• 제목/요약/키워드: Protection against lightning

검색결과 67건 처리시간 0.026초

가정용 전기기구의 효과적인 뇌서지 보호기법 (Effective Protection Methods of Household Electric Appliances. from Lightning Surges)

  • 이복희;강성만;엄주홍;이수봉;길형준;구본완;안창환
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권3호
    • /
    • pp.149-156
    • /
    • 2004
  • This paper deals with the effective protection method for the household electric appliances against lightning surges invading from the Power lines. Direct or induced lightning is the main cause of the breakdown of household electric appliance. The most effective protection method is to install SPDs(surge protective devices) at household electric appliances. If SPDs were not installed at most household electric appliances, it is necessary to install SPDs on the mains. Therefore the propagation aspect and protection methods of lighting surges coming into household electric appliances through the mains was experimentally investigated. The in actual-sized test circuits results of protection method for 8 household electric appliances including computer monitors and TV set could be summarized as follows: The breakdown characteristics of household electric appliances from lightning surges were significantly changed with the their input impedance. Namely, the types of input impedance are classified into infinite, resistive or inductive impedances. Especially, the monitor for computer with inductive input impedance from lightning surges was relatively weak against lightning surges. It was confirmed that the self inductance of branch circuits on the mains have protection effect for household electric appliances against lightning surges invading from the power lines. Also the varistors installed at cabinet panel or circuit-breaker were more effective than multi-tap outlet with varistors. When installed varistors in cabinet panel and multi-tap outlet together, the surge protection effect is much more excellent in technical and economical aspects.

높이 20미터 미만인 구조물의 낙뢰리스크 평가 (Lightning Risk Assessment for Structures Lower than 20m High)

  • 이주철;김기현;이영철
    • 조명전기설비학회논문지
    • /
    • 제26권12호
    • /
    • pp.21-27
    • /
    • 2012
  • Korean Industrial Standards for lightning protection system complies with IEC standards. However, the standards are applicable only to buildings and structures more than 20 meters in high. Therefore, it is necessary to determine whether lightning protection system should be installed on structures lower than 20 meters high. This paper proposes an efficient method of assessing risk against lightning of structures lower than 20 meters high. The method suggests simplified lightning protection system and provides selecting an appropriate protection level. The suggested method assumes that structure under assessment has no lightning protection system and there is no person around the structure at the moment of lightning stroke. A simplified method of assessing the risk to human within the structure is developed by adopting the general assessment factor. The selection of a protection level is possible by comparing tolerable risk with physical damage risk caused by a direct lightning. Finally, this paper gives ways to establish surge protection measures when a structure with lightning risk is within a radius of 2km from the assessed structure even if this structure requires no lightning protection system.

저압수용가에 공급하는 TT, TN계통의 뇌서지에 대한 보호성능의 평가 (Evaluation of the Protection Performance of TT and TN Systems for Low-Voltage Consumers Against Lightning Surges)

  • 이규선;최종혁;이복희
    • 조명전기설비학회논문지
    • /
    • 제24권6호
    • /
    • pp.67-74
    • /
    • 2010
  • 국내의 저압수용가 대부분은 한국전력공사의 TN-C접지방식으로부터 공급받고 있으나 부하설비는 TT 접지방식을 위주로 한 전기설비기술기준에 따라 시설되어 있다. 본 연구에서는 정보기술설비를 뇌서지로부터 보호할 수 있는 적절한 전원계통접지방식을 제안하기 위해서 TT, TN계통의 뇌서지에 대한 보호성능을 연구하였다. 그 결과, 뇌서지가 배전계통의 중성선에 입사한 때 TT계통의 기기접지단자와 전원선의 중성점 사이에 높은 전위차가 발생하였으며, 예민한 컴퓨터설비가 손상될 위험성이 있으므로 TT계통은 적합하지 않다. 뇌서지로부터 저압 설비를 보호하기 위해서는 등전위본딩이 중요한 요건이며, TN계통이 중성선을 통하여 입사하는 뇌서지의 저감에 가장 우수하였으며, 수용가 인입구에서의 추가접지도 바람직한 방법이다.

지중배전계통의 뇌과전압 해석 및 뇌써지 보호방안에 관한 연구 (A Study on the Lightning Overvoltage Analysis and Lightning Surge Protection Methods in Underground Distribution System)

  • 김상국;정채균;이종범;하동혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.558-560
    • /
    • 2003
  • The effects of surge arresters for protection of transmission systems against direct lightning strokes have already been investigated using the digital simulation program EMTP. Distribution lines are spanned on a much large area as compared to transmission lines, and therefore, are more often susceptible to lightning strokes. This paper analyzes the overvoltages on underground cable system against direct lightning strokes to the overhead ground wire using the digital simulation. The effects of lightning protection methods, such as lowering the grounding resistance and installing the surge arrester, for preventing overvoltages on underground cable system caused by direct lightning strokes to the overhead ground wire is investigated. Several schemes have been proposed to protect underground cables. This paper summarizes the main results of a study aimed at analysis of lightning overvoltages in variety underground feeders protected by metal-oxide arresters. This study will provide insulation coordination methods for reasonable system design in 22.9kV underground cable system.

  • PDF

A Protection Technique Against the Damages Caused by Lightning Surges on Information and Communication Facilities

  • Lee, Bok-Hee;Kang, Sung-Man;Ahn, Chang-Hwan
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제3C권4호
    • /
    • pp.117-122
    • /
    • 2003
  • The AC power lines and signal lines of info-communication networks are routed on overhead poles and are highly exposed to lightning strikes. Due to the potential difference between grounding points of AC power lines and signal lines, the electronic equipments connected to the signal lines can easily be damaged by lightning surges. In this work, in order to develop reliable methods of protecting information and communication facilities from lightning surges, the reliability and performance of SPDs (surge protective devices) were experimentally investigated in an actual-sized test circuit. The behaviors of SPDs against lightning surges from AC power lines and signal lines and the coordinated effects of SPD installation methods were evaluated. As a consequence, it was confirmed that the bypass arrester methods and common grounding system are both highly effective.

낙뢰보호를 고려한 항공기용 다목적 디스플레이 설계 (Considering the Multi-Purpose Display Designed for Aircraft Lightning Protection)

  • 천영호;이승필;박준현
    • 한국항행학회논문지
    • /
    • 제18권5호
    • /
    • pp.445-454
    • /
    • 2014
  • 본 논문에서는 다목적 디스플레이의 인증 과정에서 수행 했던 시험 중 간접 낙뢰의 영향성을 검증하기 위한 RTCA DO-160 F, Section 22 시험 수행을 위한 대책 설계 내용 및 시험 과정을 소개한다. 낙뢰 유도 전압은 항공기 전기 전자장비의 기능 장애또는 손상을 가져다 주는 데 이것을 낙뢰의 간접영향이라 한다. 이러한 항공기의 낙뢰 간접영향으로부터 항공전자장비를 보호하기 위해서는 항공기에 대한 낙뢰의 영향과 항공기 내부 시스템을 분석하고 해당 부품에 대한 위협 내용에 대한 보호 설계가 필요하다. 본 논문에서는 이와 같은 항공기용 다목적 디스플레이의 낙뢰에 대한 보호를 위하여 대책 수준을 결정을 위한 RTCA DO-160 F, Section 22 category 선정 방법 및 선정된 레벨에 따른 부품 선정 방법 등을 소개한다. 또한 선정된 부품의 설계 유효성을 확인하기 위하여 실제 시험 과정을 소개한다. 이와 같은 각 단계별 과정 소개를 통하여 향후 개발 예정인 항공전자 장비에 대한 낙뢰 대책 설계의 좋은 사례가 될 것으로 예상한다.

정밀기기의 낙뢰서지 대책에 관한 연구 (Protecting electronic equipment against lightning surge)

  • 임순재;이주광;이완규;최만용
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 춘계학술대회 논문집
    • /
    • pp.358-362
    • /
    • 1995
  • Precision electronic equipments are composed of sophisticated microcircuits that are extremely vulnerable to lightning-caused voltage spike. This transient voltage spike may cause upset, latent failure or interference on electronic equipments. In order to develop efficient lightning protection measures on AC power lines for a road traffic controller, experimental surge immunity tests were conducted according to IEC standard 801-5. The combination of gas tube arrester and metal-oxide varistor was installed at the input of AC power lines and the silicon avalanche suppressor installed at the output of DC power supply as lightning protection measures.

  • PDF

뇌해방지를 위한 레이저 유도뢰에 관한 기초적 연구 (Basic Research of Laser Triggered Lightning for a Protection of Lightning)

  • 장용무;강형부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1568-1570
    • /
    • 1994
  • Laser-triggered-lightning is protection methed for power apparatus against lightning. It is necessary to understand the generation mechanism of laser produced plasma. So production of long distance laser-plasma-channel was numerically analyzed with electron growth equation and laser transport equation.

  • PDF

복합재항공기 연료시스템의 낙뢰보호설계 및 인증 연구 (Research on Aircraft Lightning Protection Design and Certification of Fuel System in Composite Material)

  • 이영제;조원일;전정환;고진환
    • 한국항공운항학회지
    • /
    • 제25권4호
    • /
    • pp.130-140
    • /
    • 2017
  • Lightning protective design of an aircraft fuel system is closely related to the safety of the flight. Recently, composite material in building an aircraft becomes more important because it can reduce the weight of the aircraft. The composite materials decrease the protection against the effect of lightning. Lightning protective design of metal material aircraft has been researched for a long time and the design technique has been announced widely. However, research on the lightning protective design using composite material aircraft is very limited. In this study, lightning protective design for fuel tank structural component, access cover, fuel filler cap and drain valve in carbon fiber composite material aircraft have been presented. To show the compliance with FAA airworthiness standard regarding the presented protection designs, three steps, including lightning strike analysis, lightning environment analysis and certification test, were conducted in accordance with FAA AC 20-53.

22.9kV 지중계통의 뇌과전압 해석 및 뇌서지 보호방안에 관한 연구 (A Study on the Lightning Overvoltage Analysis and Lightning Surge Protection Methods in 22.9kV Underground Distribution Systems)

  • 김상국;정채균;이종범;박왈서
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권8호
    • /
    • pp.454-460
    • /
    • 2004
  • The effects of surge arresters for protection of transmission systems against direct lightning strokes have already been reviewed using Electromagnetic Transients Program(EMTP). Distribution lines are spanned in much larger area than transmission lines, and therefore, are more susceptible to lightning strokes. We have modelled the 22.9kV underground distribution cable systems that have arresters and grounding wires. And this paper analyzes the overvoltages on underground distribution cable systems when direct lightning strokes strike on the overhead grounding wire using EMTP. Then we investigated that (1) the effects of lightning stroke according to underground distribution cable length (2) voltages at the riser pole and at the cable terminal according to installation of arrester. This study will provide insulation coordination methods for reasonable systems design in 22.9kV underground distribution cable systems.