheral pulse wave. However, it has been found that the deformation of pulse shape can be caused readily by changing measuring position, indentation pressure, and so on. So, in this study, we have developed a system which can measure radial pulse wave and skin displacement simultaneously while the indentation body goes down to occlude subject's radial artery. This system can be divided into a measuring apparatus part, an indentation control hardware part, a data acquisition part and a control and computation part. And, the measuring apparatus consists of an arm-rest, a step motor, an indentation body, a laser displacement sensor(LK-G30, Keyence Co.) and pulse wave sensor. Under load-free condition and radial artery loaded condition, the evaluation of developed system has been performed. From these results, we can conclude: 1) The developed system can control the indentation body quantitatively and the adopted laser displacement sensor shows linear output characteristic even with skin as a reflector. 2) This system can measure the pulse wave and the displacement of indentation body, that is, skin displacement simultaneously at each specific level of indentation body. 3) This system can provide the number of motor steps used to get down the indentation body, the measured skin displacement, the calculated indentation pressure, the calculated pulse pressure and the pulse waveform as well as the information generated by combining these with each others. 4) This system can reveal the relationship between the morphological changes of pulse wave and the estimated displacement of radial artery wall by indentation. Consequently, the developed system can furnish more abundant information on radial artery than previous diagnosis systems based on tonometric measurement. In further study, we expect to setup the standard measuring process and to concrete the algorithm for the estimation of radial artery's diameter and of displacement of radial artery's wall. Furthermore, with well designed clinical studies, we hope to turn out the usefulness of developed system in the field of cardiovascular system evaluation.

맥파 측정 센서와 전도성 섬유, 임베디드 시스템 기반의 웨어러블 센서 글러브 구현 (Implementation of Wearable Sensor Glove using Pulse-wave Sensor, Conducting Fabric and Embedded System)

  • 이영범;이병우;이명호
    • 제어로봇시스템학회논문지
    • /
    • 제13권3호
    • /
    • pp.205-209
    • /
    • 2007
  • Today, there are research trends about the wearable sensor device that measures various bio-signals and provides healthcare services to user using e-Health technology. This study describes the wearable sensor glove using pulse-wave sensor, conducting fabric and embedded system. This wearable sensor glove is based on the pulse-wave measurement system which is able to measure the pulse wave signal in much use of oriental medicine on the basis of a research trend of e-Health system.

식사가 정상인의 맥에 미치는 영향 분석 (Effect of Taking Meal on Pulse Diagnosis in Healthy Subjects)

  • 이유정;이전;이혜정;최은지;김종열
    • 동의생리병리학회지
    • /
    • 제21권6호
    • /
    • pp.1670-1675
    • /
    • 2007
  • The pulse diagnosis studies reported to date has mainly been performed to clinically reveal the pulse wave characteristics according to the specific diseases, whereas no attempts have been made to study the effects on the pulse wave characteristics of the daily activities such as taking meals, exercise, and sleep, etc. This work reports the effect of feeding stimulus on the healthy subjects on the pulse wave pattern which has quantitatively been analyzed using the objective model for the pulse diagnosis in oriental medicine. The pulse waves right before/after the meal and 30 minutes after the meal were measured using the pulse analyzing equipment (3D-Mac, Daeyo Medi, Korea) and at the same time oriental medicine doctors' diagnoses were given. The pulse parameters obtained from the equipment and clinical records on the subjects were statistically processed and the variables showing statistically significant differences were analyzed. The results indicate that the pulse pressure, the pulse rate, and the respiratory rate increase while the blood pressure decreases after the meal. For the floating/sinking and the deficient/excess coefficients characterizing the pulse states described in the oriental medicine, the floating/sinking coefficients were observed to decrease whereas the deficiency/excess coefficients increase after the meal. The results indicates that besides the standard bio-indicators like blood pressure and respiratory rate, etc., the pulse wave characterization in terms of the pulse classifications in the oriental medicine using the floating/sinking, deficient/excess pulse states provide an important piece of biomedical information.

Immobilization of Heparin onto the Polyurethane

  • Cho, Chong-Su;Kim, Sung-Wan
    • 대한의용생체공학회:의공학회지
    • /
    • 제7권2호
    • /
    • pp.147-150
    • /
    • 1986
  • This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine.

  • PDF

심혈관계 시뮬레이터를 이용한 맥파 반사지점 추정방법들의 비교 (Evaluation of methods for estimating the pulse reflection site with cardiovascular simulator)

  • 이주연;신상훈
    • 대한한의진단학회지
    • /
    • 제19권1호
    • /
    • pp.47-54
    • /
    • 2015
  • Objective Wave reflection is an important factor that determines the shape of the pulse wave. The purpose of this study is to compare the conventional method used for estimating the reflection site of pulse with a cardiovascular simulator. Methods: In this study, cardiovascular simulator with one elastic tube was used. The pressure and flow was measured simultaneously at three different points. The measured data were used to the conventional methods to estimate the pulse wave reflection site. The results were compared with the known length which were the distances from the measured points to the end of tube. Results & Conclusions: There is a significant error with the time domain method. While, the reflection site with the frequency domain method was similar to the actual reflection site.