• 제목/요약/키워드: Process Control Displays

검색결과 59건 처리시간 0.031초

Dual Autostereoscopic Display Platform for Multi-user Collaboration with Natural Interaction

  • Kim, Hye-Mi;Lee, Gun-A.;Yang, Ung-Yeon;Kwak, Tae-Jin;Kim, Ki-Hong
    • ETRI Journal
    • /
    • 제34권3호
    • /
    • pp.466-469
    • /
    • 2012
  • In this letter, we propose a dual autostereoscopic display platform employing a natural interaction method, which will be useful for sharing visual data with users. To provide 3D visualization of a model to users who collaborate with each other, a beamsplitter is used with a pair of autostereoscopic displays, providing a visual illusion of a floating 3D image. To interact with the virtual object, we track the user's hands with a depth camera. The gesture recognition technique we use operates without any initialization process, such as specific poses or gestures, and supports several commands to control virtual objects by gesture recognition. Experiment results show that our system performs well in visualizing 3D models in real-time and handling them under unconstrained conditions, such as complicated backgrounds or a user wearing short sleeves.

용액공정을 이용한 열처리된 산화아연 박막의 투명한 박막 트랜지스터 구현을 위한 전사방법 개발 (Development of Transfer Method for Transparent Thin Film Transistor of Heat-treated Zinc Oxide Thin Film by Solution Process)

  • 권순열;정동건;최영찬;이재용;공성호
    • 반도체디스플레이기술학회지
    • /
    • 제17권2호
    • /
    • pp.57-60
    • /
    • 2018
  • Recently, Thin-film transistors (TFTs) are fundamental building blocks for state-of-the-art microelectronics, such as flat-panel displays and system-on-glass. Zinc oxide thin films have the advantage that they can grow at low temperature and can obtain high charge movility. Also the zinc oxide thin film can be used to control the resistance according to the oxygen content, so it is very easy to obtain the desired physical properties. In this paper, we fabricated a zinc oxide thin film on a polished copper substrate through a solution process, then improved the crystallinity through a geat treatment porcess, and studied to transfer it on a flexible substrate after the heat treatment was completed.

방공작전 예비체계의 QoS 지원 (QoS Support in the Air Defense Alternative System)

  • 심동섭;이영란;김기형
    • 한국군사과학기술학회지
    • /
    • 제13권5호
    • /
    • pp.903-909
    • /
    • 2010
  • ADAS is the air defense control system performing air surveillance and identification of ROK and near air. This system is self-developed by Air Force, currently operated successfully as the alternative system of MCRC. ADAS processes converting and combining transferred the real time radar data detected by radars. additionally, it displays significant radar data as producing in tracks. Then, it uses the message queue for IPC(Inter Process Communication). the various tactical data processed in the server is ultimately send to the network management process through the message queue for transmitting to the weapon director console. the weapon director receives this transmitted tactical data through the console to execute air defense operations. However, there is a problem that data packet is delayed or lost since the weapon Director does not receive as the amount of tactical data from the server overflowed with air tracks and missions increased. This paper improved the algorism to display and transmit the various tactical data processed from ADAS server to numbers of the weapon director console in the real time without any delay or lost. Improved the algorism, established at exercise, the development server in the real operation network and the weapon director console, is proved by comparing the number of sending tactical data packets in the server and receiving packets in the weapon director.

Effects of Hole Transport Layer Using Au-ionic Doping SWNT on Efficiency of Organic Solar Cells

  • Min, Hyung-Seob;Jeong, Myung-Sun;Choi, Won-Kook;Kim, Sang-Sig;Lee, Jeon-Kook
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.434-434
    • /
    • 2012
  • Despite recent efforts for fabricating flexible transparent conducting films (TCFs) with low resistance and high transmittance, several obstacles to meet the requirement of flexible displays still remain. Indium tin oxide (ITO) thin films, which have been traditionally used as the TCFs, have a serious obstacle in TCFs applications. SWNTs are the most appropriate materials for conductive films for displays due to their excellent high mechanical strength and electrical conductivity. Recently, it has been demonstrated that acid treatment is an efficient method for surfactant removal. However, the treatment has been reported to destroy most SWNT. In this work, the fabrication by the spraying process of transparent SWNT films and reduction of its sheet resistance by Au-ionic doping treatment on PET substrates is researched. Arc-discharge SWNTs were dispersed in deionized water by adding sodium dodecyl sulfate (SDS) as surfactant and sonicated, followed by the centrifugation. The dispersed SWNT was spray-coated on PET substrate and dried on a hotplate. When the spray process was terminated, the TCF was immersed into deionized water to remove the surfactant and then it was dried on hotplate. The TCF film was then was doped with Au-ionic doping treatment, rinsed with deionized water and dried. The surface morphology of TCF was characterized by field emission scanning electron microscopy. The sheet resistance and optical transmission properties of the TCF were measured with a four-point probe method and a UV-visible spectrometry, respectively. This was confirmed and discussed on the XPS and UPS studies. We show that 87 ${\Omega}/{\Box}$ sheet resistances with 81% transmittance at the wavelength of 550 nm. The changes in electrical and optical conductivity of SWNT film before and after Au-ionic doping treatments were discussed. The effects of hole transport interface layer using Au-ionic doping SWNT on the performance of organic solar cells were investigated.

  • PDF

Discomfort Analysis in Computerized Numeric Control Machine Operations

  • Muthukumar, Krishnamoorthy;Sankaranarayanasamy, Krishnasamy;Ganguli, Anindya Kumar
    • Safety and Health at Work
    • /
    • 제3권2호
    • /
    • pp.146-153
    • /
    • 2012
  • Objectives: The introduction of computerized numeric control (CNC) technology in manufacturing industries has revolutionized the production process, but there are some health and safety problems associated with these machines. The present study aimed to investigate the extent of postural discomfort in CNC machine operators, and the relationship of this discomfort to the display and control panel height, with a view to validate the anthropometric recommendation for the location of the display and control panel in CNC machines. Methods: The postural discomforts associated with CNC machines were studied in 122 male operators using Corlett and Bishop's body part discomfort mapping, subject information, and discomfort level at various time intervals from starting to end of a shift. This information was collected using a questionnaire. Statistical analysis was carried out using ANOVA. Results: Neck discomfort due to the positioning of the machine displays, and shoulder and arm discomfort due to the positioning of controls were identified as common health issues in the operators of these machines. The study revealed that 45.9% of machine operators reported discomfort in the lower back, 41.8% in the neck, 22.1% in the upper-back, 53.3% in the shoulder and arm, and 21.3% of the operators reported discomfort in the leg. Conclusion: Discomfort increased with the progress of the day and was highest at the end of a shift; subject age had no effect on patient tendency to experience discomfort levels.

저온 선택적 원자층 증착공정을 이용한 유기태양전지용 AZO 투명전극 제조에 관한 실험적 연구 (Experimental Study on Fabrication of AZO Transparent Electrode for Organic Solar Cell Using Selective Low-Temperature Atomic Layer Deposition)

  • 김기철;송근수;김형태;유경훈;강정진;황준영;이상호;강경태;강희석;조영준
    • 대한기계학회논문집B
    • /
    • 제37권6호
    • /
    • pp.577-582
    • /
    • 2013
  • AZO(Aluminium-doped Zinc Oxide)는 기존의 LCD, OLED, 광센서, 유기태양전지 등의 투명전극에 널리 사용되는 ITO(Indium Tin Oxide)를 대체하기 위한 물질로 주목받고 있다. 본 연구에서는 유기태양전지의 투명 전극으로 많이 사용되는 ITO 를 대체하기 위해 원자층 증착(ALD) 공정의 저온 선택적 증착 특성을 이용하여 유연성 폴리머인 PEN 기판상에 AZO 투명전극을 직접 패턴방식으로 제조하고, 그 투명전극의 구조적, 전기적, 광학적 특성을 평가하였다. 전기적, 광학적 특성 결과들로부터 원자층 증작공정의 저온 선택적 증착 특성을 통해 형성된 AZO 투명전극의 유기태양전지로의 적용 가능성을 확인할 수 있었다.

Emission Characteristics of 0.7' Monochrome MOSFET-Controlled Field Emission Display in a High Vacuum Chamber

  • Lee, Jong-Duk;Oh, Chang-Woo;Kim, Il-Hwan;Park, Jae-Woo;Park, Byung-Gook
    • Journal of Information Display
    • /
    • 제2권3호
    • /
    • pp.66-71
    • /
    • 2001
  • MCFEDs (MOSFET-Contoolled Field Emission Displays) were fabricated to evaluate the validity of MCFEA for display application. The electrical properties of FEAs (Field Emitter Arrays), HVMOSFETs (High-Voltage MOSFETs), and MCFEAs (MOSFET-Controlled Field Emitter Arrays) were measured. The extraction gate voltage of the FEAs to obtain the anode current of 10 nA/tip was around 71 V. The breakdown voltages of the HVMOSFETs were above 81 V for all the samples. The I-V characteristics of the MCFEAs showed that the emission currents of the FEAs were well controlled depending on the control gate voltages of the HVMOSFETs. To avoid the harmful effects during the packaging process, the performance of the MCFEDs was evaluated in a high vacuum chamber. The emission images of the MCFEDs were controlled through very-through operation. From the comparison with a conventional FED, it was proven that the poor uniformity of FED could be improved through the integration with HVMOSFET.

  • PDF

Bone Regeneration in the Extraction Socket Filled with Atelocollagen: Histological and Radiographic Study in Beagle Dogs

  • Lee, Hyeonjong;Noh, Kwantae;Lee, Deok-Won
    • Journal of Korean Dental Science
    • /
    • 제9권2호
    • /
    • pp.55-62
    • /
    • 2016
  • Purpose: Alveolar bone develops with tooth eruption and is absorbed following tooth extraction. Various ridge preservation techniques have sought to prevent ridge atrophy, with no superior technique evident. Collagen has a long history as a biocompatible material. Its usefulness and safety have been amply verified. The related compound, atelocollagen, is also safe and displays reduced antigenicity since telopeptides are not present. Materials and Methods: The current study evaluated whether the $Rapiderm^{(R)}$ atelocollagen plug (Dalim Tissen, Seoul, Korea) improves tissue healing of extraction sockets and assessed the sequential pattern of bone regeneration using histology and microcomputed tomography in six beagle dogs. To assess the change of extraction socket, hard tissues were examined 2, 4, 6, and 8 weeks after tooth extraction. Result: The experimental groups showed better bone fill with slow remodeling process compared to the control groups although there was no statistical difference between groups. Conclusion: The atelocollagen seems to have a tendency to slow bone remodeling in the early phase of healing period and maintain remodeling capacity until late phase of remodeling. Also, use of atelocollagen increased the bone-to-tissue ratio compared to healing of untreated extraction socket.

AHP를 이용한 개량형 정보 표시 평가 항목의 중요도 선정에 관한 연구 (The Selection of Human factors Evaluation Criteria for Information Display on VDT using AHP)

  • 차우창;장성필
    • 산업경영시스템학회지
    • /
    • 제27권1호
    • /
    • pp.109-120
    • /
    • 2004
  • In large scale complex system such as a nuclear power plant, it is important to select guidelines and/or checklist to evaluate the system performance, especially human performance for visual information while the number of evaluation items of the guidelines and checklist is voluminous. This paper presents the methodology and experiment for the relative weights or priority selection of evaluation items on the advanced information display of main control room in a nuclear power plant. To summarize this, 1) many human factors guidelines of Visual Display Terminal(VDT) displays are collected, 2) the collected guidelines are integrated and unified based on some rules in a way to avoid confusion or errors about work performances of operator groups, 3) using the unified guidelines, the more important items are defined when the advanced information indexes are applied by using the Analytic Hierarchy Process(AHP). For employing the AHP, the decisions and response of many human factors evaluation specialists in this field are collected to get the priority order of the evaluation items of VDT. The result of this paper will be applied for the evaluation of the usability of next generation of nuclear power plant which is focused on the visual information display on VDT.

이족 보행 로보트를 위한 3차원 모의 실험기의 개발 (Development of 3D simulator for biped robot)

  • 김민수;이보희;김진걸
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.928-931
    • /
    • 1996
  • It is necessary to develop the simulator for the test of stability and torque before the walking experiment of biped robot, because a robot may be damaged in an actual experiment. This thesis deals with the development of three-dimensional simulator for improving efficiency and safety during development and experimentation. The simulator is composed of three parts-solving dynamics, rendering pictures and communicating with the robot. In the first part, the D-H parameter and parameter of links can be loaded from the file and edited in the program. The results are obtained by using the Newton-Euler method and are stored in the file. Through the above process, the proper length of link and driving force can be found by using simulator before designing the robot. The second part is organized so that the user can easily see a specific value or a portion he wants by setting viewing parameters interactively. A robot is also shown as a shaded rendering picture in this part. In the last part, the simulator sends each desired angle of joints to the robot controller and each real angle of joints is taken from the controller and passed to the second part. The safety of the experiment is improved by driving the robot after checking whether the robot can be actuatable or not and whether the ZMP is located within the sole of the foot or not for a specific gait. The state of the robot can be easily grasped by showing the shaded rendering picture which displays the position of the ZMP, the driving force and the shape of robot.

  • PDF