A Study on the Development Length of Fiber Reinforced Polymer Tendon by Direct Pullout Test

직접인발실험에 의한 FRP Tendon의 정착 길이 산정에 관한 연구

  • 이승주 (한국건설기술연구원 구조연구부) ;
  • 정우태 (한국건설기술연구원 구조연구부) ;
  • 박영환 (한국건설기술연구원 구조연구부) ;
  • 황금식 (동원건설주식회사)
  • Published : 2006.11.04

Abstract

This paper presents the experimental results on the development length of FRP tendons by direct pullout test. Two types of FRP tendons, namely, CFCC tendon and KICT tendon, and PS tendon were investigated. The development length defined as the minimum embedment length required to develop the ultimate tensile strength was suggested using the test results. It was found that the development length from the direct pullout test was greater than those of various standards. This may result from the fact that the wedge effect does not exist because there is no prestressing force in the direct pullout test. Further study and experiment are necessary to derive the reasonable development length for FRP tendon.

Keywords