• 제목/요약/키워드: Primary air

검색결과 880건 처리시간 0.033초

화학레이저 구동용 이젝터 시스템 개발 (I) - 화학레이저 구동용 초음속 이젝터 설계 변수 연구 - (Development of Ejector System for Chemical Lasers Operating (I) - Design Parameter Study of Supersonic Ejector for Chemical Lasers Operating -)

  • 김세훈;권세진
    • 대한기계학회논문집B
    • /
    • 제27권12호
    • /
    • pp.1673-1680
    • /
    • 2003
  • It is essential to operate chemical lasers with supersonic ejector system as the laser output power goes up. In this research, ejector design parameter study was carried out for optimal ejector design through understanding the ejector characteristics and design requirements for chemical lasers operating. Designed ejector was 3D annular type with 2$^{nd}$ -throat geometry and pressurized air was used for primary flow. Ejector design was carried out with two steps, quasi-1D gas dynamics was used for first design and commercial code was used to verify the first design. In this study, to get the effect of ejector geometry on its performance, three cases of primary nozzle area ratio and 2$^{nd}$ -throat cross sectional area and two cases of 2$^{nd}$ -throat L/D ratio experiments were carried out. Primary and secondary pressures were measured to get the mass flow rate ratio, minimum secondary pressure, ejector starting pressure and unstarting pressure at every case. In the result, better performance than design level was shown and optimal ejector design method for chemical lasers was obtained.

Assessment of Personal Exposure to Nitrogen Dioxide in Primary Schoolchildren

  • Cho Yong-Sung;Lee Jong-Tae;Kim Yoon-Shin
    • 한국환경보건학회지
    • /
    • 제32권3호
    • /
    • pp.207-214
    • /
    • 2006
  • This study was designed to assess the level of nitrogen dioxide from several microenvironments including inside the home, outdoors near the home, inside the school, outdoors near the school, and on the road for 42 primary schoolchildren during the month of December 2002 in Seoul, Korea. The average personal, indoor, outdoor $NO_2$ levels, and indoor/outdoor ratio were 45.08 ppb, 27.89 ppb, 30.96 ppb, and 0.89, respectively. The indoor $NO_2$ concentrations were significantly associated with the presence of a smoker with a gas stove. The estimated personal $NO_2$ exposure using time-weighted average equation of $34.64{\pm}5.29$ ppb was significantly lower than the measured personal exposure of $45.08{\pm}5.50$ ppb. Our results indicate that indoor $NO_2$ levels were associated with the presence of a smoker and a gas stove. Moreover, personal $NO_2$ exposure with a gas stove in the house was significantly higher than those without a gas stove.

최대출력을 얻기 위한 유도급전장치의 형태에 따른 전자장 해석 (Analysis of electromagnetic fields in relation to the forms of IPT systems to get maximum output)

  • 최석진;오윤상;이상진;이병송;박찬배;이형우
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.481-487
    • /
    • 2010
  • The equivalent circuits intended to analyze the characteristics of IPT systems can be shown in structures similar to those of existing transformers. IPT systems are composed of combinations of the primary and secondary coils based on magnetic coupling, and the performances are determined by the lengths or the degrees of magnetic coupling of current collecting conductors(secondary) and feeding rails (primary) and system performances become the maximum when they are coupled under the optimum condition. To maximize the output currents of the secondary side, the shapes of iron cores and the structures of coils etc should be considered. To this end, three types of IPT system simulation models were selected and they were analyzed using an electromagnetic field analyzing program. To compare the types with each other, the sizes of the IPT systems and the primary side voltages etc were made to be the same. The electromagnetic fields were analyzed while changing the thicknesses of the cores and the lengths of the air gap etc and the results were analyzed in order to derive the optimum specifications.

  • PDF

지역난방 시스템에서 제어방법에 따른 공급열량의 해석적 연구 (The Analysis Study on Supplying Heat by Various Control Methods in District Heating System)

  • 김성수;정상훈;문연진;조성환;유재성
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1008-1013
    • /
    • 2009
  • The theoretical simulation to predict the variation of supplying heat according to control methods of DHS(District Heating System) have been done by TRNSYS(A Transient System Simulation Program) 16. The physical system for DHS consists of primary and secondary supplying heating loop which is divided by based on heat exchanger for heating demand of building. The simulation results showed that control of secondary supplying heat had influenced more than primary supplying heat control to total energy consumption of DHS. And the outside temperature reset control of primary supplying heating loop could be reduced until about 4% overheating of each zone.

  • PDF

촉매 변환기 내부 유동의 실험적 해석 (Experimental Analysis on the Catalytic Converter Internal Flow)

  • 유성출
    • 한국가시화정보학회지
    • /
    • 제10권2호
    • /
    • pp.20-24
    • /
    • 2012
  • Increasing the active catalyst surface area is important in improving a converter's efficiency. In addition, uniform flow is advantageous in that it produces more efficient catalytic conversion. This results in the ability to use a smaller catalytic converter with uniform flow as opposed to a larger converter requirement for non-uniform flow. Therefore, it is important to characterize the internal flow of the catalytic converter. To characterize the system's flow patterns, velocity measurements were taken at the mid and exit planes of a ceramic honeycomb catalytic converter at flow rates of 37.8 l/s and 94.4 l/s. Measurements were conducted using LDV. The profiles were measured along both the major and minor axis of the planes. Primary flow direction velocities measured along the minor axis, at both flow rates, varied greatly at the mid plane and somewhat at the exit plane. The areas of greatest air flow were seen near the edges of the walls and on the side of the converter opposite the flow's entrance region. It also appears that the high velocities opposite the intake are due to the design of the entrance region. The entrance region is possibly too small to properly redirect the vertically entering fluid into an evenly distributed flow in the primary flow direction.

Energy spectrum of particles arriving at the ground and S(800) determination by Monte Carlo simulation for Telescope Array

  • Kim, Ji-Hee;Roh, Soon-Young;Ryu, Dong-Su;Kang, Hye-Sung;Kasahara, Katuaki;Kido, Eiji;Taketa, Akimichi
    • 천문학회보
    • /
    • 제35권2호
    • /
    • pp.58.1-58.1
    • /
    • 2010
  • Telescope Array (TA) experiment in Utah, USA, observes ultrahigh-energy cosmic rays (UHECRs); UHECRs refer cosmic rays with energy above $10^{18}eV$. Using COSMOS and CORSIKA, we have produced a library of over 1000 thinned extensive air shower (EAS) simulations with the primary energies ranging from $10^{18.5}eV$ to $10^{20.25}eV$ and the zenith angle of primary cosmic ray particle from $0^{\circ}$ to $45^{\circ}$. Here, we present the energy spectrum of particles arriving at the ground. We have also calculated the detector response evaluated using GEANT4 simulations. Here, we discuss S(800), i.e. the signal at a distance of 800 m from the shower core, as the primary energy estimator.

  • PDF

A Forecast Model for the First Occurrence of Phytophthora Blight on Chili Pepper after Overwintering

  • Do, Ki-Seok;Kang, Wee-Soo;Park, Eun-Woo
    • The Plant Pathology Journal
    • /
    • 제28권2호
    • /
    • pp.172-184
    • /
    • 2012
  • An infection risk model for Phytophthora blight on chili pepper was developed to estimate the first date of disease occurrence in the field. The model consisted of three parts including estimation of zoosporangium formation, soil water content, and amount of active inoculum in soil. Daily weather data on air temperature, relative humidity and rainfall, and the soil texture data of local areas were used to estimate infection risk level that was quantified as the accumulated amount of active inoculum during the prior three days. Based on the analysis on 190 sets of weather and disease data, it was found that the threshold infection risk of 224 could be an appropriate criterion for determining the primary infection date. The 95% confidence interval for the difference between the estimated date of primary infection and the observed date of first disease occurrence was $8{\pm}3$ days. In the model validation tests, the observed dates of first disease occurrence were within the 95% confidence intervals of the estimated dates in the five out of six cases. The sensitivity analyses suggested that the model was more responsive to temperature and soil texture than relative humidity, rainfall, and transplanting date. The infection risk model could be implemented in practice to control Phytophthora blight in chili pepper fields.

Synthesis and Characterization of TiO2, Cu2O and Al2O3 Aerosol Nanoparticles Produced by the Multi-Spark Discharge Generator

  • Efimov, Alexey;Lizunova, Anna;Sukharev, Valentin;Ivanov, Victor
    • 한국재료학회지
    • /
    • 제26권3호
    • /
    • pp.123-129
    • /
    • 2016
  • The morphology, crystal structure and size of aerosol nanoparticles generated by erosion of electrodes made of different materials (titanium, copper and aluminum) in a multi-spark discharge generator were investigated. The aerosol nanoparticle synthesis was carried out in air atmosphere at a capacitor stored energy of 6 J, a repetition rate of discharge of 0.5 Hz and a gas flow velocity of 5.4 m/s. The aerosol nanoparticles were generated in the form of oxides and had various morphologies: agglomerates of primary particles of $TiO_2$ and $Al_2O_3$ or aggregates of primary particles of $Cu_2O$. The average size of the primary nanoparticles ranged between 6.3 and 7.4 nm for the three substances studied. The average size of the agglomerates and aggregates varied in a wide interval from 24.6 nm for $Cu_2O$ to 46.1 nm for $Al_2O_3$.

습식분쇄에 의한 입자크기 변화에 따른 분쇄입자의 종횡비 거동 (Aspect Ratio Behavior of Grinding Particles with Variation of Particle Size by Wet Grinding)

  • 최진삼
    • 한국재료학회지
    • /
    • 제30권5호
    • /
    • pp.223-230
    • /
    • 2020
  • As a case study on aspect ratio behavior, Kaolin, zeolite, TiO2, pozzolan and diatomaceous earth minerals are investigated using wet milling with 0.3 mm media. The grinding process using small media of 0.3 pai is suitable for current work processing applications. Primary particles with average particle size distribution D50, ~6 ㎛ are shifted to submicron size, D50 ~0.6 ㎛ after grinding. Grinding of particles is characterized by various size parameters such as sphericity as geometric shape, equivalent diameter, and average particle size distribution. Herein, we systematically provide an overview of factors affecting the primary particle size reduction. Energy consumption for grinding is determined using classical grinding laws, including Rittinger's and Kick's laws. Submicron size is obtained at maximum frictional shear stress. Alterations in properties of wettability, heat resistance, thermal conductivity, and adhesion increase with increasing particle surface area. In the comparison of the aspect ratio of the submicron powder, the air heat conductivity and the total heat release amount increase 68 % and 2 times, respectively.

아음속/초음속 증기 이젝터에 관한 실험적 연구 (An Experimental Study of the Subsonic/Supersonic Steam Ejectors)

  • 최보규;김희동;이준희;김덕줄
    • 한국추진공학회지
    • /
    • 제4권4호
    • /
    • pp.1-8
    • /
    • 2000
  • 본 연구에서는 아음속/초음속 이젝터 시스템의 효과적인 설계를 목적으로, 증기 보일러로부터 발생하는 파열증기를 1차 구동유체로 하는 축대칭 아음속/초음속 이젝터 유동을 실험하였다. 과열증기는 여러형태의 아음속/초음속 노즐에 의하여 이젝터 혼합부로 방출되도록 설계되었으며, 2차정체실 내부에 있는 대기 공기는 증기제트에 의하여 혼합부로 유입된다. 실험에서는 2차정체실의 진공성능을 조사하기 위하여 넓은 범위의 이젝터 자동압력비에 대하여 적용하였다. 본 연구의 결과로부터 이젝터목에서 혼한유동의 정압은 1차 노즐의 형태에 관계없이 이젝터 작동압력비의 함수만에 의하여 결정된다는 것을 알았다.

  • PDF