• Title/Summary/Keyword: Pressure filtration

검색결과 356건 처리시간 0.025초

Chemical cleaning of fouled polyethersulphone membranes during ultrafiltration of palm oil mill effluent

  • Said, Muhammad;Mohammad, Abdul Wahab;Nor, Mohd Tusirin Mohd;Abdullah, Siti Rozaimah Sheikh;Hasan, Hassimi Abu
    • Membrane and Water Treatment
    • /
    • 제5권3호
    • /
    • pp.207-219
    • /
    • 2014
  • Fouling is one of the critical factors associated with the application of membrane technology in treating palm oil mill effluent (POME), due to the presence of high concentration of solid organic matter, oil, and grease. In order to overcome this, chemical cleaning is needed to enhance the effectiveness of membranes for filtration. The potential use of sodium hydroxide (NaOH), sodium chloride (NaCl), hydrochloric acid (HCl), ethylenediaminetetraacetic acid (EDTA), and ultrapure water (UPW) as cleaning agents have been investigated in this study. It was found that sodium hydroxide is the most powerful cleaning agent, the optimum conditions that apply are as follows: 3% for the concentration of NaOH, $45^{\circ}C$ for temperature solution, 5 bar operating pressure, and solution pH 11.64. Overall, flux recovery reached 99.5%. SEM images demonstrated that the membrane surface after cleaning demonstrated similar performance to fresh membranes. This is indicative of the fact that NaOH solution is capable of removing almost all of the foulants from PES membranes.

내부구조물을 이용한 필터의 효율 및 수명 상승에 대한 연구 (Study on Filter Efficiency and Lifetime Enhancement by using Internal Structures)

  • 김지훈;윤상우;권성호;성수환;배문오;김주한
    • 한국기계가공학회지
    • /
    • 제17권5호
    • /
    • pp.149-154
    • /
    • 2018
  • To improve the efficiency and lifetime of filters, we analyze the element distribution at the entrance and exit by using the flow inside a filter, confirming that the internal structure affects the filter efficiency. The flow in the pipe is predicted through computer simulations, and the filtration efficiency of each element is compared through experiments. The efficiency and lifetime of the filter are indirectly improved through the element distribution at the filter outlet according to the internal structure. Because pressure loss from the structure inevitably occurs, the efficiency and lifetime of filters against pressure loss must be considered.

저압 막여과 혼성공정을 이용한 고도 정수처리 (Low Pressure Hybrid Membrane Processes for Drinking Water Treatment)

  • 추광호;정지현;박학순
    • 멤브레인
    • /
    • 제17권3호
    • /
    • pp.161-173
    • /
    • 2007
  • 현재 막여과 공정은 정수처리에서 많은 관심을 받고 있다. 그러나 막여과 공정은 저압 운전이 가능한 정밀/한외여과 분리막을 이용할 때는 효과적인 용존성 유기물 제거가 이루어지지 않으며 막오염 현상으로 분리막의 투과도 감소가 일어난다. 고압 분리막을 이용할 경우 양질의 수질은 얻을 수 있으나 고압 운전으로 인하여 운전비용의 소모가 높다. 따라서 최근 분리막의 효율적인 정수처리 적용과 성능 향상을 위해서 다른 물리화학적 공정과 결합한 혼성공정에 대한 다양한 접근이 이루어지고 있다. 본 연구에서는 혼성공정으로 응집, 흡착, 특정 화학반응, 막표면 코팅 등과 정밀/한외여과 공정을 결합한 경우의 특징, 처리효율, 고려사항 등을 고찰하였다.

충격기류식 여과집진장치에서 운전조건 변화로 인한 여과저항에 관한 연구[I] (Study on Filter Drag Due to the Change of Operation Conditions in a Pulse Air Jet-type Bag Filter[I])

  • 류재용;서정민;박정호;전보경;최금찬;손영일
    • 한국환경과학회지
    • /
    • 제16권4호
    • /
    • pp.449-458
    • /
    • 2007
  • Research results for the pressure drop variance depending on operation conditions such as change of inlet concentration, pulse interval, and face velocity, etc., in a pulse air jet-type bag filter show that while at $3kg/cm^2$ whose pulse pressure is low, it is good to make an pulse interval longer in order to form the first layer, it may not be applicable to industry because of a rapid increase in pressure. In addition, the change of inlet concentration contributes more to the increase of pressure drop than the pulse interval does. In order to reduce operation costs by minimizing filter drag of a filter bag at pulse pressure $5kg/cm^2$, the dust concentration should be minimized, and when the inlet dust loading is a lower concentration, the pulse interval in the operation should be less than 70 sec, but when inlet dust loading is a higher concentration, the pulse interval should be below 30 sec. In particular, in the case that inlet dust loading is a higher concentration, a high-pressure distribution is observed regardless of pulse pressure. This is because dust is accumulated continuously in the filter bag and makes it thicker as filtration time increases, and thus the pulse interval should be set to below 30 sec. If the equipment is operated at 1m/min of face velocity, while pressure drop is low, the bag filter becomes larger and thus, its economics are very low due to a large initial investment. Therefore, a face velocity of around 1.5 m/min is considered to be the optimal operation condition. At 1.5 m/min considered to be the most economical face velocity, if the pulse interval increases, since the amount of variation in filter drag is large, depending on the amount of inlet dust loading, the operation may be possible at a lower concentration when the pulse interval is 70 sec. However, for a higher concentration, either face velocity or pulse interval should be reduced.

종자추출액의 안정성에 관한 연구 I - 가스크로마토그라피를 이용한 산패도 측정 - (Studies on Stability of Yoon-Je for Herb-Acupunction (I) - Measurement of Rancidity by Gas Chromatographic Analysis -)

  • 고병섭;이한구;김정숙
    • 한국한의학연구원논문집
    • /
    • 제1권1호
    • /
    • pp.541-553
    • /
    • 1995
  • In order to study the stability of herbal oil(Yoo-Je), the Yoo-Je from walnut and safflower measured their rancidity by gas chromatographic analysis. The use of specificity of column for estimating the oxidative deterioration of Yoo-Je was attempted. These results suggested the possible implication of pentanal and hexanal as an stability index for rancidity evaluation of Yoo-Je.

  • PDF

Ceramic Diesel Particulate Filter Structure with Inclined Gas Paths

  • Hwang, Yeon;Kang, Dae-Sik;Choi, Hyoung-Gwon;Lee, Choong-Hoon
    • 한국세라믹학회지
    • /
    • 제49권3호
    • /
    • pp.226-230
    • /
    • 2012
  • This paper presents a novel structure for a diesel particulate filter (DPF) with inclined gas paths, which was designed so that the gas paths offered a fluent flow of exhaust gases, and particulate matter (PM) was collected at pores formed in the body. The alumina porous filter was prepared by a conventional sintering process at $1200^{\circ}C$ for 2 h. Straight gas paths with $30^{\circ}$ of inclination from the gas flow direction were formed in the filter body. It is shown that this filter structure worked as a PM filter, in which 90.2% of soot filtration efficiency and 59.6 mbar of pressure drop were achieved.

Rheology of alumina suspensions stabilized with Tiron

  • Gulicovski, J.J.;Cerovic, Lj.S.;Milonjic, S.K.
    • Korea-Australia Rheology Journal
    • /
    • 제20권2호
    • /
    • pp.65-71
    • /
    • 2008
  • Pressure filtration technique was used to obtain defect-free microstructure of green cast ceramic bodies. Stable alumina suspensions of desired rheology (<5 Pa s at $1\;s^{-1}$) containing 60-80 mass. % solid loading were prepared in the alkaline region (at $pH{\approx}9$) with an optimum amount of 0.5 dmb % of Tiron added. Acidic region (at $pH{\approx}4$) enabled the preparation of 60 mass. % suspensions with addition of 1.5 dmb % of Tiron. The best quality slip was processed from an 80 mass.% suspension with 63% of theoretical density. The homogeneity of particle packing and the absence of defects in microstructure were proven by narrow pore size distribution (ranging from 32 to 64 nm, with up to 85% abundance), confirming advantages of the wet consolidation route.

Hollow Fiber 막에 의한 Pichia stipitis의 Cross Flow여과 (Cross Flow Filtration of Pichia stipitis by a Hollow Fiber Membrane)

  • 김홍;정인식
    • KSBB Journal
    • /
    • 제4권1호
    • /
    • pp.57-61
    • /
    • 1989
  • 발효액에서 hollow fiber membrane에 의한 Pichia sti-pitis의 분리 공정의 가능성을 검토해 보았다. Permeateflux는 cell의 농도, pH, antifoam agent의 농도, 여과 압력, 그리고 recircultion rate에 의해 영향을 받았으며 온도는 flux의 감소와 별로 관계가 없는 것으로 나타났다. 아울러 microcomputer에 조절되어 membrane을 backflush하는 것이 memnrane의 fouling 문제를 경감 시켜서 발효액에서 P. stipitis를 분리하는 공저의 연장된 조업을 가능케 함을 확인 하였다.

  • PDF

고성능 멜트블로운 부직포 복합필터 개발 (Development of composite filter with high performance meltblown non-woven)

  • 이재달;홍영기;배기서
    • 한국염색가공학회지
    • /
    • 제17권2호
    • /
    • pp.40-45
    • /
    • 2005
  • Electret filter is good enough to protect health and environment from air pollution. The reason why is gathering particles not only by mechanical mechanism but also by electrostatic attraction. Especially this filter is shown lower pressure drop than general mechanical filters as glass fiber. For making electret filter media using polypropylene meltblown(M/B) nonwoven, the nonwoven is charged with corona which was supplied high voltage DC, AC, and pulse with DC power. The electret filter media is tested with $0.3{\mu}m$ sodium chloride and dioctyl phthalate(DOP) aerosol. Results revealed that filtration performance of electret filter media increased as corona was applied with higher voltage and with AC power rather than DC, and fiber diameter was fine and uniform.

Tribological diagnostics of machinery

  • Myshkin, N.K.
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1990년도 제11회 학술강연회초록집
    • /
    • pp.7-31
    • /
    • 1990
  • Tribologicsl diagnostics as the ensemble of means and methods of continuous monitoring of the state of friction characteristics of moving junctions is playing an ever important part in the development of friction, lubrication, and wear theory end practice. The scheme presenting the main areas of tribological diagnostics is given in Fig. I. This growing part of TD is determined by the general tendency of modern technology, expressed in an attempt to organically combine the functions of measuring, evaluating,and predicting the parameters and characteristics of the processee taking place in the operating device. The logical result of this integration in future is the closed system correcting its operation in accordance with sn established program. Unfortunately, tribotechnicsl devices are still very far from such an ideal system at the present time. While in the friction assemblies with hydrodynamic lubrication it is possible in the first approximation to realize feed-backs in the lubricant circulation system with the aid of monitoring of the pressure, temperature and filtration, in the systems operating without lubrication and with boundary lubricetion even the process of selection of the diagnostic parameters has not been completed.

  • PDF