• 제목/요약/키워드: Pressure Signal

검색결과 911건 처리시간 0.034초

압저항형 스트레인 게이지를 이용한 압력센서의 개발 (Development of Pressure Sensor using Piezo Resistance Strain gages)

  • 이동훈;강민성;허용;구재민;석창성
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.72-77
    • /
    • 2007
  • A pressure sensor is a sensing device to perceive inputing pressure and convert pressure with an electric signal. Currently, a domestic pressure sensor mostly uses mechanical methods. So, it uses many parts and its cost is high. Therefore, It is necessary to improve the weak points of an existing pressure sensor and develop the accurate and reliable pressure sensor using piezo resistance strain gages.

  • PDF

ER 유체로 작동되는 벨브의 제작 및 성능실험 (Design and Performance Test of Valve Operated by ER Fluids)

  • 장성철;염만오
    • 한국공작기계학회논문집
    • /
    • 제13권1호
    • /
    • pp.63-68
    • /
    • 2004
  • Recently ER fluids are put to practical use in fluid power industry field. As only with electrical signal change to the valve in which ER fluid flowing, ER fluid flow is controlled, so devepment of simple ER valves have been tried. In this case a technical problem is to check the pressure drop caused from flow rate change in valves because the pressure drop is very small. In this study ER valves are designed and manufactured, and small pressure drop induced from flow rate change is checked by pressure transducer which is made with appling strain gage. The ER valves and pressure drop check method are considered to be applied to the fluid power industry.

원심압축기 채널디퓨저 내부의 비정상 압력분포 (Unsteady Pressure Distributions in a Channel Diffuser of Centrifugal Compressor)

  • 강정식;조성국;강신형
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1999년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.69-77
    • /
    • 1999
  • The aim of this paper is to understand the unsteady flow phenomena in a high speed centrifugal compressor channel diffuser. Instantaneous pressures are measured at six locations in the diffuser using fast-response pressure transducers. Instantaneous pressure ratio decomposition was applied to analyze the pressure signal. In vaneless space where impeller-vaned diffuser interaction is strong, aperiodic unsteadiness is high and periodic pressure waveforms by blade passing are not clear at low flow rates, especially near vane suction side. High aperiodic unsteadiness decreases downstream of diffuser. The blade-to-blade pressure wave does not disappear in surge flow condition. In surge there exist not only large scale periodic surge wave but also blade-to-blade pressure wave.

  • PDF

수은 원자에서의 공명 다광자 이온화 과정의 레이저 강도 의존성 (Laser Intensity Dependence in Resonant Multiphoton Ionization of Hg Atoms)

  • 한재민;정도영;차형기;김철중;이종민
    • 한국광학회지
    • /
    • 제1권1호
    • /
    • pp.7-11
    • /
    • 1990
  • 수은 원자 증기에 강한 레이저 광$(10-120GW/\textrm{cm}^2)$을 조사하여 수은 원자의 공명 다광자 이온화 과정을 연구하였다. 파장 560.7nm의 광자 4개를 흡수할 때 공명준위는 $6d ^1D_2$이다. 수은 증기압(0.1-3.0 Torr)과 레이저 파장(559-569nm)을 변화시키면서 큰 강도의 광원과 원자가 상호작용하여 생기는 AC Stark 이동과 line broadening의 변화를 조사하였고, 원자 밀도의 증가에 따라 이온화율의 증가가 둔화되다가 감소되는 것도 관측되었다. 이동계수 $\alpha$=0.6cm-1/GW/$\textrm{cm}^2$로 측정되었다. 특히, 이온화율의 레이저 강도 의존성을 나타내는 비선형 차수를 공명파장에서 측정한 결과 k=3을 얻었으며, 이론적인 결과와 비교하였다.

  • PDF

The Acoustic Emission Energy Analysis of Subambient Pressure Tri-Pad Slider

  • Pan Galina;Hwang Pyung;Xuan Wu
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2004년도 학술대회지
    • /
    • pp.139-142
    • /
    • 2004
  • The object of the present work is the acoustic emission energy analysis of subambient pressure tri-pad slider. Head/disk interaction during start/stop and constant speed were detected by using acoustic emission (AE) test system The frequency spectrum analysis is performed using the AE signal obtained during the head/disk interaction Natural frequency analysis was performed using Ansys program. Acoustic emission energy was calculated for the slider modes.

  • PDF

Wavelet-based detection and classification of roof-corner pressure transients

  • Pettit, Chris L.;Jones, Nicholas P.;Ghanem, Roger
    • Wind and Structures
    • /
    • 제3권3호
    • /
    • pp.159-175
    • /
    • 2000
  • Many practical time series, including pressure signals measured on roof-corners of low-rise buildings in quartering winds, consist of relatively quiescent periods interrupted by intermittent transients. The dyadic wavelet transform is used to detect these transients in pressure time series and a relatively simple pattern classification scheme is used to detect underlying structure in these transients. Statistical analysis of the resulting pattern classes yields a library of signal "building blocks", which are useful for detailed characterization of transients inherent to the signals being analyzed.

선삭공정에서 음압을 이용한 공구마멸 파손의 상태감시 (Condition Monitoring of Tool Wear and Breakage using Sound Pressure in Turning Processes)

  • 이성일
    • 한국생산제조학회지
    • /
    • 제6권3호
    • /
    • pp.36-43
    • /
    • 1997
  • In order to make unmanned machining systems with satisfactory performances, it is necessary to incorporate appropriate condition monitoring systems in the machining workstations to provide the required intelligence of the expert. This paper deals with condition monitoring for tool wear and breakage during turning operation. Developing economic sensing and identification methods for turning processes, sound pressure measurement and digital signal processing technique are proposed. The validity of the proposed system is confirmed through the large number of cutting tests.

  • PDF

Effects of Pressure Ratio on Population Inversion in a DF Chemical Laser with Concurrent Lasing

  • Park, Jun-Sung;Baek, Seung-Wook
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.287-293
    • /
    • 2004
  • A numerical simulation is presented for investigating the effects of pressure ratio of $D_2$ injector to supersonic nozzle on the population inversion in the DF chemical laser cavity, while a lasing concurrently takes place. The laser beam is generated between the mirrors in the cavity and it is important to obtain stronger population inversion and more uniform distribution of the excited molecules in the laser cavity in order to produce high power laser beam with good quality. In this study, these phenomena are investigated by means of analyzing the distributions of the DF excited molecules and the F atom used as an oxidant, while simultaneously estimating the maximum small signal and saturated gains and power in the DF chemical laser cavity. For the numerical solution, an 11-species (including DF molecules in various excited states of energies), 32-step chemistry model is adopted for the chemical reaction of the DF chemical laser system. The results are discussed by comparison with two $D_2$injector pressure cases; 192 torr and 388.64 torr. Major results reveal that in the resonator, stronger population inversions occur in the all transitions except DF(1)-DF(0), when the $D_2$injection pressure is lower. But, the higher $D_2$injection pressure provides a favorable condition for DF(1)-DF(0) transition to generate the higher power laser beam. In other words, as the pressure of $D_2$injector increases, the maximum small signal gain in the $V_{1-0}$ transition, which is in charge of generating most of laser power, becomes higher. Therefore, the total laser beam power becomes higher.r.

  • PDF

상수도관의 누수신호 특성 및 누수지점 추정에 관한 연구 (The leak signal characteristics and estimation of the leak location on water pipeline)

  • 박상봉;김기범;서지원;김주언;구자용
    • 상하수도학회지
    • /
    • 제32권5호
    • /
    • pp.461-470
    • /
    • 2018
  • In this study, the leak signal was measured by using an accelerometer to analyze the basic data and methodology for the development of the leak point estimation method in the water supply pipe. The measured results were analyzed by frequency analysis and cross-correlation analysis for leakage signals, and the error range was compared and analyzed with the actual leak point distance. As a result, it was confirmed that the vibration intensity due to leakage from the water leakage point was attenuated according to the distance. In the case of the ductile iron casting used in the experiment, the intensity of the signal at the 945 Hz, 1,500 Hz, 2,300 Hz band was increased with the change of the pressure in the pipe at 4mm of leakage hole. Also, it was confirmed that as the water pressure increases, the intensity of the leak signal increases but the similarity of the signal decreases. The results of this study confirm that the accelerometer sensor can be used efficiently for leak detection and it can be used as a basic data for the analysis for the development of leak point estimation method in the future.

핵의학 종사자의 방사선 피폭에 따른 생체신호 변화 분석 (Analysis of Changed Bio-Signal to Radiation Exposure of Nuclear Medicine Worker)

  • 이훈재;이상복
    • Journal of Radiation Protection and Research
    • /
    • 제32권1호
    • /
    • pp.27-34
    • /
    • 2007
  • 본 논문에서는 일반인과 상대적으로 방사선피폭이 많은 핵의학 종사자들의 생체신호를 측정하여 방사선 피폭에 따른 생체신호 변화 정도를 비교 평가하고자 하였다. 핵의학과 종사자와 타부서 종사자들의 생체신호를 비교평가 하기 위하여 핵의학 종사자는 충북대학교 병원 핵의학과 종사자를 타부서 종사자는 전남대학교 병원 CT설, 일반촬영실, 의무기록실, 접수실 그리고 일반 사무실 종사자들에게 실험을 실시하였다. 실험에 쓰인 계측 장비들은 방사선량 계측을 위하여 Arrow -Tech사(社)의 poket dosimeter를 사용하였고, 생체신호인 심박수, 혈압을 측정하기 위하여 GE Medical Systems사(社)의 TONOPORT V, Heat flux, Skin temperature, Energy expenditure을 측정하기 위하여 Body Media사(社)의 Armband 인 SenseWare 2000을 사용하였다. 실험 결과 다음과 같은 결론을 얻었다. 1) 일일 장소에 따른 개인별 피폭 선량은 핵의학과가 3.05 uSv를 기록하였고, CT실, 일반촬영실, 병원 의무기록실, 병원 접수실, 일반 사무실, 교원 등이 뒤를 이었다. 핵의학과가 다른 장소(핵의학과를 제외한 나머지)에 비해 약1.4배 선량이 많았다. 2) 방사선 누적선량이 Heat flux, Skin temperature, Energy expenditure와는 별다른 관계가 없는 것을 알 수 있었다. 3) Blood pressure 에서는 Systolic blood pressure와 Diastolic blood pressure 이 핵의학과 종사자, 일반사무직 종사자, 일반인이 고르게 나타났다. 방사선선량이 상대적으로 많은 곳에서 근무하는 핵의학 종사자와 다른 직종에 종사하는 사람의 혈압을 비교해 왔을 때 변화가 없었다. 이 같은 결과로 볼 때 방사선 피폭이 상대적으로 많은 핵의학종사자들의 방사선 피폭에 따른 유해는 없다는 것을 알 수 있었다.