• Title/Summary/Keyword: Proximal femur fracture

Search Result 46, Processing Time 0.02 seconds

Femur Fractures Associated with Benign Bone Tumors in Children (양성 골종양을 동반한 소아 대퇴골의 병적 골절)

  • Jung, Sung-Taek;Kim, Byung-Soo;Moon, Eun-Sun;Lee, Keun-Bae;Seo, Hyoung-Yeon
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.11 no.2
    • /
    • pp.111-117
    • /
    • 2005
  • Purpose: We evaluate the results of treatment of pathologic femur fractures secondary to bone tumors in children. Materials and Methods: Between January 1995 and June 2004, 18 patients(20 cases) were evaluated. Their mean age of the first episode of fracture was 10.2 years and mean follow-up period is 42.5 months. Primary bone tumors, the location of fracture, time to union and complications were evauated. Results: Fractures occurred at proximal portion in 14 cases, shaft 3 cases and distal portion 3 cases. The bone tumors causing pathologic fracture were fibrous dysplasia(9 c ases), simple bone cyst(4 cases), aneurysmal bone cyst(4 cases), nonossifying fibroma(2 cases) and eosinophilic granuloma(1 case). In the treatment for fractures, cast was in 11 cases, internal fixation 8 cases and external fixation in 1 case. In the treatment for tumors, observation was in 11 cases, curettage & bone graft in 8 cases and resection in 1 case. In polyostotic fibrous dysplasia, all cases were treated by cast initially but deformity developed in all cases. Fracture prevention and deformity correction were obtained with intramedullary nailing. Conclusion: Adequate choice of treatment of bone tumor and fracture will result in good prognosis.

  • PDF

A Study on the Age-related Remodeling of Femur in Normal Korean Adult (연령증가에 따른 정상 한국인 대퇴골의 재형성에 관한 연구)

  • Kang, S.B.;Ba, T.S.;Choi, J.B.;Choi, K.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.489-492
    • /
    • 1997
  • The general pattern of adaptation in the appendicular skeleton with aging is that the subperiosteal apposition of bone occur along with endosteal absorption. This remodeling of diaphysis to a cylinder of larger diameter is hypothesized to serve a mechanical compensatory unction by increasing the moment of inertia as the cortex thins with aging. These findings is only true of the diaphysis of long bone. Measuring the area and inertia at each section of femur, the age-related change of proximal emur and diaphysis is observed. After screening by physical and radiological examination, 200 normal Korean adults divided 5 groups in both male and female based on age. Twenty persons were in each group. One femur in each person was analyzed using CT images. femur scanned with 60 to 80 slices and this images were digitized. Then 2-D images were reconstructed into 3-D images. Using the nonlinear method, normalization and interpolation technique, 7 locations of interest (trochanteric area: 1, 2 subtrochanteric area: 3, 4, isthmic area: 5, 6, 7) were determined. On the each cross section at each location, the area (total, cortical and medullary) and 5 inertia of moment were measured. The results were analyzed statistically. With aging, significant area change occurred mainly in diaphysis and female. In trochanteric area, no significant change was noted. With aging, total and medullary area were increased, but cortical area was not changed. In diaphysis, lateral bendingresistanceincreasedsignificantly. No inertia change was noted in trochanteric area. Anteroposterior bending resistance was constant with aging. In more than age 60, total area and medullary area were larger than that of others. Lateral bending resistance was higher especially in diaphysis. In diaphysis, with aging, the decreased properties is compensated with the increased lateral bending resistance by geometric remodeling. In trochanteric area, no compensation occur. With aging, especially in more than age 60, the higher rate of trochanteric fracture is expected.

  • PDF

Surgical Treatment for Pathologic Fracture of Skeletal Metastatic Lesion of the Proximal Femur: Comparison of Clinical Outcomes for Prosthetic Joint Replacement and Osteosynthetic Fixation (근위 대퇴골에 발생한 전이성 골종양의 병적 골절의 수술적 치료: 종양대치 인공관절 치환술과 골절 고정술의 치료 성적 비교)

  • Shin, Duk-Seop;Kim, Ui-Sik;Kwak, Hae-Jun;Ko, Young-Jin
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.17 no.1
    • /
    • pp.44-50
    • /
    • 2011
  • Purpose: To compare clinical outcomes of the tumor prosthetic replacement and osteosynthetic fixation for pathologic fracture of skeletal metastatic lesion of the proximal femur. Materials and Methods: From 1994 May to 2009 May, medical records of 22 patients who underwent tumor prosthetic replacement with tumor resection (group 1) and 15 others (16 hips) who underwent osteosynthetic fixation without tumor resection (group 2) were reviewed. The mean age of overall patients were 59 (group 1) and 60 (group 2). Mean follow up periods were 23 and 11 months. The oncological and functional results were evaluated with Kaplan-Meier methods and Musculoskeletal Tumor Society (MSTS) scoring system, 1993. The statistical evaluation was assessed with Log rank test and t-test. Results: The mean survival periods were 24 months in group 1 and 11months in group 2. The 1 year survival rates were 86% in group 1 and 50 % in group 2, and 2 year survival rates were 29.7% in group 1 and 9.4% in group 2. The mean MSTS functional score were 26.4 (19-30), 87.9% in group 1 and 15.3 (10-23), 51.0% in group 2. Conclusion: The results of tumor resection and prosthetic replacement in selected cases was better than osteosynthetic fixation without tumor resection for metastatic bone tumors around proximal femur in oncological and functional aspects.

Stress Analysis of Femoral Stems on Non-Cemented Total Hip Replacement - A Three-Dimensional Finite Element Analysis -

  • Kim, Sung-Kon;Chae, Soo-Won;Jeong, Jung-Hwan
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.263-266
    • /
    • 1997
  • Three dimensional numerical model based on the finite element method(FEM) were developed to predict the mechanical behavior of hip implants. The purpose of this study is to investigate the stress distribution of two types of cementless total hip replacement femoral component -a straight stem and a curved stem, and to compare their effect on the stress shielding between two types by three dimensional finite element method. The authors analyzed von Mises stress in the cortex & stem and compared the stress between the straight and the curved stem. In comparison of stresses between two different design of femoral stem, there was 25% more decrease of stress in straight stem than curved stem in the medial cortex at proximal region. The straight stem had consistently much lower stresses than the curved stem throughout the whole medial cortex with maximum 70% reduction of stress. However, there was little change in stress between nature and 2 implanted femur throughout the lateral cortex. Stress of femoral stem was much higher in the straight stem than the curved stem up to 60%. The straight stem had more chance of stress shielding and a risk of fatigue fracture of the stem compared with the curved stem in noncement hip arthroplasty. In design of femoral stem still we have to consider to develop design to distribute more even stress on the proximal medial cortex.

  • PDF

Biomechanical Finite Element Analysis of Bone Cemented Hip Crack Initiation According to Stem Design

  • Kim, Byeong-Soo;Moon, Byung-Young;Park, Jung-Hong
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.12
    • /
    • pp.2168-2177
    • /
    • 2006
  • The purpose of this investigation was to determine the specific fracture mechanics response of cracks that initiate at the stem-cement interface and propagate into the cement mantle. Two-dimensional finite element models of idealized stem-cement-bone cross-sections from the proximal femur were developed for this study. Two general stem types were considered; Rectangular shape and Charnley type stem designs. The FE results showed that the highest principal stress in the cement mantle for each case occurred in the upper left and lower right regions adjacent to the stem-cement interface. There was also a general decrease in maximum tensile stress with increasing cement mantle thickness for both Rectangular and Charnley-type stem designs. The cement thickness is found to be one of the important fatigue failure parameters which affect the longevity of cemented femoral components, in which the thinner cement was significantly associated with early mechanical failure for shot-time period.

Periprosthetic Fracture around a Cemented Stem in Total Hip Arthroplasty

  • Jun-Young Heu;Ju-Yeong Kim;Se-Won Lee
    • Hip & pelvis
    • /
    • v.34 no.3
    • /
    • pp.140-149
    • /
    • 2022
  • The increase in the number of primary total hip arthroplasties that will be performed over the next several decades will lead to an increase in the incidence of periprosthetic fractures around the femoral stem. A search of targeted articles was conducted using on-line databases of PubMed (National Library of Medicine) and articles were obtained from January 2008 to November 2021. Reliable prediction of treatment can be achieved using the Vancouver classification; internal fixation is indicated in fractures involving a stable implant and revision arthroplasty is indicated in those with unstable prostheses. To the best of our knowledge, relatively fewer studies regarding periprosthetic proximal femur fractures of cemented stems have been reported. The focus of this review is on the risk factors and strategies for treatment of these fractures for periprosthetic femoral fractures around a cemented hip arthroplasty.

Functional and Radiological Results of Intermediate-term Follow Up in $MUTARS^{(R)}$ Tumor Endoprostheses ($MUTARS^{(R)}$ 종양 대치물을 이용한 사지 구제술의 기능적 및 방사선학적 중기 추시 결과)

  • Kang, Dong-Joon;Kim, Jeung-Il;Oh, Jong-Seok;Moon, Tae-Yong;Lee, In-Sook
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.17 no.1
    • /
    • pp.36-43
    • /
    • 2011
  • Purpose: This study was designed to verify intermediate-term functional and radiological results of limb salvage operation using endoprosthetic replacement system ($MUTARS^{(R)}$) used in patients with a malignant bone tumor. Materials and Methods: Thirty one cases which used $MUTARS^{(R)}$ tumor prosthesis were reviewed. The mean age of the patients was 49.2 years and the mean follow up was 39.8 months. We retrospectively reviewed complications, and evaluated functionally and radiologically by Enneking functional score, ISOLS radiological implants evaluation system at last follow-up. Results: 3 patients had died of disease, distant metastasis was seen in 4 patients and local recurrence was seen in 1 patients. Complications were developed in 12 patients. (infection 6, leg length discrepancy 2, aseptic loosening 2, periprosthetic femoral fracture 1, screw loosening 1) Mean value of total functional scores were 81.2% in proximal femur, 77.4% in distal femur, 78.1% in proximal tibia, and 80.2% in proximal humerus. The overall radiological result was relatively satisfactory. Conclusion: Our results suggest limb salvage with the $MUTARS^{(R)}$ endoprosthesis is successful with good functional and radiological results. But we should be careful with complications such as infection.

The Role of Angled Blade Plate in Treatment of Bone Tumor Occurred in Femur (대퇴골 골종양의 치료에 있어서의 Angled Blade Plate의 역할)

  • Kim, Tai-Seung;Kang, Chang-Nam;Chung, Ung-Seo
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.11 no.2
    • /
    • pp.175-182
    • /
    • 2005
  • Purpose: Bone tumor occurred in femur frequently involve proximal intertrochanteric region or distal metaphyseal region. Sometimes, the pathologic fracture can happen according to the size of tumor due to the substantial biomechanical stresses. Therefore, the prognosis can be improved biomechanically by the angled blade plate considering the anatomic configuration after the excision of tumor. Materials and Methods: Between October 1991 and April 2005, there were a total of 16 patients(17 cases) who were treated by the excision of tumor and internal fixation with the angled blade plate for bone tumor occurred in femur. After the excision of tumor, we filled the cavity by bone graft in 11 cases and bone cement in 6 cases. The internal fixation was used by angled blade plate in all cases. Result: The average follow-up time was 55.5 months(6-144 months) in 16 patients(17 cases). No metal failure occurred after the operation. Reoperation was performed in 4 cases due to tumor recurrence, and the internal fixation was firm until that. Conclusion: The angled blade plate can prevent the fracture until grafted bone incorporated to host bone, and protect fragile connection between cement and host bone.

  • PDF

Reconstruction with Extracorporeally Radiated Autogenous Bone Graft After Wide Resection of Bone Tumors (골종양 절제후 방사선 조사한 자가골을 이용한 재건술)

  • Lee, Jong-Seok;Jeon, Dae-Geun;Kim, Sug-Jun;Lee, Soo-Yong;Yang, Hyun-Seok
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.3 no.1
    • /
    • pp.32-38
    • /
    • 1997
  • PURPOSE : For the reconstruction of large bone defect after tumor resection, it is possible to reuse the bone involved by tumor with some treatment to it. Several bone-reusing methods have been reported such as autoclaving, low-heat treatment(pasteurization) and intraoperative radiotherapy. We have used extracorporeally radiated autogenous bone graft for reconstruction after tumor resection, and analyzed the periods for junctional union, functional results and complications to know the indications of this method. METHODS : From Dec. 1993 to Sept. 1995, nine patients had taken autogenous bone graft with extracorporeal irradiation. Eight cases were osteosarcoma and 1 giant cell tumor. The graft sites were 5 in femur, 3 proximal tibia and 1 femur and tibia. Stage 3 was 1 case(GCT), Stage IIB 3 and Stage IIIB 5. After wide resection, surrounding soft tissue and intramedullary and extramedullary portion of the tumor were removed. Radiation was done in 5000cGy to the resected bone. Ender nails and bone cement were inserted and filled into the medulla to prevent fracture. RESULTS : Average follow-up period was 12.3(4 to 21) months. Average junctional union period in simple X-ray was 6.5 months in 4 cases. Average functional score following Enneking's criteria was 19(12-27). Complications were as follows ; condylar fractures and femur neck fracture in 4 cases, subluxation of the knee joint 3 and infection 1. Although local recurrence was detected in 1 case, the site of recurrence was not in the radiated bone but surrounding soft tissue. At final follow-up, no recurrence was found in one case(GCT), CDF 2, AWD 2, DOD 3, and died of chemotherapy related sepsis 1. CONCLUSIONS : Extracorporeally radiated bone autograft is considered to be a method for reconstruction of the large bone defect made by tumor resection, especially in the reconstruction around the joint.

  • PDF

Updated Surgical Techniques and Expanded Indications of Free Vascularized Fibular Graft

  • Park, Jong Woong
    • Archives of Reconstructive Microsurgery
    • /
    • v.24 no.2
    • /
    • pp.41-49
    • /
    • 2015
  • Free or pedicled vascularized fibular grafts (VFG) are useful for the reconstruction of large skeletal defects, particularly in cases of scarred or avascular beds, or in patients with combined bone and soft tissue defects. Compared to non-VFG, VEG, which contains living osteocytes and osteoblasts, maintains its own viability and serves as good osteoconductive and osteoinductive graft. Due to its many structural and biological advantages, the free fibular osteo- or osteocutaneous graft is considered the most suitable autograft for the reconstruction of long bone defects in the injured extremity. The traditional indication of VFG is the long bone and soft tissue defect, which cannot be reconstructed using a conventional operative method. Recently, the indications have been widely expanded not only for defects of midtibia, humerus, forearm, distal femur, and proximal tibia, but also for the arthrodesis of shoulder and knee joints. Because of its potential to allow further bone growth, free fibular epiphyseal transfer can be used for the hip or for distal radius defects caused by the radical resection of a tumor. The basic anatomy and surgical techniques for harvesting the VFG are well known; however, the condition of the recipient site is different in each case. Therefore, careful preoperative surgical planning should be customized in every patient. In this review, recently expanded surgical indications of VFG and surgical tips based on the author's experiences in the issues of fixation method, one or two staged reconstruction, size mismatching, overcoming the stress fracture, and arthrodesis of shoulder and knee joint using VFG are discussed with the review of literature.