• Title/Summary/Keyword: Pressure estimation

Search Result 993, Processing Time 0.034 seconds

Estimation of Systolic Blood Pressure using PTTL (PTTL을 이용한 수축기 혈압추정)

  • Kil, Se-Kee;Kwan, Jang-Woo;Yoon, Kwang-Sub;Lee, Sang-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.6
    • /
    • pp.1095-1101
    • /
    • 2008
  • The desirable method to diagnose abnormal blood pressure is to measure and manage blood pressure continuously and regularly. However, the sphygmomanometers that are based on a cuff have faults in that they can not measure the blood pressure continuously and they cause an unpleasant feeling. Therefore, it is essential to develop a new measuring method that causes no pain and that can obtain blood pressure continuously without any unpleasant feeling. Thus, we propose here a regression method to estimate the systolic blood pressure by using the PTTL(pulse transit time on leg) with some body parameters which are chosen from the relational analysis with systolic blood pressure. The data we use to make the regression model were obtained in triplicate from each of 50 males who were from 18 to 35 years. And we made estimation experiments of blood pressure on 10 males who did not take part in the making the regression model. According to the results, the proposed method showed a mean error of 4.00 mmHg and the standard variance was 2.45 mmHg. When we comparing the results of the proposed method with the rule of American National Standards Institute of the Association of the Advancement of Medical Instruments(ANSI/AAMI), the results satisfied the rule of a mean error less than 5 mmHg and a standard variance less than 8 mmHg. Therefore we were able to validate the usefulness of the proposed method.

Estimation of Target and Completion Pressure during the Cuff Inflation Phase in Blood Pressure Measurement (혈압측정시 가압 단계에서 목표압력 및 측정 종료압력 추정)

  • Oh, Hong-Sic;Lee, Jong-Shill;Kim, Young-Soo;Shen, Dong-Fan;Kim, In-Young;Chee, Young-Joan
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.5
    • /
    • pp.371-375
    • /
    • 2008
  • In blood pressure measurement, the oscillometric method detects and analyzes the pulse pressure oscillation while deflating the cuff around the arm. For its principle, one has to inflate cuff pressure above the subject's systolic pressure and deflate below the diastolic pressure. Most of the commercialized devices inflate until the fixed target pressure and deflate until the fixed completion pressure because there is no way to know the systolic and diastolic pressure before measurement. Too high target pressure makes stress to the subject and too low target pressure makes big error or long measurement time because of re-inflation. There are similar problems for inadequate completion pressure. In this study, we suggest new algorithm to set proper target and completion pressure for each subject by analyzing pressure waveform while inflating period. We compared our proposed method and auscultation method to see the errors of estimation. The differences between the two measurements were -4.02$\pm$4.80mmHg, -10.50$\pm$10.57mmHg and -0.78$\pm$5.l7mmHg for mean arterial pressure, systolic pressure and diastolic pressure respectively. Consequently, we could set the target pressure by 30 mmHg higher than our estimation and we could stop at 20mmHg lower than our estimated diastolic pressure. Using this method, we could reduce the measurement time.

Algorithm of Copulsation Estimation for Counterpulsation using Pressure of VAD Outlet Cannula

  • Kang Jung-Soo;Lee Jung-Joo;Jung Min-Woo;Park Yong-Doo;Sun Kyung
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.2
    • /
    • pp.78-82
    • /
    • 2006
  • The ventricular assist device(VAD) helps to reduce the overload against the patient's native heart(NH). The pulsatile VAD pumps out the ventricular blood to the aorta with pulsatile flow. If the VAD pulsates simultaneously with the NH, the ventricle of the NH could confronts abnormally elevated aortic pressure, and this could deteriorate the ventricle rather than assist to recover it. Thus counterpulsation algorithms to avoid copulsation have been adopted by many VADs, but these methods utilize electrocardiography or arterial pressure signals, which may have difficulties to acquire consistently for a long period. In this study, the copulsation estimation algorithm for the counterpulsation is developed using the VAD outlet pressure signal. The VAD outlet pressure signal is good to maintain for a long time and the sensor part could be integrated to the VAD as a built-in module. From the VAD outlet pressure signal and its pump rate information calculated with Fast Fourier Transform, pulse peaks by the VAD and the NH were extracted and the next copulsation time at which the VAD and the NH would pulsate simultaneously was estimated. This estimation algorithm was implemented by using PC MATLAB software and tested for various pump rate conditions with mock circulation system. For each condition, the copulsation time was estimated successfully. Consequently, the results showed the possibility to use the outlet cannula pressure signal in the copulsation estimation.

Estimation of Non- Invasive Blood Pressure Using Peripheral Plethysmograph (말초혈관 혈류 측정을 이용한 비관혈적 혈압 추정법에 대한 연구)

  • Jeong In-cheol;Shin Tae-min;Yoon Hyung-Ro
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.8
    • /
    • pp.504-509
    • /
    • 2005
  • This paper presents a new method for obtaining the noninvasive and unrestrained blood pressure readings noninvasively and unrestrainedly using based on reflected wave arrival time(RAT) in the volume of pulse. Since this new method employs only volume pulse, is more rapider and simpler than the method using pulse transit time(PTT) because it only employs the volume of pulse. Blood pressure, PTT and RAT were acquired from 15 healthy subjects. Each subjects were performed forty trials of each measurement. As a result of those trials, the mean error between oscillometric and RAT measurements for systolic blood pressure was $4.55\pm5.64mmHg$. This result showed quite equal with the mean error between oscillometric and PPT measurf:ments, $4.22\pm5.30mmHg$, However, it was not obtained a satisfactory result in the relativity of oscillometric to both RAT and PPT measurements for diastolic blood pressure because of personal difference. To conclude, the method of systolic blood pressure estimation noninvasively and unrestrainedly using by RAT may be used as the method by PTT. Nevertheless, additional studies would be necessary for the RAT/PTT estimation of diastolic blood Pressure measurement.

Engineering J-Integral Estimation for Internal Axial Surface Cracks in Cylinders (II) -Optimised Reference Stress Based Estimation- (실린더에 존재하는 축방향 표면균열에 대한 공학적 J-적분식 (II) - 최적참조응력에 기초한 방법-)

  • Kim, Jin-Su;Kim, Yun-Jae;Kim, Young-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.11
    • /
    • pp.2442-2449
    • /
    • 2002
  • This paper provides an reference stress based J estimation equation fur cylinders with finite internal axial surface cracks under internal pressure. In part 1, the J estimation equation based on deformation plasticity using Ramberg-Osgood (R-0) materials is proposed. In this paper, the developed CE/EPRI -type solutions ale then re-formulated based on the reference stress concept. Such a re-formulation provides a simpler equation for J. estimation are then further extended to combined internal pressure and bending. The proposed reference stress based J estimation equation is compared with elastic-plastic 3-D FE results using actual stress-strain data for a Type 304 stainless steel. Good agreement between the FE results and the proposed reference stress based J estimations provides confidence in the use of the proposed method to elastic -plastic fracture mechanics of pressurised piping.

Estimation of the Degree of Consolidation using Settlement and Excess Pore Water Pressure (침하량과 과잉간극수압을 이용한 압밀도의 추정)

  • 이달원;임성훈
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.44 no.3
    • /
    • pp.111-121
    • /
    • 2002
  • This study was performed to estimate the degree of consolidation using excess pore water pressure in the very soft ground. The final settlement prediction methods by Hyperbolic, Asaoka and Curve fitting methods from the measured settlement data were used to compare with the degree of consolidation estimated by excess pore water pressure. The dissipated excess pore water pressure during embankment construction and the peak excess pore water pressure on the completed embankment were used for the estimation of the degree of consolidation. After completion of embankment, it was concluded that the degree of consolidation estimated from dissipated excess pore water pressure was more reliable than that from the peak excess pore water pressure. And, the degree of consolidation estimated from the surface settlement was nearly the same as settlement of each layer. The degree of consolidation estimated from dissipated excess pore water pressure was a little larger than that from settlement.

Blood Pressure Estimation for Development of Wearable small Blood Pressure Monitor Fusion Algorithm Analysis (웨어러블 초소형 혈압계 개발을 위한 혈압 추정 융합 알고리즘 분석)

  • Kim, Seon-Chil;Kwon, Chan-Hoe;Park, You-rim
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.11
    • /
    • pp.209-215
    • /
    • 2019
  • The most important personal health care in digital health care is a very important issue mainly for chronic diseases. Therefore, it is important to develop a simple wearable device for real-time health management. Existing blood pressure estimation wearable devices use PPG characteristics to analyze PTT and propose blood pressure estimation algorithms. However, the influencing factors of the algorithm such as the reproducibility of PPG, whether to apply various PTTs, and variables generated from the physical differences of the measurers are actually very complex. Therefore, in this study, the correlation between PTT, SBP, and DBP was analyzed, and it was designed to use PPG sensors for device miniaturization. The blood pressure estimation algorithm took into account differences in PPG, heart rate, and personal variables.

A Research on the Dynamic Pressure Estimation for the Control Law Design of High Speed Vehicle (초고속 비행체 제어기법 설계를 위한 비행체 동압 추정 기법 연구)

  • Park, Jungwoo;Kim, IkSoo;Park, Iksoo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.953-956
    • /
    • 2017
  • This paper introduces general applications of vehicle's dynamic pressure information which is estimated during the flight. And a method to estimate the dynamic pressure for a high speed vehicle is suggested to sustain reliability of the flight under a high estimation accuracy of the information. The presented method is straightforward with simple relations of the compressible flow but is a still merited idea employed for the high speed vehicle control scheme with great accuracy.

  • PDF

Effects of Sensor Errors in Air Cleaner Testing on the Cleaner Performance Estimation (공기청정기 시험기의 센서신호 오차가 공기청정기 성능 평가에 미치는 영향)

  • CHUNHWAN LEE;MINYOUNG KIM;SUMIN LEE
    • Journal of Hydrogen and New Energy
    • /
    • v.34 no.1
    • /
    • pp.77-82
    • /
    • 2023
  • The fuel cell in fuel cell electric vehicle utilizes oxygen in the atmosphere, which requires the use of an air cleaner system to minimize the intake of harmful pollutants. To estimate the performance of the air cleaner system, the pressure drop between the filter inlet and outlet is used under the rated air flow condition. In this study, the effect of sensor error in this air cleaner testing is experimentally carried out. It is found that the errors of the temperature sensor does not significantly affect the estimation of pressure drop. However, in the case of the pressure sensor, 5% sensor error results in the error of pressure drop estimation by 3%. Therefore, it is recommended that the measurement accuracy of the pressure sensor mounted in test system should be maintained at less than 5%.

Estimation of Failure Probability Using Boundary Conditions of Failure Pressure Model for Buried Pipelines (파손압력모델의 경계조건을 이용한 매설배관의 파손확률 평가)

  • Lee, Ouk-Sub;Kim, Eui-Sang;Kim, Dong-Hyeok
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.310-315
    • /
    • 2003
  • This paper presents the effect of boundary condition of failure pressure model for buried pipelines on failure prediction by using a failure probability model. The first order Taylor series expansion of the limit state function is used in order to estimate the probability of failure associated with various corrosion defects for long exposure periods in years. A failure pressure model based on a failure function composed of failure pressure and operation pressure is adopted for the assessment of pipeline failure. The effects of random variables such as defect depth, pipe diameter, defect length, fluid pressure, corrosion rate, material yield stress, material ultimate tensile strength and pipe thickness on the failure probability of the buried pipelines are systematically studied by using a failure probability model for the corrosion pipeline.

  • PDF