• Title/Summary/Keyword: Protective Film

Search Result 259, Processing Time 0.031 seconds

A Study on the Environmental Condition and Safety in Dental Radiography Room (치과방사선 촬영실의 환경 및 안전성에 관한 연구)

  • Park, Il-Soon;Lee, Kyung-Hee
    • Journal of Korean society of Dental Hygiene
    • /
    • v.4 no.1
    • /
    • pp.49-64
    • /
    • 2004
  • This study is designed to conduct a questionnaire research into the safety control and the actual condition of radiography by working with dentistry belonging to university hospitals, dental hospitals and dental clinics for three months ranging from August, 2003 to October, 2003. The researcher came to the following conclusions. 1. The research on the current condition of possessed radiational equipment shows that 61.2 percent of the subjects had one intraoral radiation medicine and that 70.1 percent of the subjects had more than one extraoral radiation medicine and that 37.3 percent of the subjects had more than one digital radiation medicine. 2. Most of intraoral radiography (82.1%) was conducted by dental hygienists, and 7.5 percent of intraoral radiography was conducted by nurse aids. On the other hand, most of extraoral radiography (76.6%) was conducted by dental hygienists and digital radiography was conducted by dental hygienists(60.6%), dentists(32.0%) and radiographer(80.0%). 3. The less-than 1-meter-long distance between cone and the radiographer accounted for 44.8 percent. And the more-than 1.6-meter-long distance accounted for no more than 13.4 percent. The exposure time per standard film which was adjusted to each part accounted for 71.6 percent. Fixing the film on the part of healthy patients accounted for 76.1 percent. Fixing the film of elderly patients and children patients by the radiographer accounted for 43.3 percent. 4. The average daily photographing frequency of standard films stood at six to ten pieces(31.3%), and the average weekly photographing frequency of bitewing films stood at less than one piece(47.8%), and the dentistries where bitewing films were not employed accounted for 25.4%. The subjects whose average weekly photographing freqeuncy of occlusal films stood at less than a piece accounted for 59.7 percent. The dentistries whose average weekly photographing frequency of pediatric films stood at one to five pieces accounted for 41.8 percent. In case of panorama & cephalo, one to five pieces on a weekly average accounted for 36.2 percent. The dentistries whose average daily photographing frequency of digital radiation medicine stood at less than 1 piece accounted for 40.0 percent. 5. The research on the use of protective clothes shows that pregnant ·women only accounted for 31.3 percent. In regard to the use of protective clothes in case of the radiographers fixing films, the cases where no protective clothes were employed accounted for 88.1 percent. The reason was said to he attributable to the trouble related to wearing the clothes(54.2%). 6. The survey on the measurement of exposure dose shows that the cases where no measurement was made accounted for 76.1 percent. As far as the measurement methods of exposure dose was concerned, the employment of film badge accounted for 68.8 percent. The subjects turned out to conduct measurement of exposure dose every third month, which accounted for 43.8 percent. The barriers to the measurement of measurement of exposure dose were attributable to the recognition that a little amount of exposure dose need not be measured(29.9%). 7. The survey on the distinction of radiation rooms and clinic rooms reveals that the cases where radiation rooms exclusively existed accounted for 67.2 percent. 43.3 percent of the subjects turned out to have only one protective garment, and 49.3 percent of the subjects proved to conduct a periodical checkup of radiational equipment. The survey on the examination certificates of radiational generators and protective facilities indicates that 80.6 percent of the subjects had the certificates. The research also shows that the subjects with the marks indicating the radiational areas accounted for 70.1 percent. And trustees turned out to handle developing solutions and fixing solutions.

  • PDF

The Effect of Multilayer Passivation Film on Life Time Characteristics of OLED Device (OLED소자의 수명에 미치는 다층 보호막의 영향)

  • Ju, Sung-Hoo;Yang, Jae-Woong
    • Journal of Surface Science and Engineering
    • /
    • v.45 no.1
    • /
    • pp.20-24
    • /
    • 2012
  • Multilayer passivation film on OLED with organic/inorganic hybrid structure as to diminish the thermal stress and expansion was researched to protect device from the direct damage of $O_2$ and $H_2O$ and improve life time characteristics. Red OLED doped with 1 vol.% Rubrene in $Alq_3$ was used as a basic device. The films consist of ITO(150 nm)/ELM200_HIL(50 nm)/ELM002_HTL(30 nm)/$Alq_3$: 1 vol.% Rubrene(30 nm)/$Alq_3$(30 nm) and LiF(0.7 nm)/Al(100 nm) which were formed in that order. Using LiF/$SiN_x$ as a buffer layer was determined because it significantly improved life time characteristics without suffering damage in the process of forming passivation film. Multilayer passivation film on buffer layer didn't produce much change in current efficiency, while the half life time at 1,000 $cd/m^2$ of OLED/LiF/$SiN_x$/E1/$SiN_x$ was 710 hours which showed about 1.5 times longer than OLED/LiF/$SiN_x$/E1 with 498 hours. futhermore, OLED/LiF/$SiN_x$/E1/$SiN_x$/E1/$SiN_x$ with 1301 hours showed about twice than OLED/LiF/$SiN_x$/E1/$SiN_x$ which demonstrated that superior characteristics of life time was obtained in multilayer passivation film. Through the above result, it was suggested using LiF/$SiN_x$ as a buffer layer could reduce the damage from the difference of thermal expansion coefficient in OLED with protective films, and epoxy layer in multilayer passivation film could function like a buffer between $SiN_x$ inorganic layers with relatively large thermal stress.

Effect of Pre-Cycling Rate on the Passivating Ability of Surface Films on Li4Ti5O12 Electrodes

  • Jung, Jiwon;Hah, Hoe Jin;Lee, Tae jin;Lee, Jae Gil;Lee, Jeong Beom;Kim, Jongjung;Soon, Jiyong;Ryu, Ji Heon;Kim, Jae Jeong;Oh, Seung M.
    • Journal of Electrochemical Science and Technology
    • /
    • v.8 no.1
    • /
    • pp.15-24
    • /
    • 2017
  • A comparative study was performed on the passivating abilities of surface films generated on lithium titanate (LTO; $Li_4Ti_5O_{12}$) electrodes during pre-cycling at two different rates. The surface film deposited at a faster pre-cycling rate (i.e., 0.5 C) is irregularly shaped and unevenly covers the LTO electrode. Owing to the incomplete coverage of the protective film, this LTO electrode exhibits poor passivating ability. Additional electrolyte decomposition and concomitant film deposition occur during subsequent charge/discharge cycles. As a result of the thick surface film, severe cell polarization occurs and eventually causes cell failure. However, pre-cycling the Li/LTO cell at a slower rate (0.1 C) improves cell polarization and capacity retention; this occurs because the surface film uniformly covers the LTO electrode and provides strong passivation. Accordingly, there is no significant film deposition during subsequent charge/discharge cycling. Additionally, self-discharge is reduced during high-temperature storage.

The relationships between the MgO crystal orientation and the conditions of deposition on AC-PDP (AC PDP의 MgO 결정방향성과 증착조건간의 상관관계에 관한 연구)

  • Jang, Jin-Ho;Jang, Yong-Min;Lee, Ji-Hoon;Cho, Sung-Yong;Kim, Dong-Hyun;Park, Chung-Hoo
    • Proceedings of the KIEE Conference
    • /
    • 2006.10a
    • /
    • pp.202-203
    • /
    • 2006
  • In the AC PDP, the MgO film is used as electrode protective film. This film must provide excellent ion bombardment protection, high secondary electron emission, and should be high transparent to visible radiation. In this study, we investigated the relations between the crystal orientation and e-beam evaporation process parameters. The crystal orientation of the MgO layer depends on the conditions of deposition. The parameters are the thickness of the MgO film $1000{\AA}-6500{\AA}$, the deposition rate $200{\AA}/min{\sim}440{\AA}/min$, the temperature $150^{\circ}C{\sim}250^{\circ}C$, and the distance between crucible and substrate 11cm ${\sim}$ 14cm. The temperature of substrate and evaporation rate of source material, or deposition rate of the film, are definitely related to the crystal orientation of the MgO thin film. The crystal orientation can be changed by the distance between the target(MgO tablet) and the substrate. However, the crystal orientation is not much affected by the thickness of MgO thin film.

  • PDF

A Study on Wearing Test of Protective Clothing against a Toxic Substance (유해물질 차단을 위한 방호복의 착용실험에 관한 연구)

  • Chung, Myung-Hee;Park, Soon-Ja;Shin, Jung-Sook;Koshiba, Tomoko;Tamura, Teruko
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.30 no.11 s.158
    • /
    • pp.1626-1635
    • /
    • 2006
  • The purpose of this study was to search for comfortable protective clothing for waste incinerator workers. The experimental protective clothing came in two types: one whose outer side made use of polypropylene film, and the inner side, a non-woven rayon fabric processed with charcoal with a 10% density (CF): and one whose outer side made use of polyolefine and polyamide films, and the inner side, a non-woven polypropylene fabric (NNCF). Experiments were conducted on five healthy adult women whose average age was 21. These experiments were conducted at a climate chamber, in which the temperature and relative humidity were set below $28{\pm}1^{\circ}C\;and\;50{\pm}10%$, respectively. Measured were the rectal temperature, the skin temperature, the sweating rate, the weight loss, the heart rate, the blood pressure, the temperature, and the relative humidity of a microclimate and subjective sensation. These were measured within a period of 60 min, consisting of a 20-min stable period, a 20-min exercise period (walking exercise for 2 miles/hr on a treadmill), and a 20-min recovery period. Through this experiment, the differences between the human body's physiological reactions to CF and NNCF clothing, and the human body's comfort levels when wearing these, were determined.

Evaluation of Physiological Responses and Comfort of Protective Clothing Using Charcoal Printing (숯 날염가공한 방호복의 인체생리반응 및 쾌적성 평가)

  • Chung Myung-Hee;Park Soon-Ja;Shin Jung-Sook;Koshiba Tomoko;Tamura Teruko
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.30 no.6 s.154
    • /
    • pp.981-991
    • /
    • 2006
  • The purpose of this study was to determine the practicability of an experimental protective clothing by identifying the human body's physiological responses to it as well as the human body's comfort level when wearing it, particularly with the use of a processed charcoal material. The experimental protective clothing came in two types: one whose outer side made use of polypropylene film, and the inner side, a non-woven rayon fabric; and one whose inner side made use of a non-woven fabric processed with charcoal with a 10% density. Experiments were conducted on five healthy adult women whose average age was 21. These experiments were conducted at a climatic chamber, in which the temperature and relative humidity were set below $28{\pm}1^{\circ}C\;and\;50{\pm}10%$, respectively, and were measured within a period of 60min, consisting of a 20-min rest period, a 20-min exercise period, and a 20-min recovery period. Based on the results of this study, the efficiency of the processed charcoal material was reviewed, and a database requiring the production of more functional and comfortable protective clothing materials was established.

Preparation of MgO Protective layer by reactive magnetron Sputtering (반응성 스퍼트링에 의한 MgO 유전체 보호층 형성에 관한 연구)

  • Ha, H. J.;Lee, W. G.;Ryu, J. H.;Song, Y.;Cho, J. S.;Park, C. H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.05a
    • /
    • pp.59-62
    • /
    • 1996
  • Plasma displays (PDP) as a large area wall-hanging display device are rabidly developed with flat CRT, TPT LCD and etc. Especially, AC Plasma Display Panels(AC PDPs) have the inherent memory function which is effective for large area displays. The memory function in AC PDPs is caused by the accumulation of the electrical charge on the protecting layer formed on the dielectric layer. This MgO protective layer prevents the dielectric layer from sputtering by ion in discharge plasma and also has the additional important roll in lowering the firing voltage due to the large secondary electron emission coefficient). Until now, the MgO Protective layer is mainly formed by E-Beam evaporation. With increasing the panel size, this process is difficult to attain cost reduction, and are not suitable for large quantity of production. To the contrary, the methode of shuttering are easy to apply on mass production and to enlarge the size of the panel and shows the superior adhesion and uniformity of thin film. In this study, we have prepared MgO protective layer on AC PDP Cell by reactive magnetron sputtering and studied the effect of MgO layer on the surface discharge characteristics of ac PDP.

  • PDF

Low-voltage characteristics of E-beam evaporated MgO-CaO films as a protective layer for AC PDPs (전자빔 증착법으로 증착한 MgO-CaO 박막의 교류형 PDP 보호막 적용을 위한 저전압 특성 연구)

  • 조진희;김락환;이경우;김정열;김희재;박종완
    • Journal of the Korean Vacuum Society
    • /
    • v.8 no.1
    • /
    • pp.70-74
    • /
    • 1999
  • MgO-CaO protective layers with various composition were prepared by electron beam evaporation to improve the characteristics of conventional pure MgO thin films as a protective layer for AC-PDP. The maximum deposition rate of pure MgO was 1025 $\AA$/min and decreased with increasing [(CaO/(MgO+CaO)] ratio of evaporation starting materials. From XRD analyses, a trend of peak shift to the lower 2$\theta$ angle side was shown as CaO content increased and it stoped when the concentration of CaO was 0.13, which corresponds to the maximum solubility of CaO in MgO. The optimum composition of the protective thin films was Mg 47.1 at%, Ca 1.3 at%, O 51.6 at%, and firing voltage, memory margin and deposition rate of the film with this composition was 176 V, 0.5 and 515 $\AA$/min, respectively.

  • PDF

A Study on Impact Damage Characteristics of the Window Glass for High Speed Train (고속열차 객실 유리창 충격파손특성 비교 연구)

  • Jeon, Chang-Sung;Kim, Young-Guk;Yun, Su-Hwan;Kwon, Hyeok-Bin;Park, Tae-Won
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.3
    • /
    • pp.217-223
    • /
    • 2012
  • This study describes an experimental investigation about the impact damage characteristics of various types of high speed train window glass. Kinds of impact test standards for glass were studied and impact test considering scattering ballast were developed. Windows with external impact side made with annealed, heat strengthened and tempered glasses are likely to be broken by sharp tipped falling object. Broken shape of annealed glass is like line in part and that of heat strengthened glass is line on the whole. Tempered glass is destroyed to pieces. The change of tip type from sharp to blunt makes the higher destroyed level. Tempered glass has higher strength than annealed glass with blunt tip. When the protective films are attached to glasses, strength against destruction increases. In case of real ballast test, glasses without protective films were destroyed, but those with protective films are hard to be broken.

Evaluation of Antioxidant Potential and UV Protective Properties of Four Bacterial Pigments

  • Rupali Koshti;Ashish Jagtap;Domnic Noronha;Shivali Patkar;Jennifer Nazareth;Ruby Paulose;Avik Chakraborty;Pampi Chakraborty
    • Microbiology and Biotechnology Letters
    • /
    • v.50 no.3
    • /
    • pp.375-386
    • /
    • 2022
  • In the present study, four distinctly colored bacterial isolates that show intense pigmentation upon brief ultraviolet (UV) light exposure are chosen. The strains are identified as Micrococcus luteus (Milky yellow), Cryseobacterium pallidum (Yellow), Cryseobacterium spp. (Golden yellow), and Kocuria turfanensis (Pink) based on their morphological and 16S rDNA analysis. Moderate salinity (1.25%), 25-37℃ temperature, and pH of 7.2 are found to be the most favorable conditions of growth and pigment production for all the selected isolates. The pigments are extracted using methanol: chloroform (1:1) and the purity of the pigments are confirmed by high-performance liquid chromatography (HPLC) and thin-layer chromatography (TLC). Further, Fourier transform infrared (FTIR) and UV-Visible spectroscopy indicate their resemblance with carotenoids and flexirubin family. The antioxidant activities of the pigments are estimated, and, all the pigments have shown significant antioxidant efficacy in 2,2'-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid) (ABTS), 2,2-diphenyl-1-picryl-hydrazyl (DPPH), and ferric reducing antioxidant power (FRAP) assays. The UV protective property of the pigments is determined by cling-film assay, wherein, at least 25% of UV sensitive Escherichia coli survive with bio-pigments even after 90 seconds of UV exposure compared to control. The pigments also hold a good sun protective factor (SPF) value (1.5-4.9) which is calculated with the Mansur equation. Based on these results, it can be predicted that these bacterial pigments can be further developed into a promising antioxidant and UV-protectant for several biomedical applications.