• Title/Summary/Keyword: Pressure tank

Search Result 840, Processing Time 0.032 seconds

Development of a University-Based Simplified H2O2/PE Hybrid Sounding Rocket at KAIST

  • Huh, Jeongmoo;Ahn, Byeonguk;Kim, Youngil;Song, Hyunki;Yoon, Hosung;Kwon, Sejin
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.18 no.3
    • /
    • pp.512-521
    • /
    • 2017
  • This paper reports development process of a university-based sounding rocket using simplified hybrid rocket propulsion system for low-altitude flight application. A hybrid propulsion system was tried to be designed with as few components as possible for more economical, simpler and safer propulsion system, which is essential for the small scale sounding rocket operation as a CanSat carrier. Using blow-down feeding system and catalytic ignition as combustion starter, 250 N class hybrid rocket system was composed of three components: a composite tank, valves, and a thruster. With a composite tank filled with both hydrogen peroxide($H_2O_2$) as an oxidizer and nitrogen gas($N_2$) as a pressurant, the feeding pressure was operated in blowdown mode during thruster operation. The $MnO_2/Al_2O_3$ catalyst was fabricated for propellant decomposition, and ground test of propulsion system showed the almost theoretical temperature of decomposed $H_2O_2$ at the catalyst reactor, indicating sufficient catalyst efficiency for propellant decomposition. Auto-ignition of the high density polyethylene(HDPE) fuel grain successfully occurred by the decomposed $H_2O_2$ product without additional installation of any ignition devices. Performance test result was well matched with numerical internal ballistics conducted prior to the experimental propulsion system ground test. A sounding rocket using the developed hybrid rocket was designed, fabricated, flight simulated and launch tested. Six degree-of-freedom trajectory estimation code was developed and the comparison result between expected and experimental trajectory validated the accuracy of the developed trajectory estimation code. The fabricated sounding rocket was successfully launched showing the effectiveness of the simplified hybrid rocket propulsion system.

Effect of Coagulant addition on Nutrient Removal Efficiency in a Submerged Membrane Bioreactor (응집제의 첨가에 따른 Membrane bioreactor 의 고도처리 효율 연구)

  • Park, Jong-Bu
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.2
    • /
    • pp.235-241
    • /
    • 2011
  • This study was performed to investigate the characteristics of nutrient removal of municipal wastewater in the submerged membrane bioreactor by addition of alum directly into aerobic tank. Membrane bioreactor consists of three reactors such as two intermittent anaerobic tanks and the aerobic tank with hollow fiber membrane. The removal efficiencies of $COD_{cr}$, BOD, SS, TN and TP on the membrane bioreactor were 94.0%, 99.1%, 99.9%, 66.9%, and 58.9%, respectively. In addition, The removal efficiencies of $COD_{cr}$, BOD, SS, TN and TP on the membrane bioreactor with alum addition were 93.4%, 99.0%, 99.9%, 63.2%, and 96.8%, respectively. There was little difference between them on the nutrient removal efficiencies except phophorus removal. The estimated sludge production, specific denitrification rate, specific nitrification rate and phosphorus removal content on the membrane bioreactor were 1.76 kgTSS/d, $0.055mgNO_3-N/mgVSS{\cdot}d$, $0.031mgNH_4-N/mgVSS{\cdot}d$, and 0.095 kgP/d, respectively. And The estimated sludge production, specific denitrification rate, specific nitrification rate and phosphorus removal content on the membrane bioreactor with alum addition were 2.90 kgTSS/d, $0.049mgNO_3-N/mgVSS{\cdot}d$, $0.030mgNH_4-N/mgVSS{\cdot}d$, and 0.160 kgP/d, respectively. The alum content added was 1.7 molAl/molP on an average. The increasing ratio of tran-membrane pressure on the membrane bioreactor was $0.0056kgf/cm^2{\cdot}compared$ to $0.0033kgf/cm^2{\cdot}d$ on the membrane bioreactor with alum addition. There was a slightly reduction effect on membrane fouling by alum addition.

Numerical Analysis of Wave Energy Extraction Performance According to the Body Shape and Scale of the Breakwater-integrated Sloped OWC

  • Yang, Hyunjai;Min, Eun-Hong;Koo, WeonCheol
    • Journal of Ocean Engineering and Technology
    • /
    • v.35 no.4
    • /
    • pp.296-304
    • /
    • 2021
  • Research on the development of marine renewable energy is actively in progress. Various studies are being conducted on the development of wave energy converters. In this study, a numerical analysis of wave-energy extraction performance was performed according to the body shape and scale of the sloped oscillating water column (OWC) wave energy converter (WEC), which can be connected with the breakwater. The sloped OWC WEC was modeled in the time domain using a two-dimensional fully nonlinear numerical wave tank. The nonlinear free surface condition in the chamber was derived to represent the pneumatic pressure owing to the wave column motion and viscous energy loss at the chamber entrance. The free surface elevations in the sloped chamber were calculated at various incident wave periods. For verification, the results were compared with the 1:20 scaled model test. The maximum wave energy extraction was estimated with a pneumatic damping coefficient. To calculate the energy extraction of the actual size WEC, OWC models approximately 20 times larger than the scale model were calculated, and the viscous damping coefficient according to each size was predicted and applied. It was verified that the energy, owing to the airflow in the chamber, increased as the incident wave period increased, and the maximum efficiency of energy extraction was approximately 40% of the incident wave energy. Under the given incident wave conditions, the maximum extractable wave power at a chamber length of 5 m and a skirt draft of 2 m was approximately 4.59 kW/m.

Tasks for Development of Autogenous Pressurization System and Construction of Test Equipment (자가증기 가압시스템 개발과제 및 모사시험설비 구성)

  • Cheulwoong Kim;Jisung Yoo;Sangyeon Ji;Jae Sung Park
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.27 no.1
    • /
    • pp.49-57
    • /
    • 2023
  • The autogenous pressurization has been widely adopted for propulsion systems of next-generation reusable rockets due to its low cost and high reliability. The autogenous pressurization has a simple structure, but an understanding of the heat and mass transfer occurring inside the tank is essential. For this reason, a simulation test of the autogenous pressurization was conceived. The experiment equipment was constructed based on overseas pressurization test facilities cases and expert advice. Unlike the actual autogenous pressurization system, the propellant tank was insulated to exclude external influences. The pressurized gas supply line and the propellant pipe were separated. Using the manufactured autogenous pressure experiment equipment, it is possible to evaluate the condensation phenomenon of pressurants in cryogenic propellants, comparison of the efficiency of pressurization using helium and evaporated gas and the pressurization capacity according to the temperature of pressurant.

A Study on the Construction of the Gas Conversion Process System for a Pilot Plant Using a Small-scale Hydrogen Liquefaction System (소규모 수소 액화 시스템을 활용한 파일럿 플랜트의 기체 전환 공정 시스템 구축에 관한 연구)

  • YOUNG MIN SEO;HYUN WOO NOH;TAE HYUNG KOO;ROCK KIL KO;DONG WOO HA
    • Journal of Hydrogen and New Energy
    • /
    • v.35 no.4
    • /
    • pp.353-362
    • /
    • 2024
  • In this study, several studies were conducted on the construction of gas conversion process system for a pilot plant using a small-scale hydrogen liquefaction system. The pilot plant considered in this study includes a liquefier, a storage tank, an evaporator, a gas booster, and a gas storage tank. First, the suspected leak area of the container was checked using the sprayed method of helium gas. The small-scale hydrogen liquefaction system was designed based on the analysis results of the pre-cooling system and the liquefaction system. Additionally, the program was developed to maintain pressure within vessel for an automatic production of liquid hydrogen. The evaporator for liquid hydrogen was manufactured based on the designed analysis data, and the pollution of gas in the vessel was analyzed through a gas recovery line system.

Characteristics and Causes of Wave-Induced Settlement in Caisson Breakwater: Focusing on Settlement Data (파랑에 의한 방파제 케이슨 침하 경향 및 원인 분석: 침하 계측자료를 중심으로)

  • Kim, Tae-Hyung;Nam, Jung-Man;Kim, In-Sok;Yun, Seong-Kyu
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.7
    • /
    • pp.27-40
    • /
    • 2014
  • So far, studies on the settlement of breakwater have mainly been conducted through numerical model tests focusing on an analysis or through the laboratory wave tank tests using a scaled model. There has not been a study on the settlement that is measured in an actual breakwater structure. This study analyzed the data of settlement that has been measured in an actual caisson breakwater for a long time and the characteristics and causes of wave-induced settlement in the caisson (including beneath ground), based on qualitative aspect, were examined. The analysis revealed that wave clearly has an effect on the settlement in caisson, especially in the condition of high wave such as typhoon. Caisson settlement is caused by the liquefaction of ground, which is due to the increase of excess pore pressure, the combination of oscillatory excess pore pressure and residual excess pore water pressure, and the solidification process of ground due to dissipation of the accumulated excess pore pressure. The behavior of excess pore pressure in the ground beneath the caisson is entirely governed by the behavior of the caisson. Ground that has gone through solidification is not likely to go through liquefaction in a similar or a smaller wave condition and consequently, the possibility of settlement is reduced.

Design of Portable Welded-Nitrogen Vessel (11 kg, 10 L and 50 bar) for Shipbuilding (선박용 휴대형 질소용기(11 kg, 10 L 및 50 bar)의 두께 및 외형 설계)

  • Seong, Hansaem;Kim, Jaeyeol;Eom, Taejin;Kawk, Hyo Seo;Lee, Kwang O;Kim, Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.4
    • /
    • pp.263-270
    • /
    • 2017
  • The shipbuilding industry uses large stationary tanks to store low-pressure air, which is used to open and close large shut-off valves. However, when supplying air from the tank to a distant valve, there are problems related to the need for supplementary pipes and the pressure drop during transportation. In this study, a portable welded vessel for storing high-pressure nitrogen (11 kg, 10 L, and 50 bar) was designed to prevent air leakage and improve the convenience of workers. This pressure vessel was elliptical to reduce the number of welded parts, which are structurally weak. The thickness and ratio of the major and minor axes of the pressure vessel were calculated to verify its structure stability at the working pressure (50 bar), and that the proposed weight and capacity were satisfactory. The residual stress caused by the welding process was calculated by performing a transient thermal-structural coupled field analysis using the ANSYS parametric design language (APDL), and the fatigue life of the vessel was verified based on the Goodman criterion.

A Study on Standards for Pressure Relief Valve Vent Pipes from LPG Storage Tanks (LPG용 압력방출밸브 방출관 설치기준 개선방안)

  • Lee, Jin-Han;Eom, Suk-Hwa;Kim, Lae-Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.4
    • /
    • pp.59-64
    • /
    • 2012
  • The dispersion of gas discharged from the vent pipes of pressure relief valves attached LPG (Liquefied Petroleum Gas) storage tank was studied. In general, vent pipes should be positioned so that they discharge vertically upwards in a safe place, and installed so that, in the event of ignition of discharged gas, flame impingement on any vessel, equipment or piping is avoided[1][2]. In Korea, on the other hand, there are various type of the end of vent pipes because there is no rule for discharge directions from the vent pipes. In this paper, we took 4 types of vent directions from the pipes in to account, such as vertically upward, vertically downward, vertically 4-way and horizontally 2-way direction. A software package, FLACS, was adopted to simulate gas dispersion from the vent pipes. We found that vertically downward, vertically 4-way and horizontally 2-way discharge from vent pipes were undesirable to avoid ignition on near ground. Therefore, it was obvious that vertically upward opening of a vent pipe is the best option to discharge in a safe place.

The heat transfer and pressure drop characteristics of $CO_2$ during supercritical region in a horizontal tube (초임계 영역에서 수평관내 $CO_2$ 열전달과 압력강하)

  • 이동건;오후규;김영률;손창효
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.3
    • /
    • pp.500-508
    • /
    • 2004
  • The heat transfer coefficients during gas cooling process of carbon dioxide in a horizontal tube were investigated. The experiments are conducted without oil in the refrigerant loop. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater, and a gas cooler(test section). The water loop consists of a variable-speed pump, an isothermal tank, and a flow meter. The gas cooler is a counterflow heat exchanger by cooled water flowing in the annulus. The $CO_2$ flows in the horizontal stainless steel tube. which is 9.53mm in O.D. and 7.75mm in I.D. The gas cooler is 6 [m] in length. which is divided into 12 subsections, respectively. The experimental conditions considered in the study are following range of variables : refrigerant temperature is between 20 and $100^{\circ}C$. mass fluxes ranged from 200 to 400kg/($m^2$.s), average pressure varied from 7.5 to 10.0MPa. The main results were summarized as follows : The friction factors of $CO_2$ in the gas cooler show a relatively good agreement with those predicted by Blasius' correlation. The local heat transfer coefficient in the gas cooler has compared with most of correlations, which are the famous ones for forced convection heat transfer of turbulent flow. The results show that the local heat transfer coefficient of gas cooler agrees well with the correlation by Bringer-Smith except that at the region near pseudo critical temperature. while that at the near pseudo critical temperature is higher than the correlation.

EXPERIMENTS ON THE PERFORMANCE SENSITIVITY OF THE PASSIVE RESIDUAL HEAT REMOVAL SYSTEM OF AN ADVANCED INTEGRAL TYPE REACTOR

  • Park, Hyun-Sik;Choi, Ki-Yong;Choi, Seok;Yi, Sung-Jae;Park, Choon-Kyung;Chung, Moon-Ki
    • Nuclear Engineering and Technology
    • /
    • v.41 no.1
    • /
    • pp.53-62
    • /
    • 2009
  • A set of experiments has been conducted on the performance sensitivity of the passive residual heat removal system (PRHRS) for an advanced integral type reactor, SMART, by using a high temperature and high pressure thermal-hydraulic test facility, the VISTA facility. In this paper the effects of the opening delay of the PRHRS bypass valves and the closing delay of the secondary system isolation valves, and the initial water level and the initial pressure of the compensating tank (CT) are investigated. During the reference test a stable flow occurs in a natural circulation loop that is composed of a steam generator secondary side, a secondary system, and a PRHRS; this is ascertained by a repetition test. When the PRHRS bypass valves are operated 10 seconds later than the secondary system isolation valves, the primary system is not properly cooled. When the secondary system isolation valves are operated 10 or 30 seconds later than the PRHRS bypass valves, the primary system is effectively cooled but the inventory of the PRHRS CT is drained earlier. As the initial water level of the CT is lowered to 16% of the full water level, the water is quickly drained and then nitrogen gas is introduced into the PRHRS, resulting in the deterioration of the PRHRS performance. When the initial pressure of the PRHRS is at 0.1MPa, the natural circulation is not performed properly. When the initial pressures of the PRHRS are 2.5 or 3.5 MPa, they show better performance than did the reference test.