• Title/Summary/Keyword: Pressure Sensitivity

Search Result 933, Processing Time 0.034 seconds

Flexible Pressure Sensors Based on Three-dimensional Structure for High Sensitivity

  • Jung, Young;Cho, Hanchul
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.3
    • /
    • pp.145-150
    • /
    • 2022
  • The importance of flexible polymer-based pressure sensors is growing in fields like healthcare monitoring, tactile recognition, gesture recognition, human-machine interface, and robot skin. In particular, health monitoring and tactile devices require high sensor sensitivity. Researchers have worked on sensor material and structure to achieve high sensitivity. A simple and effective method has been to employ three-dimensional pressure sensors. Three-dimensional (3D) structures dramatically increase sensor sensitivity by achieving larger local deformations for the same pressure. In this paper, the performance, manufacturing method, material, and structure of high-sensitivity flexible pressure sensors based on 3D structures, are reviewed.

Salt Intake Behavior and Blood Pressure: the effect of taste sensitivity and preference (소금 섭취 행태와 혈압: 맛에 대한 민감도와 선호도의 영향)

  • Kim, Jin-Hee;Choi, Man-Kyu
    • Korean Journal of Human Ecology
    • /
    • v.16 no.4
    • /
    • pp.837-848
    • /
    • 2007
  • The literature suggested that a small reduction in overall blood pressure can have a large effect on overall prevalence of hypertension, and therefore, the affect of taste preferences of the population on salt intake should be considered for long-term blood pressure intervention programs. The purpose of this study is to investigate the influence of salt taste preference and salt taste sensitivity on salt intake behavior as risk factors for high blood pressure. We collected information on blood pressure, diet and lifestyle behaviors, salt taste preference and salt taste sensitivity from 540 respondents from Suseo-dong, Seoul. Salt taste sensitivity was assessed by administering a 1% NaCl solution to the subject's tongue and measuring the perceived intensity on 10 level scale. Salt intake behavior was classified into 3 categories: frequency of high-sodium foods, practice of salt-reducing behavior and frequency of vegetable and fruit intake. Salt taste preference showed a significant relation to the subjects' blood pressure, i.e. subjects with a higher salt preference had higher blood pressure. Salt taste sensitivity did not show a significant relation to blood pressure. However, there was a positive correlation between salt taste preference and salt taste sensitivity. Among the 3 indicators used to measure salt intake behavior, the practice of salt-reducing behavior remained significantly correlated to blood pressure. Moreover, salt-reducing behavior and salt taste preference showed a significant correlation, i.e. people who do not like salty foods tend to practice more salt-reducing behavior, leading to reduced levels in blood pressure. In a population, a small reduction in overall blood pressure can have large effects in overall prevalence of hypertension, in contrast to clinical studies where achievement of an individual's normal blood pressure is emphasized. Therefore, taste preference of the population should be considered for long-term blood pressure intervention programs.

Assessments of baroreflex sensitivity through the closed-loop feedback model between RR fluctuation and arterial blood pressure fluctuation (RR간격변동과 열합변동간의 폐루프 귀환 모델을 통한 압수용체반사감도의 평가)

  • 신건수;최석준;이명호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1643-1646
    • /
    • 1997
  • In this study, the method is proposed, which enable us to noninvasively assess baroreflex sensitivity through the closed-loop feedback modle between RR flucturarion and arterial blood pressure fluctuation. The proposed indexes of baroreflex sensitivity, BRS$_{LF}$와 BRS$_{HF}$ are calculated by the modulus (or gain) of the transfer function between fluctuatuons in blood pressure and RR interval in the LF band HF band, where the coherence is more than 0.5 to evaluate the performance of the proposed method, it is applied to various cardiovascular variability signals obtained form subjects under the submaximal ecericse on bicycle ergometner. In result it is concluded that the proposed method can noninvasively assess the baroreflex sensitivity.ty.

  • PDF

Additive Role of the Vestibular End Organ and Baroreceptors on the Regulation of Blood Pressure in Rats

  • Lan, Yan;Yang, Yan-Zhao;Jiang, Xian;Li, Li-Wei;Jin, Guang-Shi;Kim, Min Sun;Park, Byung Rim;Jin, Yuan-Zhe
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.17 no.4
    • /
    • pp.367-373
    • /
    • 2013
  • Contribution of the vestibular end organ to regulation of arterial pressure was quantitatively compared with the role of baroreceptors in terms of baroreflex sensitivity and c-Fos protein expression in the rostral ventrolateral medulla (RVLM). Baroreflex sensitivity and c-Fos protein expression in the RVLM were measured in conscious rats that had undergone bilateral labyrinthectomy (BL) and/or baroreceptor unloading. BL attenuated baroreflex sensitivity during intravenous infusion of sodium nitroprusside (SNP), but did not significantly affect the sensitivity following infusion of phenylephrine (PE). Baroreflex sensitivity became positive following sinoaortic denervation (SAD) during infusion of PE and attenuated sensitivity during infusion of SNP. Baroreflex sensitivity also became positive following double ablation (BL+SAD) during infusion of PE, and attenuated sensitivity during infusion of SNP. c-Fos protein expression increased significantly in the RVLM in the sham group after SNP administration. However, the BL, SAD, and SAD+BL groups showed significant decreases in c-Fos protein expression compared with that in the sham group. The SAD group showed more reduced c-Fos protein expression than that in the BL group, and the SAD+BL group showed less expression than that in the SAD group. These results suggest that the vestibular system cooperates with baroreceptors to maintain arterial pressure during hypotension but that baroreceptors regulate arterial pressure during both hypotension and hypertension. Additionally, afferent signals for maintaining blood pressure from the vestibular end organs and the baroreceptors may be integrated in the RVLM.

Preliminary Analysis on IASCC Sensitivity of Core Shroud in Reactor Pressure Vessel (원자로 노심 쉬라우드의 조사유기응력부식균열 민감도 예비 분석)

  • Kim, Jong-Sung;Park, Chang Je
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.15 no.2
    • /
    • pp.58-63
    • /
    • 2019
  • This paper presents preliminary analysis and results on IASCC sensitivity of a core shroud in the reactor pressure vessel. First, neutron irradiation flux distribution of the reactor internals was calculated by using the Monte Carlo simulation code, MCNP6.1 and the nuclear data library, ENDF/B-VII.1. Second, based on the neutron irradiation flux distribution, temperature and stress distributions of the core shroud during normal operation were determined by performing finite element analysis using the commercial finite element analysis program, ABAQUS, considering irradiation aging-related degradation mechanisms. Last, IASCC sensitivity of the core shroud was assessed by using the IASCC sensitivity definition of EPRI MRP-211 and the finite element analysis results. As a result of the preliminary analysis, it was found that the point at which the maximum IASCC sensitivity is derived varies over operating time, initially moving from the shroud plate located in the center of the core to the top shroud plate-ring connection brace over operating time. In addition, it was concluded that IASCC will not occur on the core shroud even after 60 years of operation (40EFPYs) because the maximum IASCC sensitivity is less than 0.5.

The Diaphragm Structure Using the Local Surface Etching for the Improvement of Sensitivity Characteristics (감도특성 향상을 위한 국부적 표면식각 다이아프램 구조 연구)

  • Lee, Gon-Jae;Oh, Dong-Hwan;Lee, Jong-Hong;Kim, Sung-Jin
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.309-315
    • /
    • 2004
  • In the pressure sensor, about below 20 kPa, the center boss diaphragm structure is generally used, but it is hard to obtain the high sensitivity because the center boss structure is limited at the thickness and size of diaphragm with chip size. Therefore, this paper suggests that the Center boss structure has surface etched diaphragm using a stress concentration to improve the sensitivity. We carried out the simulation and fabrication applied new diaphragm design. In the result, the sensitivity is improved to 60% without the change of non-linearity (0.14%FS). So, the Center boss of surface etched diaphragm can be applied for the high sensitivity in the low-pressure sensor.

Implementation of an Integrated Pressure-sensor System Adapted to the Optimum Sensitivity

  • Hong, Sung-Hee;Cho, Chun-Hyung
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.17 no.2
    • /
    • pp.186-191
    • /
    • 2017
  • An integrated pressure-sensor system was developed using the sensor-conditioning processes, which resulted in the optimum sensitivity of the pressure-sensor through the signal amplification, noise reduction, and level shift. Due to the specified characteristics among the components, such as operation range, the sensor output was generally limited compared to the full scale of the reading when coupled with other parts. Devices fabricated exhibited comparable characteristics with higher pressure sensitivity to that of the pressure sensor without sensor-conditioning process. In this work, the sensor resolution was at least enhanced at least by 25% using the sensor-conditioning processes.

Effects of Sodium Intakes on Blood Pressure and Blood Parameters in Korean Normal Adult Women (나트륨 섭취수준이 정상 성인 여성의 혈압과 혈액성상에 미치는 영향)

  • 이영근;승정자;최미경;이윤신
    • Journal of Nutrition and Health
    • /
    • v.35 no.7
    • /
    • pp.754-762
    • /
    • 2002
  • This study was performed to investigate the effect of sodium intake on blood pressure and blood parameters. 20 young adult women were fed the diets containing 290.5 mEq (high-Na diet) and 51.3 mEq (low-Na diet) Na for 6 days, respectively. BMI, DBP, and MBP were significantly lower in low-Na diet than those in high-Na diet. 20 subjects were divided into 3 groups according to the salt-sensitivity. In salt-sensitive group, decreases in SBP, DBP, and MBP by low-Na diet were shown. And there were not significant difference in blood pressure of salt-resistant group between high- and low-Na diet. In count-reactive group, MBP in low-Na diet was significantly higher than that in high-Na diet. Hemoglobin, creatinine, uric acid, and haptoglobin levels in serum were significantly higher in low-Na diet than those in high-Na diet. Among groups with different salt-sensitivity, increments of haptoglobin by low-Na diet were shown in salt-sensitive and counter-reactive groups. Actually, low sodium diet affects not only the blood pressure, but other biochemical parameters which in turn affect an individual overall health. Also salt-sensitivity should be considered as an important determinant. Therefore, for the patients who need restricted Na diet, it would be suggested that various biochemical changes and individual salt-sensitivity should be carefully considered along with dietary Na manipulation.

In-Process Diagnosis of Servovalve wear in Hydraulic Force Control Systems (유압실린더 힘 제어계의 인-프로세스 서보밸브 마모진단에 관한 연구)

  • Kim, S.D.;Jeon, S.H.;Chang, Y.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.6 no.2
    • /
    • pp.22-30
    • /
    • 2009
  • An in-process method of diagnosing the spool wear of hydraulic servovalves was explored. The diagnostic method discussed in this paper is for force-control hydraulic servo systems. The key principle used is that pressure sensitivity of a servovalve drops as the valve spool wears out so that it is possible to determine the spool condition by monitoring pressure sensitivity. A diagnostic algorithm was developed and evaluated through numerical simulation and experiments. Two major steps of diagnosis are the evaluation of null bias of the servovalve and the approximation of pressure sensitivity, both of which could be successfully done during normal operation of a servo system. The difference between a new servovalve and a worn valve could be clearly detected in-process, and the diagnostic test was found to be repeatable.

  • PDF

Fiber optic pressure sensor (광섬유 압력센서)

  • 이기완;배준형
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.640-643
    • /
    • 1996
  • In this paper, a sensitivity of the fiber optic pressure sensor in water is demonstrated. A single mode optical fiber Mach-Zehnder interferometer used to detect the change in optical path length produced by the change of fiber optic strain in water. The sensitivity with this system measured 100.mu.psia through an experiment in the static response.

  • PDF