• Title/Summary/Keyword: Pressure Test

Search Result 7,913, Processing Time 0.031 seconds

Aerodynamic Rig Test of Radial Turbine for APU (APU용 구심터빈의 공력리그시험)

  • Kang, Jeong-Seek;Lim, Byeung-Jun;Ahn, Iee-Ki
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • An aerodynamic rig test of a radial turbine for an auxiliary power unit (APU) was performed at a high-temperature turbine test facility at the Korea Aerospace Research Institute. The pressure ratio, Mach number, and flow coefficient in the rig test are the same as those under normal engine operation conditions. The design pressure ratio is 3.096, design test speed is 34909 rpm, and turbine inlet temperature is $160^{\circ}C$. The turbine has airfoil-type nozzles, and the diameter of the turbine wheel is 175.74 mm. The turbine map is experimentally measured, and the detailed flow at the turbine inlet is measured. The pressure distribution in the nozzle at both the hub and the shroud sides and the pressure distribution along the shroud casing of the turbine wheel were measured, and this confirmed that the expansion process in the turbine wheel is acceptable.

A Study on the Determination of Construction Depth of Vertical Drain by Cone Resistance (콘 관입저항치를 이용한 수직배수재 타설심도 결정에 관한 연구)

  • Kim, Yeon-Jung;Kim, Nam-Ho;Shin Yun-Sup
    • 기술발표회
    • /
    • s.2006
    • /
    • pp.261-269
    • /
    • 2006
  • Recently, piezocone penetration test is frequently used in order to estimate the characteristics of soft ground with standard penetration test; generally used in the past In this study, standard penetration test, piezocone penetration test, driving resistance of vertical drain were used in order to increase the confidence for determination of soft ground depth. And the compressible layer was determined by the comparison between the preconsolidation pressure and the designed increase pressure. As the results, the relation between standard penetration test and piezocone penetration test shows $q_c$=(1.09~1.63)N at the soft ground, determined by 5/30 N value. And $q_c$(1.21~1.98)N was shown at the point of compressible layer, evaluated by the preconsolidation pressure. And driving resistance of vertical drain is 70 f/$cm^2$ which is equal to 10kgf/$cm^2$ cone penetration resistance.

  • PDF

Effect of Foot Reflexology on Patient's Pain and Mood Following a Mastectomy (발 반사마사지가 유방암 환자의 수술 후 통증 및 기분에 미치는 효과)

  • Chang, Hwa-Kyoung
    • Asian Oncology Nursing
    • /
    • v.1 no.2
    • /
    • pp.204-216
    • /
    • 2001
  • The purpose of this study was to test the effects of foot reflexology on pain and mood in patients who have just had a mastectomy. The research design was a nonequivalent control group, non-synchronized design. The participants for this study were 28 patients with breast cancer on first or second day after mastectomy surgery. The first 12 patients were assigned to the control group and the second 16 to the experimental group. The study was conducted from October 28, 2001 to December 22, 2001 on a surgical unit of Y Medical Center in Seoul, Korea. Pain intensity, blood pressure, pulse rate and mood were measured as dependent variables. The instrument used for pain intensity and mood was a 10 cm visual analogue scale. Cronbach alpha for this study was .70. For the experimental group pre and post tests were done immediately before and 15 minutes after completion of foot reflexology. Foot reflexology was performed once for 20 minutes. After the pretest, patients in the control group were instructed to have a quiet time for a 35 minute period and then the post-test was done. The number of participants was small so the data were analyzed by Mann-Whitney U test, and Wilcoxon signed ranks test. The results of this study are as follow : 1. In the experimental group there were significant decreases between the pre and post tests for pain intensity (z=-3.47, p<.001), diastolic blood pressure (z=-2.67, p<.01) and pulse rate (z=-3.44, p<.001) but there was no difference between the two groups on the post test. 2. The systolic blood pressure, diastolic blood pressure and pulse rate were also not significantly different between the experimental group and the control group on the post test. 3. The mood score was significantly improved after foot reflexology(z=-3.52, p=.000) and the difference between the two groups was also significant (u=49.0, p=.03). In conclusion, there was a statistically significant difference in mood between the two groups, but no difference for pain intensity, blood pressure, or pulse rate. However, there were significant differences between the pretest and post-test for pain intensity, diastolic blood pressure and pulse rate in the experimental group. On the basis of the above findings, this study suggests that foot reflexology can be an effective method of relieving pain and improving mood in clinical practice in women who have had mastectomy surgery.

  • PDF

Optimal Cutoff Points of Rate Pressure Product in Each Stage of Treadmill Exercise Test According to the Degree of Metabolic Syndrome in Korean Adults (한국성인의 대사증후군 예방을 위한 운동부하 검사시 각 단계별 심근부담률의 적정 임계점)

  • Shin, Kyung-A
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.50 no.2
    • /
    • pp.136-143
    • /
    • 2018
  • The rate pressure product (RPP) is expressed as a product of the heart rate and systolic blood pressure as an index indirectly measuring the myocardial oxygen consumption, and it indicates the burden on the myocardium. The aim of this study was to determine the optimal level of RPP for preventing metabolic syndrome in a treadmill exercise test in Korean adults. Metabolic syndrome was the diagnosis of the third executive summary report on the National Cholesterol Education Program Adult Treatment Panel III (NCEP-ATP III) criteria. According to the criteria, the metabolic syndrome diagnosis group (MetS, N=25), pre-metabolic syndrome group (Pre-MetS, N=106), and non-risk factor group (Non-MetS, N=65) were classified. The exercise stress test was performed based on the Bruce protocol. The RPP was calculated as (heart rate${\times}$systolic blood pressure)${\div}1,000$. The results showed that the maximum systolic blood pressure was high despite the low daily dose reached in the diagnostic group of metabolic syndrome. The optimal threshold of the RPP at the time of the exercise treadmill test for a metabolic syndrome prediction was $12.56mmHg{\times}beats/min{\times}10^{-3}$ in the first stage of the exercise stress test. The second stage of the exercise test was $16.94mmHg{\times}beats/min{\times}10^{-3}$, and at the third stage of the exercise test was $21.11mmHg{\times}beats/min{\times}10^{-3}$.

Effect of $H_2S$ Partial Pressure and pH of Test Solution on Hydrogen Induced Cracking of High Strength Low Alloy Steels

  • Kim, Wan Keun;Koh, Seong Ung;Kim, Kyoo Young;Yang, Boo Young;Jung, Hwan Kyo
    • Corrosion Science and Technology
    • /
    • v.4 no.6
    • /
    • pp.236-241
    • /
    • 2005
  • Hydrogen induced cracking (HIC) is one of the hydrogen degradation phenomena of linepipe steels caused by $H_2S$ gas in the crude oil or natural gas. However, NACE TM0284-96 standard HIC test method is hard to satisfy the steel requirements for sour service application since it uses more severe environmental conditions than actual conditions. Therefore, in order to use steels effectively, it is required to evaluate HIC resistance of steels in the practical range of environmental severity. In this study, HIC resistance of two high strength low alloy (HSLA) steels being used as line pipe steels was evaluated in various test solutions with different $H_2S$ pressures and pH values. The results showed that the key parameter affecting crack area ratio (CAR) is $H_2S$ partial pressure of test solution when the pH value of test solution is not over 4. Hydrogen diffusivity was not a constant value, but it was rather affected by the hydrogen ion concentration (pH value) in the solution.

Analysis for Operation Point Change in Mode Transition at the Turbopump-Gas Generator Coupled Test (터보펌프-가스발생기 연계시험의 모드 변환 중간 작동점 분석)

  • Nam, Chang-Ho;Kim, Seung-Han;Park, Soon-Young;Kim, Cheul-Woong
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.13 no.1
    • /
    • pp.43-50
    • /
    • 2009
  • The characteristics at the intermediate operation point of the turbopump-gas generator(TP-GG) coupled test were investigated by analytical method. The pump outlet pressure, gas generator mixture ratio, gas generator pressure, and temperature were examined considering risk minimization of test. The engine system shows different behavior from the TP-GG coupled test at the intermediate operation point since the combustion pressure feeds back to the flow rate in the lines. The advanced valve changes in the combustor line helps less risky mode transition.

Preliminary Design of Supersonic Ground Test Facility (초음속 지상 추진 시험설비의 기본설계)

  • 이양지;차봉준;양수석;김형진
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.13-19
    • /
    • 2003
  • A supersonic ground test facility to develop Ramjet and SCRamjet(Supersonic Combustion Ramjet) engine should be able to simulate high altitude and high Mach number conditions including air total pressure, oxygen level and specific heat ratio at the combustion chamber entrance. The test facility also should simulate the effect of oblique shock wave caused by the flight vehicle. The test facility developed in this study is supersonic free-jet blowdown type, which consists of high pressure air supply source(maximum pressure=32MPa), air heater(vitiation type), supersonic diffuser, ejector, and test chamber(nozzle exit dimension=200mm$\times$200mm).

  • PDF

Preliminary Design of Supersonic Ground Test Facility (초음속 지상 추진 시험설비의 기본설계기법 연구)

  • 이양지;차봉준;양수석;김형진
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.7 no.4
    • /
    • pp.53-62
    • /
    • 2003
  • A supersonic ground test facility to develop Ramjet and SCRamjet(Supersonic Combustion Ramjet) engine should be able to simulate high altitude and high Mach number conditions including air total pressure, oxygen level and specific heat ratio at the combustion chamber entrance. The test facility also should simulate the effect of oblique shock wave caused by the flight vehicle. The test facility developed in this study is supersonic free-jet blow down type, which consists of high pressure air supply source(maximum pressure=32MPa), air heater(vitiation type), supersonic diffuser, ejector, and test chamber(nozzle exit dimension=200mm${\times}$200mm).

Sub-System Requirements of a Pressure-fed Hot-firing Test Facility for the Performance Assessment of a LRE Thrust Chamber (액체로켓엔진 연소기의 성능평가를 위한 가압식 연소시험설비의 구성 요구조건)

  • Lee, Kwang-Jin;Lim, Byoung-Jik;Seo, Seong-Hyeon;Han, Yeoung-Min;Choi, Hwan-Seok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.15 no.4
    • /
    • pp.94-102
    • /
    • 2011
  • Sub-system requirements of a pressure-fed hot-firing test facility for performance assessment of a Liquid Rocket Engine(LRE) thrust chamber using Liquid oxygen and kerosene were described. These requirements were based on the experience of construction and operation of the ground hot-firing test facility which was used for the development of the KSR-III and a 30 tonf-class LRE thrust chamber. So it is expected that this paper is used as a basic material and an itemized previous review statement for the design and construction of a large hot-firing test facility.

Sub-System Requirements of a Pressure-fed Hot-firing Test Facility for the Performance Assessment of a LRE Thrust Chamber (액체로켓엔진 연소기의 성능평가를 위한 가압식 연소시험설비의 구성 요구조건)

  • Lee, Kwang-Jin;Lim, Byoung-Jik;Seo, Seong-Hyeon;Han, Yeoung-Min;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.63-71
    • /
    • 2010
  • Sub-system requirements of a pressure-fed hot-firing test facility for performance assessment of a Liquid Rocket Engine(LRE) thrust chamber using Liquid oxygen and kerosene were described. These requirements were based on the experience of construction and operation of the ground hot-firing test facility which was used for the development of the KSR-III and a 30 $ton_f$-class LRE thrust chamber. So it is expected that this paper is used as a basic material and an itemized previous review statement for the design and construction of a large hot-firing test facility.

  • PDF