• 제목/요약/키워드: Protective concrete

검색결과 116건 처리시간 0.023초

콘크리트 구조물의 철근 방식성능 실험평가 (An Evaluation of Corrosion Protective Systems for Reinforcing Steel in Concrete)

  • 허준;홍기섭;오승모;장지원;최응규;최완철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 가을 학술발표회 논문집
    • /
    • pp.275-280
    • /
    • 1997
  • An experimental study to evaluate corrosion protection systems was undertaken with 47 reinforced concrete slab specimens subjected to cyclic wet and dry saltwater exposure. Corrosion measurements included monitoring marcrocell corrosion currents, which are generally accepted in United States practice. Test results indicate that specimens containing 2 kg/$\textrm{m}^3$ of NaCl an exposed to a 10 percent of NaCl show high values of corrosion currents. For the specimens with water repellent membrane currents kept relatively low numerical values, while test specimens with surface corrosion inhibitor hyprotective systems show high values of corrosion currents. No clear indication of the corrosion inhibitor protective systems might be due to the extremely high chloride exposure of the specimens, which has brought the accelerated corrosion. It would be expected that evaluation of the corrosion protective systems need long-term measurement with specimen exposed les chloride but simulating the real condition.

  • PDF

155mm 포탄 및 C-4 90kg 기폭에 의한 야전구축 방호자재 및 구조체용 신방호자재의 방호성능 평가 (Evaluation of Protective Performance of Protection Materials for Field and Structural Body by Ignition of 155mm Artillery Shell and C-4 Explosive)

  • 이인철;김홍섭;남정수;김석봉;홍원희;김규용
    • 한국군사과학기술학회지
    • /
    • 제16권4호
    • /
    • pp.493-500
    • /
    • 2013
  • In this study, it was evaluated the protective performance of the protection material for filed of the army by impact of fragment from the explosion of 155mm artillery shell to propose the improvement items. And it was evaluated the protection materials for structural boby such as corrugated steel plate, concrete block, prevention paint of explosion, aluminum foam and concrete T-wall by impact of fragment of 155mm artillery shells and explosion-induced pressure of C-4 explosive. As a result, protective performance of the existing protective material was superior but reinforcement is necessary for secondary damage because sand is leaking. The protective performance of new protective materials was greater than existing protective materials. And it can be used for protective materials.

섬유보강 콘크리트 방호벽의 방호성능 향상 검토 (Evaluation of Protective Performance of Fiber Reinforced Concrete T-Wall)

  • 이인철;김홍섭;남정수;김석봉;김규용
    • 한국건축시공학회지
    • /
    • 제13권5호
    • /
    • pp.465-473
    • /
    • 2013
  • 콘크리트는 충격 및 폭발에 대한 저항능력이 우수한 재료이지만, 국부적인 파괴가 발생하는 한계가 있다. 콘크리트의 방호성능 향상기법은 기존에는 부재의 두께를 증가시키는 것이었으나, 이는 공간의 활용에 있어 비효율 적이다. 최근에는 섬유보강 콘크리트는 콘크리트 자체의 휨인성을 증가시켜, 충격 및 폭발에 대한 저항능력을 향상시킨 방호재료의 개발 및 적용이 고려되고 있다. 본 연구에서는 섬유보강 콘크리트 및 모르타르에 대하여 고속 비상체의 충돌에 의한 내충격 성능을 평가하였으며, 그 결과를 바탕으로 방호벽으로 활용할 수 있는 콘크리트 T-wall을 제작하여 155 mm 포탄의 파편에 대한 방호성능을 검토하였다. 그 결과, 섬유보강으로 인한 휨 인성의 향상은 고속 비상체의 충돌에 의한 배면박리를 억제하는 것으로 나타났으며 155 mm 포탄의 파편 충돌에 있어 배면균열 및 표면의 콘크리트의 박락 등이 억제되어 섬유보강으로 인하여 방호벽의 성능 향상 및 부재두께를 감소할 수 있을 것으로 판단된다.

비노출 방수층에 작용하는 정하중과 동하중 작용 후의 방수층 물성변화에 관한 연구 (A Study on the Change of Physical Capability of Waterproofing Layer after the Application of Static Load and Moving Load to a Non-Exposed Type Waterproofing Layer)

  • 선윤숙;김진성;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2007년도 춘계학술논문 발표대회
    • /
    • pp.141-145
    • /
    • 2007
  • The part in the structure that is most affected by changes of external temperature is the protective concrete layer that protects a waterproofing layer. Also, the waterproofing layer that is situated under or on the back of such a protective concrete layer is affected by temperature and the behavior of the protective concrete layer under the condition of consolidation or close adhesion. In particular, in many cases, the damage is serious mainly around the projection (such as a parapet), crack, and joint (expansion joint). However, there is no proper way of examining again the non-exposed waterproofing layer once it has been constructed. Therefore, there is an assessment only on the physical property of materials and the capability of the layer in construction, and there is no actual assessment in consideration of its environmental condition or the condition of the use of buildings after construction. Therefore, in order to create more pleasant buildings and to enhance the durability of structures, this study conducts research into the change of capability of non-exposed waterproofing material after the application of a static load and moving load on the waterproofing layer situated under or on the back of protective concrete.

  • PDF

Silicate계 콘크리트 함침제 도포에 따른 부착특성 및 공극변화 (Adhesion Characteristic and Porosity Change of Alkali Silicate Impregnant of Concrete)

  • 송훈;추용식;이종규;임영철
    • 한국세라믹학회지
    • /
    • 제47권4호
    • /
    • pp.276-282
    • /
    • 2010
  • There are the impregnating layer formation by surface protective materials or impregnants and the adhesion method by polymer, FRP sheet or steel plate in the surface protective method of concrete structure. The surface impregnation method by impregnants improves the durability of concrete structure by modifying the structure of the concrete surface and also have a merit that can be shortly applied in place without the decrease of concrete surface appearance and is easily applied again. This study is interested in manufacturing the concrete surface impregnants including lithium and potassium silicate for the repair of the exposed concrete and the color concrete requiring the advanced function in view of the concrete appearance. The durability and porosity properties was tested for the review of application. The result of this study show that the effective content of silicate ranges 5 to 20% and the separate application of the first impregnant and the second impregnant is effective for the optimum performance. The adhesion in tension is slightly increased but the reinforcement of concrete substrate is slight. So, the concrete impregnant of this study is more desirable for the improvement of durability rather than the reinforcement.

Bonding between high strength rebar and reactive powder concrete

  • Deng, Zong-Cai;Jumbe, R. Daud;Yuan, Chang-Xing
    • Computers and Concrete
    • /
    • 제13권3호
    • /
    • pp.411-421
    • /
    • 2014
  • A central pullout test was conducted to investigate the bonding properties between high strength rebar and reactive powder concrete (RPC), which covered ultimate pullout load, ultimate bonding stress, free end initial slip, free end slip at peak load, and load-slip curve characteristics. The effects of varying rebar buried length, thickness of protective layer and diameter of rebars on the bonding properties were studied, and how to determine the minimum thickness of protective layer and critical anchorage length was suggested according the test results. The results prove that: 1) Ultimate pull out load and free end initial slip load increases with increase in buried length, while ultimate bonding stress and slip corresponding to the peak load reduces. When buried length is increased from 3d to 4d(d is the diameter of rebar), after peak load, the load-slip curve descending segment declines faster, but later the load rises again exceeding the first peak load. When buried length reaches 5d, rebar pull fracture occurs. 2) As thickness of protective layer increases, the ultimate pull out load, ultimate bond stress, free end initial slip load and the slip corresponding to the peak load increase, and the descending section of the curve becomes gentle. The recommended minimum thickness of protective layer for plate type members should be the greater value between d and 10 mm, and for beams or columns the greater value between d and 15 mm. 3) Increasing the diameter of HRB500 rebars leads to a gentle slope in the descending segment of the pullout curve. 4) The bonding properties between high strength steel HRB500 and RPC is very good. The suggested buried length for test determining bonding strength between high strength rebars and RPC is 4d and a formula to calculate the critical anchorage length is established. The relationships between ultimate bonding stress and thickness of protective layer or the buried length was obtained.

철근콘크리트조 박스형 포상의 방호성능 평가 (The Study on Assessment of Protective Capacity of the Reinforced Concrete Box-type Artillery Positions)

  • 백종혁;김석봉;손기영;박영준
    • 한국군사과학기술학회지
    • /
    • 제17권2호
    • /
    • pp.275-281
    • /
    • 2014
  • Although self-propelled artilleries are mobile equipment, they need their own covered-positions for survival against preemptive strikes. The most important military requirement is enough protective capacity against blast pressure caused by explosion. This paper aims to assess the protective capacity of the newly-placed concrete box-type artillery positions using accurate structural geometric models as well as soil-structure interaction analysis. The commercial program is used to model the structural geometry of the positions. In order to describe the correct wave propagation in the backfill along with soil-structure interaction, used parameters in shock equation of state are selected based on the related studies as well as theories and then their final results are verified with the ones calculated with empirical equations in the US Unified Facility Criteria. In sum, it could be concluded that the protective capacity of the newly-built positions satisfies the protective structural requirement.

해양환경에 3년간 노출시킨 콘크리트 표면도장재료의 내구성 평가 (Durability of Protective Surface Coatings Exposed in Marine Environment for 3 Years)

  • 정해문;안태송;신도철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(II)
    • /
    • pp.229-232
    • /
    • 2005
  • Protective surface coating for concrete is available for applying to concrete structures for protecting chloride attack. However, the useful data obtained from real marine environment for surface coating materials is not sufficient yet in Korea and thus the engineers face many difficulties to apply the coating method in durability design. Surface-coated concrete specimens were fabricated and installed around the piers of Seohae grand bridge to observe long-term performance in actual marine environment. In this study, the results of durability of surface coatings for 3 years were reported.

  • PDF

The Research and Application of Protective Coating for PCCP

  • Lin, Zhu;Xu, Cuizhu;Zhang, Li;Fan, Yunpeng;Zhang, Qibin
    • Corrosion Science and Technology
    • /
    • 제7권5호
    • /
    • pp.265-268
    • /
    • 2008
  • Prestressed Concrete Cylinder Pipe(PCCP) had became one of the dominating kinds of pipes substituting for steel pipes because of its unique feature (high intensity, high pressure and high leakproofness). PCCP was produced firstly by Bonna company in France. By the end of 20th century, there were over 19000 km of this product installed in America. PCCP was introduced from Ameron company by Shandong Eletric Power Pipeline Engineering Company in 1988. As the statistical data in 2002, 700 km of PCCP had been applied in China, and the application trended towards rapid increase.Since prestressing wire would be corroded in environment, Several accidents due to the breakdown of pipe had happened. Consequently the external wall of pipe should be covered with protective coatings. There was a lack of technical study in corrosion and control of PCCP, because PCCP had been applied for a short time in China. in order to ensure the service life of PCCP, we have developed a kind of protective coating for concrete pipe, which had high intensity and anti-corrosive property with convenient applicability. The physical and chemical properties, painting technology and field application of this coating was introduced in the paper, at the same time, the future of external protective coating for PCCP was looked into.