• Title/Summary/Keyword: Protection Standards

Search Result 679, Processing Time 0.028 seconds

Evaluating the Protective Effectiveness of Rubber Glove Materials Against Organic Solvents Upon Repeated Exposure and Decontamination

  • Li-Wen Liu;Cheng-Ping Chang;Yu-Wen Lin;Wei-Ming Chu
    • Safety and Health at Work
    • /
    • v.15 no.2
    • /
    • pp.228-235
    • /
    • 2024
  • Background: Glove reuse poses risks, as chemicals can persist even after cleaning. Decontamination methods like thermal aeration, recommended by US OSHA, vary in effectiveness. Some studies show promising results, while others emphasize the importance of considering both permeation and tensile strength changes. This research advocates for informed glove reuse, emphasizing optimal thermal aeration temperatures and providing evidence to guide users in maintaining protection efficiency. Methods: The investigation evaluated Neoprene and Nitrile gloves (22 mils). Permeation tests with toluene and acetone adhered to American Society for Testing Materials (ASTM) F739 standards. Decontamination optimization involved aeration at various temperatures. The experiment proceeded with a maximum of 22 re-exposure cycles. Tensile strength and elongation were assessed following ASTM D 412 protocols. Breakthrough time differences were statistically analyzed using t-test and ANOVA. Results: At room temperature, glove residuals decreased, and standardized breakthrough time (SBT)2 was significantly lower than SBT1, indicating reduced protection. Higher temperature decontamination accelerated residual removal, with ∆SBT (SBT2/SBT1) exceeding 100%, signifying restored protection. Tensile tests showed stable neoprene properties postdecontamination. Results underscore thermal aeration's efficacy for gloves reuse, emphasizing temperature's pivotal role. Findings recommend meticulous management strategies, especially post-breakthrough, to uphold glove-protective performance. Conclusions: Thermal aeration at 100℃ for 1 hour proves effective, restoring protection without compromising glove strength. The study, covering twenty cycles, suggests safe glove reuse with proper decontamination, reducing costs significantly. However, limitations in chemical-glove combinations and exclusive focus on specific gloves caution against broad generalization. The absence of regulatory directives on glove reuse highlight the importance of informed selection and rigorous decontamination validation for workplace safety practices.

Effects of Special Protection Area Designation on Soil Properties and Vegetation Coverage of Degraded Trails (국립공원 특별보호구 지정이 훼손 탐방로 주변 토양과 식생피도에 미치는 영향)

  • Kim, Dong-Hwan;Lee, Dong-Ho;Kim, Hyun Seok;Kim, Seong-il
    • Journal of Korean Society of Forest Science
    • /
    • v.104 no.3
    • /
    • pp.352-359
    • /
    • 2015
  • This study was conducted to evaluate how the special protection area designations of degraded trails effect on the soil and vegetation recovery of degraded trails. The study areas were established on an opened trail and a 16-year closed trail, which was prohibited to enter after the designation as a special protection area for recovery, at Bukhansan National Park. Soil core sampling and measurements of vegetation cover were performed to compare soil and vegetation properties of the trails. Soil bulk density increased and soil water total nitrogen decreased on the opened trail, while no significant differences were found on bulk density, soil water, total nitrogen, acidity, and organic matter on the closed trail. On the opened trail, vegetation cover was seemed to be degraded, because vegetation litter cover ratio was low and barren rock cover ratio was high. On the closed trail, litter rock barren cover ratio of the closed trail was recovered, but only limited recovery was found on vegetation cover by applying environmental damage condition rating class. In conclusion, the closed trail was recovered by designation of special protection area, while difference in recovery progress of soil and vegetation was found. Therefore, designation of special protection area of degraded area should be based on scientific basis of recovery characteristics of the area. In order to improve the effectiveness of special protection area system, further specific standards for special protection area designation and management would be needed, considering ecological and social importance of target areas.

The State of Marine Pollution in the Waters adjacent to Shipyards in Korea - 2. Assessment of the Pollution of Heavy Metals in Seawater around Major Shipyards in Summer 2010 (국내 조선소 주변해역의 해양오염 현황 - 2. 2010년 하계 대형조선소 주변 해수의 중금속오염 평가)

  • Kim, Kwang-Soo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.1
    • /
    • pp.9-17
    • /
    • 2015
  • In order to elucidate the current state of marine pollution of heavy metals around major shipyards in Korea, seawater samples were collected at eleven sampling stations and four control stations around 4 major shipyards located in the southeastern coast of Korea in summer 2010, and 6 kinds of metals such as copper(Cu), zinc(Zn), iron(Fe), cadmium(Cd), lead(Pb) and mercury(Hg) in seawater samples were analyzed. The analyses of heavy metals in seawater showed that the mean Cu concentrations in seawater around 4 major shipyards were in the range of $0.817{\sim}1.638{\mu}g/L$ which were lower than Korean environmental standards of $20{\mu}g/L$ for the protection of human health(PHH) and of $3{\mu}g/L$ for short-term protection of marine ecosystem(SPME) but higher than Cu concentration at control station by a factor of up to 2.75. The mean Zn concentrations were in the range of $0.228{\sim}0.567{\mu}g/L$ which were lower than Korean environmental standards of $100{\mu}g/L$ for PHH and $34{\mu}g/L$ for SPME but higher than Zn concentration at control station by a factor of up to 5.91. The mean Fe concentrations were in the range of $3.332{\sim}7.410{\mu}g/L$ which were higher than Fe concentration at control station by a factor of up to 6.75. The mean Cd concentrations were in the range of $0.013{\sim}0.028{\mu}g/L$ which were lower than Korean environmental standards of $10{\mu}g/L$ for PHH and $19{\mu}g/L$ for SPME but higher than Cd concentration at control station by a factor of up to 2.33. The mean Pb concentrations were in the range of $0.007{\sim}0.126{\mu}g/L$ which were lower than Korean environmental standards of $50{\mu}g/L$ for PHH and $7.6{\mu}g/L$ for SPME. The mean Hg concentrations were in the range of $0.002{\sim}0.004{\mu}g/L$ which were lower than Korean environmental standards of $0.5{\mu}g/L$ for PHH and $1.8{\mu}g/L$ for SPME. Although the concentrations of metals such as Cu, Zn and Fe which were used in shipbuilding works were lower than Korean environmental standards for PHH and SPME, the fact that the concentrations of Cu, Zn and Fe at sampling stations around major shipyards were higher than those at control stations implies that the works in shipyards had some effects on marine water quality around shipyards. Therefore, marine environment management such as the prevention and control of the discharge of various pollutants from shipyards is required on national level.

Fire Combustion Characteristics of Membrane Materials According to the Height and Heat Generation Rate (막재료의 설치높이와 발열량에 따른 화재연소특성)

  • Cho, Seung-Ho;Choi, Kwang-Ho;Roh, Young-Sook
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.6
    • /
    • pp.84-90
    • /
    • 2016
  • Various form of membrane structures are being built in recent years. However, there is no appropriate fire proofing standards which can be applied each specific membrane structures. Therefore, existing fire protection standards are in establishment state and they need to be revised. In the current study, commonly used membrane materials(ETFE, PVF, PTFE) has been selected to investigate its fire resistance behavior with the change of fire duration time. In addition to this, heat generation rate of the membrane materials in correlation with the height of membrane has been investigated. And these fire combustion characteristics of membrane materials can be used in future practice for the fire prevention regulations of membrane structures.

A Study on Proposal of Facility Standard by Research of Safety Accidents at Elderly Housing Welfare Facility (노인주거 복지시설 안전사고 실태조사에 의한 시설기준 제안에 관한 연구)

  • You, Jong-Ok;Park, Jae-Seung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.17 no.2
    • /
    • pp.7-16
    • /
    • 2011
  • The death toll of the elderly by accidents in 2007 takes 6.5% of total death toll. The lost income from this is estimated to be 17 trillion and 511 billion won. According to CISS of Korea Consumer Protection Board, the number of safety related accidents of the elderly at home in 2006 was 486 cases in 2006 and has gradually increased every year. This thesis created 115 guidelines at 14 spaces as facility evaluation index evaluating the aging friendliness of the facility and safety related accidents generated at elderly resident welfare facility, examined influence variables of safety related accidents with 191 elderly including demographic variable, physical skill variable, social psychological variable and facility environmental variables, and then verified relevance between safety accidents and each influence variable. As a result, it was verified through ANOVA test of SAS Package Program and $x^2$- test that facility environmental variable would be closely related to the accident. In this regard, this study newly proposes the facility standards of aging friendly facility by supplementing them with contents and guidelines of facility evaluation table as ways to reduce safety related facility of the elderly.

A Study on the Regulatory Technology for Lightning Protection and Grounding System in Nuclear Power Plants (원전낙뢰보호 및 접지계통에 대한 규제기술연구)

  • Lee, J.D.;Zhu, O.P.;Lee, S.K.;Kim, D.S.
    • Proceedings of the KIEE Conference
    • /
    • 2007.11b
    • /
    • pp.66-68
    • /
    • 2007
  • The regulatory guide, RG-1.204 and its underlying or confirmatory research, NUREG/CR-6866 were studied for Korean application to LPGS of NPPs. However they excluded the application to that of NPPs. So US-NRC approved selectively industrial standards to that of NPPs on Nov 2005. It is necessary to understand the basis of regulatory technology related regulatory positions on LPGS and important to implement the guidance on LPGS as a resonable standard. The paper is examined what and how state of the art of relevant technology applied to the LPGS as well as the trip-out events related to electrical system were involved with LPGS. We reviewed the relevant standards applicable to Korean NPPs. Following are concluded to recommend. (1) IEEE 510-1050 is recommended as a guide for I&C grounding against EMI and lighting transients (2) IEEE Std-665, 510-666, Std-C62.23 for electrical grounding against voltage surges and lighting transients (3) Inspection should be thoroughly be implemented a frequency of 3-5 year period according to NFPA780 or KSC-IEC 61024.

  • PDF

A study on odor and ventilation in waste treatment facilities (폐기물 처리시설에서의 악취 및 환기에 관한 연구)

  • Seo, Byung-Suk;Jeon, Yong-Han
    • Design & Manufacturing
    • /
    • v.14 no.2
    • /
    • pp.28-33
    • /
    • 2020
  • Recently, as the income level and quality of life have improved, the desire for a pleasant environment has increased, and a deodorization plan is required through thorough prevention and diffusion of odorous substances in waste treatment facilities recognized as hateful facilities, appropriate collection, and selection of the right prevention facilities. In this study, a waste disposal facility was modeled and computerized analysis for odor and ventilation analysis was conducted. Numerical analysis of the waste treatment facility was performed at the size of the actual plant. CATIA V5 R16 for numerical model generation and ANSYS FLUENT V.13 for general purpose flow analysis were used as analysis tools. The average air-age of the internal was 329 seconds, and the air-flow velocity was 0.384m/s. The odor diffusion analysis inside the underground pump room showed congestion-free air circulation through streamline distribution and air-age distribution. This satisfies the ASHRAE criteria. In addition, the results of diffusion analysis of odorous substances such as ammonia, hydrogen sulfide, methyl mercaptan and dimethyl sulfide were all expected to satisfy the regulatory standards. Particularly in the case of the waste loading area, the air-flow velocity was 0.297m/s, and the result of meeting the regulatory standards with 0.167ppm of ammonia, 0.00548ppm of hydrogen sulfide, 0.003ppm of methyl mercaptan, and 0.003ppm of dimethyl sulfide was found.

Earth Building Characteristic Analysis to Utilize in Architecture Plan (건축 계획적 활용을 위한 흙건축 특성분석)

  • Lee, jang-hyuk;Hwang, hey-zoo;Kim, Jeong-Gyu
    • KIEAE Journal
    • /
    • v.7 no.4
    • /
    • pp.3-8
    • /
    • 2007
  • This study is aimed to apply basic data to planning earth building through analyzing characteristics of earth building. For doing it, we investigated a research paper in advanced countries(New zealand, Australia, etc.) that has been used for earth building standards for a long time, and then we corrected inadequate standards that would apply our earth building environment. As a result, we can devide earth characteristics into three parts that are materials, plan, and maintenance and repair. First, as material selection is very important factor, a general plan is possible to change in accordance with what material is selected. These methods that made mud brick, pressed earth block, rammed earth, cob have been well used during the current 30 years in earth building. Second, the plan is composed of site select and architecture plan. In architecture plan, we should consider from foundation to eaves protection, and in site selection, consider sides of the environment and the social. Third, we should always check a periodical inspection through watchful observation because earth buildings need more time and efforts in maintaining and repairing than others.

Comparison of SE Evaluation Methods for HEMP Shelters (HEMP 방호시설의 SE 평가방법의 비교)

  • Chung, Yeon-Choon;Lee, Jongkyung;Kwun, Suk-Tai
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.11
    • /
    • pp.1197-1200
    • /
    • 2014
  • Two test standards to be applied for evaluating shielding effectiveness of HEMP protection facilities, MIL-STD-188-125-1 and IEEE std. 299, provide different test results in spite of the same facility. In particular, at the frequency range of 10 kHz~20 MHz, it is confirmed that the test results by the IEEE Std. 299 are about 20~30 dB lower than the evaluated results by MIL-STD-188-125-1. These results are due to the different measurement conditions specified in the two test standards. Therefore, IEEE Std. 299 can be applied for the shortening of test distance, but the required SE performance based on MIL-STD-188-125-1 must be modified.

The Performance Improvement of Lightning Arrester Leakage Current Measuring Device for GIS (GIS용 피뢰기 누설전류 측정장치 성능개선)

  • Kim, Won-Gyu;Kim, Min-Soo;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.12
    • /
    • pp.1726-1731
    • /
    • 2014
  • This paper shows the developed new lightning arrester LCM (Leakage Current Measuring device) which is important element of GIS (Gas Insulated Switchgear) Preventive & Diagnostic system and verify its performance though strengthened test standards. The existing lightning arrester LCM was modified to solve measuring errors which happened frequently. At first, we explained the principle of measuring leakage current. Through analyzing some problems which the existing LCM have. we got some improvable items. For the performance verification of the improved LCM, we manufactured prototype LCM which is applied some improvable items such as improving LCM circuit, adding protection circuit, optimizing inner structure of LCM and changing ground design. After then we carried out the performance test. Accredited testing laboratory carried out the performance verification test according to performance test criteria and procedure of reliability test standards, IEC-60225, 61000 and 60068 etc. We confirmed the test results which correspond with the performance test criteria. Also, we confirmed the performance of the improved LCM installed & being operated at G Substation through the immunity test against the normal noise and open/close surge etc.