• 제목/요약/키워드: Pulse Point

검색결과 513건 처리시간 0.023초

인영촌구비교맥진(人迎寸口比較脈診)에 관한 연구 (A Study on Comparative Pulse Diagnosis of Renying Pulse(人迎脈) and Cunkou Pulse(寸口脈))

  • 윤창열
    • 대한한의학원전학회지
    • /
    • 제32권4호
    • /
    • pp.35-46
    • /
    • 2019
  • Objectives : While Comparative Pulse Diagnosis of Renying pulse(人迎脈) and Cunkou pulse(寸口脈) is one of the three major pulse diagnostic methods in "Huangdineijing" along with Three Positions and Nine Indicators Pulse Diagnosis(三部九候脈診法) and Cunkou Pulse Diagnosis(寸口脈診法), it has died out in later periods. This study aims to examine this lost method. Methods : Annotations of "Huangdineijing" were examined along with descriptions of the author's own experience. Results & Conclusions : Renying is the Renying(人迎) point from the Stomach Channel(ST), while Cunkou is the Taiyuan(太淵) point from the Lung Channel(LU). These two points are compared in order to determine the deficiency and excess of the Zangfu(臟腑). Normal pulses(平脈) are Soft(軟脈) or Moderate(緩脈), while Stirred pulses(躁脈) are Stringy(弦脈), Tight(緊脈), Slippery(滑脈) or Long(長脈). If the Renying is once active where Shaoyang pulse is active, purge the Gallbladder and supplement the Liver. If there is Stirred pulse, purge the Triple Burner and supplement the Pericardium. If the Renying is twice active where Taiyang pulse is active, purge the Bladder and supplement the Kidney. If there is Stirred pulse, purge the Small Intestine and supplement the Heart. If the Renying is three times active, where Yangming pulse is active, purge the Stomach and supplement the Spleen. If there is Stirred pulse, purge the Large Intestine and supplement the Lung. If the Cunkou is once active where the Jueyin pulse is active, purge the Liver and supplement the Gallbladder. If there is Stirred pulse, purge the Pericardium and supplement the Triple Energizer. If the Cunkou is twice active where the Shaoyin pulse is active, purge the Kidney and supplement the Bladder. If there is stirred pulse, purge the Heart and supplement the Small Intestine. If the Cunkou is three times active where the Taiyin pulse is active, purge the Stomach and supplement the Spleen. If there is Stirred pulse, purge the Lung and supplement the Large Intestine.

웨이브렛 변환을 이용한 심전도와 맥파의 특징점 인식 (Recognition of Feature Points in ECG and Human Pulse using Wavelet Transform)

  • 길세기;신동범;이응혁;민홍기;홍승홍
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제55권2호
    • /
    • pp.75-81
    • /
    • 2006
  • The purpose of this paper is to recognize the feature points of ECG and human pulse -which signal shows the electric and physical characteristics of heart respectively- using wavelet transform. Wavelet transform is proper method to analyze a signal in time-frequency domain. In the process of wavelet decomposition and reconstruction of ECG and human pulse signal, we removed the noises of signal and recognized the feature points of signal using some of decomposed component of signal. We obtained the result of recognition rate that is estimated about 95.45$\%$ in case of QRS complex, 98.08$\%$ in case of S point and P point and 92.81$\%$ in case of C point. And we computed diagnosis parameters such as RRI, U-time and E-time.

A New DPWM Method to Suppress the Low Frequency Oscillation of the Neutral-Point Voltage for NPC Three-Level Inverters

  • Lyu, Jianguo;Hu, Wenbin;Wu, Fuyun;Yao, Kai;Wu, Junji
    • Journal of Power Electronics
    • /
    • 제15권5호
    • /
    • pp.1207-1216
    • /
    • 2015
  • In order to suppress the low frequency oscillation of the neutral-point voltage for three-level inverters, this paper proposes a new discontinuous pulse width modulation (DPWM) control method. The conventional sinusoidal pulse width modulation (SPWM) control has no effect on balancing the neutral-point voltage. Based on the basic control principle of DPWM, the relationship between the reference space voltage vector and the neutral-point current is analyzed. The proposed method suppresses the low frequency oscillation of the neutral-point voltage by keeping the switches of a certain phase no switching in one carrier cycle. So the operating time of the positive and negative small vectors is equal. Comparing with the conventional SPWM control method, the proposed DPWM control method suppresses the low frequency oscillation of the neutral-point voltage, decreases the output waveform harmonics, and increases both the output waveform quality and the system efficiency. An experiment has been realized by a neutral-point clamped (NPC) three-level inverter prototype based on STM32F407-CPLD. The experimental results verify the correctness of the theoretical analysis and the effectiveness of the proposed DPWM method.

맥진(脈診)의 사상의학적(四象醫學的) 고찰(考察) (The Sasang Constitutional Thought of Pulse Diagnosis)

  • 김인태;이수경;이의주;고병희;송일병
    • 사상체질의학회지
    • /
    • 제15권3호
    • /
    • pp.22-32
    • /
    • 2003
  • The pulse diagnosis is the basic method of oriental medicine diagnosis. But in sasang constitutional medicine, it is said that it's not a major diagnotic method. But we don't have any sasang constitutional study of the pulse diagnosis. So I made this study by research of changing concept of the pulse diagnosis in chinese medical history and Dongyi Suse Bowon (longevity and life preservation in oriental medicine). The conclusion as follows. 1. There were many kinds of the pulse diagnosis in the ancient times, it has developed to simple and effective diagnotic method. Simple and effective is the major point of medical development, the 24 pulse is abridged to Floating Pulse(浮), Deep Pulse(沈), Slow Pulse(遲), Rapid Pulse(數) 2. The latter term of Chosun, the practical study was developed. In the view of the practical study, the pulse diagnosis has a lot of cricical point. Jung Yak-Yong, in his writing Mak Lon(脈論), criticize the pulse diagnosis. 3. In the sasang constitutional medicine, the constitutional diagnosis is very important. The methods of the constitutional diagnosis are three, the way of mind and greed, knowledge and deed, external figure and physical traits. But the pulse diagnosis is one of the way of external figure and physical traits, so we can't diagnose the exact constitution by the pulse diagnosis. 4. Dong-mu conclude that the pulse diagnosis is just the diagnostic way of symptom. But in the clinical situation, the ordinary symptoms are more important than the pulse diagnosis, because it is useful to know the condition of the ingestive food metabolism and the Qi-yack metabolism

  • PDF

맥파전달속도 계산을 위한 특징점 검출 알고리즘 개발 (Development of a Characteristic Point Detection Algorithm for the Calculation of Pulse Wave Velocity)

  • 이낙범;임재중
    • 전기학회논문지
    • /
    • 제57권5호
    • /
    • pp.902-907
    • /
    • 2008
  • Shape of the pulse waveform is affected by the visco-elasticity characteristics of the arterial wall and the reflection waves generated at the bifurcations of arterial branches. This study was designed to improve the accuracy for the extraction of pulse wave features, then proved the superiority of the developed algorithm by clinical evaluation. Upstroke point of the pulse wave was used as an extraction feature since it is minimally affected by the waveform variation. R-peak of the ECG was used as a reference to decide the minimum level, then intersection of the least squares of regression line was used as an upstroke point. Developed algorithm was compared with the existing minimum value detection algorithm and tangent-intersection algorithm using data obtained from 102 subjects. Developed algorithm showed the least standard deviation of $0.29{\sim}0.44\;m/s$ compared with that of the existing algorithms, $0.91{\sim}3.66\;m/s$. Moreover, the rate of standard deviation of more than 1.00m/s for the PWV values reduced with the range of $29.0{\sim}42.4%$, which proved the superiority of the newly developed algorithm.

맥파의 특징점 인식과 파형의 분류에 관한 연구 (The Study on the Feature Point Recognition and Classification of Radial Pulse)

  • 길세기;김낙환;이상민;박승환;홍승홍
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 하계종합학술대회 논문집
    • /
    • pp.555-558
    • /
    • 1999
  • In this paper, Ire present the result of feature points recognition and classification of radial pulse by the shape of pulse wave. The recognition algorithm use the method which runs in parallel with both the data of ECG and differential pulse simultaneously to recognize the feature points. Also we specified 3-time elements of pulse wave as main parameters for diagnosis and measured them by execution of algorithm. then we classify the shape of radial pulse by existence and position of feature points.

  • PDF

Simplified PWM Strategy for Neutral-Point-Clamped (NPC) Three-Level Converter

  • Ye, Zongbin;Xu, Yiming;Li, Fei;Deng, Xianming;Zhang, Yuanzheng
    • Journal of Power Electronics
    • /
    • 제14권3호
    • /
    • pp.519-530
    • /
    • 2014
  • A novel simplified pulse width modulation(PWM) strategy for neutral point clamped (NPC) three-level converter is proposed in this paper.The direct output voltage modulation is applied to reduce the calculation time. Based on this strategy, several optimized control methods are proposed. The neutral point potential balancing algorithm is discussed and a fine neutral point potential balancing scheme is introduced. Moreover, the minimum pulse width compensation and switching losses reduction can be easily achieved using this modulation strategy. This strategy also gains good results even with the unequal DC link capacitor. The modulation principle is studied in detail and the validity of this simplified PWM strategy is experimentally verified in this paper. The experiment results indicated that the proposed PWM strategy has excellent performance, and the neutral point potential can be balanced well with unequal DC link captaincies.

IMT2000을 위한 혼성마이크로 동력원 개발에 관한 연구 (A Study on the Development of Hybrid Micro Power Sources for the IMT2000)

  • 김일송;윤명중;김정한;주훈
    • 전력전자학회논문지
    • /
    • 제10권2호
    • /
    • pp.203-210
    • /
    • 2005
  • IMT2000과 같은 휴대용 무선통신 시스템을 위한 혼성마이크로 동력원에 대한 연구를 수행하였다. 혼성마이크로 동력원은 태양전지, 슈퍼커패시터, 리튬이온 전지로 이루어져 있다. 주기적인 펄스성 부하에 대응하기 위하여, 슈퍼 커패시터가 리튬이온 전지와 병렬로 연결되어 펄스전류를 흡수한다. 태양전지는 배터리에 전류를 공금하며, 최대전력점에서 동작하도록 제어된다. 펄스성 부하에도 적용될 수 있는 최대전력점 추적기법이 소개되며, 실험을 통해서 완벽한 추적성능을 입증하였다. 혼성마이크로 동력원들 간의 매칭을 위한 제어기 설계 기법이 제시되며, 실험을 통해 성능을 입증하였다.

방수배열소나의 연산량 감소를 위한 펄스 시작점 산출 방법 (A method of determining pulse start points for reduction in computational amount of intercept array sonar)

  • 김도영;신기철;정태진;엄민정
    • 융합신호처리학회논문지
    • /
    • 제25권1호
    • /
    • pp.1-6
    • /
    • 2024
  • 방수배열소나의 주 기능은 적 수상함 및 잠수함, 어뢰 등에서 방사하는 펄스를 탐지하는 것이다. 펄스를 탐지한 경우에는 자함 입장에서 위험도가 높은 상황이므로 자함의 기동 및 생존을 위해 표적의 위치를 찾는 건 매우 중요하다. 표적의 위치는 각 센서에서 수신된 펄스의 시작점을 찾고 센서 간 시간지연 값을 계산하여 산출하게 된다. 펄스 시작점을 구하기 위해서는 신호의 포락선을 산출하고 미분 필터링 과정을 거치게 되는데 방수배열소나는 신호의 샘플링 주파수가 높아 처리하는 샘플 개수가 많으므로 이 과정은 연산량이 큰 문제가 있다. 이에 본 논문은 연산량을 줄일 수 있는 간축 적용 펄스 시작점 산출 방법을 제안하였다. 간축 계수를 변경하면서 시뮬레이션을 수행하였고 연산량이 감소함을 확인하였다. 제안한 방법은 실시간 처리 시스템에 효과적이며 자원 활용도에 장점을 가질 것으로 기대한다.

Atomic Layer Epitaxy 법에 의한 TiN 박막의 성장과 그 특성 (Growth and Characteristics of TiN Thin Films by Atomic Layer Epitaxy)

  • 이종화;김동진
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 추계종합학술대회 논문집
    • /
    • pp.581-584
    • /
    • 1998
  • TiN thin films were grown on (100) Si substrate by atomic layer epitaxy at 130 - $240^{\circ}C$ using TEMAT and NH3 as precursors. Reactants were injected into the reactor in sequence of TEMAT precursor vapor pulse, N2 purging gas pulse, NH3 gas pulse and N2 purging gas pulse so that gas-phase reactions could be removed. The films were characterized by means of x-ray diffraction(XRD), 4-point probe, atomic force microscopy(AFM) and auger electron spectroscopy(AES).

  • PDF