• Title/Summary/Keyword: Probe Linearity

Search Result 28, Processing Time 0.027 seconds

Implementation of SAR Measurement System with Stationary Probes (Probe 고정형 SAR 측정 시스템)

  • Kim, Jeong-Ho;Gimm, Youn-Myoung
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2005.11a
    • /
    • pp.443-447
    • /
    • 2005
  • The SAR measurement system with stationary probes, presented in this paper, can calculate area SAR value based ell the measured 9 electric field data. By converting obtained area SAR to the volume SAR, the results can be acquired in a few seconds. The system can be very useful tool in the stages of handset development for mobile communication as well as in the handset production line because of its rapid SAR measurement. The system showed good linearity characteristics at 835 MHz of 10 $\sim$ 27 dBm input power range.

  • PDF

Flexure hinge mechanism having amplified rectilinear motion for confocal scanning microscopy using optical section

  • Kwon, Oh-Kyu;Park, Poo-Gyeon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.162.6-162
    • /
    • 2001
  • Confocal scanning microscopy (CSM) is an important instrument in a wide variety of imaging applications because of its ability to provide three-dimensional images of thick, volume specimens. The mechanism for two-dimensional beam scanning and optical sectioning has an important roe in CSM as the three-dimensional profiler. This optical sectioning property arises from the use of a point detector, which serves to attenuate the signals from out-of-focus. The intensity profile for the open loop scanning should be matched with its response for the standard. The non-linearity can be minimized with the optical sectioning or the optical probe of the closed loop control. This paper shows the mathematical expression of the light such as the extinction curve in the optical fields of system using AO deflector, the axial/lateral response experimentally when the error sources change, and the methods of optical sectioning. Thorough design of optical sectioner is crucial to the success of CSM in the field ...

  • PDF

Design of phase tracking feedback compensator for stabilization of single mode fiber-optic Mach-Zehnder interferometer (단일모드 광섬유 Mach-Zehnder간섭계의 안정화를 위한 추적궤환 보상기의 설계)

  • 이기완;오문수;홍봉식
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1989.10a
    • /
    • pp.547-552
    • /
    • 1989
  • Single mode optical fiber interferometeric sensors using phase tracking homodyne detection are typically susceptible to environmentally induced temperature fluctuations and other types of disturbances. In this paper compensator is described, which is a simple and effective phase tracking feedback electronic circuit must be output signal stabilized to achieve maximln sensitivity and linearity of Mach-Zehnder fiber-optic interferomter in the presence of differential phase drift. The phase tracking range of the piezoelectric cylinder in the reference arm is .+-.3.7.pi.rad, and the probe mass about 1 gram in the sensing ann was used for measurements of the gravity acceleration.

  • PDF

Modeling of Inductive Position Sensor and its Analysis (유도형 변위 센서의 모델링 및 해석)

  • 신우철;홍준희;이동주
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.249-252
    • /
    • 1997
  • The resolution of analog sensor is determined by its sensitivity and amplitude of noise. This paper presents modeling of inductive gap sensor base on equivalent magnetic circuit and analysis of sensitivity. The model of inductive gap sensor is verified by the experimental results. Then we can simulate static characteristic of inductive gap sensor using this model. Computer simulation show that sensor's sensitivity and linearity are affected by magnetic flux's leakage and fringing, and that they are affected by shape of sensor probe.

  • PDF

Fabrication of Chitosan-gold Nanocomposites Combined with Optical Fiber as SERS Substrates to Detect Dopamine Molecules

  • Lim, Jae-Wook;Kang, Ik-Joong
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.1
    • /
    • pp.25-29
    • /
    • 2014
  • This research was aimed to fabricate an optical fiber-based SERS substrate which can detect dopamine neurotransmitters. Chitosan nanoparticles (NPs) were firstly anchored on the surface of optical fiber, and then gold layer was subsequently deposited on the anchored chitosan NPs via electroless plating method. Finally, chitosan-gold nanocomposites combined with optical fiber reacted with dopamine molecules of 100-1500 mg/day which is a standard daily dose for Parkinson's disease patients. The amplified Raman signal at $1348cm^{-1}$ obtained from optical fiber-based SERS substrate was plotted versus dopamine concentrations (1-10 mM), demonstrating an approximate linearity of Y = 303.03X + 2385.8 ($R^2$ = 0.97) with narrow margin errors. The optical fiber-based Raman system can be potentially applicable to in-vitro (or in-vivo) detection of probe molecules.

Europium-Enoxacin Complex as Fluorescence Probe for the Determination of Folic Acid in Pharmaceutical and Biological Samples

  • Alam, Al-Mahmnur;Kamruzzaman, Mohammad;Lee, Sang-Hak;Kim, Young-Ho;Min, Kyung
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.9
    • /
    • pp.3055-3060
    • /
    • 2012
  • A simple, rapid and sensitive spectrofluorometric method was developed for the determination of folic acid (FA), based on its quenching effect on the fluorescence intensity of enoxacin (ENX)-europium ($Eu^{3+}$) complex as a fluorescent probe. Fluorometric interaction between ENX-$Eu^{3+}$ complex and FA was studied using UV-visible and fluorescence spectroscopy. The quenched fluorescence intensity at an emission wavelength of 614 nm was proportional to the concentration of FA. Optimum conditions for the determination of FA were investigated. Under optimal conditions, the reduced fluorescence intensity at 614 nm was responded linearly with the concentration of FA. The linearity was maintained in the range of $1.25{\times}10^{-9}$ to $1.50{\times}10^{-7}$ M (R = 0.9986) with the limit of detection ($3S_b/m$) (where $S_b$ is the standard deviation of blank and m is the slop of linear calibration curve) of $6.94{\times}10^{-10}$ M. The relative standard deviation (RSD) for 9 repeated measurements of $1.0{\times}10^{-9}$ M FA was 1.42%. This method was simple, cost effective, and relatively free of interference from coexisting substances. Successful determinations of FA in pharmaceutical formulation and biological samples with the developed method were demonstrated.

A Development of Eddy Current Sensor System for An Axial-flow type Blood Pump with The Magnetic Bearing (축류형 인공심장의 자기베어링 제어를 위한 와전류 센서 시스템 개발)

  • Ahn, C.B.;Moon, K.C.;Jeong, G.S.;Nam, K.W.;Lee, J.J.;Sun, K.
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.310-315
    • /
    • 2007
  • The axial-flow type blood pump(XVAD) which has been developed in our group consists of mechanical parts (an impeller, a diffuser and a flow straightener) and electrical parts (a motor and a magnetic bearing). The magnetic bearing system fully levitates the impeller to remove mechanical coupling with other parts of the pump with constant gap, which needs non-contact type gap sensing. Conventional gap sensors are too large to be adopted to the implantable axial -flow type blood pump. Thus, in this paper, the compact eddy current type gap sensor system proper for the implantable axial-flow type blood pump was developed and its performance was evaluated in vitro. The developed eddy current type gap sensor system is a transformer type and has a differential probe. Sensor coil(probe) has small dimensions(6 mm diameter, 2 mm thickness) and its optimal inductance was determined as 0.068 mH for the measurement range of $0\sim3mm$. It could be manufactured with 130 turns of the 0.04 mm diameter copper coil. The characteristics of the developed eddy current type gap sensor system was evaluated by in vitro experiment. At experiment, it showed satis(actory performance to apply to the magnetic bearing system of the XVAD. It could measure the gap up to 3mm, but the linearity was decreased at the range of $1.8\sim3.0mm$. Moreover, it showed no difference in different media such as the water and the blood at the temperature range of $35\sim40^{\circ}C$.

Linear Correlation between Online Capacitance and Offline Biomass Measurement up to High Cell Densities in Escherichia coli Fermentations in a Pilot-Scale Pressurized Bioreactor

  • Knabben, Ingo;Regestein, Lars;Schauf, Julia;Steinbusch, Sven;Buchs, Jochen
    • Journal of Microbiology and Biotechnology
    • /
    • v.21 no.2
    • /
    • pp.204-211
    • /
    • 2011
  • To yield high concentrations of protein expressed by genetically modified Escherichia coli, it is important that the bacterial strains are cultivated to high cell density in industrial bioprocesses. Since the expressed target protein is mostly accumulated inside the E. coli cells, the cellular product formation can be directly correlated to the bacterial biomass concentration. The typical way to determine this concentration is to sample offline. Such manual sampling, however, wastes time and is not efficient for acquiring direct feedback to control a fedbatch fermentation. An E. coli K12-derived strain was cultivated to high cell density in a pressurized stirred bioreactor on a pilot scale, by detecting biomass concentration online using a capacitance probe. This E. coli strain was grown in pure minimal medium using two carbon sources (glucose and glycerol). By applying exponential feeding profiles corresponding to a constant specific growth rate, the E. coli culture grew under carbon-limited conditions to minimize overflow metabolites. A high linearity was found between capacitance and biomass concentration, whereby up to 85 g/L dry cell weight was measured. To validate the viability of the culture, the oxygen transfer rate (OTR) was determined online, yielding maximum values of 0.69 mol/l/h and 0.98mol/l/h by using glucose and glycerol as carbon sources, respectively. Consequently, online monitoring of biomass using a capacitance probe provides direct and fast information about the viable E. coli biomass generated under aerobic fermentation conditions at elevated headspace pressures.

A Study on the Standards for Xe Analysis by Wavelength Dispersive X-ray Spectrometer (WDS) of Electron Probe Micro Analysis (EPMA) (파장분산형 엑스선 분광기에 의한 전자탐침미세분석시 Xe 표준물질에 관한 연구)

  • Park, Soon Dal;Ha, Young Kyeung;Kim, Jong Goo;Jee, Kwang Young;Kim, Won Ho
    • Analytical Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.565-572
    • /
    • 2000
  • In this paper it was described on the standards for Xe analysis by Wavelength Dispersive X-ray Spectrometer (WDS) of Electron Probe Micro Analyser. According to the experimental results, CsI and $BaCO_3$ are appropriate compounds as standard specimen for Cs, I and Ba which has not suitable pure metal standards. In the beam current of 10-30 nA range, the Cs x-ray intensity measured from CsBr and CsI was proportional to the beam current. It was found that the linear regression factor R, showing the linearity between the atomic number and x-ray intensity between In and Nd elements, was higher than 0.99 at 25 kV and PET crystal. The caJlculated x-ray intensity of Xe standard from this linear regression equation was 1.095 times higher than that ofTe at 25 kV.

  • PDF

Simple and Sensitive Electrochemical Sandwich-type Immunosensing of Human Chorionic Gonadotropin based on b-cyclodextrin Functionalized Graphene

  • Linfen Xu;Ling liu;Xiaoyan Zhao;Jinyu Lin;Shaohan Xu;Jinlian He;Debin Jiang;Yong Xia
    • Journal of Electrochemical Science and Technology
    • /
    • v.14 no.1
    • /
    • pp.51-58
    • /
    • 2023
  • The effective detection of human chorionic gonadotropin (HCG) is considerably important for the clinical diagnosis of both of early pregnancy and nonpregnancy-related diseases. In this work, a simple and sensitive electrochemical sandwich-type immunosensing platform was designed by synthesizing b-cyclodextrin (CD) functionalized graphene (CD/GN) hybrid as simultaneously sensing platform and signal transducer coupled with rhodamine b (RhB) as probe. In brief, GN offers large surface area and high conductivity, while CD exhibits superior host-guest recognition capability, thus the primary antibody (Ab1) of HCG can be bound into the cavities of CD/GN to form stable Ab1/CD/GN inclusion complex; meanwhile, the secondary antibody (Ab2) and RhB can also enter into the cavities, producing RhB/Ab2/CD/GN complex. Then, by using Ab1/CD/GN as sensing platform and RhB/Ab2/CD/GN as signal transducer (in which RhB was signal probe), a simple sandwich-type immunosensor was constructed. Under the optimum parameters, the designed immunosensor exhibited a considerable low analytical detection of 1.0 pg mL-1 and a wide linearity of 0.002 to 10.0 ng mL-1 for HCG, revealing the developed sandwich-type electrochemical immunosensing platform offered potential real applications for the determination of HCG.