• 제목/요약/키워드: Pressure-drop Coefficient

검색결과 382건 처리시간 0.024초

Plate and Shell 열교환기내의 R-22 증발열전달 및 압력강하 특성에 관한 실험적 연구 (Evaporation Heat Transfer and Pressure Drop Characteristics of Refrigerant R-22 in a P1ate and Shell Heat Exchanger)

  • 서무교;박재홍;김영수
    • 대한기계학회논문집B
    • /
    • 제25권10호
    • /
    • pp.1318-1326
    • /
    • 2001
  • The evaporation heat transfer coefficient and pressure drop for refrigerant R-22 flowing in the plate and shell heat exchanger were investigated experimentally in this study. Two vertical counterflow channels were farmed in the exchanger by three plates of commercial geometry with a corrugated trapezoid shape of a chevron angel of 45 ° Upflow boiling of refrigerant R-22 in one channel receives heat from the hot downf1ow of water in the other channel. The effects of the mean vapor quality, mass flux, heat flux and pressure of R-22 on the evaporation heat transfer and pressure drop were explored. The quality change of R-22 between the inlet and outlet of the refrigerant channel ranges from 0.03 to 0.05. The present data showed that both the evaporation heat transfer coefficient and pressure drop increase with the vapor quality. At a higher mass flux, the evaporation heat transfer coefficient and pressure drop are higher for the entire range of the vapor quality Raising the imposed wall heat flux was found to slightly improve the heat transfer, while at a higher refrigerant pressure, both the heat transfer and pressure drop are slightly lower.

3,000psi급 소형 퀵 커플러 내부유동에 관한 수치해석 (Numerical Analysis of the Internal Flow of Small Quick Coupler at 3,000psi)

  • 안희학;이중섭
    • 한국기계가공학회지
    • /
    • 제15권2호
    • /
    • pp.16-21
    • /
    • 2016
  • This study is a numerical analysis of the flow characteristic of a quick coupler. The quick coupler is a popular coupling tool for pipelines in hydraulic and pneumatic systems. In this study, the flow characteristic of a quick coupler outlet is conducted about the flow coefficient. The quick coupler is analyzed for improving flow and confirmed with the study results. The velocities with pressure distribution according to inlet and outlet pressure drop of the coupler are also compared. The flow coefficient is analyzed according to the flow analysis result for each pressure drop. When the pressure drop is 1 psi, the flow coefficient (Cv) matched about 98% of the value provided by the actual product.

Condensation Heat Transfer of R22, R407C, and R410A in Slit Fin-and-Tube Heat Exchanger

  • Jeon, Chang-Duk;Lee, Jin-Ho
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제11권4호
    • /
    • pp.188-198
    • /
    • 2003
  • R410A and R407C are considered to be alternative refrigerants of R22 for the air-conditioners. An experimental study is carried out to investigate the effect of the change of mass flow rate on the characteristics of heat transfer and pressure drop in three row slit finned-tube heat exchanger for R407C, R410A and R22. R407C, a non-azeotropic refrigerant mixture, exhibited a quite different condensation phenomenon from those of R22 and R410A and its condensation heat transfer coefficient was much lower than that of R22 and R410A. On the other hand, the condensation heat transfer coefficient of R410A, near-azeotropic refrigerant mixture, was a little higher than that of R22. R410A also showed the lowest condensation pressure drop across the test section. For all refrigerants, the condensation heat transfer coefficient and pressure drop increase as the mass flux increases. The condensation heat transfer coefficient correlation proposed by Kedzierski shows the best agreement with the experimental data within $\pm$20%.

Oblong 셀 앤 플레이트 열교환기에서의 단상 열전달, 압력강하 특성 및 성능예측 프로그램 개발에 관한 연구 (Study on Single-Phase Heat Transfer, Pressure Drop Characteristics and Performance Prediction Program in the Oblong Shell and Plate Heat Exchanger)

  • 권용하;김영수;박재홍
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권6호
    • /
    • pp.1026-1036
    • /
    • 2004
  • In this study, single-phase heat transfer experiments were conducted with Oblong Shell and Plate heat exchanger using water. An experimental water loop has been developed to measure the single-phase heat transfer coefficient and pressure drop in a vertical Oblong Shell and Plate heat exchanger. Downflow of hot water in one channel receives heat from the cold water upflow of water in the other channel. Similar to the case of a plate heat exchanger, even at a very low Reynolds number, the flow in the Oblong Shell and Plate heat exchanger remains turbulent. The present data show that the heat transfer coefficient and pressure drop increase with the Reynolds number. Based on the present data, empirical correlations of the heat transfer coefficient and pressure drop in terms of Nusselt number and friction factor were proposed. Also, performance prediction analyses for Oblong Shell and Plate heat exchanger were executed and compared with experiments. $\varepsilon$-NTU method was used in this prediction program. Independent variables are flow rates and inlet temperatures. Compared with experimental data, the accuracy of the program is within the error bounds of $\pm$5% in the heat transfer rate.

4.3 mm 세관내 R-22와 R-407C의 증발 열전달과 압력강하 (Evaporation Heat Transfer and Pressure Drop of Mixture Refrigerant R-22 and R-407C in a Diameter of 4.3 mm)

  • 노건상;손창효
    • 동력기계공학회지
    • /
    • 제12권4호
    • /
    • pp.26-31
    • /
    • 2008
  • The evaporation heat transfer coefficient and pressure drop of R-22 and R-407C in a small diameter copper tube were investigated experimentally. The main components of the refrigerant loop are a receiver, a compressor, a mass flow mete, a condense and a double pipe type evaporate (test section). The test section consists of a smooth copper tube of 4.3 mm inner diameter. The refrigerant mass fluxes were varied from 100 to $300[kg/m^{2}s]$ and the saturation temperature of evaporator were $5[^{\circ}C]$. The evaporation heat transfer coefficients of R-22 and R-407C increase with the Increase in mass flux and vapor quality. The evaporation heat transfer coefficient of R-22 is about $7.3\sim47.1%$ higher than that of R-407C. The evaporation pressure drop of R-22 and R-407C increase with the increase of mass flux. The pressure drop of R-22 is about $8\sim20%$ higher than that of R-407C.

  • PDF

냉각유로 내 곡관부 및 유로의 회전이 압력강하에 미치는 영향 (Pressure Drop Characteristics in a Coolant Passage With Turning Region and Rotation)

  • 김경민;조형희
    • 한국유체기계학회 논문집
    • /
    • 제10권2호
    • /
    • pp.32-40
    • /
    • 2007
  • The present study investigated local pressure drop in a rotating smooth square duct with turning region. The duct has a hydraulic diameter $(D_h)$ of 26.7mm and a divider wall of 6.0mm or $0.225D_h$. The distance between the tip of the divider and the outer wall of the duct is $1.0D_h$. The Reynolds number (Re) based on the hydraulic diameter is kept constant at 10,000, and the rotation number (Ro) is varied from 0.0 to 0.20. The pressure coefficient distribution $(C_p)$, the friction factor (f) and the thermal performance $({\eta})$ are presented on the leading, the trailing and the outer surfaces. It is found that the curvature of the $180^{\circ}-turn$ produces Dean vortices that cause the high pressure drop in the turning region. The duct rotation results in the pressure coefficient discrepancy between the leading and trailing surfaces. That is, the high pressure values appear on the trailing surface in the first-pass and on the leading and side surfaces in the second-pass. As the rotation number increases, the pressure discrepancy enlarges. In the fuming region, a pair of the Dean vortices in the stationary case transform into one large asymmetric vortex cell, and then the pressure drop characteristics also change.

흡연집진기 내 스트레이너 및 카본필터 압력투과 해석 (Dust collector strainer and carbon filter pressure permeation analysis)

  • 이치우
    • 동력기계공학회지
    • /
    • 제19권4호
    • /
    • pp.5-10
    • /
    • 2015
  • Dust collector is one of the most widely used equipment among the method of separating particles, it filters exhaust gas having various kinds of dusts through several filters installed on parallel. This research investigated the moving characteristic of Honeycomb-type carbon filter in pressure drop of smoking collector's ventilation system. It also compared pressure transmission coefficient through pressure drop according to flow velocity change.

흰-관 열교환기에서 재료절감 흰의 제습특성 (Dehumidifying Performance of Material-Saving Fin in Fin-tube Heat Exchanger)

  • 강희찬;김무환
    • 설비공학논문집
    • /
    • 제13권8호
    • /
    • pp.730-738
    • /
    • 2001
  • This work discusses the pressure droop, heat and mass transfer of the finned-tube heat exchangers having 7 mm tubes and offset strips in dehumidifying applications. It focuses on the fin material saving and the reduction of pressure drop. The experiment was conducted using three times scaled-up models to simulate the performance of the prototype. Eight kinds of fins having different strips and S shape edges were tested. the area density of the strip was a major factor and its shape and the location were secondary factors on the pressure drop, the heat and mass transfer. The reduced-area fin can almost equal the non-reduced fin in the aspect of heat and mass transfer. The strip fins proposed in the present work can considerably reduce both the pressure drop and the fin material for similar thermal load.

  • PDF

쓰레기 관로이송 시스템에서의 관로 압력손실 평가 (Evaluation of Pressure Drop in a Circular Pipe of Refuse Collecting System)

  • 김동우;장춘만
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2615-2620
    • /
    • 2007
  • This paper describes on pressure drop in a circular pipe of refuse collecting system. The flow characteristics inside the circular pipe are analyzed by three-dimensional Navier-Stokes analysis. In numerical analysis, an organic waste is modeled using the data obtained by site survey. Pressure drop obtained by numerical simulation is compared to the value obtained by experimental measurements for the two kinds of pipe; straight and bended type. The pressure drop obtained by numerical simulation has a good agreement with that of experiments. It is noted that the accurate prediction of pressure drop in the waste pipe is very important to determine the performance of turbo blower used in making a suction pressure in the waste pipe. Especially, the pressure drop for an organic waste is analyzed according to the mass flow rate of waste.

  • PDF

용접형 판형 열교환기의 열전달 및 압력강하 특성에 관한 실험적 연구 (Experimental study of Heat Transfer and Pressure Drop Characteristics for the Welded Plate Heat Exchanger)

  • 정종윤;김성수;강용태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.419-424
    • /
    • 2008
  • Heat transfer and pressure drop characteristics of welded plate heat exchanger are studied to apply it for the solution heat exchanger of 210RT absorption system. This study quantifies the effect of mass flow rate and strong solution concentration on the heat transfer coefficient and pressure drop in the plate heat exchanger. The concentration of weak solution is fixed at 55% and the strong solution varies 55%, 57%, and 59% in mass. The results show that the overall heat transfer coefficient and pressure drop increase linearly with increasing Reynolds number. It is also found that the heat transfer coefficient of hot side increases with increasing the concentration of strong solution while the strong solution concentration has no effect on heat transfer coefficient of cold side.

  • PDF