• 제목/요약/키워드: Profile Curve

검색결과 381건 처리시간 0.034초

Search of Characteristic for Dose Distribution Presented by Multi­isocentric Stereotactic Radiosurgical Plan Using Linear Accelerator (선형 가속기를 이용한 정위적 방사선 수술시 병소내 선량분포의 특성조사)

  • 최경식;오승종;이형구;최보영;전흥재;서태석
    • Progress in Medical Physics
    • /
    • 제14권4호
    • /
    • pp.225-233
    • /
    • 2003
  • The goal of a radiation treatment plan is to deliver a homogeneous dose to a target with minimal irradiation of the adjacent normal tissues. Dose uniformity is especially important for stereotactic radiosurgery using a linear accelerator. The dose uniformity and high dose delivery of a single spherical dose distribution exceed 70%. This also results with a similar stereotactic radiosurgical plan using a Gamma Knife. The dose distribution produced in a stereotactic radiosurgical plan using a Gamma Knife and Linear accelerator is spherical, and the application of the sphere packing arrangement in a real radiosurgical plan requires much time and skill. In this study, we found a characteristic of dose distribution with transformation of beam parameters that must be considered in a radiosurgical plan for effective radiosurgery. First, we assumed a cylinder type tumor model and a cube type tumor model. Secondly, the results of the tumor models were compared and analyzed with dose profiles and DVH_(Dose Volume Histogram) representative dose distribution. We found the optimal composition of beam parameters_(i.e. collimator size, number of isocenter, gap of isocenters etc.), which allowed the tumor models to be involved in the isodose curve at a high level. In conclusion, the characteristics found in this study are helpful for improving the effectiveness and speed of a radiosurgical plan for stereotactic radiosurgery.

  • PDF

Dosimetric Characteristics of the KCCH Neutron Therapy Facility (원자력병원 중성자선치료기의 물리적특성)

  • Yoo Seong Yul;Noh Sung Woo;Chung Hyun Woo;Cho Chul Koo;Koh Kyoung Hwan;Bak Joo Shik;Eenmaa Juri
    • Radiation Oncology Journal
    • /
    • 제6권1호
    • /
    • pp.85-91
    • /
    • 1988
  • For the physical characterization of neutron beam, dosimetric measurements had been performed to obtain physical data of KCCH cyclotron-produced neutrons for clinical use. The results are presented and compared with the data of other institutions from the literatures. The central axis percent depth dose, build-up curves and open and wedge isodose curve values are intermediate between that of a 4 and 6 MV X-rays. The build-up level of maximum dose was at 1.35cm and entrance dose was approximately $40\%$. Flatness of the beam was $9\%$ at Dmax and less $than{\pm}3\%$ at the depth of $80\%$ isodose line. Penumbra begond the $20\%$ line is wider than corresponding photon beam. The output factors ranged 0.894 for $6\times6cm$ field to 1.187 for $30\times30cm$ field. Gamma contamination of neutron beam was $4.9\%$ at 2 cm depth in $10\times10cm$ field.

  • PDF

Determination of an Effective Wedge Angle by Combination of Two Arbitrary Universal Wedge Fields in Radiation Therapy of Cancer Patients with Megavoltage Photon Beams

  • Shamsi, Azin;Birgani, Mohammad Javad Tahmasebi;Behrooz, Mohammad Ali;Arvandi, Sholeh;Fatahiasl, Jafar;Maskny, Reza;Abdalvand, Neda
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권1호
    • /
    • pp.197-200
    • /
    • 2016
  • Background: Wedge filters are commonly used in radiation oncology for eliminating hot spots and creating a uniform dose distribution in optimizing isodose curves in the target volume for clinical aspects. These are some limited standard physical wedges ($15^{\circ}$, $30^{\circ}$, $45^{\circ}$, $60^{\circ}$),or creating an arbitrary wedge angle, like motorized wedge or dynamic wedge,${\ldots}$ The new formulation is presented by the combination of wedge fields for determining an arbitrary effective wedge angles. The isodose curves also are derived for these wedges. Materials and Methods: we performed the dosimetry of Varian Clinac 2100C/D with Scanditronix Wellhofer water blue phantom, CU500E, OmniPro - Accept software and 0.13cc ionization chamber for 6Mv photon beam in depth of 10cm (reference depth) for universal physical wedges ($15^{\circ}$, $30^{\circ}$, $45^{\circ}$, and $60^{\circ}$) and reference field $10.10cm^2$. By combining the isodose curve standard wedge fields with compatible weighting dose for each field, the effective isodose curve is calculated for any wedge angle. Results: The relation between a given effective wedge angle and the weighting of each combining wedge fields was derived. A good agreement was found between the measured and calculated wedge angles and the maximum deviation did not exceed $3^{\circ}$. The difference between the measured and calculated data decreased when the combined wedge angles were closer. The results are in agreement with the motorized single wedge appliance in the literature. Conclusions: This technique showed that the effective wedge angle that is obtained from this method is adequate for clinical applications and the motorized wedge formalism is a special case of this consideration.

Verification of Dose Distribution for Stereotactic Radiosurgery with a Linear Accelerator (선형가속기를 이용한 방사선 수술의 선량분포의 실험적 확인)

  • Park Kyung Ran;Kim Kye Jun;Chu Sung Sil;Lee Jong Young;Joh Chul Woo;Lee Chang Geol;Suh Chang Ok;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • 제11권2호
    • /
    • pp.421-430
    • /
    • 1993
  • The calculation of dose distribution in multiple arc stereotactic radiotherapy is a three-dimensional problem and, therefore, the three-dimensional dose calculation algorithm is important and the algorithm's accuracy and reliability should be confirmed experimentally. The aim of this study is to verify the dose distribution of stereotactic radiosurgery experimentally and to investigate the effect of the beam quality, the number of arcs of radiation, and the tertiary collimation on the resulting dose distribution. Film dosimetry with phantom measurements was done to get the three-dimensional orthogonal isodose distribution. All experiments were carried out with a 6 MV X-ray, except for the study of the effects of beam energy on dose distribution, which was done for X-ray energies of 6 and 15 MV. The irradiation technique was from 4 to 11 arcs at intervals of from 15 to 45 degrees between each arc with various field sizes with additional circular collimator. The dose distributions of square field with linear accelerator collimator compared with the dose distributions obtained using circular field with tertiary collimator. The parameters used for comparing the results were the shape of the isodose curve, dose fall-offs fom $90\%$ to $50\%$ and from $90\%\;to\;20\%$ isodose line for the steepest and shallowest profile, and $A=\frac{90\%\;isodose\;area}{50\%\;isodose\;area-90\%\;isodose\;area}$(modified from Chierego). This ratio may be considered as being proportional to the sparing of normal tissue around the target volume. The effect of beam energy in 6 and 15 MV X-ray indicated that the shapes of isodose curves were the same. The value of ratio A and the steepest and shallowest dose fall-offs for 6 MV X-ray was minimally better than that for 15 MV X-ray. These data illustrated that an increase in the dimensions of the field from 10 to 28 mm in diameter did not significantly change the isodose distribution. There was no significant difference in dose gradient and the shape of isodose curve regardless of the number of arcs for field sizes of 10, 21, and 32 mm in diameter. The shape of isodose curves was more circular in circular field and square in square field. And the dose gradient for the circular field was slightly better than that for the square field.

  • PDF

A Critical Review On the Profiles of Korean Female Labor Force: 1960-2000 (한국 여성노동력의 성격변화와 노동정책: 1960-2000)

  • Kim, Mi-Sok
    • Korea journal of population studies
    • /
    • 제29권1호
    • /
    • pp.133-156
    • /
    • 2006
  • This paper tries to explore the overall profile of Korean female labor force over the period of 1960-2000. A particular emphasis is put on portraying major over-time characteristics of female labor force, following five different political regimes--that of Park, J.H.(1960 and 1970s), of Chon D.H. (early and late 1980s), of Roh T.W. (late 1980-early 1990s), of Kim,Y.S. (early 1990-1ate 1990s), and of Kim. D. J. (late 1990-early 2000s), respectively. Discussions have centered around: 1) utilization of young single girls from rural areas during the early industrialization process of 1960-1985; 2) the beginning of married women's entry into labor market and issues of the socalled &M-curve& thesis in Korean experiences since 1990s; 3) the emergence and enlargement of non-regular workers; and 4) the launching of labor related legal measures such as the Equal Employment Act of 1988 and its successive revisions, the Maternity Leave Acts, the On-the-Job Chi1dcare Centers, and the prohibition of sexual harassments on the job setting, and so on. All in all, although it is undeniable that the Korean female labor force has experienced much progress over the period of time in terms of &equality and protection& issues, overall industrial reality we are facing with has not been so prosperous in the sense that most women workers have become the victims of industrial polarization, as time goes by.

Application of Analysis Models on Soil Water Retention Characteristics in Anthropogenic Soil (인위적으로 변경된 토양에서의 수분보유특성 해석 모형의 적용)

  • Hur, Seung-Oh;Jeon, Sang-Ho;Han, Kyung-Hwa;Jo, Hee-Rae;Sonn, Yeon-Kyu;Ha, Sang-Keun;Kim, Jeong-Gyu;Kim, Nam-Won
    • Korean Journal of Soil Science and Fertilizer
    • /
    • 제43권6호
    • /
    • pp.823-827
    • /
    • 2010
  • This study was conducted to assess the propriety of models for soil water characteristics estimation in anthropogenic soil through the measurement of soil water content and soil water matric potential. Soil profile was characterized with four different soil layers. Soil texture was loamy sand for the first soil layer (from soil surface to 30 cm soil depth), sand for the second (30~70 cm soil depth) and the third soil layers (70~120 cm soil depth), and sandy loam for the fourth soil layer (120 cm < soil depth). Soil water retention curve (SWRC), the relation between soil water content and soil water matric potential, took a similar trend between different layers except the layer of below 120 cm soil depth. The estimation of SWRC and air entry value was better in van Genuchten model by analytical method than in Brooks-Corey model with power function. Therefore, it could be concluded that van Genuchten model is more desirable than Brook-Corey model for estimating soil water characteristics of anthropogenic soil accumulated with saprolite.

Key Exchange Protocols for Domestic Broadband Satellite Access Network (광대역 위성 엑세스 방을 위한 키 교환 프로토콜 제안)

  • 오흥룡;염흥열
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • 제14권3호
    • /
    • pp.13-25
    • /
    • 2004
  • The key exchange protocols are very crucial tools to provide the secure communication in the broadband satellite access network. They should be required to satisfy various requirements such as security, key confirmation, and key freshness. In this paper, we present the guideline of security functions in BSAN(Broadband Satellite Access Network), and analyze the specification of the security primitives and the hey exchange Protocols for the authenticated key agreement between RCST(Return Channel Satellite Terminal) and NCC(fretwork Control Centre). In addition, we propose the security specification for a domestic broad satellite network based on the analysis on the analysis profile of ETSI(European Telecommunications Standards Institute) standards. The key exchange protocols proposed in ETSI standard are vulnerable to man-in-the-middle attack and they don't provide key confirmation. To overcome this shortcoming, we propose the 4 types of the key exchange protocols which have the resistant to man-in-the-middle-attack, key freshness, and key confirmation, These proposed protocols can be used as a key exchange protocol between RCST and NCC in domestic BSAN. These proposed protocols are based on DH key exchange protocol, MTI(Matsumoto, Takashima, Imai) key exchange protocol, and ECDH(Elliptic Curve Diffie-Hellman).

The Pharmacokinetics of Erythromycin in Cultured Paralichthys olivaceus after Oral administration (경구투여에 의한 양식산 넙치내 Erythromycin의 약물동태학적 특성 분석)

  • Seo, Jung-Soo;Jeon, Eun-Ji;Jung, Sung-Hee;Park, Myung-Ae;Kim, Na-Young
    • Journal of Fisheries and Marine Sciences Education
    • /
    • 제26권2호
    • /
    • pp.316-321
    • /
    • 2014
  • The pharmacokinetics of erythromycin (EM) after oral administration was studied in the cultured olive flounder, Paralichthys olivaceus, using LC/MS/MS. After single- or multiple-dose administration of EM (50, 100, 200 mg/kg body weight and 50 mg/kg for 5 days) by oral route in olive flounder ($350{\pm}40g$, $22{\pm}0.5^{\circ}C$), the concentration in the serum was determined at 1, 3, 6, 9, 24, 72, 120, 168, 264, 360, 504 and 720 h post-dose. The kinetic profile of absorption, distribution and elimination of EM in serum were analyzed fitting to a two-compartment model by WinNonlin program. The area under the concentration-time curve (AUC), maximum concentration ($C_{max}$), time for maximum concentration ($T_{max}$) following oral administration of 50, 100 and 200 mg/kg b.w. and 50 mg for 5 days. EM was $165.3hr^*{\mu}g/m{\ell}$ ($C_{max}$, $34.63{\mu}g/m{\ell}$; $T_{max}$, 1.56 hr), $212.8hr^*{\mu}g/m{\ell}$ ($C_{max}$, $60.38{\mu}g/m{\ell}$; $T_{max}$, 3.99 hr), and $592.37hr^*{\mu}g/m{\ell}$ ($C_{max}$, $63.01{\mu}g/m{\ell}$; $T_{max}$, 4 hr), respectively. The results of this study related to dosage and ${\mu}{\cdot}$withdrawal times could be used for prescription of EM in field for the treatment of bacterial diseases in olive flounder.

Potential of Mean Force Calculations for Ion Selectivity in a Cyclic Peptide Nanotube

  • Choi, Kyu-Min;Kwon, Chan-Ho;Kim, Hong-Lae;Hwang, Hyon-Seok
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권3호
    • /
    • pp.911-916
    • /
    • 2012
  • Ion selectivity in a simple cyclic peptide nanotube, composed of four cyclo[-(D-Ala-Glu-D-Ala-Gln)$_2-$] units, is investigated by calculating the PMF profiles of $Na^+$, $K^+$, and $Cl^-$ ions permeating through the peptide nanotube in water. The final PMF profiles of the ions obtained from the umbrella sampling (US) method show an excellent agreement with those from the thermodynamic integration (TI) method. The PMF profiles of $Na^+$ and $K^+$ display free energy wells while the PMF curve of $Cl^-$ features free energy barriers, indicating the selectivity of the cyclic peptide nanotube to cations. Decomposition of the total mean force into the contribution from each component in the system is also accomplished by using the TI method. The mean force decomposition profiles of $Na^+$ and $K^+$ demonstrate that the dehydration free energy barriers by water molecules near the channel entrance and inside the channel are completely compensated for by attractive electrostatic interactions between the cations and carbonyl oxygens in the nanotube. In the case of $Cl^-$, the dehydration free energy barriers are not eliminated by an interaction between the anion and the peptide nanotube, leading to the high free energy barriers in the PMF profile. Calculations of the coordination numbers of the ions with oxygen atoms pertaining to either water molecules or carbonyl groups in the peptide nanotube reveal that the stabilization of the cations in the midplane regions of the nanotube arises from the favorable interaction of the cations with the negatively charged carbonyl oxygens.

Decreased absorption of midazolam in the stomach due to low pH induced by co-administration of Banha-sasim-tang

  • Jo, Jun Hyeon;Kim, Sun Joo;Nam, Woong Shik;Seung, Eun Ji;Lee, Sangkyu
    • Environmental Analysis Health and Toxicology
    • /
    • 제31권
    • /
    • pp.16.1-16.9
    • /
    • 2016
  • Objectives Banha-sasim-tang (BST), which consists of seven different herbs, is one of the most popular herbal formulae for treating gastrointestinal disorders in Eastern Asia. The commonly used herbal medicine is often co-administered with other therapeutic drugs, which raises the possibility of herb-drug interactions and may modify the clinical safety profile of therapeutic drugs. Methods We investigated the potential herb-drug interactions between BST extract and midazolam (MDZ) in mice. The area under the plasma concentration-time curve (AUC) of MDZ and 1'-hydroxymidazolam (1'-OH-MDZ) was evaluated for both oral and intraperitoneal administration of MDZ, following oral administration of BST (0.5 and 1 g/kg). Results It was found that the AUC of MDZ and 1'-OH-MDZ was lower in case of oral administration of MDZ. Administration of BST extract was not associated with hepatic cytochrome P450 activity. BST extract induced a strong reduction in pH and it has been reported that oral mucosal absorption of MDZ is lower at low pH. The decreased absorption rate of MDZ might be caused by the ingredients of BST and may not be related to other factors such as increased excretion of MDZ by P-glycoprotein. Conclusions The altered pharmacokinetics of midazolam caused by co-administration with BST in vivo could be attributed to a decrease in pH and subsequent reduction of MDZ absorption rate.