• Title/Summary/Keyword: Process Cycle Efficiency

Search Result 449, Processing Time 0.032 seconds

Performance Characteristic of the compression-absorption hybrid cycles (흡수압축 하이브리드 사이클의 성능특성)

  • Kim Jae-Man;Kwon Oh-Kyung;Moon Choon-Geun;Seol Won-Sil;Yoon Jung-In
    • 한국가스학회:학술대회논문집
    • /
    • 1998.09a
    • /
    • pp.255-260
    • /
    • 1998
  • This study describes the results of Coefficient Of Performance(COP) analysis by cycle simulation for two types of absorption-compression hybride cycle using the water/Lithium Bromide solution pair, These types are basic hybride systems introducing a mechanical compression process into the refrigerant vapor phase of the single effect absorption cycle. In absorption-compression hybrid cycles, coefficient of performance is improved compared with absorption cycle. Hybride cycle Type ll is considered as a key technology to support energy utilization system, given its capability of utilizing waste heat to drive system with a high level of efficiency.

  • PDF

Experimental Study on the Drying Process in the Two-Cycle Heat Pump Dryer (2-사이클 열펌프 건조기에서 건조과정에 대한 실험적 연구)

  • Lee, Kong-Hoon;Kim, Ook-Joong;Kim, Jong-Ryul;Lee, Sang-Ryoul
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.636-641
    • /
    • 2008
  • Heat pump drying has a great potential for energy saving due to its high energy efficiency in comparison to conventional air drying. The heat pump dryer is usually operated at the temperature less than $50^{\circ}C$ and the drying temperature is limited to the operating temperature of the heat pump system. In order to increase the drying temperature, the special box-type heat pump dryer has been developed. The dryer uses the two-cycle heat pump system which has the two heat pump cycles for high and low temperature heating. The high temperature cycle uses the refrigerant 124 to get the temperature greater than $80^{\circ}C$ and the low temperature cycle uses the refrigerant 134a. The drying experiment has been carried out to figure out the performance of the dryer with the selected drying material.

  • PDF

A Study on the Engineering Design for 250kW-Grade Waste Gas Heat Recovery (250kW급 폐열회수 시스템 공정설계에 관한 연구)

  • Kim, Kyoung Su;Bang, Se Kyoung;Seo, In Ho;Lee, Sang Yun;Jeong, Eun Ik;Yi, Chung Seob
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.5
    • /
    • pp.90-95
    • /
    • 2019
  • This study aims to gain the design data through the process design of the organic Rankine cycle, which can produce 250kW of electric power through waste heat recovery. In this study, a simulation was conducted using APSEN HYSYS to make the model for the process design of the 250kW-class waste heat recovery system. For the thermodynamic model, the test was conducted with hot water as the heat source, the water steam as the cooling water for the cooler, and the refrigerant R245FA in the cycle. In the final design, it was expected and found from the simulation that the cycle efficiency was 12.62% and that 250kW of power was produced considering the margin of 80%.

Performance Analysis of a 50㎾ Turbo-Generator Gas Turbine Engine with a Recuperator (리큐퍼레이터를 고려한 50KW급 터보제너레이터 가스터빈 엔진의 성능해석)

  • 김수용;수다레프
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.3 no.2
    • /
    • pp.48-55
    • /
    • 1999
  • Performance analysis of a 50KW turbo-generator gas turbine engine with a recuperator was studied. Recuperated cycle has been employed to meet maximum fuel economy and ultra low emissions especially for military and vehicular engines. From thermodynamic stand point, it is known that recuperative cycle can contribute most to enhance thermal cycle efficiency for the Pressure ratios under 10 and of comparatively low turbine inlet temperature. Efficiency of a simple cycle with a recuperator increases relatively about 30% than without one at effectiveness of 0.5. Pressure losses in the heat exchanger less than 5.2% is considered in the design process. A tubular type heat exchanger is selected for this particular engine because it can provide simple construction as well as structural sturdiness and excellent leak tightness.

  • PDF

A Study on the Treatment Efficiency of Sequencing Batch Reactor with the Livestock Nightsoil Organic Loading Rate Variance (가축분뇨 유기물질부가별 연속회분식반응조 효율에 관한 연구)

  • 여운호
    • Journal of Environmental Health Sciences
    • /
    • v.21 no.4
    • /
    • pp.32-36
    • /
    • 1995
  • This study was carried out to investigate the treatment efficiency of sequencing batch reactor when the livestock nightsoil organic loading rate was varied. Sequencing batch reactor was operated with the variance of influent BOD concentration and operating cycle. The average influent BOD concentrations in this study were 150 mg/l, 200 mg/l, 250 mg/l, 300 mg/l, 350 mg/l, 400 mg/l, 450 mg/l and 500 mg/l in the condition of 1~3 cycles/day. The treatment efficiency of sequencing batch reactor is good at the volumetric loading of 0.05~0.20 kg $BOD/m^3\cdot day$. Therefore, sequencing batch reactor process would become an effective alternative for the process of small scale livestock nightsoil treatment plants.

  • PDF

Biological Treatability of Toxic Industrial Wastewater (독성산업폐수의 생물학적 처리)

  • 원성연;박승국;정근욱
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.4
    • /
    • pp.172-179
    • /
    • 1999
  • In this research, biological treatability test was conduced using seawater flocculated tannery wastewater by fixed biofilm reactor. During one cycle, the removal efficiency of organic corbon obtained with fixed biofilm process for treating tannery wastewater was considerably greater than that with activated sludge process. As the hydraulic retention time increased form 0.5day to 4day, removal efficiency of organic carbon was increased from 72% to 87.3%. Attached biomass in media increased with influent organic loading up to 29g MLSS/L, that could reduce the specific organic loading rate. The continual measurement of attached biomass was possible for the operation of the biofilm reactor. Equal and low nitrication rates were observed in both suspended growth activated sludge process and fixed biofilm process, despite commercial nitrifier was seeded. Through the process of treating the tannery wastewater, EC50 values which is measured by the use of Ceriopdaphnia dubia, were decreased to the extent of 50% after treatment of seawater flocculation and of 83% after biological treatment, respectively, compared to those of the untreated wastewater.

  • PDF

A Study on Fault Detection of Cycle-based Signals using Wavelet Transform (웨이블릿을 이용한 주기 신호 데이터의 이상 탐지에 관한 연구)

  • Lee, Jae-Hyun;Kim, Ji-Hyun;Hwang, Ji-Bin;Kim, Sung-Shick
    • Journal of the Korea Society for Simulation
    • /
    • v.16 no.4
    • /
    • pp.13-22
    • /
    • 2007
  • Fault detection of cycle-based signals is typically performed using statistical approaches. Univariate SPC using few representative statistics and multivariate analysis methods such as PCA and PLS are the most popular methods for analyzing cycle-based signals. However, such approaches are limited when dealing with information-rich cycle-based signals. In this paper, process fault defection method based on wavelet analysis is proposed. Using Haar wavelet, coefficients that well reflect the process condition are selected. Next, Hotelling's $T^2$ chart using selected coefficients is constructed for assessment of process condition. To enhance the overall efficiency of fault detection, the following two steps are suggested, i.e. denoising method based on wavelet transform and coefficient selection methods using variance difference. For performance evaluation, various types of abnormal process conditions are simulated and the proposed algorithm is compared with other methodologies.

  • PDF

Development of 1MW Organic Rankine Cycle System (1 MW급 유기랭킨 사이클 시스템 개발)

  • 박흥수;조한창;이용국
    • Journal of Energy Engineering
    • /
    • v.10 no.4
    • /
    • pp.318-326
    • /
    • 2001
  • To enhance thermal efficiency of thermal facility through recovery of low and medium temperature waste heat, 1 MW organic Rankine cycle system was designed and developed. The exhaust gases of 175$^{\circ}C$ at two 100 MW power plants in pohang steel works were selected as the representative of low and medium temperature waste heat in industrial process for the heat source of the organic Rankine cycle system. HCFC-123, a kind of harmless refrigerant, was chosen as the working fluid for Rankine cycle. The organic Rankine cycle system with selected exhaust gases and working fluid was designed and constructed. From the operation, it was confirmed that the organic Rankine cycle system is available for low and medium temperature waste heat recovery in industrial process. The optimum operating manuals, such as heat-up of hot water, turbine start-up, and the process of electric power generation, were derived. However, electric power generated was not 1 MW as designed but only 670 kW. It is due to deficiency of pump capacity for supply of HCFC-123. So it is necessary to increase the pump capacity or to decrease the pressure loss in pipe for more improved HCFC-123 supply.

  • PDF

Low Area and High Performance Multi-mode 1D Transform Block Design for HEVC (HEVC를 위한 저면적 고성능 다중 모드 1D 변환 블록 설계)

  • Kim, Ki-Hyun;Ryoo, Kwang-Ki
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.1
    • /
    • pp.78-83
    • /
    • 2014
  • This paper suggest an effective idea to implement an low area multi-mode one dimension transform block of HEVC(High Efficiency Video Coding). The time consuming multiplier path is designed to operate on low frequency. Normal multipliers dealing with variable operands are replaced with smaller constant multipliers which do the product with constant coefficient and variable only using shifters and adders. This scheme increases total multiplier counts but entire areas are reduced owing to smaller area of constant multiplier. Idle cycles caused by doubled multipliers enable to use multi-cycle paths on the cycle eating multiplier data path. Operating frequency is lowered by multi-cycle path but total throughput is maintained. This structure is implemented with TSMC 0.18 CMOS process library, and operated on 186MHz frequency to process a 4k($3840{\times}2160$) image. Max operating frequency is 300MHz.

Design of Non-flammable Mixed Refrigerant Joule-Thomson Refrigerator for Semiconductor Etching Process (반도체 식각공정을 위한 비가연성 혼합냉매 줄톰슨 냉동기 설계)

  • Lee, Cheonkyu;Kim, Jin Man;Lee, Jung-Gil
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.2
    • /
    • pp.144-149
    • /
    • 2022
  • A cryogenic Mixed Refrigerant Joule-Thomson refrigeration cycle was designed to be applied to the semiconductor etching process with non-flammable constituents. 3-stage cascade refrigerator, single mixed refrigerant Joule-Thomson refrigerator, and 2-stage cascade type mixed refrigerant Joule-Thomson refrigerator are analyzed to figure out the coefficient of performance. Non-flammable mixture of argon(Ar), tetrafluoromethane(R14), trifluoromethane (R23) and octafluoropropane(R218) were utilized to analyze the refrigeration cycle efficiency. The designed refrigeration cycle was adapted to cool down the coolant of HFE7200(Ethoxy-nonafluorobutane, C4F9OC2H5) with certain constraints. Maximum coefficient of performance of the refrigeration system is obtained as 0.289 for the cooling temperature lower than -100℃. The detailed result of the coefficient of performance according to the mixture composition is discussed in this study.