• Title/Summary/Keyword: Prestressing

Search Result 557, Processing Time 0.034 seconds

Flexural tests on two-span unbonded post-tensioned lightweight concrete beams

  • Yang, Keun-Hyeok;Lee, Kyung-Ho;Yoon, Hyun-Sub
    • Structural Engineering and Mechanics
    • /
    • v.72 no.5
    • /
    • pp.631-642
    • /
    • 2019
  • The objective of the present study is to examine the flexural behavior of two-span post-tensioned lightweight aggregate concrete (LWAC) beams using unbonded tendons and the reliability of the design provisions of ACI 318-14 for such beams. The parameters investigated were the effective prestress and loading type, including the symmetrical top one-point, two third-point, and analogous uniform loading systems. The unbonded prestressing three-wire strands were arranged with a harped profile of variable eccentricity. The total length of the beam, measured between both strand anchorages, was 11000 mm. The test results were compared with those compiled from simply supported LWAC one-way members, wherever possible. The ultimate load capacity of the present beam specimens was evaluated by the collapse mechanism of the plasticity theorem and the nominal section moment strength calculated following the provision of the ACI 318-14. The test results showed that the two-span post-tensioned LWAC beams had lower stress increase (Δfps) in the unbonded tendons than the simply supported LWAC beams with a similar reinforcement index. The effect of the loading type on Δfps and displacement ductility was less significant for two-span beams than for the comparable simply supported beams. The design equations for Δfps and Δfps proposed by ACI 318-14 and Harajli are conservative for the present two-span post-tensioned LWAC beams, although the safety decreases for the two-span beam, compared to the ratios between experiments and predictions obtained from simply supported beams.

Longitudinal Stress Distributions around Construction Joints of PSC Bridge Girders (PSC 교량의 시공이음부 종방향 응력 분포)

  • Im, Jung-Soon;Lee, Soo-Keun;Chae, Sung-Tae
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.2 no.3 s.6
    • /
    • pp.101-108
    • /
    • 2002
  • There exist many construction joints in segmentally constructed bridge girders. It is required coupling of tendons or overlapping of tendons to introduce continuous prestress through several spans of bridges. Even though tendon coupling method is easier to use in practice, some cracking problems around construction joints have been reported and complicated stress states around construction joints in PSC girders is not clearly investigated. The purpose of this paper is to investigate in detail the complicated longitudinal stress distributions around the construction joints in prestressed concrete girders with tendon couplers. To this end, a comprehensive experimental program has been set up and a series of specimens have been tested to identify the effects of tendon coupling and segmental construction of bridge sections. The present study indicates that the longitudinal stress distributions of PSC girders with tendon couplers are quite different from those of PSC girders without tendon couplers. The longitudinal compressive stresses introduced by prestressing are greatly reduced around coupled joints according to tendon coupling ratios.

Analytics Study on safety and stability of 50m class Portable Prestressing Bed (50m급 이동식 긴장대의 안전성 및 안정성에 관한 해석적 연구)

  • Kim, Jong Suk;Yoon, Ki Yong;Kim, Yong Hyeog
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.182-182
    • /
    • 2011
  • 현재 국내에서 PSC 거더의 제작은 주로 포스트텐션방식을 사용하고 있다. 포스트텐션방식은 콘크리트 양생 후 긴장력을 도입하여 제작회전율이 높은 특성을 가지나 쉬스, 그라우팅, 정착장치 등이 요구되어 조립과정이 복잡하고 제작단가가 높다. 교량에 적용되는 PSC 거더를 포스트텐션방식 대신에 프리텐션방식으로 제작한다면 제작단가를 대폭 감소시킬 수 있을 것이나, 교량용 PSC 거더의 길이가 일반적으로 30~50m이므로 공장에서 제작하여 현장으로 운반하는 것은 운반비용의 상승 및 운반 가능한 크기의 제한을 받게 된다. 운반의 문제를 해결하기 위해서는 현장에서 PSC 거더를 제작하여야 하는데 현장에 긴장대를 고정식으로 설치하는 것은 제작단가의 상승으로 이어져 경제성을 잃게 된다. 따라서 현장에서 사용할 수 있도록 이동식 긴장대를 제작한다면 경제성을 갖춘 프리텐션방식의 PSC 거더 생산이 가능할 것이다. 50m급 이동식 긴장대에는 약 10MN에 이르는 매우 큰 긴장력이 가해져 이동식 긴장대가 콘크리트 양생전까지 이 긴장력을 저항하여야 한다. 본 논문에서는 유한요소 해석프로그램인 ABAQUS를 사용하여 50m급 PSC 거더를 생산할 수 있는 이동식 긴장대를 모델링하여 약 10MN에 이르는 긴장력이 가해질 때에 이동식 긴장대의 각 구성요소의 거동특성 및 하중에 대한 안전성 및 좌굴에 대한 안정성 확보 여부를 해석적으로 파악하고자 한다. 이동식 긴장대는 구성요소인 정착블럭(긴장BOX)과 중간연결블럭으로 나누어 모델링하였다. 정착블럭(긴장BOX)은 다수의 강판을 4절점 쉘요소(S4R)를 사용하여 직육면체의 BOX 형상에 내부를 보강한 단면으로 구성하였고, 중간연결블럭은 H형강 2개를 일체화한 긴장대 거더와 콘크리트 바닥판 블록이 볼트로 합성된 구조이며, H형강은 4절점 쉘요소(S4R), 바닥판블럭은 8절점솔리드요소(C3D8R)를 사용하였다. 긴장대거더와 바닥판블럭은 합성거동을 하도록 weld option을 사용하여 부분적으로 결합하였다. 정적해석결과 이동식 긴장대에 발생하는 응력은 도로교 설계기준에 SS400 강재의 허용응력 140MPa 보다 작으며 선형탄성좌굴 해석결과 가력하중의 2.22배 약 21MN의 하중이 가력되어야 전체좌굴이 발생하게 될 것으로 추정된다. 해석결과를 보아 50m급 PSC 거더를 생산할 수 있는 이동식 긴장대는 하중에 대한 안전성 및 좌굴에 대한 안정성을 확보하고 있는 것으로 판단된다.

  • PDF

Analytical Method of Prestressed Concrete Members with Unbonded Tendons (부착되지 않은 텐돈을 갖는 프리스트레스트 콘크리트부재의 해석)

  • 문정호;이리형
    • Computational Structural Engineering
    • /
    • v.8 no.4
    • /
    • pp.75-85
    • /
    • 1995
  • The purpose of the present study is to develop a computer program which can be used to analyze prestressed concrete structures containing either bonded or unbonded tendons. To accomplish this, first, the concrete, nonprestressed, and prestressed steels are modeled with cyclic constitutive laws to take into account the various loading effects. Then, the hybrid-type element method is derived to improve the computations capability of stresses and strains, especially for the unbonded tendon. Since it allows one to determine the cross-sectional deformations in an element without any assumptions for its deformed shape, the element length can be much longer than that of the conventional finite element method. In order to achieve such a long element, various integral schemes are examined to implement them into the program. Then, the computational method for prestressing effects is developed consistently with the analytical method for the structure. Finally, analytical studies for actual tests were carried out to verify the program developed in this study.

  • PDF

A Development of Explicit Algorithm for Stress-Erection Analysis of STRARCH System (스트라치 시스템의 긴장응력해석을 위한 명시적 해석법의 개발)

  • Lee, Kyoung-Soo;Han, Sang-Eul
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.5
    • /
    • pp.513-520
    • /
    • 2011
  • In this paper, the advanced explicit algorithm is proposed to simulate the stress-erection process analysis of Strarch system. The Strarch(Stressed-Arch) system is a unique and innovative structural system and member prestress comprising prefabricated plane truss frames which are erected by a post-tensioning stress-erection procedure. The flexible bottom chord which have sleeve and gap detail are closed by the reaction force of prestressing tendon. The prestress imposing to the tendon will make the Strarch system to be erected. This post tensioning process is called as "stress-erection process". During the stress-erection process, the plastic rigid body rotation is occurred to the flexible top chord by the excessive amount of plastic strain, and the structural characteristic becomes to be unstable. In this study, the large deformational beam-column element with plastic hinge is used to model the flexible top chord, and the advanced Dynamic Relaxation method(DRM) are applied to the unstable problem of stress-erection process of Strarch system. Finally, the verification of proposed explicit algorithm is evaluated by analysing the stress-erection of real project of Strarch system.

Effect of Outrigger Wall Reinforced with Post Tension on Reducing Differential Column Shortening (포스트 텐션으로 보강된 아웃리거 벽체의 부등기둥축소량 저감 효과)

  • Lim, You-Jin;Kim, Han-Soo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.33 no.4
    • /
    • pp.237-244
    • /
    • 2020
  • This study investigates the effect of the outrigger wall reinforced with post-tension on reducing differential column shortening. Since the outrigger wall is a concrete structure, the effect of its long-term behavior should be considered. The long-term behavior of the outrigger wall increases differential column shortening and decreases the shear force acting on the outrigger. When the stiffness of the outrigger becomes small, the effect of its long-term behavior increases. Furthermore, a method of reinforcing with post-tension to reduce differential column shortening is proposed. Following the analysis, it was confirmed that the post-tension method shows a significant reduction in the differential column shortening. This study shows that the effect of the outrigger wall reinforced with post-tension on reducing differential column shortening increases with the prestressing force of tendon.

Analysis of the Linear Transformation of Prestressing Tendon Using Equivalent toad Method (등가하중법 관점에서 분석한 프리스트레싱 텐던의 직선이동)

  • 오병환;전세진
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.6
    • /
    • pp.843-850
    • /
    • 2002
  • Linear transformation theory has been effectively used in the design and analysis of prestressed concrete structures. The underlying assumptions of the theory, which were often overlooked, are investigated in the respect of equivalent load method. As a result, it is found that the same equivalent loading system is produced for all the cases of the linear transformation by the assumptions of the conventional equivalent load method. On the other hand, equivalent loading systems in a strict and accurate sense do not satisfy the classical theories of the linear transformation. Also, it is shown that a little different equivalent loading system from the conventional one is obtained for each linear transformation according to the proposed equivalent load method that is derived from the self-equilibrium property of the tendon-induced forces. Therefore, it can be concluded that the linear transformation theory is valid only when referring to the conventional approximate equivalent load method. The discussions are further extended to the eccentrically located circumferential tendon in the wall of containment structures, where the problem of eccentricity is analyzed also from the view point of the linear transformation.

An Experimental Study on Compressive Loading Capacity of PCT System (PCT System의 압축내하력에 관한 실험적 연구)

  • Han, Man-Yup;Kim, Jae-Hong;Kang, Sang-Hun;Jin, Kyung-Seok;Jeon, Yong-Sik;Cho, Byung-Ku
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.41-44
    • /
    • 2008
  • The PCT that supports the walls of long span temporary shoring facility is previously manufactured in the way of prestressing, and it which is composed of concrete is improved precast structure to satisfy enough stiffness. The components of PCT are manufactured as a fixed form, and they are close to the inner side of the wall of temporary shoring facility by fixed means in PCT. PCT system as support structure is that the ends of concrete filled segment members are united by the means of connection and also they have connection hole. In this study, PCT has enough bearing power for the long span temporary shoring facility, and also make the term of work reduce due to that the time of curing reduce through the method of precast.

  • PDF

Web-shear capacity of prestressed hollow-core slab unit with consideration on the minimum shear reinforcement requirement

  • Lee, Deuck Hang;Park, Min-Kook;Oh, Jae-Yuel;Kim, Kang Su;Im, Ju-Hyeuk;Seo, Soo-Yeon
    • Computers and Concrete
    • /
    • v.14 no.3
    • /
    • pp.211-231
    • /
    • 2014
  • Prestressed hollow-core slabs (HCS) are widely used for modern lightweight precast floor structures because they are cost-efficient by reducing materials, and have excellent flexural strength and stiffness by using prestressing tendons, compared to reinforced concrete (RC) floor system. According to the recently revised ACI318-08, the web-shear capacity of HCS members exceeding 315 mm in depth without the minimum shear reinforcement should be reduced by half. It is, however, difficult to provide shear reinforcement in HCS members produced by the extrusion method due to their unique concrete casting methods, and thus, their shear design is significantly affected by the minimum shear reinforcement provision in ACI318-08. In this study, a large number of shear test data on HCS members has been collected and analyzed to examine their web-shear capacity with consideration on the minimum shear reinforcement requirement in ACI318-08. The analysis results indicates that the minimum shear reinforcement requirement for deep HCS members are too severe, and that the web-shear strength equation in ACI318-08 does not provide good estimation of shear strengths for HCS members. Thus, in this paper, a rational web-shear strength equation for HCS members was derived in a simple manner, which provides a consistent margin of safety on shear strength for the HCS members up to 500 mm deep. More shear test data would be required to apply the proposed shear strength equation for the HCS members over 500 mm in depth though.

Design of longitudinal prestress of precast decks in twin-girder continuous composite bridges (2거더 연속강합성 교량의 프리캐스트 바닥판 종방향 프리스트레스 설계)

  • Shim, Chang Su;Kim, Hyun Ho;Ha, Tae Yul;Jeon, Seung Min
    • Journal of Korean Society of Steel Construction
    • /
    • v.18 no.5
    • /
    • pp.633-642
    • /
    • 2006
  • Serviceability design is required to control the cracking at the joint of precast decks with longitudinal prestress in continuous composite bridges. Details of twin-girder bridges are especially complex not only due to their main reinforcements and transverse prestresses for the design of long-span concrete slabs, but also due to the shear pockets for obtaining the composite action. This paper suggests the design guidelines for the magnitude of the effective prestress and for the selection of filling materials and their requirements that would allow for the use of precast decks for twin-girder continuous composite bridges. The necessary initial prestress was also evaluated through long-term behavior analysis. From the analysis, existing design examples were revised and their effectiveness was estimated. When a filling material with a bonding strength higher than the requirement is used in the region of a high negative moment, a uniform configuration of the longitudinal prestressing steels along thewhole span length of continuous composite bridges can be achieved, which would result in the simplification of the details and the reduction of the construction costs.