DOI QR코드

DOI QR Code

The Effects of Doctoring Process in Gravure Off-set Printing on Patterning of Electrodes with Ag Ink

은 잉크를 이용한 그라비아 오프셋의 전극인쇄에서 닥터링 공정의 영향

  • Choi, Ki Seong (Department of Electronics Engineering, Dong-A University) ;
  • Park, Jin Seok (Department of Electronics Engineering, Dong-A University) ;
  • Song, Chung-Kun (Department of Electronics Engineering, Dong-A University)
  • Received : 2013.05.08
  • Accepted : 2013.05.24
  • Published : 2013.06.01

Abstract

In this paper, we analyzed the effects of doctoring process on the patterns of Ag ink in gravure off-set printing. The parameters of doctoring process were the angle and the pressure, which was represented by the depth of blade movement to the gravure roll, of doctor blade to the surface of gravure roll, and the angle of patterns engraved on the gravure roll to the doctor blade moving direction. The proper parameters were extracted for the fine patterns and they were 15 mm for the pressure, $60^{\circ}$ for the blade angle. And the angle of patterns with respect to the blade movement should be less than $40^{\circ}$ for the best results. The gravure off-set printing with the above parameters was carried out to print gate electrodes and scan bus lines of OTFT-backplane for e-paper. The line width of $50{\mu}m$ was successfully obtained. The thickness of electrodes was $2.5{\mu}m$ and the surface roughness was $0.65{\mu}m$ and the sheet resistance was $15.8{\Omega}/{\Box}$.

Keywords

References

  1. A. Knobloch, Proc. of the First International IEEE Conference on Polymers and Adhesives in Microelectronics and Photonics (Polytronic 2011, Potsdam, Germany, 2001) p. 84.
  2. B. Choi, C. Kim, and D. Kim, Proc. Inst. Mech. Eng., Part C: J. Mech. Eng. Sci., 224, 149 (2010).
  3. D. Shin, Y. Lee, and C. Kim, Thin Solid Films, 517, 6112 (2009). https://doi.org/10.1016/j.tsf.2009.05.019
  4. C. Kim and Y. Lee, Int. J. Precis. Eng. Manuf., 12, 161 (2011). https://doi.org/10.1007/s12541-011-0022-y
  5. J. Siden, M. K. Fein, A. Koptyug, and H. Nilsson, IET Proc. Microwaves, Antennas Propag., 1, 401 (2007).
  6. T. Lee, Y. Choi, S. Nam, C. You, D. Na, H. Choi, D. Shin, K. Kim, and K. Jung, Thin Solid Films, 516, 7875 (2008). https://doi.org/10.1016/j.tsf.2008.05.044
  7. T. Lee, J. Noh, C. Kim, J. Jo, and D. Kim, Thin Solid Films, 518, 3355 (2010). https://doi.org/10.1016/j.tsf.2009.10.017
  8. P. Pesavento, K. Puntambekar, C. Frisbiea, J. McKeen, and P. Ruden, J. Appl. Phys., 99, 4504 (2006).
  9. Y. Mo, Trans. KIEE., 38, 49 (2011).
  10. Y. Noh, H. Han, K. Bae, A. Cho, and H. Lee, The Korean Information Display Society, 11, 3 (2011).
  11. H. Klauk, Chem. Soc. Rev., 39, 2643 (2010). https://doi.org/10.1039/b909902f
  12. M. Pudas, J. Eur. Ceram. Soc., 24, 2943 (2004). https://doi.org/10.1016/j.jeurceramsoc.2003.11.011
  13. C. Kim, H. Jeong, E. Heo, B. Lee, B. Yu, B. Lee, H. Kim, and T. Kweon, Anti-Electromigration of Lead-Free Ag/Frit Modified Address Electrodes in PDPs (SID'08 Technical Digest, Los Angeles, USA, 2008) p. 190-93.
  14. I. Kim, S. Kwak, K. Kim, T. Lee, J. Jo, J. Kim, and H. Lee, Microelectron. Eng., 98, 587 (2012). https://doi.org/10.1016/j.mee.2012.06.012

Cited by

  1. Control and measurement of doctoring angle at deformed state in doctoring apparatus for printed electronics vol.18, pp.5, 2017, https://doi.org/10.1007/s12541-017-0076-6
  2. Development of doctoring apparatus capable of measurement and control of doctoring angle and force in printing equipment for printed electronics vol.29, pp.9, 2018, https://doi.org/10.1088/1361-6501/aad0fd