The present writer conducted this study in order to seek desirable directions to enhance right recognition of aesthetic dental prostheses and maximize the aesthetic effect of dental prostheses, by investigating satisfaction with and recognition of aesthetic prostheses among citizens in Daejeon, the writer carried out a self-administered survey with a questionnaire, reaching the following conclusions. 1. It was revealed that 54.4% of them had previous knowledge of aesthetic prostheses while 45.6% had not, and among people with the knowledge, 20.8% acquired it from the dental clinic interested. 2. It was revealed that 58.9% were not satisfied with their front teeth, and among them 24.8% were discontented with their teeth color most. 3. In general characteristics according to whether or not they have previous knowledge aesthetic prosthesis, among people with the knowledge 58.8% were female while 41.2% were male, showing a statistically significant difference (pM0.002). 4. In terms of levels of satisfaction with aesthetic dental prostheses by age, in the case of dissatisfaction people over 30 were most with 14.1%. 5. In terms of levels of recognition of aesthetic prostheses according to whether or not they have previous knowledge of those, among people with the knowledge, 55.8% reported that aesthetic prostheses are necessary (pM0.000). 6. In terms of levels of recognition of aesthetic prostheses according to whether or not they have aesthetic prostheses, among people with knowledge of the kinds of aesthetic prostheses, 87.2%(pM0.000). It was thought that in order to create accurate recognition of and enhance satisfaction with aesthetic dental prostheses, dental care expenses should be adjusted reasonably and also dentists should perform public relations actively with accurate information and provide related education.
Purpose: The purpose of this study was to compare the maximum occlusal force implant prostheses to natural teeth. Material and Method: Fifty nine patients treated either with $Br{\aa}anemark$ implants and ITI implants during the recent ten years were involved in this study. The maximum occlusal force were measured with unilateral bite force recorder and dental prescale system. Results: 1. The maximum occlusal forces of the implant prostheses and natural teeth were not significantly different where measured with unilateral bite force recorder and dental prescale system. 2. The maximum occlusal forces were not significantly different between $Br{\aa}nemark$ implant and ITI implant prostheses. 3. The maximum occlusal forces of the implant prostheses had lower when compared with natural teeth during 1-6 months functional periods when measured with the unilareral bite force recorder(P<0.05) and 1-12 months functional periods when measured with the dental prescale system(P<0.05). After these periods there was not statistical significant difference between the implant prostheses and natural teeth. 4. The maximum occlusal forces of the wide diameter implant prostheses were higher than the maximum occlusal forces of the regular diameter implant prostheses when measured with dental prescale system(P<0.05), but there was no significant difference between the wide diameter and the regular diameter implant prostheses when measured with unilateral bite force recorder. 5. The maximum occlusal forces of the single implant prostheses were not significantly different with the splinting implants prostheses. 6. The maximum occlusal forces of the implant prostheses were not significantly different by age and sex. 7. There was significantly different between maximum occlusal forces measured with unilateral bite force recorder and dental prescale system(P<0.0001) but there was positive correlation(r=0.52. P<0.05). Conclusion: The maximum occlusal forces of the implant prostheses were not significantly different to natural teeth during clenching and unilateral maximum biting.
Purpose: The purpose of this study was to evaluate the internal fitness of prostheses fabricated with non-contact extra-oral scanner and those fabricated with intra-oral video scanner, with a comparative accuracy analyses of their precision and trueness. Methods: A polymethyl methacrylate (PMMA) model was fabricated by replicating a master model. The prostheses in the first group were fabricated based on the PMMA model with an intra-oral video scanner (IVS group). Following the fabrication of work models with Type IV Stone that were based on the PMMA model, the prostheses in the second group were fabricated with a non-contact extra-oral scanner (ENB group). The precision and trueness of the prostheses were calculated from comparisons of the three-dimensional images of the internal surfaces of the prostheses and those of the master model. Kruskal-Wallis tests were used to determine the statistical significance, with the level of type 1 error set at 0.05. Results: Trueness (P < 0.009) and precision (P < 0.001) did not differ significantly between the ENB and IVS groups. The IVS group exhibited lower trueness values and larger precision values than the ENB group. Conclusion: Although no significant differences were found in the internal fitness of the prostheses that were fabricated by the two different scanners, the intraoral video scanner-fabricated prostheses had better trueness, whereas the non-contact extra-oral scanner-fabricated prostheses had better precision.
Purpose: This study aimed to obtain basic data on oral health improvement by investigating the EQ-5D index according to the oral prosthesis status of elderly persons aged 65 years or older in Korea using the Seventh Korea National Health and Nutrition Examination Survey. Methods: In this study, 3,426 elderly persons aged 65 years or older were included to analyze the relationship between the dental prostheses status and EQ-5D index in the collected data. Results: Compared to the "complete denture" in oral prosthesis, EQ in case of no dental prostheses or fixed dental prostheses is comparable to removable prosthetics such as "no dental prostheses," "one fixed bridge," and "two or more fixed bridges." Removable partial denture and complete denture required for the maxillary and mandibular EQ-5D index were significantly higher in "not necessary" than in "complete denture necessary" in all the elderly persons. Conclusion: The condition of the dental prosthesis and the need for a removable partial denture and complete denture for the elderly's EQ-5D index were confirmed, and it was found that the fixed dental prostheses were more effective than the removable dental prostheses. Therefore, oral health education programs for the elderly should be developed to promote dental function and oral health maintenance.
Total elbow prostheses which are now available in clinical use can generally be classified into two major categories ; one bing linked prostheses, another being unlinked prostheses. Of those two categories I am dealing here only with the problems of the unlinked type prosthesis, particularly with those of non-constrained, surface-replacement prostheses. Furthermore, my presentations this time may have to be narrowed down only to the topics regrading the particular features and some of the technical problems with Kudo Elbow Prosthesis, due to the time limit assigned for this presentation.
고정성 보철물의 장기적 예후를 보장하고자 하는 많은 노력에도 불구하고, 아직도 임상에서는 부적절한 제작 및 유지 관리로 인한 다양한 고정성 보철물의 합병증이 관찰되고 있다. 이에 본 연구에서는 고정성 보철물의 임상적 상태를 조사하여 보철 진료의 임상적 참고 자료와 연구의 기초 자료로 도움이 되고자하였다. 2009년 1월에서 2009년 12월까지 12개월간 부산대학교병원 치과 보철과에 내원한 환자 중 기존의 고정성 보철물을 철거하고 치료를 시행한 환자를 대상으로 고정성 보철물과 지대치에 연관된 임상적 상태를 조사 평가하여 다음과 같은 결과를 얻었다. 1. 전체 고정성 보철물의 추정 수명은 10.0년이었고, 평균 장착 기간은 $10.3{\pm}5.5$년이었다. 2. 악골에 따른 수명의 차이는 없었으나 (P>.05), 전후방 위치에서는 전치부 또는 구치부에 비해 전치부와 구치부를 포함하는 보철물의 수명이 가장 길었다 (P<.05). 3. 고정성 보철물의 재료별 수명은 금속관이 가장 길었고 (P<.05), 다른 재료들 간에는 유의한 차이가 없었다 (P>.05). 4. 고정성 보철물의 크기는 보철물 수명에 영향을 미치지 않았다 (P>.05). 5. 대합치 조건별 고정성 보철물의 수명은 자연치와 고정성 보철물, 가철성 국소 의치, 총의치 순으로 길었다 (P<.05). 6. 고정성 보철물의 생물학적 합병증은 치주 질환 (37.5%), 치아 우식증 (19.0%), 그리고 치수 질환 (10.8%) 순이었고, 기계적 문제점은 변연 결함 (18.4%), 보철물 파절(4.2%), 유지력 상실 (3.9%), 치아 파절 (3.6%), 그리고 식편 압입 (2.6%) 순이었다. 보철물을 철거한 후 치대치의 33.1%는 재수복이 불가능한 상태였다.
In this study, oral sensory function in the osseointegrated root form implant-supported prostheses wearers was estimated by measuring occlusal tactile perception threshold of thickness and sensibility threshold against lateral static loading, and comparing with normal dentition subjects and complete denture wearers group. Osseointegrated root form implants seemed to be restored in the sensation to some extent, and so, dental implants restored edentulous patients in a wide meaning. Conclusions were summarized as following. 1. Occlusal tactile perception threshold of thickness was highest in complete denture wearers group, following by implant-supported prostheses wearers group, normal dentition subjects group. 2. In the implant-supported prostheses wearers group, occlusal tactile perception threshold of opposing artificial teeth case was higher than of opposing natural or opposing implantsupported teeth case. 3. Sensibility threshold against lateral loading of complete denture wearers and implantsupported prostheses wearers group was higher than that of normal dentition subject group. 4. In the implant-supported prostheses group, sensibility threshold against lateral loading was not significantly different between upper and lower jaws. 5. In occlusal tactile perception threshold of thickness and sensibility threshold against lateral loading test, there was no regularity among values of each tooth, and no significant difference between anterior and posterior teeth as well.
임플란트-지지 고정성 보철물의 누적 생존율을 구하고, 생존율에 영향을 미치는 요소와 요소 간 상관관계를 평가하여, 임플란트-지지 고정성 보철물의 예후를 예측하는 데 도움을 주고자 한다. 2000년에서 2007년까지 부산대학교 치과병원에 내원한 환자 중 임플란트를 식립하고 임플란트-지지 고정성 보철물을 제작한 환자를 대상으로 임플란트-지지 고정성 보철물과 관련한 종합적인 임상적 상태를 조사 평가하여 다음과 같은 결과를 얻었다. 1. 전체 임플란트-지지 고정성 보철물의 추정 수명은 11.7년이었고, 고정성 보철물에 문제가 발생되는 추정 시점은 9.5년이었다. 2. 나이와 성별에 따른 수명의 차이는 나타나지 않았다(P>.05). 3. 치아 발거 원인은 임플란트-지지 고정성 보철물의 수명에 영향을 미쳤다(P<.05). 치아 우식증의 경우 고정성 보철물의 수명은 10.0년, 치주 질환의 경우 9.0년이었다. 4. 악골에 따른 수명의 차이는 나타나지 않았으나(P>.05), 전후방 위치에서는 소구치부 보철물의 수명이 11.0년으로 수명이 길었고, 대구치 부위 보철물의 수명이 8.8년으로 짧았다(P<.05). 5. 임플란트-지지 고정성 보철물의 크기는 보철물의 수명에 영향을 미치지 않았다(P>.05). 6. 대합치 조건별 임플란트-지지 고정성 보철물의 수명은 차이가 없었다(P>.05). 7. 임플란트-지지 고정성 보철물의 합병증은 식편 압입(40.5%), 도재 파절(25.8%), 나사 풀림(23.6%) 순이었다. 식편 압입은 임플란트 위치와 상관관계를 보였고, 나사와 관련된 문제는 임플란트 위치와 보철물 종류에 영향을 받았다(P>.05).
현재 악안면 보철 제작에 있어 재료로 실리콘이 제일 많이 사용되고 있으나 이 재료는 시간이 지남에 따라 점차 굳어져 가고 탄력성을 잃으며 원래의 색도 노랗게 변색되어 간다는 단점이 있다. 이러한 재료의 화학적 구성 단점 때문에 보철 생명력을 유지하기 위하여 환자들은 매 3년마다 새로운 보철물을 재 제작하여야 한다. 그렇다면 복잡했던 악안면 기공 과정을 다시 반복해야 하는 시간적, 물질적 손실을 감수해야 했다. 이러한 단점들을 보완하고 환자 피부색과 적합이 잘 되는 다양한 색의 실리콘 개발과 아울러 눈동자를 깜빡일 수 있는 인공 눈동자의 개발 등이 필요하며, 눈동자를 만드는데 사용되는 인공 수정체의 발전이 향후 악안면 보철 분야의 큰 과제라 할 수 있다.
This paper reports marginal bone loss around osseointegrated implants after loading in partially edentulous patients in dental hospital, Yonsei University. Two types of implants($Br{\aa}nemark^{TM},\;IMZ^{TM}$) were used. Through the digital measurement on periapical radiograph around 37 implants in human subjects, marginal bone loss was observed for 24 months after delivery of prostheses. The results were as follows; 1. According to experimental periods marginal bone loss in total implants was 1.775 mm at 12 months, 1.921 mm at 24 months after delivery of prostheses(p<0.05). 2. Marginal bone loss in the $Br{\aa}nemark$ implants was 1.831 mm at 12 months, 1.833 mm at 24 months after delivery of prostheses(p<0.05). 3. Marginal bone loss in the IMZ implants was 1.578 mm at 12 months, 2.907 mm at 23 months after delivery of prostheses(p<0.05). 4. During the first year after loading, the IMZ implants showed less marginal bone loss than the $Br{\aa}nemark$ implants but, during the next the $Br{\aa}nemark$ implants showed less than the IMZ implants(p>0.05). These results indicate that marginal bone loss around osseointegrated implants occurs within the first 12 months after delivery of prostheses and stabilizes thereafter, so it is necessary to be careful of using dental implants for the first year after delivery of prostheses.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.