• 제목/요약/키워드: Proportional damping system

검색결과 93건 처리시간 0.024초

비 비례적 감쇠를 갖는 선형 이산 구조동력학 모델에 대한 FFT-활용 스펙트럴해석법 (FFT-based Spectral Analysis Method for Linear Discrete Structural Dynamics Models with Non-Proportional Damping)

  • 이우식;조주용
    • 한국철도학회논문집
    • /
    • 제9권1호
    • /
    • pp.63-68
    • /
    • 2006
  • This paper proposes a fast Fourier transform(FFT)-based spectral analysis method(SAM) for the dynamic responses of the linear discrete dynamic models with non-proportional damping. The SAM was developed by using discrete Fourier transform(DFT)-theory. To verify the proposed SAM, a three-DOF system with non-proportional viscous damping is considered as an illustrative example. The present SAM is evaluated by comparing the dynamic responses obtained by SAM with those obtained by Runge-Kutta method.

A Virtual RLC Active Damping Method for LCL-Type Grid-Connected Inverters

  • Geng, Yiwen;Qi, Yawen;Zheng, Pengfei;Guo, Fei;Gao, Xiang
    • Journal of Power Electronics
    • /
    • 제18권5호
    • /
    • pp.1555-1566
    • /
    • 2018
  • Proportional capacitor-current-feedback active damping (AD) is a common damping method for the resonance of LCL-type grid-connected inverters. Proportional capacitor-current-feedback AD behaves as a virtual resistor in parallel with the capacitor. However, the existence of delay in the actual control system causes impedance in the virtual resistor. Impedance is manifested as negative resistance when the resonance frequency exceeds one-sixth of the sampling frequency ($f_s/6$). As a result, the damping effect disappears. To extend the system damping region, this study proposes a virtual resistor-inductor-capacitor (RLC) AD method. The method is implemented by feeding the filter capacitor current passing through a band-pass filter, which functions as a virtual RLC in parallel with the filter capacitor to achieve positive resistance in a wide resonance frequency range. A combination of Nyquist theory and system close-loop pole-zero diagrams is used for damping parameter design to obtain optimal damping parameters. An experiment is performed with a 10 kW grid-connected inverter. The effectiveness of the proposed AD method and the system's robustness against grid impedance variation are demonstrated.

Dynamic properties of a building with viscous dampers in non-proportional arrangement

  • Suarez, Luis E.;Gaviria, Carlos A.
    • Structural Engineering and Mechanics
    • /
    • 제55권6호
    • /
    • pp.1241-1260
    • /
    • 2015
  • Any rational approach to define the configuration and size of viscous fluid dampers in a structure should be based on the dynamic properties of the system with the dampers. In this paper we propose an alternative representation of the complex eigenvalues of multi degree of freedom systems with dampers to calculate new equivalent natural frequencies. Analytical expressions for the dynamic properties of a two-story building model with a linear viscous damper in the first floor (i.e. with a non-proportional damping matrix) are derived. The formulas permit to obtain the equivalent damping ratios and equivalent natural frequencies for all the modes as a function of the mass, stiffness and damping coefficient for underdamped and overdamped systems. It is shown that the commonly used formula to define the equivalent natural frequency is not applicable for this type of system and for others where the damping matrix is not proportional to the mass matrix, stiffness matrix or both. Moreover, the new expressions for the equivalent natural frequencies expose a novel phenomenon; the use of viscous fluid dampers can modify the vibration frequencies of the structure. The significance of the new equivalent natural frequencies is expounded by means of a simulated free vibration test. The proposed approach may offer a new perspective to study the effect of viscous dampers on the dynamic properties of a structure.

Inserting the mass proportional damping (MPD) system in a concrete shear-type structure

  • Silvestri, Stefano;Trombetti, Tomaso;Ceccoli, Claudio
    • Structural Engineering and Mechanics
    • /
    • 제16권2호
    • /
    • pp.177-193
    • /
    • 2003
  • This paper presents an illustrative example of the advantages offered by inserting added viscous dampers into shear-type structures in accordance with a special scheme based upon the mass proportional damping (MPD) component of the Rayleigh viscous damping matrix. In previous works developed by the authors, it has been widely shown that, within the class of Rayleigh damped systems and under the "equal total cost" constraint, the MPD system provides best overall performance both in terms of minimising top-storey mean square response to a white noise stochastic input and maximising the weighted average of modal damping ratios. A numerical verification of the advantages offered by the application of MPD systems to a realistic structure is presented herein with reference to a 4-storey reinforced-concrete frame. The dynamic response of the frame subjected to both stochastic inputs and several recorded earthquake ground motions is here analysed in detail. The results confirm the good dissipative properties of MPD systems and indicate that this is achieved at the expense of relatively small damping forces.

감도계수 반복법을 이용한 비비례감쇠계의 고유치 및 고유벡터 변화량 해석 (Analysis of Eigenderivative for the Non-Proportional Damped Structure Using the Iterative Method of the Sensitivity Coefficient)

  • 이정윤
    • 대한기계학회논문집A
    • /
    • 제30권7호
    • /
    • pp.750-756
    • /
    • 2006
  • This study predicts the modified eigenvectors and eigenvalues of the non-proportional damped structure due to the change in the mass, damping and stiffness of structure by iterative method of the sensitivity coefficient using the original dynamic characteristic. The method is applied to the non-proportional damped 3 degree of freedom system by modifying the mass, damping and stiffness. The predicted dynamic characteristics are showed a good agreement with these from the structural reanalysis using the modified mass, damping and stiffness.

동특성 변화를 이용하여 비례감쇠 구조물의 변경된 설계파라미터 예측 (Prediction of Changed Design Parameter of Proportional Damping Structure by Using Modified Dynamic Characteristics)

  • 이정윤
    • 대한기계학회논문집A
    • /
    • 제34권7호
    • /
    • pp.873-879
    • /
    • 2010
  • 일반적으로 설계파라미터 변경에 의한 구조물의 동특성변화를 예측하는 연구에 비해 동특성 변화로부터 변경된 설계파라미터를 예측하는 연구는 잘 알려져 있지 않다. 여기에서는 감도계수와 반복법을 사용하여 비례감쇠계의 변경된 설계파라미터를 예측하였다. 감도계수는 변경에 의한 고유벡터의 변화로부터 구하였다. 이 방법을 3 층 전단 구조물에 적용하여 변경된 설계 파라미터를 예측하였으며 재 해석한 결과와 잘 일치함을 알았다.

비비례 진동감쇠를 갖는 선형 동역학계의 스펙트럴 해석법 (Spectral Analysis Method for the Multi-DOFs Dynamic Systems with Non-Proportional Damping)

  • 조주용;김성환;이우식
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.411-416
    • /
    • 2004
  • This paper introduces a fast Fourier transform (FFT)-based spectral analysis method for the transient responses as well as the steady-state responses of linear dynamic systems with non-proportional damping. The force vibration of a non-proportionally damped three-DOF system is considered as the illustrative numerical example. The proposed spectral analysis method is evaluated by comparing with the numerical solution obtained by the Runge-Kutta method

  • PDF

고조파 공진 억제를 위한 완충부하 투입량 분석에 관한 연구 (A Study on the Analysis of Damping Loads to Prevent Harmonic Resonance)

  • 임찬호;이경섭;유원근;이흥재
    • 전기학회논문지
    • /
    • 제59권2호
    • /
    • pp.262-266
    • /
    • 2010
  • During the restoration process of primary restorative transmission system, the over voltage may happen due to nonlinear interaction between the unloaded transformer and the transmission system. This over voltage is caused by harmonic resonance and can be prevented by damping loads that are connected before restoration process of primary restorative transmission system. But it is very difficult to predict the occurrence possibility of the harmonic resonance previously. This paper analyzes the relationship between the harmonic resonance and the amount of damping loads to prevent the harmonic resonance. This paper calculates the minimum amount of damping loads to prevent harmonic resonance while changing the length of primary restorative transmission line. And this paper confirmed that the amount of damping loads is not proportional to length of transmission line. The result of this paper will be used as important experiment data to predict the occurrence possibility of harmonic resonance previously.

변위비례식 마찰댐퍼의 특성에 관한 연구 (A Study on the Characteristics of an Amplitude Proportional Friction Damper)

  • 박동훈;최명진
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.717-720
    • /
    • 2002
  • An Amplitude Proportional Friction Damper (APFD) system is considered in order to improve the stick-slip characteristics of Coulomb friction damper. The frictional force is proportional to the amplitude in APFD system and the system is non-linear as is Coulomb damper system. The free vibration analysis on an 1-DOF system has conducted to demonstrate the characteristics of the APFD system and the results show that the APFD system has similar damping characteristics to the viscous damper system. It is concluded that the APFD system may become a cost effective substitution for the viscous damper and it also has certain advantages over Coulomb damper system since the APFD system can be designed to work with no stick-slip.

  • PDF

감쇠를 포함한 유한요소 모형의 개선 (Updating of Finite Element Models Including Damping)

  • 이건명;주영호;박문수
    • 한국소음진동공학회논문집
    • /
    • 제22권12호
    • /
    • pp.1243-1249
    • /
    • 2012
  • 이 논문에서 유한요소 모형은 2단계로 개선된다. 첫 단계에서는 감쇠를 무시하고, 최적화 방법을 사용하여 유한요소 모형의 질량행렬과 강성행렬을 개선한다. 최적화를 위한 목적함수는 모드시험 데이터와 유한요소해석으로부터 구한 고유진동수와 진동형으로 이루어져 있다. 두 번째 단계에서는 첫 단계에서 구한 질량행렬과 강성행렬을 고정시키고, 감쇠를 고려한다. 먼저 비례감쇠를 가정하고 감쇠행렬을 추정한 다음, 해석적인 주파수응답함수와 측정한 주파수응답함수의 차가 최소가 되도록 최적화 과정을 이용하여 감쇠행렬을 조정한다. 이와 같은 모형개선 방법을 시뮬레이션 계와 실제 외팔보에 적용하였다.