• Title/Summary/Keyword: Print-Scan

Search Result 16, Processing Time 0.02 seconds

Synthesis of Hydroxypropyl Chitin and Its Liquid Crystalline Character (히드록시프로필 키틴의 합성과 액정형성)

  • Kim, Seon Jeong;Lee, Young Moo
    • Applied Chemistry for Engineering
    • /
    • v.3 no.3
    • /
    • pp.516-521
    • /
    • 1992
  • Hydroxypropyl chitin (HPCH) was prepared by reacting chitin with propylene oxide. HPCH showed the improved solubility in several organic solvents compared with chitin. It showed the remarkable solubility in formic acid. Form the results of polarized microscopic observatoin of HPCH solution in formic acid, finger-print pattern was observed in concentrations over 30 wt% solution. Since no typical thermogram was observed in DSC scan, the HPCH showed a lyotropic cholestric liquid crystallinity.

  • PDF

A Study of Orthognathic Surgical Guides with Two-stage Split Path (2단 절개 형태를 가지는 악교정 수술 장치 연구)

  • Min Uk, Kim;Chung Hwan, Park;Ji Hyoung, Rho;Eui Sung, Jung;Young Sang, Park;Dong Guk, Kim;Yohan, Seo;Young Jea, Woo;Jong Min, Lee
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.6
    • /
    • pp.382-389
    • /
    • 2022
  • In this study, the accuracy of the orthognathic surgical guides with single-stage split path was upgraded to realize orthognathic surgical guides with two-stage split path and simulated surgery was performed to verify its accuracy. As a result, the average error distance between the simulation model and the scan model was + 0.289 / - 0.468 mm (standard deviation 0.128), which was confirmed to be within ± 0.5 mm, which is a clinically acceptable level. Also, there was no significant difference compared with the average value of + 0.313 / - 0.456 mm (average standard deviation 0.106) of the conventional single-stage split path type device. It is judged that the use of this device can contribute to the reduction of surgical time and increase in accuracy since a separate finishing operation for bone preparation is unnecessary.

The Effects of Doctoring Process in Gravure Off-set Printing on Patterning of Electrodes with Ag Ink (은 잉크를 이용한 그라비아 오프셋의 전극인쇄에서 닥터링 공정의 영향)

  • Choi, Ki Seong;Park, Jin Seok;Song, Chung-Kun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.6
    • /
    • pp.462-467
    • /
    • 2013
  • In this paper, we analyzed the effects of doctoring process on the patterns of Ag ink in gravure off-set printing. The parameters of doctoring process were the angle and the pressure, which was represented by the depth of blade movement to the gravure roll, of doctor blade to the surface of gravure roll, and the angle of patterns engraved on the gravure roll to the doctor blade moving direction. The proper parameters were extracted for the fine patterns and they were 15 mm for the pressure, $60^{\circ}$ for the blade angle. And the angle of patterns with respect to the blade movement should be less than $40^{\circ}$ for the best results. The gravure off-set printing with the above parameters was carried out to print gate electrodes and scan bus lines of OTFT-backplane for e-paper. The line width of $50{\mu}m$ was successfully obtained. The thickness of electrodes was $2.5{\mu}m$ and the surface roughness was $0.65{\mu}m$ and the sheet resistance was $15.8{\Omega}/{\Box}$.

Inscribed Transceiver Optical System Design for Laser Radar with Zoom-type Expander (줌렌즈 광속확대기를 적용한 레이저 레이더용 송수광 내접형 광학계 설계)

  • Koh, Hae Seog;Ok, Chang Min;Hong, Jin Sug;Lee, Chang Jae;Park, Chan Geun;Kim, Hyun Kyu
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.1
    • /
    • pp.23-28
    • /
    • 2013
  • In this paper, an optical system was designed for 3D imaging laser radar with optical scanner. In order to make it easy to scan, the system was designed to inscribe the transmitting objective lens in the receiving lens. In transmitting optics, the beam expander was designed to have a zoom mechanism so that the transmitted beam size would be 4.8 m or 6.8 m at 1 km distance, when the laser source's numerical aperture value is between 0.13 and 0.22. The beam diameter at the target 1 km away was confirmed by design program. The receiving optics for the returning beam from the target was designed for the $16{\times}16$ array detector with $100{\mu}m$ pixel width. The spot diameter in every pixel was designed and verified to be less than $55{\mu}m$. The receiving optics' obscuration ratio by transmitting optics was 11%.

Normal Human Pleural Surface Area Calculated by Computed Tomography Image Data

  • Kim, Doo-Sang;Roh, Hyung-Woon
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.4 no.1
    • /
    • pp.27-30
    • /
    • 2006
  • Background; Pleural micro-metastasis of lung cancer is detected by touch print cytology or pleural lavage cytology, but its prognostic impact has not elucidated yet. We hypothesize that recurrence may depend on the amount of tumor cells disseminated in pleural cavity, if the invasiveness of all cancer is the same. To predict the amount of tumor cells disseminated in pleural cavity, we need pleural surface area, distributed pattern of cells and concentration of cells per unit area. Human pleural surface area has not reported yet. In this report, we calculate the normal human pleural surface area using CT image data processing. Methods; Twenty persons were checked CT scan, and we obtained the data from each image. In order to calculate the pleural surface, the outline of lung was firstly extruded from CT image data using home-made Digitizer program. And the distance between CT images was calculated from the extruded outline. Finally a normal human pleural surface was calculated from function between the distance of consecutive CT images and the calculated length. Results; Their mean age is $65{\pm}12$ years old (range $26{\sim}77$), body weight is $62{\pm}9\;kg\;(48{\sim}80)$, and height is $167{\pm}6\;cm\;(156{\sim}176)$. The number of images used is $36{\pm}7\;(24{\sim}51)$. Pleural surface area is $211,888{\pm}35,756\;mm^2\;(143,880{\sim}279,576)$. Right-side pleural surface area is $107,932\;mm^2$ and Lt is $103,955\;mm^2$. Costal, mediastinal and diaphragmatic surfaces of right-side pleura are $77,483\;mm^2,\;39,057\;mm^2,\;and\;8,608\;mm^2$ respectively, and left-side are $72,497\;mm^2,\;35,578\;mm^2,\;and\;4,120\;mm^2$ respectively. Conclusion; Normal human pleural surface area is calculated using CT image data at first and the result is about $0.212\;m^2$.

  • PDF

Design and Implementation of Weather Fax System for Coast Sailing (연안 항해용 기상 팩스 시스템의 설계 및 구현)

  • 윤희철;이태오;임채홍
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.8
    • /
    • pp.1251-1258
    • /
    • 2002
  • The weather FAX machine is the one of necessary of safety navigation for ship. which is the machine which make the weather image by the receiving radio signal which is modulated using FSK method and transmitted on air by coast station. after Coast station scan the weather image and broadcast the image with black dot to 1500Hz and white dot to 2300Hz using FSK modulation. This paper implement weather fax machine using only general IBM-PC by software. By using IBM-PC we can make some good functions like print, edit, save etc. The modulated signal from SSB go into RS232C port via photo coupler not to give damage to PC. by using Timer Interrupt and RS232C serial interrupt, we can measure signal frequency and remake weather image. This paper use only IBM-PC with general SSB receiver which is widely spread on the ship. so this is very economic and possible to implement mutifunctions.