• Title/Summary/Keyword: Primary-Secondary pump system

Search Result 18, Processing Time 0.022 seconds

Energy Consumption Evaluation in Pumping System with Different Building Characteristics (건물 특성에 따른 냉수 순환 펌핑 시스템 별 에너지 소모량 분석)

  • Shin, Dong-Shin;Park, Sung-Bin;Jun, Tae-Ik;Ma, Kang-Il;Kim, Tae-Hong;Lee, Sung-Goo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.6
    • /
    • pp.242-247
    • /
    • 2016
  • This study analyzed the energy consumption of a building pump system that was originally equipped with a primary-secondary zone pump system. Using the HYSYS program the energy consumption of the primary pump system was compared with the primary-secondary zone pump system. The primary-secondary zone pump system consumes less energy than the originally designed primary pump system. When the distance between the machine room and each building is assumed to be equal, the primary pump system can be more efficient than the primary-secondary zone pump system with decreasing the distance. When the distance is 120 m, the primary system consumes less total annual energy than the primary-secondary zone pump system and saves 2,773 kWh. The suggested energy evaluation program can be useful if the designer seeks a more efficient pump system.

Flow Analyses Inside Jet Pumps Used for Oil Wells

  • Samad, Abdus;Nizamuddin, Mohammad
    • International Journal of Fluid Machinery and Systems
    • /
    • v.6 no.1
    • /
    • pp.1-10
    • /
    • 2013
  • Jet pump is one type of artificial lifts and is used when depth and deviation of producing wells increases and pressure depletion occurs. In the present study, numerical analysis has been carried out to analyze the flow behavior and find the performance of the jet pump. Reynolds-averaged Navier Stokes equations were solved and k-${\varepsilon}$ turbulence model was used for simulations. Water and light oil as primary fluids were used to pump water, light oil and heavy oil. The ratios of area and length to diameter of the mixing tube were considered as design parameters. The pump efficiency was considered to maximize for the downhole conditions. It was found that the increase in viscosity and density of the secondary fluid reduced efficiency of the system. Water as primary fluid produced better efficiency than the light oil. It was also found that the longer throat length increased efficiency upto 40% if light oil was used as primary fluid and secondary fluid viscosity was 350 cSt.

Energy Efficient Design of a Jet Pump by Ensemble of Surrogates and Evolutionary Approach

  • Husain, Afzal;Sonawat, Arihant;Mohan, Sarath;Samad, Abdus
    • International Journal of Fluid Machinery and Systems
    • /
    • v.9 no.3
    • /
    • pp.265-276
    • /
    • 2016
  • Energy systems working coherently in different conditions may not have a specific design which can provide optimal performance. A system working for a longer period at lower efficiency implies higher energy consumption. In this effort, a methodology demonstrated by a jet pump design and optimization via numerical modeling for fluid dynamics and implementation of an evolutionary algorithm for the optimization shows a reduction in computational costs. The jet pump inherently has a low efficiency because of improper mixing of primary and secondary fluids, and multiple momentum and energy transfer phenomena associated with it. The high fidelity solutions were obtained through a validated numerical model to construct an approximate function through surrogate analysis. Pareto-optimal solutions for two objective functions, i.e., secondary fluid pressure head and primary fluid pressure-drop, were generated through a multi-objective genetic algorithm. For the jet pump geometry, a design space of several design variables was discretized using the Latin hypercube sampling method for the optimization. The performance analysis of the surrogate models shows that the combined surrogates perform better than a single surrogate and the optimized jet pump shows a higher performance. The approach can be implemented in other energy systems to find a better design.

The Effect of Multi Nozzles on the Characteristics of Annular Jet Pump (다중노즐을 이용한 환형 제트 펌프의 성능에 관한 연구)

  • Kim, M.K.;Kwon, O.B.
    • Journal of Power System Engineering
    • /
    • v.3 no.1
    • /
    • pp.23-28
    • /
    • 1999
  • Experimental and theoretical researches about jet pump have been carried out by many researchers. Jet pump can be used for the transportation of solid materials, farm produce, and fishes. It is the purpose of this paper to seek optimal multi nozzle shape of the annular jet pump. Experiments were done for several jet nozzle areas, jet nozzle arrays and jet nozzle lengths. Water was used for both the primary fluid and secondary fluid. The efficiency curves for the annular jet pump having multi nozzles are presented in this paper.

  • PDF

The Effect of Mixing Chamber on the Characteristics of Annular Jet Pump (혼합실 형상에 따른 환형 제트펌프의 특성)

  • Kwon, O.B.;Choi, H.;Oh, B.H.
    • Journal of Power System Engineering
    • /
    • v.1 no.1
    • /
    • pp.35-41
    • /
    • 1997
  • Annular jet pump can be used for the transportation of solid materials and fish. The effect of mixing chamber on the characteristics of annular jet pump is sought in this paper. Experiments were done for several reducing angles of mixing chamber, and for several throat area. Water was used for both the primary fluid and secondary fluid. A vortex was observed for the straight mixing chamber, but it was not observed for the mixing chamber whose reducing angle is $18^{\circ}$ or higher. The efficiency curves for the annular jet pump are presented in this paper, showing the annular jet pump which has 240 reducing angle and $0.611{\sim}0.73$ value of At/As. is most effective among the tested several annular jet pumps.

  • PDF

Design of a Bidirectional AC-DC Converter using Charge Pump Power Factor Correction Circuit (전하펌프 역률개선 회로를 적용한 양방향성 AC-DC Converter 설계)

  • Ko, Seok-Cheol;Lim, Sung-Hun;Han, Byoung-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.227-230
    • /
    • 2001
  • This paper deals with a bidirectional ac-dc converter used in ups system application. We propose a Voltage-Source-Charge-Pump-Power-Factor-Correction(VS-CPPFC) ac-dc converters. First of all, we propose a charge pump power-factor-correction converter. Secondly, we derive and analyse a unity power factor condition. The proposed topology is based on a half-bridge for the primary and a current-fed push pull for the secondary side of a high frequency isolation transformer. The advantage of bidirectional flow of power achieved by using the same power components is that the circuit is simple and efficient. And the galvanically isolated topology is specially attractive in battery charge/discharge circuits in ups system. We design equivalent model for the steady-state circuit and analyse operation waveforms for each mode. We show that the proposed model can be applied to ups system by simulation processes.

  • PDF

A CFD Study of the Supersonic Ejector-Pump Flows (초음속 이젝터 펌프 유동에 관한 수치해석)

  • 이영기;김희동;서태원
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.3 no.4
    • /
    • pp.58-66
    • /
    • 1999
  • The flow characteristics of supersonic ejectors is often subject to compressibility, unsteadiness and shock wave systems. The numerical works carried out thus far have been of one-dimensional analyses or some Computational Fluid Dynamics(CFD) which has been applied to only a very simplified configuration. For the design of effective ejector-pump systems the effects of secondary mass flow on the supersonic ejector flow should be fully understood. In the present work the supersonic ejector-pump flows with a secondary mass flow were simulated using CFD. A fully implicit finite volume scheme was applied to axisymmetric compressible Navier-Stokes equations. The standard two-equation turbulence model was employed to predict turbulent stresses. The results obtained showed that the flow characteristics of constant area mixing tube types were nearly independent of the secondary flow rate, but the flow fields of ejector system with the second-throat were strongly dependent on the secondary flow rate due to the effect of the back pressure near the primary nozzle exit.

  • PDF

Computational Study of the Axisymmetric, Supersonic Ejector-Diffuser Systems

  • Kim, Heuy-Dong;Lee, Young-Ki;Seo, Tae-Won;Raghunathan, Srinivasan
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.520-524
    • /
    • 2000
  • A ejector system is one of the fluid machinery, which has been mainly used as an exhaust pump or a vacuum pump. The ejector system has often been pointed out to have only a limited efficiency because it is driven by pure shear action and the mixing action between primary and secondary streams. In the present work, numerical simulations were conducted to investigate the effects of the geometry and the mass flow ratio of supersonic ejector-diffuser systems on their mixing performance. A fully implicit finite volume scheme was applied to solve the axisymmetric Navier-Stokes equations, and the standard ${\kappa}-{\varepsilon}$ turbulence model was used to close the governing equations. The flow fields of the supersonic ejector-diffuser systems were investigated by changing the ejector throat area ratio and the mass flow ratio. The existence of the second throat strongly affected the shock wave structure inside the mixing tube as well as the spreading of the under-expanded jet discharging from the primary nozzle, and served to enhance the mixing performance.

  • PDF

Evaluation of actual Energy consumption & Simulation of Gas Engine VRF System and Comparison with Electric VRF System (가스 엔진 VRF시스템의 에너지 실사용량 & 시뮬레이션 평가와 전기 구동 VRF 시스템과의 성능비교에 관한 연구)

  • Choi, Sul-Geon;Jeon, Jong-Ug;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • v.17 no.4
    • /
    • pp.67-74
    • /
    • 2017
  • Purpose: As the recent climate environment changes so rapidly, environmental problems such as hot weather and fine dust have occurred, and interest in environmental policies and technology development is increasing in countries around the world. Similarly in the Architecture, researches to reduce greenhouse gas emissions and to reduce energy application are actively conducted. Looking at previous studies, it is analyzed that the electric VRF is more energy efficient than the gas engine VRF. However, energy costs have changed due to recent price hikes and discounts on gas charges due to high electricity consumption in summer. Method: In this study, the actual building of Gas Engine VRF system was modeled using SketchUp program, and EnergyPlus was used to simulate actual building. Also, Electric VRF system was simulated, and compared with Gas Engine VRF system. Result: The total secondary energy requirement of Electric VRF system was 19.6% less than that of the Gas Engine VRF system, But when analyzing with primary energy requirement, EHP used 15.8% more energy. CO2 emissions were also estimated to be 16.9% more EHP. Energy costs were 14.8% more in Electric VRF systems, because their electricity charges are 0.6 to 160% more expensive than gas charges.

Process Design and Analysis of BOG Re-liquefaction System with Pre-liquefaction of NGL (NGL 분리식 BOG 재액화 공정 고안 및 해석)

  • Yun, Sang-Kook
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.3
    • /
    • pp.32-37
    • /
    • 2015
  • The boil-off-gases(BOG) in cryogenic LNG storage tanks are generating continuously due to the heat leakage and need to be re-liquefied by the effective way. As the present method to reliquefy BOG is using LNG cold energy to be supplied after low pressure primary pump, the demand of LNG flow rate should be over 10 times of BOG produced rate to reliquefy it. This research invented new effective re-liquefaction system having only 3~4 times of LNG flow rate against unit BOG, that the pre-liquefaction process of NGL and the use of high pressure LNG cold energy after secondary pump. By the analysis, it could be high efficient reliquefying system for all amount of BOG treatment even during the summer time, and improvement of operation safety and efficiency of LNG terminal.