• Title/Summary/Keyword: Pulse Measurement

Search Result 947, Processing Time 0.029 seconds

Application of Parametric Acoustic Source to Fish Finding (Parametric 음원의 어탐이용에 관한 고찰)

  • Lee, Un-Hui;Jang, Ji-Won
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.23 no.4
    • /
    • pp.189-197
    • /
    • 1987
  • As the basic research for the application of a parametric acoustic source to fish finding, the characteristics of beam patterns and parametric gains of the acoustic source were investigated and target strengths of fish, grey mullet, with the acoustic source were measured. The mean primary frequency of the acoustic source was 200KHz and the produced sounds by difference-frequencies were 5KHz, 10KHz, 16KHz and 20KHz. For measurement of target strength in yaw (coronal) plane of fish the to be target was 34cm in length, the pulse duration of the source was 0.3m/sec and the difference frequency was 10KHz in consideration of the length of fish and of parametric gain of the acoustic source. The results obtained are as follow: 1. Beam widths(down 3 dB) of the parametric acoustic source excited at frequencies of 5KHz, 10KHz, 16KHz, and 20KHz were 4.3$^{\circ}$, 2.2$^{\circ}$, 3.0$^{\circ}$ and 2.5$^{\circ}$ respectively. 2. Parametric gains of the parametric acoustic source excited at frequencies of 5KHz, 10KHz, 16KHz and 20KHz were -41 dB, -45 dB, -60 dB and -68 dB respectively. 3. Target strengths of a fish in head and tail aspect using the parametric acoustic source were 5 dB lower than those using 200KHz single frequency sound, but those in side aspect were similar. 4. Target strengths of two or three fish with the parametric acoustic source were 1-3 dB lower than those in head and tail aspect using 200KHz single frequency sound.

  • PDF

Development of RF Stimulating Protocol for Effective Heat-Stimulus in Subcutaneous Tissue (피하에 효과적인 열 자극을 위한 고주파 자극 프로토콜 개발)

  • Myoung, Hyoun Seok;Lee, Dae Won;Kim, Han Sung;Lee, Kyoung Joung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.10
    • /
    • pp.194-201
    • /
    • 2012
  • Moxibustion is utilized not only to cure disease but also to increase immunity. However, it may lead to undesired effects including severe pains(blisters and burns) because of the difficulty of controlling heat intensity. To overcome these problems we developed the RF heat stimulation system which can control stimulus. Also, we developed the RF stimulation protocol for effective heat transfer in subcutaneous tissue of rabbit. RF stimulator consists of a medical RF capacitive heating device, isolation probe, isolation plate, negative pressure control part and temperature measurement part. For the designed stimulus protocol, we measured the temperature distribution on epidermis and in subcutaneous(5mm, 10mm) area of rabbit during moxibustion. A stimulation protocol was designed by controlling the ON/OFF duty ratio, repeating number, and energy of applied pulse to get the temperature distribution similar with that by moxibustion. In results, the correlation coefficients between temperature distribution by moxibustion and that of stimulator were 95% and 91% from 5mm and 10mm thick respectively. However, temperature distribution on epidermis by stimulator was remarkably lower than that of the moxibustion. Finally, the RF stimulation system showed that it can not only transfer effectively heat similar with moxibustion to the subcutaneous area, but also the influence by unwanted side effects can be minimized.

S-Band 300-W GaN HEMT Harmonic-Tuned Internally-Matched Power Amplifier (S-대역 300 W급 GaN HEMT 고조파 튜닝 내부 정합 전력증폭기)

  • Kang, Hyun-Seok;Lee, Ik-Joon;Bae, Kyung-Tae;Kim, Seil;Kim, Dong-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.4
    • /
    • pp.290-298
    • /
    • 2018
  • Herein, an S-band internally-matched power amplifier that shows a power capability of 300 W in a Long Term Evolution(LTE) band 7 is designed and fabricated using a CGHV40320D GaN HEMT from Wolfspeed. Based on the nonlinear model, the optimum source and load impedance are extracted from the source-pull and load-pull simulations at the fundamental and harmonic frequencies, and the harmonic impedance tuning circuits are implemented inside a ceramic package. The internally matched power amplifier, which is fabricated using a thin-film substrate with a high relative permittivity of 40 and an RF35TC PCB substrate, is measured at the pulsed condition with a pulse period of 1 ms and a duty cycle of 10%. The measured results show a maximum output power of 257~323 W, a drain efficiency of 64~71%, and a power gain of 11.5~14.0 dB at 2.62~2.69 GHz. The LTE-based measurement shows a drain efficiency of 42~49% and an ACLR of less than -30 dBc(excluding 2.62 GHz) at an average power of 79 W.

The Healing Effects of Concentration Meditation(CM) on Mind-Body - Focusing on Meditation of Dhammakaya Temple - (집중명상(Concentration Meditation:CM)이 심신치유(心身治癒)효과에 미치는 영향 -태국 담마까야(Dhammakaya)사원 명상법 중심으로-)

  • Seo, Byung-Chan
    • The Journal of the Korea Contents Association
    • /
    • v.20 no.2
    • /
    • pp.534-546
    • /
    • 2020
  • The purpose of this study is to prove the positive effect of mind and body healing through the modified meditation method of Southern Buddhism as a systematic practice to concentrate or empty consciousness of the Buddhist temple in Dhammakaya, Thailand. To investigate the effects of the program on the participants, the experimental measurement tools in this study include the Immeasurable scale, spirituality scale, simple mental test scale, and blood pressure scale, pulse meter, thermometer, and recorder. When the measured values were compared with the corresponding t-test, there were some differences before and after the measurements based on the significance probability p <0.05. As a result, there was a significant correlation between spiritual support scale and the Immeasurable scale. In addition, the results of analyzing the data through interviews showed that the body and physiologically effective concentration was well after the meditation experience, and the intention to actively utilize this meditation method was confirmed. In this study, it was confirmed that there was a positive effect of the Samata practice method of Concentration meditation(CM), and thus the theoretical and experimental effects of intensive meditation were presented. I hope that these studies will accumulate and follow-up studies will be conducted through intensive meditation as a healing effect.

A Study of The Effect of Waiting time for Operation in the Operating Room on Preoperative Patients (수술환자에 있어 수술실내에서 수술대기 시간이 불안에 미치는 영향에 관한 연구)

  • Lee, Hea-Won;Lee, Kyu-Chung;Kim, Hae-Ock;Lee, Haik-Ock;Kim, Hea-Suk;Lee, Mi-Kyung;Song, Mal-Soon
    • The Korean Nurse
    • /
    • v.29 no.3
    • /
    • pp.36-48
    • /
    • 1990
  • This study was attempted to provide us with basic information on how to improve understanding with patients for operation, and to offer then better nursing and treatment. This kind of study will help scientific application to nursing practice and operating room. The data was collected by interviewing 29 patients who underwent the elective surgery under the general anesthesia at Y hospital in Seoul. The interview ran from October 15 to December 15, 1989. The research instrument was a anxiety measurement device (SAAI) originally developed by Spielberger, et al and modified by Jung-Tack Kim. 1. Hypothesis Testing Hypothesis one was that there would be a difference in state anxiety level according to a time difference in watiting for operation. This hypothesis was rejected(state.anxiety level one hour before operation P>.05, r-.747, State anxiety level half an hour before operation P>.05, r-.1550, state anxiety level just before operation, P>.05, r=.1099). However, state anxiety, evel appeared to be associated with a longer watiting period, like one day before operation (P<.05, r-.4628). Hypothesis two was that there would be a difference according to state anxiety level of patients for operation. This was rejected. (Change of blood perssure in systolie P>.05 r=.1082, Change of blood pressure in diastolic P>.05, r=.088, Change of pulse rate, P>.05, r-1.909) 2. Examining trait anxiety and state anxiety levels, the average level of trait anxiety was 42.034, and the average level of state anxiety one day before operation was 43,000. The average level of state anxiety was averaged 42.356 in a waiting room for operation. 3. Examining the state anxiety level by time period, the one hour before was 42.379 the level half an hour before 42.276, and the level just before operation 42.414. The low level of state anxiety was due to the fact that premedication was not eliminated. 4. Age and time period like one day before operation was related to state anxiety level (F=5.271, P<.0.01) and blood pressure in waiting room for operation. That is, state anxiety level and blood pressure of patients one day before operation appeared high. Sex was relation to changes of blood pressure ; the blood pressure of male patients appeard higer than of female patients. A marital status was also related anxiety level one hour before operation the married patient for operation showed a higher state anxiety level than that of the unmarried patient for operation. Education was similarily related to trait anxiety level in which highly educated patients show lower levels of trait anxiety than poorly educated ones. Motive for hospitalization was related to state anxiety level for patient one hour before operation (F=6.464, P<.05) likewise, patients who are supposed to undergo operation hastily showed higher levels of anxiety than patients who expect elective surgeries.

  • PDF

Determination of Hg (II) Ion at a Chemically Modified Carbon Paste Electrode Containing L-Sparteine (L-Sparteine 수식전극을 사용한 Hg (II) 이온의 정량)

  • Euh Duck Jeong;Mi-Sook Won;Yoon-Bo Shim
    • Journal of the Korean Chemical Society
    • /
    • v.35 no.5
    • /
    • pp.545-552
    • /
    • 1991
  • A mercury ion-sensitive carbon-paste electrode (CPE) was constructed with l-sparteine. Mercury (II) ion was chemically deposited by the complexation with l-sparteine onto the CPE. The surface of CPEs was characterized by cyclic voltammetry and anodic stripping voltammetry in an acetate buffer solution, separately. Exposure of CPEs to acid solution could regenerate surface and reuse it for deposition. In 5 deposition/measurement/regeneration cycle, the response was reproducible and in licnear up to $2.0\;{\times}\;10^{-6}$ M with linear sweep voltammetry. In case of using the differential pulse technique, we have obtained the linear response up to $7.0 {\times}10^{-7}$ M with relative standard deviation of ${\pm}5.1$%. The detection limit was $5.0{\times}10^{-7}$ M for 20 minutes of the deposition. We have investigated the interference effect of various metal ions, which are expected to form the complex with ligand. Silver (I) ion of these has interfered with the analysis of Hg (II) ions. However, pretreatment of the silver (I) ion with potassium chloride led to no interference on the analysis of mercury ions in aqueous solution.

  • PDF

Detection of a Surface-Breaking Crack Using the Surface Wave of a Laser Ultrasound (레이저 초음파의 표면파를 이용한 표면결함 측정)

  • Park, Seung-Kyu;Jung, Hyun-Kyu;Baik, Sung-Hoon;Lim, Chang-Hwan;Joo, Young-Sang;Kang, Young-June
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.2
    • /
    • pp.84-89
    • /
    • 2006
  • A laser ultrasonic inspection system is a non-contact inspection device which generates and measures ultrasounds by using laser beams. A laser ultrasonic inspection system provides a high measurement resolution because the ultrasonic signal generated by a pulse laser beam has a wide-band spectrum and the ultrasonic signal is measured from a small focused spot of a measuring laser beam. In this paper, we have investigated the detection techniques of a surface-breaking crack by using the laser ultrasonic surface waves. A crack acts as a low pass filter whose cut-off frequency is lowered in proportion to the depth of a crack. And, the center frequency value of a spectrum is decreased in proportion to the depth of a crack. In this paper, we extracted the crack information by using the frequency attenuation from the normalized transfer function spectrum of a surface-breaking crack. Also, we effectively measured the crack depth by using the decreasing value of the center frequency from a crack passed ultrasonic signal. The proposed measuring techniques of crack depths provided more precise information than the amplitude measuring technique.

Voltammetric Determination of Cu(II) Ion at a Chemically Modified Carbon-Paste Electrode Containing 1-(2-pyridylazo)-2-naphthol (1-(2-Pyridylazo)-2-naphthol 수식전극을 사용한 Cu(II) 이온의 전압전류법적 정량)

  • Jun-Ung Bae;Hee Sook Jun;Hye-Young Jang
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.8
    • /
    • pp.723-729
    • /
    • 1993
  • Cu(II) ion-responsive chemically modifed electrodes (CMEs) were constructed by incorporating 1-(2-pyridylazo)-2-naphthol (PAN) into a conventional carbon-paste mixture of graphite powder and Nujol oil. Cu(II) ion was chemically deposited on the surface of the PAN-chemically modified electrode in the absence of an applied potential by immersion of the electrode in a buffer solution (pH 3.2) containing Cu(II) ion, and then reduced at a constant potential in 0.1 M KNO$_3$. And a well-defined voltammetric peak could be obtained by scanning the potential to the positive direction. The electrode surface could be regenerated with exposure to acid solution and reused for the determination of Cu(II) ion. In 5 deposition / measurement / regeneration cycles, the response could be reproduced with 6.1${\%}$ relative standard deviation. In case of using the differential pulse voltammetry, the calibration curve for Cu(II) was linear over the range of 2.0 ${times}$ 10$^{-7}$ ∼ 1.0 ${times}$ 10$^{-6}$ M. And the detection limit was 6.0 ${times}$ 10$^{-8}$ M. Studies of the effect of diverse ions showed that Co, Ni, Zn, Pb, Mg and Ag ions added 10 times more than Cu(II) ion did not influence on the determination of Cu(II) ion, except EDTA and oxalate ions.

  • PDF

Effect of Therapy on Stress and Quality of Life in Patients Undergoing Hemodialysis (음악요법이 혈액투석환자의 스트레스와 삶의 질에 미치는 영향)

  • 김영옥
    • Journal of Korean Academy of Nursing
    • /
    • v.23 no.3
    • /
    • pp.431-452
    • /
    • 1993
  • This study was done to determine the effect of music therapy on stress and quality of life in patients undergoing hemodialysis. The research design was a nonequivalent control group pre -post test design. The subjects consisted of 21 patients who received hemodialysis in two hospitals located in Kwang Ju. The fourteen receiving treatment in one hospital were assigned to the experimental group and the seven in the other hospital to the control group. Data were gathered from December 14, 1992 to January 16, 1993 through questionnaires and physiological measurement. Data were analyzed by the SAS package using frequency, t-test, paired t-test and Pearson Prod uct - Moment Correlation Coefficient. The results of this study are summarized as follows ; 1. There were no significant differences between the two groups on stress scores and quality of life scores before the treatment. 2. The mean score on the psychological stress scale for the patients undergoing hemodialysis was 2.48 out of a maximum mean score of four, the items with high stress scores were “feeling of weakness and annoyed by everything”, “limitation of food”, “limitation of fluid”, “change in skin color” in that order. The psychological category showed the highest stress score followed by developmental, scoioeconomic and physiological stress categories in that order. 3. In the experimental group, post - test diastolic blood pressure decerased significantly(t=3.24, p=0.0064), but in the control group pre and post - test diastolic blood pressure were not different. 4. There was no difference between the two groups on the pre and post -test psychological stress scores or the depression scores. 5. The mean score of quality of life for patients undergoing hemodialysis was 2.75 out of a maxi-mum mean score of five. The category of ‘emtional state’ showed the highest score followed by ‘self - esteem’, ‘physical state and function’, ‘economic life’, ‘relationship with neighbors’ and ‘family relationship’ categories in that order. There was no significant difference in the pre and post - test quality of life scores between the two groups. 6. Hypothesis 1 that patients undergoing hemodialysis who received music therapy would have less stress than patients undergoing hemodialysis who did not receive music therapy is divided into two sub - hypotheses. 1) The first sub-hypothesis that patients undergoing hemodialysis who received music therapy would have less physiological stress than patients undergoing hemodialysis who did not receive music therapy was partly supported. Among three physiological stress indices (pulse, systolic blood pressure, diastolic blood pressure), only diastolic blood pressure decreased significantly after the treatment in the experimental group. 2) The second sub-hypothesis that patients undergoing hemodialysis who received music therapy would have less psychological stress than patients undergoing hemodialysis who did not receive music therapy was not supported. Psychological stress score and depression score were not significantly different before and after the treatment. 7. Hypothesis 2 that patients undergoing hemodialysis who received music therapy would have a higher quality of life score than patients undergoing. hemodialysis who did not received music therapy was not supported. There were no significant changes in the quality of life scores before and after the treatment.

  • PDF

Measurement of Spatiotemporal Distribution for the Density of Excited Xe Atoms in the 1s5 in Accordance with Various ITO-shapes in Ac-PDP (교류형 플라즈마 평판 표시장치(AC-PDP)에서 ITO 전극 구조에 따른 Xe 여기종의 시공간 밀도 분포 연구)

  • Cho, S.H.;Hong, Y.J.;Son, C.G.;Han, Y.G.;Jeong, Y.H.;Gwon, G.C.;Hong, B.H.;Cho, G.S.;Choi, E.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.1
    • /
    • pp.54-59
    • /
    • 2009
  • We have measured the spatiotemporal behavior for the density of excited Xe atoms in the $1s_5$ metastable states by laser absorption spectroscopy in accordance with various shapes of ITO electrode. The maximum density of excited Xe atoms in the Is5 state in a discharge cell for fish-boned, T-shaped and squared ITO electrodes has been measured to be $3.01{\times}10^{13}\;cm^{-3}$, $2.66{\times}10^{13}\;cm^{-3}$ and $2.06{\times}10^{13}\;cm^{-3}$, respectively. Throughout this experiment, we could understand the influence of the shapes of ITO electrode of micro discharge cell on the high efficiency of AC-PDPs.