• 제목/요약/키워드: Probe head

검색결과 84건 처리시간 0.021초

KIF26B-AS1 Regulates TLR4 and Activates the TLR4 Signaling Pathway to Promote Malignant Progression of Laryngeal Cancer

  • Li, Li;Han, Jiahui;Zhang, Shujia;Dong, Chunguang;Xiao, Xiang
    • Journal of Microbiology and Biotechnology
    • /
    • 제32권10호
    • /
    • pp.1344-1354
    • /
    • 2022
  • Laryngeal cancer is one of the highest incidence, most prevalently diagnosed head and neck cancers, making it critically necessary to probe effective targets for laryngeal cancer treatment. Here, real-time quantitative reverse transcription PCR (qRT-PCR) and western blot analysis were used to detect gene expression levels in laryngeal cancer cell lines. Fluorescence in situ hybridization (FISH) and subcellular fractionation assays were used to detect the subcellular location. Functional assays encompassing Cell Counting Kit-8 (CCK-8), 5-ethynyl-2'-deoxyuridine (EdU), transwell and wound healing assays were performed to examine the effects of target genes on cell proliferation and migration in laryngeal cancer. The in vivo effects were proved by animal experiments. RNA-binding protein immunoprecipitation (RIP), RNA pulldown and luciferase reporter assays were used to investigate the underlying regulatory mechanisms. The results showed that KIF26B antisense RNA 1 (KIF26B-AS1) propels cell proliferation and migration in laryngeal cancer and regulates the toll-like receptor 4 (TLR4) signaling pathway. KIF26B-AS1 also recruits FUS to stabilize TLR4 mRNA, consequently activating the TLR4 signaling pathway. Furthermore, KIF26B-AS1 plays an oncogenic role in laryngeal cancer via upregulating TLR4 expression as well as the FUS/TLR4 pathway axis, findings which offer novel insight for targeted therapies in the treatment of laryngeal cancer patients.

Determination of Microviscosity and Location of 1,3-Di(1-pyrenyl) propane in Brain Membranes

  • Kang, Jung-Sook;Kang, In-Goo;Yun, Il
    • Archives of Pharmacal Research
    • /
    • 제20권1호
    • /
    • pp.1-6
    • /
    • 1997
  • We determined the microviscosity of synaptosomal plasma membrane vesicles (SPMV) isolated from bovine cerebral cortex and liposomes of total lipids (SPMTL) and phospholipids (SPMPL) extracted from SPMV. Changes in the microviscosity induced by the range and rate of lateral diffusion were measured by the intramolecular excimerization of 1, 3-di(1-pyrenyl)propane (Py-3-Py). The microviscosity values of the direct probe environment in SPMV, SPMTL and SPMPL were 38.17, 31.11 and 27.64 cP, respectively, at$37^{\circ}C$and the activation energies $(E_a)$ of the excimer formation of Py-3-Py in SPMV, SPMTL and SPMPL were 8.236, 7.448 amd 7.025 kcal/mol, respectively. Probe location was measured by polarity and polarizability parameters of the probe Py-3-Py and probe analogues, pyrene, 1-pyrenenonanol and 1-pyrenemethyl-3${\beta}$-hydroxy-22, 23-bisnor-5-cholenate (PMC), incorporated into membranes or solubilized in reference solvents. There existed a good linear relationship between the first absorption peak of the $^1_a$ band and the polarizability parameter $(n^{2}-1)/(2n^{2}+1)$.The calculated refractive index values for SPMV, SPMTL and SPMPL were close to 1.50, which is higher than that of liquid paraffin (n=l.475). The probe location was also determined by using a polarity parameter $(f-1/2f^{I})$. Here f=$({\varepsilon}-1)/(2{\varepsilon}+1)$ is the dielectric constant function and $f^I=(n^2-1)/(2n^2+1)$ is the refractive index function. A correlation existed between the monomer fluorescence intensity ratio and the solvent polarity parameter. The probes incorporated in SPMV, SPMTL, and SPMPL report a polarity value close to that of 1-hexanol $({\varepsilon}=13.29)$. In conclusion, Py-3-Py is located completely inside the membrane, not in the very hydrophobic core, but displaced toward the polar head groups of phospholipid molecules, e.g., central methylene region of aliphatic chains of phospholipid molecules.

  • PDF

이온전류법에 의한 가솔린엔진 연소실 형상별 급속연소효과 연구 (A Study on the Effect of Fast Burn for Different Combustion Chamber Geometries of Gasoline Engine Using an Ion Current Method)

  • 강건용;서승우;정동수;장영준
    • 대한기계학회논문집
    • /
    • 제17권6호
    • /
    • pp.1633-1639
    • /
    • 1993
  • 본 연구에서는 급속연소기술의 가솔린엔진에 적용을 목적으로 흡입과정시 강한 와류(swirl)를 생성하는 마스크부착 헤드(masked shroud head, MSH)형을 급속연 소형으로 제작하여 마스크부착 헤드형에서의 급속연소효과를 이온전류법에 의한 화염 속도를 측정하므로서 규명하려한다. 이온전류는 이온탐침계(ion probe)를 연소실 표면의 두 지점에 설치하여 검출하며, 이온전류 신호를 정성적인 방법으로 검증한 후 표준 헤드형과 마스크부착헤드형을 장착한 엔진에 대해서 화염전파 속도를 비교 측정 한다. 측정된 화염 전파속도는 정확한 연소특성 분석을 위해 각 사이클에서의 값을 표본으로 하는 통계적 방법으로 처리한다.

아몰퍼스 와이어의 ECT probe 적용에 대한 검토 (Application of Amorphous wire to ECT(Eddy Current Testing) Probe)

  • 김영학;신광호;사공건
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 제4회 영호남학술대회 논문집
    • /
    • pp.47-51
    • /
    • 2002
  • ECT(eddy currentign testing) is very effective technique to detect a flaw within a conductor. Co-based amorphous wire was used as a sensor head. The wire has almost 0 magneto-striction and high permeability. An uniform magnetic field was applied to 1mm thick copper plate and $25{\mu}m$ thick aluminum sheet conductor using spiral typed coil The size of the coil has $40mm{\times}40mm$ outer width and $8mm{\times}8mm$ inner width. The copper plate and aluminum sheet has 0.5mm and 0.1mm wide gap, respectively. The frequency range of applied field was 100kHz-600kHz. The induced voltage difference of 2.5mV was obtained in the maximum voltage and minimum one measured across the gap of the 1mm thick conductor. In the case of aluminum sheet, 0.4mV was obtained. From this results, the effectiveness of Co-based amorphous wire was confirmed in the ECT technique.

  • PDF

The cover of an ear thermometer probe as a split-thickness skin graft mold in external auditory canal reconstruction

  • Chae Rim Lee;Sungyeon Yoon;Ji Hun Kim;Jangyoun Choi;Kyoung Ho Park;Deuk Young Oh
    • 대한두개안면성형외과학회지
    • /
    • 제24권4호
    • /
    • pp.198-201
    • /
    • 2023
  • Maintaining the patency of the external auditory canal (EAC) during reconstruction is important because of its physiological role in hearing and immunological protective functions. The curved shape of the EAC presents a challenge when performing a skin graft. One of the key points for a successful skin graft is to ensure compression on the wound bed, and many novel methods, including prefabricated ear molds, have been reported for this purpose. In this study, we present a case of a skin graft performed to reconstruct a skin defect following excision of actinic keratosis in the EAC, using the cover of an ear thermometer probe as a mold for the graft to match the curvature of the EAC. This is an economical and practical method for secure compression dressing of a skin graft in the EAC.

Thin and superthin perforator flap elevation based on preoperative planning with ultrahigh-frequency ultrasound

  • Visconti, Giuseppe;Bianchi, Alessandro;Hayashi, Akitatsu;Cina, Alessandro;Maccauro, Giulio;Almadori, Giovanni;Salgarello, Marzia
    • Archives of Plastic Surgery
    • /
    • 제47권4호
    • /
    • pp.365-370
    • /
    • 2020
  • The ability to directly harvest thin and superthin perforator flaps without jeopardizing their vascularity depends on knowledge of the microsurgical vascular anatomy of each perforator within the subcutaneous tissue up to the dermis. In this paper, we report our experience with ultrahigh-frequency ultrasound (UHF-US) in the preoperative planning of thin and superthin flaps. Between May 2017 and September 2018, perforators of seven patients were preoperatively evaluated by both ultrasound (using an 18-MHz linear probe) and UHF-US (using 48- and 70-MHz linear probes). Thin flaps (two cases) and superthin flaps (five cases) were elevated for the reconstruction of head and neck oncologic defects and lower limb traumatic defects. The mean flap size was 6.5×15 cm (range, 5×8 to 7.5×23 cm). No complications occurred, and all flaps survived completely. In all cases, we found 100% agreement between the preoperative UHF-US results and the intraoperative findings. The final reconstructive outcomes were considered satisfactory by both the surgeon and the patients. In conclusion, UHF-US was found to be very useful in the preoperative planning of thin and superthin free flaps, as it allows precise anticipation of very superficial microvascular anatomy. UHF-US may represent the next frontier in thin, superthin, and pure skin perforator flap design.

어깨의 능동 수축을 동반한 관절가동술이 부리돌기와 위팔뼈 머리 사이의 거리에 미치는 영향 (The Effect of Mobilization Combined with Shoulder Active Contraction of Depth between the Coracoid Process and Humeral Head)

  • 김선민;장상훈
    • 대한정형도수물리치료학회지
    • /
    • 제29권2호
    • /
    • pp.69-75
    • /
    • 2023
  • Purpose: This study examined the distance between the coracoid process and the humeral head using an ultrasonography device when shoulder active contraction were applied according to the guided direction in the end range of shoulder mobilization. This study aims to provide essential data on treating shoulder disease patients. Methods: The subjects of this study were 20 adults with healthy shoulder joints. ultrasonography (US) equipment was used to examine shoulder joint mobilization under two conditions: (1) anteroposterior (AP) joint mobilization and (2) superoinferior (SI) joint mobilization. Shoulder active contraction was assessed in the end range. The distance between the coracoid process and the humeral head was measured. A linear probe was used for US; the frequency was set to 7.5MHz, and the US image display method was set to B-mode. The US measurement values were measured in (1) the starting position, (2) the end range position, and (3) the end range position of the shoulder active contraction, and the moving distance was drawn in a straight line through the US image. The distance was determined as the measurement value, and the average values were compared. Reults: The results were as follows: (1) the measured AP Joint mobilization increased by an average of .52cm from the end range of the joint mobilization with shoulder active contraction; (2) the measured SI Joint mobilization increased by an average of .49cm from the end range of the joint. Conclusion: When shoulder mobilization is applied, the distance between the coracoid process and the humeral head increases when muscle contraction occurs through shoulder active contraction in the end range, according to the therapist's guidance. Therefore, shoulder mobilization combined with shoulder active contraction is an effective treatment method for patients with shoulder injuries.

  • PDF

멸종위기어류 퉁사리의 환경 DNA 분석을 위한 종 특이 마커 개발 (Species-specific Marker Development for Environmental DNA Assay of Endangered Bull-head Torrent Catfish, Liobagrus obesus)

  • 윤봉한;김용휘;성무성;한호섭;한정호;방인철
    • 한국어류학회지
    • /
    • 제34권3호
    • /
    • pp.208-217
    • /
    • 2022
  • 멸종위기어류 퉁사리 Liobagrus obesus를 대상으로 종 특이 프라이머 한 쌍과 프로브를 제작하여 하천수 시료에서 추출된 환경 DNA로부터 퉁사리를 검출할 수 있는 실시간 PCR 분석방법을 개발하고자 하였다. 퉁사리 종 특이 프라이머와 프로브는 미토콘드리아 DNA의 cytochrome b (cytb) 유전자 영역 내에서 국내에 서식하는 65종의 담수어류 간에 단일염기다형성 부위를 고려하여 비교한 후 제작하였다. 실시간 PCR 분석에서 제작한 프라이머 및 프로브는 국내에 서식하는 65종의 담수어류 gDNA를 이용한 특이성 검증 결과, 퉁사리 gDNA에서만 양성으로 나타나 높은 특이성을 보였다. 퉁사리 gDNA의 연속 희석 농도를 이용한 검출한계 분석에서는 0.2 pg까지 검출이 가능한 것으로 나타나 높은 감도를 보였다. 이후, 제작한 프라이머 및 프로브를 사용하여 금강 중·상류 유역의 8개 지점에서 확보한 하천수 시료를 대상으로 실시간 PCR 분석을 수행한 결과, 5개 지점에서 퉁사리의 cytb 유전자가 검출되었으며, 해당 검출 지점들은 현장 조사 당시에 퉁사리가 채집된 3개 지점을 모두 포함하였다. 따라서, 본 연구에서 개발한 퉁사리의 종 특이 프라이머와 프로브를 이용한 실시간 PCR 분석 방법은 하천수 채수로 확보한 환경 DNA로부터 퉁사리의 cytb 유전자를 검출할 수 있어 기존 서식지 모니터링과 더불어 잠재적인 신규 서식지 발굴에 활용될 수 있을 것으로 판단된다.

강아지에서 컨벡스스캐너를 이용한 정상적인 심장구조물의 초음파상 (Ultrasound Imaging of Normal Cardiac Structures with Convex Scanner in Puppies)

  • 정순욱;박희명;한숙희;윤정희;한홍율
    • 한국임상수의학회지
    • /
    • 제11권2호
    • /
    • pp.529-537
    • /
    • 1994
  • Sector scanner which has a conical end is used to image through the intercostal space because heart is protected by the ribs. Cardiac data published all around the world were also obtained by sector scanner. Although scanners being used in every small animal practice and animal hospital at college in Korea include convex ape and linear type, linear type is not appropriate f3r cardiac scan because of a wide contact surface. The purpose of this study is to establish ultrasonographic images of normal cardiac structures by measuring shape, size of reflectable cardiac structure according to restraint position in scanning normal heart of the puppies with 6.5 MHz convex scanner(SonoAce 4500, Medison, Korea) used in our veterinary teaching hospital, Seoul national university. Seventeen male and female puppies considered having healthy hear by X-ray and clinical examination are used feom April to July 1994. Scanning point selection of probe head and the distinction of imaged cardiac structures were accomplished by necropsy and cardiac scanning performed through thoracotomy under general anesthesia. At 10 o'clock position of transducer(at an angle of 30$^{\circ}$ between imaginary line from elbow joint to 3rd sternum and probe head, 60$^{\circ}$ from body surface, 4th intercostal space of right thorax) with the marker of scanner toward the head of dogs right atrium, left atrium and left ventricle were observed in 2, 3, 4, 5 intercostal space(2cm from the sternum) of experimental dog positioned ventrodorsally under general anesthesia. Under these conditions, the numerical values of imaged diastolic hear are as follows : the distance from skin to apex(mean$\pm$S.D) 47.53$\pm$6.94mm, thickness of left ventricular wall 6.00$\pm$1.60mm, length of left ventricle 16.27$\pm$5.31mm, width of left ventricle 15,33$\pm$4.25mm, length of left atrium 12.33$\pm$3.82mm, width of left atrium 11. 33$\pm$3.94mm, length of right atrium 1.00$\pm$2.41mm, width of right atrium 11.21$\pm$2.76mm and the area of left ventricle 270.92$\pm$109.81mm$^2$, area of left atrium 98.00$\pm$41.08mm$^2$, area of right atrium 62.75$\pm$21.04mm$^2$.

  • PDF

가상현실에서의 뇌파측정을 위한 디자인 고찰 및 제안 (The New Design of Brain Measurement System for Immersive Virtual Reality)

  • 김경모;전준현
    • 한국HCI학회논문지
    • /
    • 제12권4호
    • /
    • pp.75-80
    • /
    • 2017
  • 최근 인지과학의 활발한 연구와 기술의 발달로 인해 사회과학분야에서 정신생리학적 연구를 통한 뇌의 다양한 측정과 정교한 분석 기법이 개발 되었다. 그러나 뇌파를 이용한 뉴미디어활용에 관한 연구는 장비들을 장착하는 과정에서의 한계점으로 인해 진행되지 못하였다. 이러한 문제를 극복하고자, 가상현실장비를 착용한 상태에서도 전 영역의 뇌파측정이 가능한 캡을 디자인하고 활용방법을 제안한다.