• 제목/요약/키워드: Pullout-test

검색결과 248건 처리시간 0.023초

A Study on the Development Length of Fiber Reinforced Polymer Tendon by Direct Pullout Test (직접인발실험에 의한 FRP Tendon의 정착 길이 산정에 관한 연구)

  • Lee, Seung-Joo;Jung, Woo-Tai;Park, Young-Hwan;Hwang, Geum-Sic
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.837-840
    • /
    • 2006
  • This paper presents the experimental results on the development length of FRP tendons by direct pullout test. Two types of FRP tendons, namely, CFCC tendon and KICT tendon, and PS tendon were investigated. The development length defined as the minimum embedment length required to develop the ultimate tensile strength was suggested using the test results. It was found that the development length from the direct pullout test was greater than those of various standards. This may result from the fact that the wedge effect does not exist because there is no prestressing force in the direct pullout test. Further study and experiment are necessary to derive the reasonable development length for FRP tendon.

  • PDF

Pullout Resistance of Geosynthetic Strip with Rounded Band Anchor (수동저항부가 형성된 띠형 섬유보강재의 인발저항 특성)

  • Lee, Kwang-Wu;Cho, Sam-Deok;Han, Jung-Geun;Hong, Ki-Kwon
    • Journal of the Korean Geosynthetics Society
    • /
    • 제10권3호
    • /
    • pp.43-51
    • /
    • 2011
  • This paper describes the results of pullout tests in the laboratory, which are conducted to assess the pullout performance of recently developed geosynthetic strip reinforcement with rounded band anchor. The geosynthetic strip can be used as reinforcements in reinforced soil wall with concrete block facing. The pullout resistance of the geosynthetic strip with rounded band anchor is mobilized by the combination of the interface friction between soil-reinforcement surface and the passive soil resistance caused by the rounded band anchor. Therefore, both the friction resistance and the passive resistance have to be considered in design. From the pullout test results, when the rounded band anchor are formed in the end part of the geosynthetic strip, pullout strength increases about from 10% to 65%. The passive resistance can be evaluated based on the pullout test results.

Pullout Test of Headed Reinforcing Bar in RC or SFRC Members with Side-Face Blowout Failure

  • Lee, Chang-Yong;Kim, Seung-Hun;Lee, Yong-Taeg
    • Architectural research
    • /
    • 제22권1호
    • /
    • pp.33-39
    • /
    • 2020
  • In this study, side-face blowout failure strength of high strength headed reinforcing bar, which is vertically anchoring between RC or SFRC members, is evaluated throughout pullout test. The major test parameters are content ratio of high strength steel fibers, strength of rebar, length of anchorage, presence of shear reinforcement, and the side concrete cover thickness planned to be 1.3 times of the rebar. In pullout test, tensile force was applied to the headed reinforcing bar with the hinged supports positioned 1.5 and 0.7 times the anchorage length on both sides of the headed reinforcing bar. As a result, the cone-shaped crack occurred where the headed reinforcing bar embedded and finally side-face blowout failure caused by bearing pressure of the headed reinforcing bar. The tensile strength of specimens increased by 13.0 ~26.2% with shear reinforcement. The pullout strength of the specimens increased by 3.6 ~15.4% according to steel fiber reinforcement. Increasing the anchoring length and shear reinforcement were evaluated to reduce the stress bearing ration of the total stress.

대구경 소켓경사반력말뚝의 인발거동에 관한 연구

  • 최용규;김상옥;정창규;정성기;김상일
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 한국지반공학회 2000년도 가을 학술발표회 논문집
    • /
    • pp.277-284
    • /
    • 2000
  • Using the large diameter (D = 2,500mm, L = 40m) batter steel pipe piles, designed as compression piles but used as reaction piles during the static compression load test of socketed test piles (D = 1,000mm, L = 40m), static pile load tests for large diameter instrumented rock-socketed piles were performed. The reaction steel pipe piles were driven 20m into the marine deposit and weathered rock layer and then l0m socketed with reinforced concrete through the weathered rock layer and into hard rock layer. Steel pipe and concrete in the steel pile part, and concrete and rebars in the socketed parts were instrumented to measure strains in each part. The pullout amounts of reaction pile heads were also measured with LVDT. During the static pile load test, total compressional load of about 20MN was loaded on the head of test piles, but load above 20MN was not loaded due to lack of loading capacity of loading system. Over the course of the study, maximum pullout amount up to 7mm was measured in the heads of reaction piles when loaded op to 10MN and 1mm of pullout amount was measured. More than 85% of pullout load was transfered in the residual weathered rock layer and about 10% in the soft rock layer, which was somewhat different transfer mechanism in the static compressional load tests.

  • PDF

Anchorage mechanism and pullout resistance of rock bolt in water-bearing rocks

  • Kim, Ho-Jong;Kim, Kang-Hyun;Kim, Hong-Moon;Shin, Jong-Ho
    • Geomechanics and Engineering
    • /
    • 제15권3호
    • /
    • pp.841-849
    • /
    • 2018
  • The purpose of a rock bolt is to improve the mechanical performance of a jointed-rock mass. The performance of a rock bolt is generally evaluated by conducting a field pullout test, as the analytical or numerical evaluation of the rock bolt behavior still remains difficult. In this study, wide range of field test was performed to investigate the pullout resistance of rock bolts considering influencing factors such as the rock type, water bearing conditions, rock bolt type and length. The test results showed that the fully grouted rock bolt (FGR) in water-bearing rocks can be inadequate to provide the required pullout resistance, meanwhile the inflated steel tube rock bolt (ISR) satisfied required pullout resistance, even immediately after installation in water-bearing conditions. The ISR was particularly effective when the water inflow into a drill hole is greater than 1.0 l/min. The effect of the rock bolt failure on the tunnel stability was investigated through numerical analysis. The results show that the contribution of the rock bolt to the overall stability of the tunnel was not significant. However, it is found that the rock bolt can effectively reinforce the jointed-rock mass and reduce the possibility of local collapses of rocks, thus the importance of the rock bolt should not be overlooked, regardless of the overall stability.

Pullout Resistance of Geogrid Reinforced Soil according to Compaction Degree (흙의 다짐도에 따른 인발저항특성 연구)

  • 주재우;김병욱;박종범
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 한국지반공학회 1999년도 토목섬유 학술발표회 논문집
    • /
    • pp.11-20
    • /
    • 1999
  • The method which makes the soft ground reinforced by using the geogrid, a kind of geosynthetics has been getting popular and its usefulness also has been increased due to reduction in costs, ease of construction and great exterior view, But the study on the frictional characteristics, which is the important factor in design, between reinforcement and soil is insufficient. In this study, compaction degrees were considered through large-scale pullout tests. As a part of studying on estimation of pullout frictional characteristics between soil and geosynthetics, pullout tests were peformed and from the result of pullout tests, pullout frictional parameters between soil and geosynthetics were obtained and pullout behaviors were learned.

  • PDF

Pullout Resistance by Horizontal Spacing of Geosynthetic Strip (띠형 섬유보강재의 설치간격에 따른 인발저항 특성에 관한 연구)

  • Han, Jung-Geun;Yoon, Won-Il;Hong, Ki-Kwon;Lee, Kwang-Wu;Kim, Ju-Hyong;Cho, Sam-Deok
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.315-324
    • /
    • 2010
  • In this study, the pullout tests are conducted to evaluate the pullout resistance of the geosynthetic strip with or without bearing resistance zone. The test results are indicated that the pullout resistance of the geosynthetic strip without bearing resistance zone is not affected by horizontal spacing. However, the horizontal spacing of reinforcement with bearing resistance zone affects the bearing resistance. In other words, it is indicated that the bearing resistance at spacing of 210mm is larger than that at spacing of 260mm. This means that the pullout strength at spacing of 210mm is larger than that at spacing of 260mm. Therefore.

  • PDF

Pullout Resistance of Steel Strip Reinforcement with Transverse Members using Large-scale Pullout Tests (대형인발시험을 이용한 수동지지저항 부재가 설치된 강재스트립 보강재의 인발저항 평가)

  • Lee, Kwang-Wu;Cho, Sam-Deok;Han, Jung-Geun;Hong, Ki-Kwon
    • Journal of the Korean Geosynthetics Society
    • /
    • 제8권4호
    • /
    • pp.1-8
    • /
    • 2009
  • In this study, the large-scale pullout tests are conducted to evaluate pullout resistance of steel strip reinforcement with transverse members. The test results clearly showed the passive effect by normal stress. This suggests that both friction resistance and passive resistance by normal stress should be taken into account in the evaluation of pullout resistance for design. Therefore, The evaluation results confirmed that the developed steel strip reinforcement with transverse members depend heavily on passive resistance by normal stress.

  • PDF

Test of Headed Reinforcement in Pullout II: Deep Embedment

  • Choi, Dong-Uk
    • International Journal of Concrete Structures and Materials
    • /
    • 제18권3E호
    • /
    • pp.151-159
    • /
    • 2006
  • A total of 32 pullout tests were performed for the multiple headed bars relatively deeply embedded in reinforced concrete column-like members. The objective was to determine the minimum embedment depth that was necessary to safely design exterior beam-column joints using headed bars. The variables for the experiment were embedment depth of headed bar, center-to-center distance between adjacent heads, and amount of supplementary reinforcement. Regular strength concrete and grade SD420 reinforcing steel were used. The results of the test the indicated that a headed bar embedment depth of $10d_b$ was not sufficient to have relatively closely installed headed bars develop the pullout strength corresponding to the yield strength. All the experimental variables, influenced the pullout strength. The pullout strength increased with increasing embedment depth and head-to-head distance. It also increased with increasing amount of supplementary reinforcement. For a group of closely-spaced headed bars installed in a beam-column joint, it is recommended to use column ties at least 0.6% by volume, 1% or greater amount of column main bars, and an embedment depth of $13d_b$ or greater simultaneously, to guarantee the pullout strength of individual headed bars over 125% of $f_y$ and ductile load-displacement behavior.

The Study on Pullout Resistance Characteristics of the Compression Anchor by Pullout Tests on the Field (현장실험에 의한 압축형 앵커의 인발거동특성 연구)

  • 홍석우
    • Journal of Ocean Engineering and Technology
    • /
    • 제16권2호
    • /
    • pp.44-52
    • /
    • 2002
  • The mechanism of pullout resistance of compression anchor is analysed. This anchor is developed through the field pullout tests and the laboratory element test. The compression anchor is characterized by decrease of progressive failure, simple site work, economy and durability compared with tension anchor. The characteristics of compression anchor, compared with tension anchor. mainly are summarized as follows ; (1) The plastic displacement of anchor body is very small during pullout of anchor. (2) Total anchor length decreases by the shortening of free length; (3) The progressive failure is decreased.; (4) The safety factor for pullout resistance increases with time after construction of anchor.