• 제목/요약/키워드: Protection Reinforcement

검색결과 164건 처리시간 0.023초

Enhancing Location Privacy through P2P Network and Caching in Anonymizer

  • Liu, Peiqian;Xie, Shangchen;Shen, Zihao;Wang, Hui
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제16권5호
    • /
    • pp.1653-1670
    • /
    • 2022
  • The fear that location privacy may be compromised greatly hinders the development of location-based service. Accordingly, some schemes based on the distributed architecture in peer-to-peer network for location privacy protection are proposed. Most of them assume that mobile terminals are mutually trusted, but this does not conform to realistic scenes, and they cannot make requirements for the level of location privacy protection. Therefore, this paper proposes a scheme for location attribute-based security authentication and private sharing data group, so that they trust each other in peer-to-peer network and the trusted but curious mobile terminal cannot access the initiator's query request. A new identifier is designed to allow mobile terminals to customize the protection strength. In addition, the caching mechanism is introduced considering the cache capacity, and a cache replacement policy based on deep reinforcement learning is proposed to reduce communications with location-based service server for achieving location privacy protection. Experiments show the effectiveness and efficiency of the proposed scheme.

보호동기이론에 기반한 조직구성원의 보안강화 : 보안정책에 대한 신뢰와 보안스트레스의 매개효과를 중심으로 (Security Enhancement of Public Organization Members Based on the Protection Motivation Theory)

  • 최희영;강주영
    • 한국IT서비스학회지
    • /
    • 제19권6호
    • /
    • pp.83-95
    • /
    • 2020
  • "I think security is only trying to make it uncomfortable." "10% of my work is entering IDs and passwords, such as boot passwords, mobile phone authentication numbers, etc." As reflected in the complaint above, stress caused by information security among organizations' members is increasing. In order to strengthen information security, practical solutions to reduce stress are needed because the motivation of the members is needed in order for organizations to function properly. Therefore, this study attempts to suggest key factors that can enhance security while reducing information security stress among members of organizations. To this end, based on the theory of protection motivation, trust and security stress from information security policies are set as mediating factors to explain changes in security reinforcement behavior. Furthermore, risk, efficacy, and reaction costs of cyberattacks are considered as prerequisites. Our study suggests a solution to the security reinforcement problem by analyzing the factors that influence the behavior of members of organizations. In turn, this can raise protection motivation among members.

해안사구 모래보강을 통한 해안침식 저감 효과 - 충청남도 다사리 사구를 사례로 - (The Mitigating Effects of Seaward Dune Reinforcement Against Coastal Erosion in Dasa-ri, Chungcheongnam-do, South Korea)

  • 공학양;박성민;신영규;최광희
    • 한국지형학회지
    • /
    • 제25권4호
    • /
    • pp.37-47
    • /
    • 2018
  • Coastal sand dunes have been regarded as natural defenses to protect hinterland from disasters such as storm surge and typhoons. However, many dunes are not well-deserved in South Korea because of imprudent land development or inappropriate measures after coastal erosion. Lately, beach nourishment and dune reinforcement are emphasized as the effective and environmentally sustainable solution for the coastal protection. They are regarded good strategies to keep landscapes for a time, with little side effects. However, there is little knowledge on the construction methods including proper design and time plans for the best results.In addition, the effects of dune reinforcement in the field should be tested.In thisstudy, we performed sand filling in an eroded dune scarp and surveyed topographic changes in the beach-dune system, which is located along Dasa-ri coast, Chungnam Province, South Korea. Using a network RTK-GPS and drone-based aerial photographs, we analyzed the temporal and spatial changes in the area, before and after the reinforcement. As a result, the dune reinforcement seems to be helpful to mitigates the coastal erosion and to prevent the coastline retreat at least for one year.

콘크리트내 표면매립보강된 FRP의 내화단열방법과 연단거리에 따른 온도변화 (Temperature Variation Corresponding to the Protection Method and Edge Distance in Near-Surface-Mounted FRP in Concrete with Fire Protection)

  • 임종욱;서수연
    • 대한건축학회논문집:구조계
    • /
    • 제35권11호
    • /
    • pp.137-146
    • /
    • 2019
  • Recently, the Near-Surface-Mounting method using Fiber reinforced polymer (FRP) has been developed and applied to the reinforcement of many concrete structural members. However, as a part of the fire resistance design, there is a lack of research related to fire insulation for the areas reinforced with FRP. In case of NSM reinforcement, there is a difference in the transferred temperature from the external surface to the groove corresponding to the location of the groove where the FRP is embedded, and the effect of this should be reflected in the fireproof insulation design. Therefore, in this study, after forming grooves for surface embedding in concrete blocks, fireproof insulation reinforcement was performed using Calcium Silicate (CS) fireproof board and an experiment to evaluate the temperature transfer was performed. By observing the temperature at these groove positions, the reduction of temperature transfer according to fireproof insulation detail was studied. As a result, when the NSM-FRP is properly fire-insulated using the CS-based fireproof board, the epoxy inside the groove does not reach its glass transition temperature until the external temperature reaches $800^{\circ}C$.

On the optimum design of reinforcement systems for old masonry railway tunnels

  • Ghyasvand, Soheil;Fahimifar, Ahamd;Nejad, Fereidoon Moghadas
    • Geomechanics and Engineering
    • /
    • 제28권2호
    • /
    • pp.145-155
    • /
    • 2022
  • Safety is a most important parameters in underground railway transportation; Also stability of underground tunnel is very important in tunneling engineering. Design of a reliable support system requires an evaluation of both ground demand and support capacity. Iran's traditional railway tunnels are mainly supported with masonry structures or unsupported in high quality rock masses. A decrease in rock mass quality due to changes in groundwater regime creep and fatigue in rock and similar phenomena causes tunnel safety to decrease during time. The case study is an old tunnel in Iran, called "Keshvar"; it is more than 50 years old railway organization. In operating this Tunnel, until the several problems came up based on stability and leaking water. The goal of study is evaluation of the various reinforcement systems for supporting of the tunnel. The optimal selection of the reinforcement system is examined using TOPSIS Fuzzy method in light of the looming and available uncertainties. Several factors such as; the tunnel span, maintenance, drainage, sealing, ventilation, cost and safety were based to choose the method and system of designing. Therefore, by identifying these parameters, an optimal reinforcement system was selected and introduced. Based on optimization system for analysis, it is revealed that the systematic rock bolts and shotcrete protection had a most appropriate result for these kind of tunnel in Iran.

절토사면의 Nailing 보강 Fabric Form의 설계와 시공 (Design and Construction of Green Slope Fabric Form on Cutting Slope)

  • 송재헌;최영근
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 토목섬유 특별세미나
    • /
    • pp.81-92
    • /
    • 2000
  • Green Slope(F.F.R : Fabric Form Reinforcement Method) is one of an environmental slope protection method at steep cutting sites. This method is that soil and rock at the steep slope is fixed using the environmental Fabric Form, Nail, Rock Bolt and Rock Anchor, And then, the surfaces covered with grasses or weeds. This method will be satisfied both safe slope protection and natural environment appearance. Green Slope is a useful method of the construction sites of steep cutting slopes.

  • PDF

낙동강유역 홍수방지대책 제언 (Flood Control Measures of the nakdong River Basins)

  • 구본충
    • 기술사
    • /
    • 제35권4호
    • /
    • pp.48-51
    • /
    • 2002
  • Due to locally torrential downpours which shows Increasing trend, high tide of the southern sea of Korea and etc. submerged and Inundated districts at the lowlands of Nakdong River Basins has been Increasing year by year In order to protect flood hit, it is necessary to make an early implementation of flood control dam and other flood protection works according to Nakdong River Comprehensive Development Project. In addition to the large scale comprehensive projects, local key measures, such as lowland development control, embankment reinforcement, leakage protection, maintenance and management of facilities, increase in pumping station, will be highly effective.

  • PDF

철근의 영향과 앵커 충돌각도를 고려한 유연콘크리트 매트리스의 손상평가 (Damage Evaluation of Flexible Concrete Mattress Considering Steel Reinforcement Modeling and Collision Angle of Anchor)

  • 류연선;조현만;김서현
    • 한국해양공학회지
    • /
    • 제30권2호
    • /
    • pp.109-116
    • /
    • 2016
  • A flexible concrete mattress (FCM) is a structural system for protecting submarine power or communication cables under various load types. To evaluate its of protection performance, a numerical analysis of an FCM under an anchor collision was performed. The explicit dynamics of the finite element analysis program ANSYS were used for the collision analysis. The influences of the steel reinforcement modeling and collision angle of the anchor on the collision behavior of the FCM were estimated. The FCM damage was evaluated based on the results of the numerical analysis considering the numerical modeling and collision environment.

인하도선으로 활용하기 위한 철근콘크리트구조물의 전기 및 기계적 소요 특성에 대한 실험적 검증 (Experimental Verification on the Use of Steelwork as a Down-Conductor in Lightning Protection System)

  • 이기홍
    • 조명전기설비학회논문지
    • /
    • 제25권9호
    • /
    • pp.94-99
    • /
    • 2011
  • This paper verified the characteristics of electrical continuity and mechanical strength of steelwork required to use it as a down-conductor in lightning protection system. It was proven that the steelwork in reinforced concrete apartment has an excellent electrical continuity with low resistance(less than 0.2[${\Omega}$].). But it was confirmed that a poor connection between two reinforcement bars can easily cause serious damages of the concrete even with the impulsive current of 50[kA], 10/350[${\mu}s$]. These results of experiments mean that the additional measures are necessary in using the steelwork as the down-conductor of the lightning protection system.

Lifetime of Insoluble Anode for Cathodic Protection on Concrete Construction

  • Sohn, Kicheon;Chang, Hyunyoung;Kim, Youngsik
    • Corrosion Science and Technology
    • /
    • 제4권2호
    • /
    • pp.56-59
    • /
    • 2005
  • In rebar concrete structure, the corrosion of rebar can arise the deterioration of concrete structure and may affect the safety of the whole system. Recently, several methods for corrosion protection have been used and are more important for concrete structure using the sand including chloride ion. Among several protections, electrical cathodic protection has been expected to be one of the most useful methods in corrosion protection for reinforcement of concrete structures. The anode for cathodic protection needs high current density, high corrosion resistance and low overvoltage. To fill up the special qualities, the insoluble anodes were developed and these anodes were coated with metal oxide of $TiO_2$, $ZrO_2$, $RuO_2$, and $IrO_2$. Lifetime of these anodes can be one of the important factors affecting the lifetime of concrete structure in cathodic protection. In this work, several anodes were made by sol-gel method and thermal decomposition method and the lifetime of these anodes was evaluated by NACE international standard test method, TM 0294-94. Also, we did analyze the properties of coated metal oxides.