Effect of Outrigger Wall Reinforced with Post Tension on Reducing Differential Column Shortening

포스트 텐션으로 보강된 아웃리거 벽체의 부등기둥축소량 저감 효과

  • Received : 2020.02.17
  • Accepted : 2020.06.02
  • Published : 2020.08.31

Abstract

This study investigates the effect of the outrigger wall reinforced with post-tension on reducing differential column shortening. Since the outrigger wall is a concrete structure, the effect of its long-term behavior should be considered. The long-term behavior of the outrigger wall increases differential column shortening and decreases the shear force acting on the outrigger. When the stiffness of the outrigger becomes small, the effect of its long-term behavior increases. Furthermore, a method of reinforcing with post-tension to reduce differential column shortening is proposed. Following the analysis, it was confirmed that the post-tension method shows a significant reduction in the differential column shortening. This study shows that the effect of the outrigger wall reinforced with post-tension on reducing differential column shortening increases with the prestressing force of tendon.

본 논문에서는 포스트 텐션으로 보강된 아웃리거 벽체의 부등기둥축소량 저감 효과를 확인하였다. 아웃리거 벽체 시스템을 사용할 경우 콘크리트 부재를 아웃리거로 사용하기 때문에 아웃리거 벽체의 장기거동도 고려해야 한다. 아웃리거 벽체은 깊은 보의 형태로 전단 응력이 지배적이기 때문에 전단 응력을 받는 콘크리트의 장기거동에 대한 이론 연구를 수행하였고 그 결과를 유한요소해석에 적용하였다. 아웃리거의 장기거동 고려 시 부등기둥축소량과 아웃리거에 작용하는 전단력을 확인하였으며, 설계 변수인 아웃리거의 두께를 변경해가며 해석하였다. 해석 결과 부등기둥축소량은 증가하고 아웃리거에 작용하는 전단력은 감소함을 밝혔으며 아웃리거의 강성이 작을수록 그 효과가 크다는 것을 밝혔다. 이후 아웃리거의 장기거동으로 인해 증가한 부등기둥축소량을 감소시키기 위해 포스트 텐션 공법으로 보강하는 방법을 제안하고 그 효과를 확인하였다. 프리스트레스 도입 직후의 프리스트레스 손실과 장기거동에 의한 프리스트레스 손실을 모두 고려하였다. 해석 결과 포스트 텐션 공법의 뛰어난 부등기둥축소량 저감 효과를 확인하였으며, 프리스트레스의 크기가 증가할수록 그 효과가 증가함을 밝혔다.

Keywords

References

  1. Bazant, Z.P., Yu, Q., Li, G.H. (2012) Excessive Long-Time Deflections of Prestressed Box Girders. I: Record-Span Bridge in Palau and Other Paradigms, J. Struct. Eng., 138(6), pp.676-686. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000487
  2. CEB-FIP(Comite Euro-International Du Beton) (2010) CEB-FIP Model Code 2010, Thomas Telford Services Ltd, London, p.292.
  3. Fintel, M., Ghosh, S.K., Iyengar, H. (1987) Column Shortening in Tall Structure-Prediction and Compensation, Portland Cement Association, Skokie, p.35.
  4. Kim, H.S. (2013) Effect of Horizontal Members on Column Shortening of Reinforced Concrete Building Structures, Struct. Des. Tall& Special Build., 22, pp.440-453. https://doi.org/10.1002/tal.696
  5. Kim, H.S., Lim, Y.J., Lee, H.L. (2019) Strength Demand of Dual-Purpose Outrigger System for Reducing Lateral Displacement and Differential Axial Shortening in a Tall Building, Struct. Des. Tall& Special Build., e1701, pp.1-19.
  6. Moragaspitiya, P., Thambiratnam, D., Perera, N., Chan, T. (2010) A Numerical Method to Quantify Differential Axial Shortening in Concrete Buildings, Eng. Struct., 32, pp.2310-2317. https://doi.org/10.1016/j.engstruct.2010.04.006
  7. Park, S.W., Choi, S.W., Park, H.S. (2013) Moving Average Correction Method for Compensation of Differential Column Shortenings in High-Rise Buildings, Struct. Des. Tall& Special Build., 22, pp.718-728. https://doi.org/10.1002/tal.722
  8. Samarakkody, D.I., Thambiratnam, D.P., Chan, T.H.T., Moragaspitiya, P.H.N. (2017) Differential Axial Shortening and Its Effects in High Rise Buildings with Composite Concrete Filled Tube Columns, Constr. & Build. Mater., 143, pp.659-672. https://doi.org/10.1016/j.conbuildmat.2016.11.091
  9. Zou, D., Liu, T., Teng, J., Du, C., Li, B. (2014) Influence of Creep and Drying Shrinkage of Reinforced Concrete Shear Walls on the Axial Shortening of High-Rise Buildings, Constr. & Build. Mater., 55, pp.46-56. https://doi.org/10.1016/j.conbuildmat.2014.01.034