DOI QR코드

DOI QR Code

Numerical Analysis of the Internal Flow of Small Quick Coupler at 3,000psi

3,000psi급 소형 퀵 커플러 내부유동에 관한 수치해석

  • Ahn, Hee-Hak (Research & Development Center, DK-LOK LTD., CO.) ;
  • Yi, Chung-Seob (Gyeognam National University of Science and Technology, Industry-Academic corporation foundation)
  • 안희학 (디케이락(주)기술연구소) ;
  • 이중섭 (경남과학기술대학교 산학협력단)
  • Received : 2015.07.05
  • Accepted : 2016.01.08
  • Published : 2016.04.30

Abstract

This study is a numerical analysis of the flow characteristic of a quick coupler. The quick coupler is a popular coupling tool for pipelines in hydraulic and pneumatic systems. In this study, the flow characteristic of a quick coupler outlet is conducted about the flow coefficient. The quick coupler is analyzed for improving flow and confirmed with the study results. The velocities with pressure distribution according to inlet and outlet pressure drop of the coupler are also compared. The flow coefficient is analyzed according to the flow analysis result for each pressure drop. When the pressure drop is 1 psi, the flow coefficient (Cv) matched about 98% of the value provided by the actual product.

Keywords

References

  1. Kim. B. S., Ryu. J. K. and Baek. J. H., "A Design of Quick Coupler in the Drive Mechanism for Unmanned Robot" Proceedings of KSPE Autumn Conference, pp. 798-790, 2011.
  2. Skousen, P. L., Valve Handbook, Second Edition, McGraw-Hill, 2009.
  3. Lee. J. H. and Sung. J. K., "A Comparative Study on the Improvement of the Performance of Swivel Valve Tube Couplers," Journal of Korean Society of Manufacturing Process Engineers, Vol. 9, No. 5, pp. 20-27, 2010.
  4. Kim. K. W., Jung. I. S., Chung. H. T., Park. T. J. and Cho. Y. M., "Flow Analysis of Industrial Hydraulic Coupler Using CFD Methods", Proceedings of KSME 2009 Spring Annual Meeting, pp. 383-387, 2009.
  5. Ahn, Y. J., Kim, B. J. and Shin, B. R., "Numerical Analysis on Flow Characteristics of High Pressure Drop Control Valve with Anti-Cavitation Trim," Journal of Fluid Machinery, Vol. 10, No. 4, pp. 61-70, 2007. https://doi.org/10.5293/KFMA.2007.10.4.061
  6. Kwak. K. M., Cho. J. S., Kim. J. D. and Lee. J. H., "A Study on Flow Coefficient and Flow Characteristics for Butterfly Valve by Numerical Analysis," Journal of Korean Society of Manufacturing Process Engineers, Vol. 11, No. 4, pp. 62-65, 2012.
  7. Park. S. W., Choi. I. S., Noh. K. C., Ryu. S. P. and Yoon. K. S., "An Experimental Study on Measurement of Flow Coefficient Using the Steady-Flow Test Rig," Journal of the Korean Society of Marine Engineering, Vol. 36, No. 4, pp. 423-429, 2012. https://doi.org/10.5916/jkosme.2012.36.4.423

Cited by

  1. Cone Type 밸브 내부유동 수치해석에 관한 연구 vol.23, pp.2, 2020, https://doi.org/10.21289/ksic.2020.23.2.199
  2. 3/8" 유압 퀵 커플러의 피스톤형상을 고려한 최적설계에 관한 연구 vol.20, pp.2, 2016, https://doi.org/10.14775/ksmpe.2021.20.02.066
  3. Comparison of Loss Coefficient using 1-inch Ball and Glove Valve Opening Ratio vol.20, pp.9, 2021, https://doi.org/10.14775/ksmpe.2021.20.09.063