• Title/Summary/Keyword: Primary Air

Search Result 880, Processing Time 0.042 seconds

Numerical Study on Supersonic Flow in the Second Throat Ejector-Diffuser System (이차목 이젝터/디퓨저 시스템을 통하는 초음속 유동에 관한 수치해석적 연구)

  • 김희동;이영기;서태원;김윤곤
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1998.04a
    • /
    • pp.14-14
    • /
    • 1998
  • The ejector is a device which employs a high-velocity primary motive fluid to entrain and accelerate a slower moving secondary suction fluid. The resulting kinetic energy of the mixture is subsequently used for self-compression to a higher pressure, thus performing the function of a compressor. The outstanding advantages of the ejectors are simplicity and reliability. However the industrial use of ejectors has been confined mainly to very particular cases of operation. The experimental results obtained so far were insufficient to be made use of general cases. Large-sized modern ejectors, mainly driven by high powered air-compressors and designed for very wide ranges of operating conditions, cannot be based on the earlier research results, if we wish to be sure of the final outcome.

  • PDF

Analysis of Life Cycle Cost for Heat Source Equipments in Buildings for Adolescent Trainees (청소년 수련관의 열원설비 대안별 생애주기 비용에 관한 연구)

  • Ahn, Chang-hwan;Pang, Seung-ki;Baik, Yong-gyu
    • KIEAE Journal
    • /
    • v.5 no.3
    • /
    • pp.25-31
    • /
    • 2005
  • Computer simulations were performed for Heating Ventilating and Air-Conditioning (HVAC) systems to figure out more efficient maintenance methods for the building used for adolescent trainees. This study aims at suggesting design alternatives for optimum operation and performing life cycle cost (LCC) for each alternative. First, the capacity of the heat source equipment was determined using annual maximum heating and cooling loads. Annual loads were calculated and applied to the alternative for the purpose of calculating annual energy cost. Second, several types of data were collected to predict energy cost. Finally, the pay back period for each alternative was calculated using total cost estimation during standard duration period. This study indicates that the absorption chiller that does not occupy most part of a mechanical room, and does not need much operation cost was most economical.

Newest Computational Technology for Greenhouse Production Systems - Computational Fluid Dynamics(CFD) Numerical Techniques

  • Lee, In-Bok;Short, Ted H.;Sase, Sadanori
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1999.11a
    • /
    • pp.126-129
    • /
    • 1999
  • Natural ventilation is achieved by air exchanges through multiple openings due to natural pressure variations inside and outside the greenhouse. Wind is the primary driving force making natural ventilation systems very difficult to design properly because of variations in wind velocity and direction. The optimization of these systems for acceptable climate control requires a thorough knowledge of the airflow rates and patterns as related to weather conditions and greenhouse structural details. (omitted)

  • PDF

A Study of On-Off Solenoid Actuator (On-Off 솔레노이드 엑츄에이터의 특성 연구)

  • Jeon, Yong-Sik;Kim, Dong-Soo;Lim, Kee-Joe
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.154-155
    • /
    • 2007
  • Put Recently, development of micro valves that operate by compressed air has received significant attention in the fields of the micro fluid chip for medical applications or production lines of semi-conduct chip for electronic goods. Especially it is required that high-speed responsibility and lower power in optimal design of these micro valves. The primary objective of this study is to compare the optimally designed Solenoid Valve with the actually produced one which can highly improve the efficiency by providing optimal current according to mechanical load.

  • PDF

Implementation of the Primary Air Flow Control in Thermal Power Plant (화력발전소 연소 탄종에 따른 1차 공기량 제어)

  • Kim, B.C.;Byun, S.H.;Baek, J.B.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2160-2162
    • /
    • 2001
  • 화력 발전소의 주 연료로 사용되는 석탄은 1차 공기에 의해 노내로 이송되어 연소되게 된다. 연소에 필요한 1차 공기량은 연소되는 탄의 종류와 급탄기로 보내는 급탄량에 의해 결정되고, 1차 공기량 제어는 연소에 영향을 주며, 역화와 과열 방지를 위해 적절한 제어가 요구된다. 특히 단일 탄종이 아닌 여러 탄종을 연소하는 화력 발전소에서는 탄종에 따라서 그리고 연소되는 탄량에 따라서 미분기로 들어가는 1차 공기량을 변화시켜야만 한다. 본 논문에서는 2종류의 탄을 연소하는 발전소에 대해 연소탄종에 따른 1차 공기량 제어 로직을 구현하고, 구현한 로직에 의한 1차 공기량 제어 결과를 통해 구현한 제어 로직의 효용성을 보인다.

  • PDF

Modeling and Vector Control of HA-PMLSM using film-coil (필름코일을 이용한 HA-PMLSM의 모델링 및 벡터제어)

  • Jang, S.M.;Chang, K.W.;Lee, S.H.;Jeong, S.S.;Jin, S.G.;Yoon, I.K.
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.39-41
    • /
    • 2001
  • This paper deals with a simulation and a position control for linear synchronous motor with Halbach array (HA) permanent magnet mover. We derived decouple the forces (thrust, normal force) by magnetic field modeling of the electromagnetic field analysis. The results of control simulation for HA-PM having air-core primary are calculated using M Simulink.

  • PDF

A Study on the Leakage Inductance in Current Transformers by 3D Integral Methods (3차원 적분법을 이용한 변류기의 누설 인덕턴스에 대한 연구)

  • Lee, Hee-Kab;Park, Yong-Pil;Lee, Sung-Ill
    • Proceedings of the KIEE Conference
    • /
    • 2002.11a
    • /
    • pp.116-118
    • /
    • 2002
  • This paper presents leakage magnetic field and leakage inductance calculations in current transformer by means of 3-D Integral methods. From the distribution diagram of leakage magnetic flux to be analyzed using program called TRACAL 3, it confirms a parallel to the winding axis direction of the leakage flux lines in the air gap between the windings. The leakage inductances $L_{r1}\;and\;L_{r2}$ of the primary and secondary windings were calculated, their values are 4.23 mH and 0.49 mH, respectively. They are also similar to the measured values of the leakage inductances for the experimental verification, 4.06 mH and 0.47 mH.

  • PDF

Clinical Evaluation of Spontaneous Pneumothorax A Review of 165 cases (자연기흉의 임상적 고찰: 165례)

  • 성후식
    • Journal of Chest Surgery
    • /
    • v.18 no.4
    • /
    • pp.582-588
    • /
    • 1985
  • We have observed 165 cases of spontaneous pneumothorax from Aug. 1978 to May. 1985 at the department of Thoracic and Cardiovascular Surgery, School of Medicine, Keimyung University. The ratio of male to female cases were 8.2:1 in male predominance, and the incidence was highest in the adolescence between 21 to 30 year of age. There were 85 patients of primary spontaneous pneumothorax and 80 patients of secondary spontaneous pneumothorax. The etiologic factors of secondary spontaneous pneumothorax were tuberculous origin in 50 cases, chronic bronchitis with emphysematous bullae or blebs in 17 cases, asthma in 10 cases and lung cancer in 3 cases. Closed thoracotomy was performed for reexpansion of collapsed lung in 153 cases, bed rest in 3 cases, needle aspiration in 5 cases and open thoracotomy in 14 cases. Closed thoracotomy was the main therapeutic approach of choice in the great majority of spontaneous pneumothorax with recurrence rate of 21.6%. However, open thoracotomy was undertaken in patients with continuous air leakage, recurrent episodes, bilateral pneumothorax and large visible apical blebs or bullae.

  • PDF

A Study on the Vibration Phenomena of the Duct-fan Systems in Fossil Fueled Boilers: Inlet Vortex Induced Excessive Vibration (화력 발전용 보일러 Duct/Fan 시스템의 진동현상에 대한 연구 : Inlet Vortex에 의한 과대진동 사례)

  • Kim, Cheol-Hong;Ju, Young-Ho;Byun, Hyung-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.82-87
    • /
    • 2000
  • During the operation, fatigue failures and cracks of duct plate due to excessive duct vibration occurred in the fan-duct systems of fossil fueled boilers. We measured static pressure variation(pressure pulsation) in the outlet, and also measured vibration at the outlet duct of a centrifugal fan. It was found that strong pressure pulsation caused by the inlet vortex occurred in inlet vane of centrifugal fan in the middle range of vane opening. Thus, excessive duct vibration is caused by strong pressure pulsation. In this paper, it is shown that the frequency and amplitude of pressure pulsation depend mainly on vane opening and are compared with duct vibration. Also, effective solution for reducing pressure pulsation and vibration are presented.

  • PDF

Study of Design Optimization of Reverse-Annular Type Combustor for Small Gas Turbine Engine (선회형 보염구조의 환형 역류형 연소기 최적화)

  • Park, Hee-Ho;Kim, Ki-Tae;Sung, Ok-Seok;Lim, Byeung-Jun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.04a
    • /
    • pp.401-405
    • /
    • 2011
  • Although the APU combustors were developed successfully, it could face many unexpected hardships in a engine or a system operated under the severe environment. This study is to be verified and settled by experimently and analytically of the problems and issues occurred in a variety of engine and system operation tests.

  • PDF